Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy reductions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Pilot scale testing of an advanced solvent in a 0.7 MWe post-combustion CO 2 capture unit

An advanced Amine Promoted Buffer Solution (APBS), APBS-CDRMax® (CDRMax), developed by Carbon Clean Solutions Limited (CCSL), was tested at the 0.7 MWe CO 2 capture facility at Kentucky Utilities E.W. Brown Generation Station using a heat-integrated two-staged stripping CO 2 capture process. The performance of the solvent was evaluated to determine operating conditions that maximized the cyclic capacity of the solvent and results in energy savings. The regeneration energy ranged from 2.9 to 3.3 GJ/ton CO 2 with 14 vol % (dry) CO 2 inlet and approximately 90 % capture. The difference in the reboiler specific heat duty at stripper pressures of 1.7 and 2.1 bar was minimal as similar amounts of water vapor were observed in the CO 2 product stream at stripper outlet. Recycling of product CO 2 increased the inlet CO 2 concentration to the absorber from 14 to 16 vol% which enhanced mass transfer from the gas to the solvent resulting in about 5 % reduction in the energy of regeneration at the lower stripper pressure. The solvent circulation rate was reduced by about 30 % relative to previous 30 wt% MEA campaign for the CO 2 target capture of 90 %. Finally, the reduced solvent make-up rate of CDRMax shows promise for capital and operating cost savings for post-combustion CO 2 capture.

42 ENGINEERING↗

Fluorinated polythiophenes with ester side chains for boosting the V OC and efficiency in non-fullerene polymer solar cells

As the power conversion efficiency (PCE) of organic photovoltaics (OPVs) approximates the 19 % threshold, wide bandgap (WBG) polythiophenes (PTs) have gained increasing attention due to their simple chemical structures and ease of synthesis, making them promising candidates for large-scale production. However, the benchmark polymer poly(3-hexylthiophene) (P3HT) is limited by its high-lying HOMO energy level, which restricts the open-circuit voltage (V OC ) in solar cells. Here, in this study, we introduce a novel series of PT derivatives (PDC8-T, PDC8-3T, PDC16-3T, and PDC16-3T-2F) featuring ester side chains designed to fine-tune electronic properties through a streamlined three-step synthesis. Additionally, we incorporated a π-spacer to reduce steric hindrance and elongated alkyl side chains to improve solubility and processability. Compared to P3HT, these PT derivatives demonstrate a significant reduction in HOMO energy levels, lowering by approximately 0.3–0.4 eV. Among them, PDC16-3T-2F—with fluorine atom substitution—achieves the lowest HOMO energy level, induces a coplanar molecular conformation, and enhances polymer aggregation behavior. We evaluated these PT derivatives in inverted non-fullerene bulk-heterojunction (NFA BHJ) OPVs. The PDC8-3T device showed a relatively low PCE of 0.69 %, with a V OC of 0.76 V, a short-circuit current density (J SC ) of 3.32 mA/cm 2 , and a fill factor (FF) of 27.3 %. In contrast, the PDC16-3T-2F device achieved an impressive PCE of 7.21 %, with a V OC of 0.85 V, a J SC of 14.60 mA/cm 2 , and an FF of 58.4 %. This remarkable improvement is attributed to the fluorine substitution, which not only enhances molecular orientation but also downshifts the HOMO energy level and further boosts the V OC . Hence, these molecular design strategies have led to a fibrillar bicontinuous interpenetrating network with optimal nanoscale phase separation within the active layer.

14 SOLAR ENERGY↗

Impact of selenium addition to the cadmium-zinc-telluride matrix for producing high energy resolution X-and gamma-ray detectors

Abstract Both material quality and detector performance have been steadily improving over the past few years for the leading room temperature radiation detector material cadmium-zinc-telluride (CdZnTe). However, although tremendous progress being made, CdZnTe still suffers from high concentrations of performance-limiting defects, such as Te inclusions, networks of sub-grain boundaries and compositional inhomogeneity due to the higher segregation coefficient of Zn. Adding as low as 2% (atomic) Se into CdZnTe matrix was found to successfully mitigate many performance-limiting defects and provide improved compositional homogeneity. Here we report record-high performance of Virtual Frisch Grid (VFG) detector fabricated from as-grown Cd 0.9 Zn 0.1 Te 0.98 Se 0.02 ingot grown by the Traveling Heater Method (THM). Benefiting from superior material quality, we achieved superb energy resolution of 0.77% at 662 keV (as-measured without charge-loss correction algorithms) registered at room temperature. The absence of residual thermal stress in the detector was revealed from white beam X-ray topographic images, which was also confirmed by Infra-Red (IR) transmission imaging under cross polarizers. Furthermore, neither sub-grain boundaries nor their networks were observed from the X-ray topographic image. However, large concentrations of extrinsic impurities were revealed in as-grown materials, suggesting a high likelihood for further reduction in the energy resolution after improved purification of the starting material.

36 MATERIALS SCIENCE↗

Cellulose Nanofibrils Dewatered with Poly(Lactic Acid) for Improved Bio-Polymer Nanocomposite Processing

Cellulose nanofibrils (CNFs) have theoretically ideal properties for bio-based composite applications; however, the incorporation of these materials into polymers is made challenging by the strong binding of water to CNFs and the irreversible agglomeration of CNFs during drying. Previous methods used “contact dewatering”, wherein the addition of wood flour (WF) to CNFs facilitated the mechanical removal of water from the system via cold pressing, which showed potential in producing dried CNF fibrils attached to wood fibers for biocomposite applications. In this work, the viability of contact dewatering with poly(lactic) acid (PLA) powder for PLA/CNF composites was evaluated. The energy efficiency of dewatering, preservation of nanoscale CNF morphology, and mechanical properties were examined by mixing wet CNFs with pulverized PLA at various loading levels, pressing water out of the system, and compression molding and shear mixing composites for testing. The most impressive results from this dewatering method were the preservation of micron-to-nanoscale fibers with high aspect ratios in PLA-CNF composites; increased strength and modulus of 1.7% and 4.2%, respectively, compared to neat PLA; equivalent or better properties than spray-dried nanocellulose at similar loading levels; and an 11-194x reduction in drying energy compared to spray-drying CNFs.

Chemistry↗

Quantitative Ceilometer-Radar Studies of Clouds Field Campaign Report

The Long Island Solar Farm (LISF) is a 32-megawatt solar photovoltaic power plant built through a collaboration including BP Solar, the Long Island Power Authority (LIPA), and the U.S. Department of Energy (DOE). The LISF, located on the Brookhaven National Laboratory site, began delivering power to the LIPA grid in November 2011, and is currently one of the largest solar photovoltaic power plants in the eastern United States. It is generating enough renewable energy to power approximately 4,500 homes and is helping New York State meet its clean energy and carbon reduction goals. Brookhaven National Laboratory (BN)L has the LISF instrumented and is capturing solar insolation and power data that can be used for research purposes. Additional information on LISF is available here: https://www.bnl.gov/lisf/. A network of nine high-definition (HD cameras) and 32 pyranometers are deployed within the LISF for the purpose of monitoring the location and characteristics of clouds and available global horizontal irradiance at the surface across the region. Information collected by this network every 30 s is currently used in BNL’s solar NowCasting algorithm, which forecasts near-term solar energy availability accounting for the behavior of clouds. The most important parameters for forecasting the near-term solar energy availability are accurate estimations of their horizontal extend, horizontal motion, and cloud base height. Currently, images from nearly located cameras are used to estimate the cloud base height. In order to evaluate the potential of this method for estimating the cloud base height, we decided to deploy a Vaisala ceilometer at the LISF.

14 SOLAR ENERGY↗

Interfacial Engineering Using Covalent Organic Frameworks in Polymer Composites for High‐Temperature Electrostatic Energy Storage

Abstract The use of inorganic nanofillers has been an effective method to improve high‐temperature capacitive performance of dielectric polymers, though there are unmet challenges such as undesirable organic–inorganic compatibility, and low efficiencies and energy densities. Herein, a surface functionalization strategy using covalent organic frameworks (COFs) is employed to address such challenges in realizing high‐performing polymer composites. Specifically, core–shell structured nanoparticles, where ZrO 2 nanoparticles act as the core and a COF material forms the shell, are constructed and composited with the polyetherimide (PEI) matrix. The design leverages the high electron affinity ( E A ) of the outer COF shell to create energy traps, thereby capturing free charges and limiting electrical conduction. Concurrently, the low E A and wide bandgap of the ZrO 2 core introduce energy barriers to impede charge injection and migration. This orchestrated “energy level cascade” results in a marked reduction of leakage current and energy loss. The resulting polymer composite showcases an impressive discharged energy density of 6.21 J cm −3 at an efficiency above 90%, with a maximum discharged energy density reaching 7.43 J cm −3 at 150 °C. These performance metrics position the PEI/ZrO 2 @COF polymer composite to surpass or be on par with state‐of‐the‐art high‐temperature PEI composites and other advanced polymer dielectrics.

Xie, Zongliang↗

Pareto-optimal target definition for multi-axis random vibration testing

In random vibration testing with multiple control channels, existing control laws require specification of a complete spectral density matrix at each control frequency. Spectral density matrices include autospectral densities on the diagonal and cross-spectral densities on the off-diagonal. In practice, the off-diagonal terms are often unknown, and recent vibration testing research has focused on fixing the diagonal and specifying the off-diagonal to minimize the required control energy, subject to a constraint that the target matrix is positive semidefinite. This paper shows that, even with a fixed diagonal, off-diagonal terms strongly affect control residuals. This overlooked effect occurs in both square and rectangular systems. By jointly considering input energy and control residuals, open-loop inputs are derived directly from the diagonal without specifying the off-diagonal terms. Vibration targets that can be used in closed-loop control are then derived using the optimal inputs, with positive semidefinite constraints applied during the derivation. The result is a set of Pareto-optimal control solutions. For each solution in the set, any other possible solution produces greater control error, greater input energy, or both. A balanced solution is selected automatically, though others can be chosen based on test needs. Simulations and experiments show that the proposed method outperforms state-of-the-art energy-minimizing approaches, achieving significant reductions in both control error and input energy.

Autospectral density↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Lanczos vectors to control design of flexible structures

This report covers research conducted during the first year of the two-year grant. The research, entitled 'Application of Lanczos Vectors to Control Design of Flexible Structures' concerns various ways to obtain reduced-order mathematical models for use in dynamic response analyses and in control design studies. This report summarizes research described in several reports and papers that were written under this contract. Extended abstracts are presented for technical papers covering the following topics: controller reduction by preserving impulse response energy; substructuring decomposition and controller synthesis; model reduction methods for structural control design; and recent literature on structural modeling, identification, and analysis.

Craig, Roy R., Jr.↗

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection of voids in hydrogen embrittled iron using transmission X-ray microscopy

Hydrogen embrittlement remains a barrier to widespread adoption of hydrogen as a carbon-neutral energy source. Here, hydrogen embrittlement mechanisms are investigated across length scales in iron using transmission X-ray microscopy (TXM), digital image correlation (DIC), and notched tensile testing during in-situ electrochemical hydrogen charging. TXM reveals void size and spatial distribution ahead of a propagating crack. We find hydrogen charging leads to voids within ~10 μm of the crack tip and suppression of voids beyond this distance. Near the crack tip, voids are elongated in the direction of the crack and are smaller than voids in an uncharged sample. In the presence of hydrogen, these voids lead to quasi-cleavage fracture and a sharper crack tip. DIC shows localization and reduction of plastic strain with hydrogen charging, and tensile testing reveals a reduction in fracture energy and elongation at failure. Finally, these results are discussed in the context of hydrogen embrittlement mechanisms.

08 HYDROGEN↗

Control of hydrogen concentrations by microbial sulfate reduction in two contrasting anoxic coastal sediments

Introduction Molecular hydrogen is produced by the fermentation of organic matter and consumed by organisms including hydrogenotrophic methanogens and sulfate reducers in anoxic marine sediment. The thermodynamic feasibility of these metabolisms depends strongly on organic matter reactivity and hydrogen concentrations; low organic matter reactivity and high hydrogen concentrations can inhibit fermentation so when organic matter is poor, fermenters might form syntrophies with methanogens and/or sulfate reducers who alleviate thermodynamic stress by keeping hydrogen concentrations low and tightly controlled. However, it is unclear how these metabolisms effect porewater hydrogen concentrations in natural marine sediments of different organic matter reactivities. Methods We measured aqueous concentrations of hydrogen, sulfate, methane, dissolved inorganic carbon, and sulfide with high-depth-resolution and 16S rRNA gene assays in sediment cores with low carbon reactivity in White Oak River (WOR) estuary, North Carolina, and those with high carbon reactivity in Cape Lookout Bight (CLB), North Carolina. We calculated the Gibbs energies of sulfate reduction and hydrogenotrophic methanogenesis. Results Hydrogen concentrations were significantly higher in the sulfate reduction zone at CLB than WOR (mean: 0.716 vs. 0.437 nM H 2 ) with highly contrasting hydrogen profiles. At WOR, hydrogen was extremely low and invariant (range: 0.41–0.52 nM H 2 ) in the upper 15 cm. Deeper than 15 cm, hydrogen became more variable (range: 0.312–2.56 nM H 2 ) and increased until methane production began at ~30 cm. At CLB, hydrogen was highly variable in the upper 15 cm (range: 0.08–2.18 nM H 2 ). Ratios of inorganic carbon production to sulfate consumption show AOM drives sulfate reduction in WOR while degradation of organics drive sulfate reduction in CLB. Discussion We conclude more reactive organic matter increases hydrogen concentrations and their variability in anoxic marine sediments. In our AOM-dominated site, WOR, sulfate reducers have tight control on hydrogen via consortia with fermenters which leads to the lower observed variance due to interspecies hydrogen transfer. After sulfate depletion, hydrogen accumulates and becomes variable, supporting methanogenesis. This suggests that CLB’s more reactive organic matter allows fermentation to occur without tight metabolic coupling of fermenters to sulfate reducers, resulting in high and variable porewater hydrogen concentrations that prevent AOM from occurring through reverse hydrogenotrophic methanogenesis.

Microbiology↗

Maximizing long-term biohydrogen production with Clostridium thermocellum for high solids conversion of lignocellulosic biomass

Biological hydrogen production from lignocellulosic biomass sustainably couples organic waste reduction with renewable energy generation. Efficient conversion is challenged by the structural complexity of lignocellulose and resulting recalcitrance to enzymatic degradation. Clostridium thermocellum natively breaks down biomass with highly effective hemi-/cellulases systems (i.e., cellulosomes) and generates hydrogen in anaerobic cultivation, creating a compelling platform for lignocellulosic biohydrogen production. Achieving commercially viable production rates requires balancing high biomass loading and throughput against uniform mixing conditions required for enzyme dispersion, pH and temperature control, and efficient hydrogen and metabolite removal in continuous operation. To address these barriers to process intensification, we implemented novel reactor and process designs for high-solids lignocellulosic biomass fermentations using the C. thermocellum KJC19-9 strain, genetically engineered for co-utilization of cellulose and hemicellulose sugars (i.e., xylose). Via computational fluid dynamics (CFD) modeling and experimental validation, we achieved a >50% improvement in biohydrogen production with an improved anchor-type impeller morphology, coupled to a threefold reduction in agitation rate. To further reduce rheological constraints and accumulation of toxic metabolites, we then transitioned the process to sequencing fed-batch operation. The resulting process generated 24.87 L H 2 L −1 from 160 g L −1 of deacetylated and mechanically refined (DMR)-pretreated corn stover biomass over 16 days while solubilizing >95% of influent cellulose and hemicellulose, setting a new performance benchmark for continuous production of biohydrogen from lignocellulose.

08 HYDROGEN↗

Machine learning-based ethylene concentration estimation, real-time optimization and feedback control of an experimental electrochemical reactor

With the increase in electricity supply from clean energy sources, electrochemical reduction of carbon dioxide (CO 2 ) has received increasing attention as an alternative source of carbon-based fuels. As CO 2 reduction is becoming a stronger alternative for the clean production of chemicals, the need to model, optimize and control the electrochemical reduction of the CO 2 process becomes inevitable. However, on one hand, a first-principles model to represent the electrochemical CO 2 reduction has not been fully developed yet because of the complexity of its reaction mechanism, which makes it challenging to define a precise state-space model for the control system. On the other hand, the unavailability of efficient concentration measurement sensors continues to challenge our ability to develop feedback control systems. Gas chromatography (GC) is the most common equipment for monitoring the gas product composition, but it requires a period of time to analyze the sample, which means that GC can provide only delayed measurements during the operation. Moreover, the electrochemical CO 2 reduction process is catalyzed by a fast-deactivating copper catalyst and undergoes a selectivity shift from the product-of-interest at the later stages of experiments, which can pose a challenge for conventional control methods. To this end, machine learning (ML) techniques provide a potential approach to overcome those difficulties due to their demonstrated ability to capture the dynamic behavior of a chemical process from data. Motivated by the above considerations, we propose a machine learning-based modeling methodology that integrates support vector regression and first-principles modeling to capture the dynamic behavior of an experimental electrochemical reactor; this model, together with limited gas chromatography measurements, is employed to predict the evolution of gas-phase ethylene concentration. The model prediction is directly used in a proportional-integral (PI) controller that manipulates the applied potential to regulate the gas-phase ethylene concentration at energy-optimal set-point values computed by a real-time process optimizer (RTO). Specifically, the RTO calculates the operation set-point by solving an optimization problem to maximize the economic benefit of the reactor. Finally, suitable compensation methods are introduced to further account for the experimental uncertainties and handle catalyst deactivation. The proposed modeling, optimization, and control approaches are the first demonstration of active control for a CO 2 electrolyzer and contribute to the automation and scale-up efforts for electrified manufacturing of fuels and chemicals starting from CO 2 .

42 ENGINEERING↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

On the accuracy of the chemically significant eigenvalue method

We study the accuracy and convergence properties of the chemically significant eigenvalues method as proposed by Georgievskii et al. [J. Phys. Chem. A 117, 12146-12154 (2013)] and its close relative, dominant subspace truncation, for reduction of the energy-grained master equation. We formally derive the connection between both reduction techniques and provide hard error bounds for the accuracy of the latter which confirm the empirically excellent accuracy and convergence properties but also unveil practically relevant cases in which both methods are bound to fall short. We propose the use of balanced truncation as an effective alternative in these cases.

Chemistry↗