Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Model Choice Metrics to Optimize Profile-QSAR Performance

Predicting molecular activity against protein targets is difficult because of the paucity of experimental data. Approaches like multitask modeling and collaborative filtering seek to improve model accuracy by leveraging results from multiple targets, but are limited because different compounds are measured with different assays, leading to sparse data matrices. Profile-QSAR (pQSAR) 2.0 addresses this problem by fitting a series of partial least squares models for each target, using as features the predictions from single-task models on the remaining targets. Here, this method has been shown to produce better results than single task and multitask models. However, the factors determining the success of pQSAR 2.0 have as yet not been characterized. In this paper we examine the experimental conditions that lead to better pQSAR models. We limit the amount of data available to the method by retraining with decreasing amounts of data and explore the model’s ability to generalize to compounds that have never been assayed. Finally, we look at the properties of training data needed to demonstrate pQSAR improvement.

Biological and medical sciences, Computer science↗

GPU-accelerated denoising of 3D magnetic resonance images

The raw computational power of GPU accelerators enables fast denoising of 3D MR images using bilateral filtering, anisotropic diffusion, and non-local means. In practice, applying these filtering operations requires setting multiple parameters. This study was designed to provide better guidance to practitioners for choosing the most appropriate parameters by answering two questions: what parameters yield the best denoising results in practice? And what tuning is necessary to achieve optimal performance on a modern GPU? To answer the first question, we use two different metrics, mean squared error (MSE) and mean structural similarity (MSSIM), to compare denoising quality against a reference image. Surprisingly, the best improvement in structural similarity with the bilateral filter is achieved with a small stencil size that lies within the range of real-time execution on an NVIDIA Tesla M2050 GPU. Moreover, inappropriate choices for parameters, especially scaling parameters, can yield very poor denoising performance. To answer the second question, we perform an autotuning study to empirically determine optimal memory tiling on the GPU. The variation in these results suggests that such tuning is an essential step in achieving real-time performance. These results have important implications for the real-time application of denoising to MR images in clinical settings that require fast turn-around times.

97 MATHEMATICS AND COMPUTING↗

Crack detection in fuel cell electrodes using a spatial filtering technique for overcoming noisy backgrounds

Image processing is a powerful tool that allows for rapid and automated data parsing in settings that occupy large variable spaces and require large data sets. Feature detection on difficultly discerned backgrounds is a subset of image processing that facilitates the extraction of quantitative metrics from otherwise subjective data. Crack detection and quantification is an important capability in polymer electrolyte membrane fuel cell quality control, failure analysis, and optimization. This work presents a technique to perform crack detection and quantification which overcomes challenges faced by commonly used image segmentation techniques. We demonstrate the use of a geometrically filtered noise‐level detection technique to select a binary threshold value from which we then quantify how cracked a sample is. Furthermore, we demonstrate the accuracy of our technique using programmatically generated test images of known crack amounts and their performance on real‐world fuel cell catalyst layer samples.

30 DIRECT ENERGY CONVERSION↗

A Workflow to Optimize Fast Neutron Irradiation in A Thermal Neutron Spectrum Test Reactor Leveraging Open-Source Tools

The Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL) is one of the key nuclear engineering research and testing facilities within the US Department of Energy (DOE). The ATR is one of few high-power research reactors in the world with different application including accelerated testing of nuclear fuel, materials irradiation in a very high neutron flux environment, and medical radioisotope production [1]. Also, the ATR offers opportunities for testing fast spectrum fission and fusion reactor materials. The key challenges in this area are in further detailing and optimizing a fast spectrum environment within a thermal test reactor. This challenge involves researching, developing, and testing novel concepts for the multiplying of neutron populations into ever higher energy spectra in high flux test reactors like ATR. The main objective of this work is to investigate candidate materials for establishing a fast neutron experiment irradiation in thermal neutron spectrum test reactors which can be accomplished by filtering thermal and epithermal neutrons and boosting fast neutrons at designated irradiation positions. However, adding these filters will render the neutron spectrum and the criticality of the system. The selection of the thickness and material layers should be accomplished by developing an optimization design algorithm that is applicable for ATR to enhance the fast neutron spectrum irradiation utilizing high-fidelity Monte Carlo methods along with advanced machine learning capabilities. This paper presents workflow for design optimization to enhance fast neutron irradiation in the ATR. The workflow leverages open-source tools to develop an algorithm that is viable to ATR and can be leveraged in other reactors. The following sections discuss the development of the experiment design optimization workflow and its application to ATR irradiation positions.

42 - ENGINEERING↗

Filtered Backprojection in Compton Imaging using a Spherical Harmonic Wiener Filter with Pixelated CdZnTe

Filtered backprojection is an image reconstruction technique for Compton imaging that provides reasonably high resolution at much lower computational costs when compared to iterative methods. Here, this work applies a Wiener filter that has been derived for spherical harmonics on Compton imaging using the OrionUM pixelated CdZnTe imaging-spectrometer. To regularize the filter, an investigation is made into the power spectral density of the signal and noise to develop an appropriate spectral signal-to-noise ratio model for the restoration process. Experimental measurements were conducted with two 228Th sources placed 30° apart. The resulting filtered image of the two sources have an average full-width-at-half-maximum (FWHM) of 9.8° or 7.5° when using a mean squared error and structural similarity optimization approach respectively; an improvement from the 29.0° FWHM image when using simple backprojection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Filtering and Control in Example: Unstable Qubits

A brief account of the quantum unstable controlled dynamics admitting continuous demolition measurement is given. The dynamical programming method for optimization of quantum control with convex constraints and concave cost functions of quantum conditional state is presented. Consideration is given to open loop control corresponding to deterministic conditionally-Markov dynamics of a quantum unstable system. A single controlled decaying qubit conditioned by its survival is considered as an example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of series H{sup −} multicusp ion source at China Institute of Atomic Energy

The development of H{sup −} multicusp ion sources has been carried out at China Institute of Atomic Energy (CIAE) for more than ten years. The first H{sup −} ion source with 5.2 mA was made in 2002. After improving the configured magnetic field, a H{sup −} ion source of 10 mA was made in 2004, and the beam intensity of 15 mA was obtained in 2008 after further improvements of the filter field. The beam intensity of 18 mA was achieved in 2010 following the in-depth study and optimization on some essential operation conditions. Now a series of H{sup −} cusp sources with different sizes and beam intensity ranging from 3 mA to 18 mA have been successfully developed at CIAE. All the ion sources can fast finish the test on the test stand now, since all the connections are modularized and can fit all kinds of H{sup −} mulitcusp source of CIAE. The development status of the various H{sup −} multicusp ion sources at CIAE are presented in the paper.

43 PARTICLE ACCELERATORS↗

A windowed mean trajectory approximation for condensed phase dynamics

We propose a trajectory-based quasi-classical method for approximating dynamics in condensed phase systems. Building upon the previously developed optimized mean trajectory approximation that has been used to compute linear and nonlinear spectra, we borrow some ideas from filtering trajectory methods to obtain a novel semiclassical method for the dynamical propagation of density matrices. This new approximation is tested rigorously against standard multistate electronic models, spin-boson models, and models of the Fenna–Matthews–Olson complex. For dissipative systems, the current method is significantly better or as good as many other semiclassical methods available, especially at low temperatures and for off-diagonal density matrix elements, whereas for scattering models, the current method bears similar limitations as mean-field propagation schemes. All results are tested against the numerically exact hierarchical equations of motion method. In conclusion, the new method shows excellent agreement across various parameter regimes with numerically exact results, highlighting the robustness and accuracy of our approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal constraint on g{sub NL} from CMB

An optimal method to constrain the non-linearity parameter g{sub NL} of the local-type non-Gaussianity from CMB data is proposed. Our optimal estimator for g{sub NL} is separable and can be efficiently computed in real space. Combining the exact filtering of CMB maps with the full covariance matrix, our method allows us to extract cosmological information from observed data as much as possible and obtain a tighter constraint on g{sub NL} than previous studies. Applying our method to the WMAP 9-year data, we obtain the constraint g{sub NL} = (−3.3±2.2) × 10{sup 5}, which is a few times tighter than previous ones. We also make a forecast for PLANCK data by using the Fisher matrix analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Local quantum control of Heisenberg spin chains

Motivated by some recent results of quantum control theory, we discuss the feasibility of local operator control in arrays of interacting qubits modeled as isotropic Heisenberg spin chains. Acting on one of the end spins, we aim at finding piecewise-constant control pulses that lead to optimal fidelities for a chosen set of quantum gates. We analyze the robustness of the obtained results for the gate fidelities to random errors in the control fields, finding that with faster switching between piecewise-constant controls the system is less susceptible to these errors. The observed behavior falls into a generic class of physical phenomena that are related to a competition between resonance- and relaxation-type behavior, exemplified by motional narrowing in NMR experiments. Finally, we discuss how the obtained optimal gate fidelities are altered when the corresponding rapidly varying piecewise-constant control fields are smoothened through spectral filtering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Composite gravitational-wave detection of compact binary coalescence

The detection of gravitational waves from compact binaries relies on a computationally burdensome processing of gravitational-wave detector data. The parameter space of compact-binary-coalescence gravitational waves is large and optimal detection strategies often require nearly redundant calculations. Previously, it has been shown that singular value decomposition of search filters removes redundancy. Here we will demonstrate the use of singular value decomposition for a composite detection statistic. This can greatly improve the prospects for a computationally feasible rapid detection scheme across a large compact binary parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping the genome of meta-generalized gradient approximation density functionals: The search for B97M-V

A meta-generalized gradient approximation density functional paired with the VV10 nonlocal correlation functional is presented. The functional form is selected from more than 10{sup 10} choices carved out of a functional space of almost 10{sup 40} possibilities. Raw data come from training a vast number of candidate functional forms on a comprehensive training set of 1095 data points and testing the resulting fits on a comprehensive primary test set of 1153 data points. Functional forms are ranked based on their ability to reproduce the data in both the training and primary test sets with minimum empiricism, and filtered based on a set of physical constraints and an often-overlooked condition of satisfactory numerical precision with medium-sized integration grids. The resulting optimal functional form has 4 linear exchange parameters, 4 linear same-spin correlation parameters, and 4 linear opposite-spin correlation parameters, for a total of 12 fitted parameters. The final density functional, B97M-V, is further assessed on a secondary test set of 212 data points, applied to several large systems including the coronene dimer and water clusters, tested for the accurate prediction of intramolecular and intermolecular geometries, verified to have a readily attainable basis set limit, and checked for grid sensitivity. Compared to existing density functionals, B97M-V is remarkably accurate for non-bonded interactions and very satisfactory for thermochemical quantities such as atomization energies, but inherits the demonstrable limitations of existing local density functionals for barrier heights.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab initio optimization of phonon drag effect for lower-temperature thermoelectric energy conversion

Significance It has been well known that the phonon drag effect—an extra electrical current induced by phonon heat flow via electron–phonon interaction—can lead to unusually high Seebeck coefficient at low temperatures. However, its use for improving thermoelectric performance has been controversial. Here, using first principles calculations we examine the phonon drag with detailed mode-specific contributions and reveal that even in heavily doped silicon at room temperature, phonon drag can still be significant, which challenges the previous belief that phonon drag vanishes in heavily doped samples. A phonon filter is designed to spectrally decouple the phonon drag from the heat conduction. Our simulation explores the coupled electron phonon transport and uncovers the possibility of optimizing the phonon drag for better thermoelectrics.

42 ENGINEERING↗

Modeling the CEBAF Injector at 200 kV: Investigating K-Long Beam Conditions with and without Wien Filter

The upcoming K-Long experiment [1] ain Hall D at Jefferson Lab presents unique beam requirements, featuring a significantly low bunch repetition rate and an unusually high bunch charge. This experiment, which utilizes the CEBAF accelerator in conjunction with the GlueX experimental setup, aims to study strange hadron spectroscopy by measuring the differential cross section and polarizations of produced hyperons such as Λ, Σ, Ξ, and Ω. By directing an intense K-Long beam towards the LD2/LH2 target, new and valuable data can be obtained. To optimize the CEBAF injector specifically for this experiment, we employed Multi-Objective Genetic Optimization (MGO) using General Particle Tracer (GPT) simulations. Through this approach, we determined the optimal magnetic elements and radiofrequency (RF) settings required to achieve a K-Long bunch charge of 0.64 pC at an energy of 200 kV. We conducted simulations with both the Wien Filter turned on and off to examine its impact on the beam. Furthermore, we investigated the transmission efficiency and beam characteristics of electron beams with varying charge per bunch through the injector, considering the simultaneous operation of all four CEBAF Halls. The results of our study offer valuable insights and guidance for optimizing the CEBAF injector not only for the Jefferson Lab K-Long experiment but also for other experiments that entail similar beam conditions.

Pokharel, Sunil↗

SU-F-T-149: Development of the Monte Carlo Simulation Platform Using Geant4 for Designing Heavy Ion Therapy Beam Nozzle

Purpose: The significant issue of particle therapy such as proton and carbon ion was a accurate dose delivery from beam line to patient. For designing the complex delivery system, Monte Carlo simulation can be used for the simulation of various physical interaction in scatters and filters. In this report, we present the development of Monte Carlo simulation platform to help design the prototype of particle therapy nozzle and performed the Monte Carlo simulation using Geant4. Also we show the prototype design of particle therapy beam nozzle for Korea Heavy Ion Medical Accelerator (KHIMA) project in Korea Institute of Radiological and Medical Science(KIRAMS) at Republic of Korea. Methods: We developed a simulation platform for particle therapy beam nozzle using Geant4. In this platform, the prototype nozzle design of Scanning system for carbon was simply designed. For comparison with theoretic beam optics, the beam profile on lateral distribution at isocenter is compared with Mont Carlo simulation result. From the result of this analysis, we can expected the beam spot property of KHIMA system and implement the spot size optimization for our spot scanning system. Results: For characteristics study of scanning system, various combination of the spot size from accerlator with ridge filter and beam monitor was tested as simple design for KHIMA dose delivery system. Conclusion: In this report, we presented the part of simulation platform and the characteristics study. This study is now on-going in order to develop the simulation platform including the beam nozzle and the dose verification tool with treatment planning system. This will be presented as soon as it is become available.

60 APPLIED LIFE SCIENCES↗

A theoretical study on the performances of thermoelectric heat engine and refrigerator with two-dimensional electron reservoirs

Theoretical thermoelectric nanophysics models of low-dimensional electronic heat engine and refrigerator devices, comprising two-dimensional hot and cold reservoirs and an interconnecting filtered electron transport mechanism have been established. The models were used to numerically simulate and evaluate the thermoelectric performance and energy conversion efficiencies of these low-dimensional devices, based on three different types of electron transport momentum-dependent filters, referred to herein as k{sub x}, k{sub y}, and k{sub r} filters. Assuming the Fermi-Dirac distribution of electrons, expressions for key thermoelectric performance parameters were derived for the resonant transport processes, in which the transmission of electrons has been approximated as a Lorentzian resonance function. Optimizations were carried out and the corresponding optimized design parameters have been determined, including but not limited to the universal theoretical upper bound of the efficiency at maximum power for heat engines, and the maximum coefficient of performance for refrigerators. From the results, it was determined that k{sub r} filter delivers the best thermoelectric performance, followed by the k{sub x} filter, and then the k{sub y} filter. For refrigerators with any one of three filters, an optimum range for the full width at half maximum of the transport resonance was found to be <2k{sub B}T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Developing the Optimal Technique for Cluster Photometric Redshift Determination: An Essential Ingredient in Measuring Dark Energy with Cluster Abundances

We received funding to fabricate and characterize dichroic beamsplitters for optical filtering applications in astronomical instrumentation. A competitive bidding process led to the selection of a vendor who has successfully fabricated subcomponents that meet our optical specifications. The final assembly of the subcomponents into a complete optical module is under way, and we expect final delivery of the part to our laboratory in May 2009.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-J-16: Planar KV Imaging Dose Reduction Study

Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen, pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality control phantoms and SNR metrics.

60 APPLIED LIFE SCIENCES↗