Simulation of DWPF Chemical Process Cell Using a Reaction Calorimeter

The Defense Waste Processing Facility (DWPF) converts liquid radioactive waste into glass using a Sludge Receipt Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in addition to other processes. The SRAT and SME processes can be simulated on a small-scale using the Mettler-Toledo Reaction Calorimeter (RC1). This equipment is able to automate the execution and monitoring of experiments involving nonradioactive chemical simulants. During the chemical processing of sludge in the SRAT process, foam begins to form and can foam over the reaction vessel. The current antifoam used at DWPF creates a risk of increased flammability and has a limited pH range. Usually, mercury is circulated back into the reaction vessel during the SRAT process, making it difficult to remove. To combat foam over, novel antifoams will be tested during the boil-up process using the RC1. To improve mercury extraction, 3D-printed coalescer columns will be tested within the Mercury Water Wash Tank (MWWT) of the RC1. Testing of Simulant Sludge Batch 6 (SB6) was performed to ensure: the sludge would form a stable foam at boiling during full SRAT/SME runs; the antifoam would reduce the amount of foam within the vessel The sludge and a Precipitate Reactor Feed Tank (PRFT) simulant with monosodium titanate (MST) were mixed separately, combined, and then heated to boiling. As shown below, the antifoam used was able to eliminate the foam within the vessel, as expected. The FormLabs Form2 3D Printer can be used to create roughly 3-inch tall and 1-inch diameter columns from clear and ceramic resins. The columns will utilize chemical and physical forces to draw the mercury out of a condensed offgas stream leaving the RC1 reaction vessel. These columns will be tested during full SRAT/SME runs on the basis of how well they are able to collect elemental mercury. In preparation for full-scale runs, the RC1 equipment was assembled onto a custom table and tested with water runs. The software used to control automation, iControl, has a user-friendly interface that allows the experiment to be altered as needed. An example of the data recorded during an experimental run is represented in Figure 1 below. Water runs were utilized as a way to prove if the RC1 system was functioning in the following areas: Boil-up rates, Chemical additions using pumps, Temperature readings, Balance readings, Probe readings, Offgas system, Agitation. Future Plans: Five novel antifoams will be tested during full SRAT/SME runs. The most effective antifoam will be utilized in DWPF's Chemical Process Cell. The design of the Mercury Extraction Coalescer can be further manipulated to increase the extraction of not only elemental mercury, but other heavy metals in environmental remediation processes as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scaled melter testing of alternative reductants for Low-Activity Waste vitrification: Melter feed properties and processing behavior

This study examines the use of boron nitride (BN) and coke dust as alternative reductants for low-activity waste vitrification in scaled melter systems, intended to enhance operational flexibility at the Hanford Waste Treatment and Immobilization Plant. The baseline reductant, sucrose, while widely considered advantageous for glass production rates, produces challenging off gas emissions during processing. Early crucible-scale testing indicated that BN and coke effectively control foaming and glass redox, while significantly reducing acetonitrile emissions. Both real tank waste and simulant waste melter feeds were tested with BN and coke in this study. Rheological properties for melter feeds with both reductants were within operational limits, although the particle size of coke should be controlled and sufficient agitation is necessary to ensure smooth operations. While promising for handling and reduction of emissions, both simulant melter feeds demonstrated lower average glass production rates in the simulant melter system compared with sucrose. In the radioactive system, the rates were more comparable to previously measured low activity waste feeds on the order of 1285 kg m 2 day −1 for BN and 1671 kg m −2 day −1 for coke. Further scale-up testing is required to interpret the processing rates in the context of the full scale melter systems and evaluate the cost-benefit impact of these reductants on efficiency and sustainability.

Rigby, Jessica C. [Pacific Northwest National Labo↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

Comparing and contrasting In-Vial and full-scale systems for sparging volatile analytes

Here, in-vial sparging was demonstrated as an effective, practical alternative to a full-scale sparging system for supporting the analysis of volatile constituents. Using elemental mercury (Hg 0 ) and toluene as representative purgeable analytes, the mass removal for various sparge configurations was measured and a reduced order model was developed and validated. In the primary experiments, Hg 0 in the sparge gas was trapped on activated carbon or gold, thermally desorbed, and quantified using atomic absorption or atomic fluorescence spectroscopy. Toluene experiments using the same in-vial sparge apparatus and sparge parameters were performed to demonstrate the applicability of the reduced order model to a broad range of compounds. Toluene removal was tracked by measuring the remaining toluene in sparged aliquots using Ultraviolet-visible (UV–Vis) spectroscopy. For the sparging, flow rates varied from 25 to 75 mL/min for periods from 0 to 30 min. Sparge performance, mass removal as a function of time, and sparge gas volume were measured for both in-vial and full-scale systems. A model based on dimensionless Henry's Law coefficient, normalized sparge gas volume, and fractional extent of equilibrium matched the experimental data for both compounds and provides a practical tool for future applications. For the conditions tested in this study, the calibrated model indicated that the sparge gas in the in-vial system reached approximately 33% of its equilibrium value before exiting the water surface, while a full-scale system reached approximately 100%. The tests validated the quality, reproducibility, and predictability of sparging performance for both full scale and in-vial sparge systems. Related factors such as waste generation, worker risk, and labor were also assessed. Full scale sparge systems provide the advantage of lower detection levels due to larger sample volume, while the in-vial sparge systems provide advantages for most other factors; including automatability, reducing secondary wastes, lessening the need to clean and check the sparge apparatus, and lowering labor and costs. The data and associated reduced order model support continued development and deployment of in-vial sparge platforms as a practical option for analysis of purgeable analytes such as volatile organic compounds and volatile metals/organometallics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PELICAN Status Report for Year 2021

The Pressure Drop Experimental Loop for Investigations of Core Assemblies in Advanced Nuclear Reactors, PELICAN, is a novel experimental facility designed and constructed to recreate the prototypic full scale hydraulic flow conditions for the Versatile Test Reactor (VTR) currently under development by the U.S. Department of Energy. To support VTR design efforts, PELICAN is used to replicate VTR’s primary heat transport system (PHTS) in the core assembly region. The measurement objectives for data generated from this test facility are to mimic the prototypic VTR assembly and to meet the validation needs for code calculations and simulations of the reference design for the VTR core. These objectives focus on the need to validate pressure drop results across the various segments of the fuel assembly, including the axial reflectors, fuel, and transition regions, as they relate directly to the pumping power and safety behavior of the reactor. In the following sections, the major milestones for the experimental work performed on PELICAN over the calendar year (CY) 2021 are presented. In the next section, we discuss the assembly and shakedown testing of the facility. In Section 3, an analysis of the errors in the major measurements is performed. In Section 4 and 5 we present the results from the first set of test articles placed inside the loop. The design of the remaining test articles as part of the full assembly are shown in Section 6 and the conclusion and path forward for the following year, CY22 is given in the final section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization and Parallelization of the Thermal-Hydraulic Sub-channel Code CTF for High-Fidelity Multi-physics Applications

This paper describes major improvements to the computational infrastructure of the CTF sub-channel code so that full-core sub-channel-resolved simulations can now be performed in much shorter run-times, either in stand-alone mode or as part of coupled-code multi-physics calculations. These improvements support the goals of the Department Of Energy (DOE) Consortium for Advanced Simulations of Light Water (CASL) Energy Innovation Hub to develop high fidelity multi-physics simulation tools for nuclear energy design and analysis. A set of serial code optimizations--including fixing computational inefficiencies, optimizing the numerical approach, and making smarter data storage choices--are first described and shown to reduce both execution time and memory usage by about a factor of ten. Next, a Single Program Multiple Data (SPMD) parallelization strategy targeting distributed memory Multiple Instruction Multiple Data (MIMD) platforms and utilizing domain-decomposition is presented. In this approach, data communication between processors is accomplished by inserting standard MPI calls at strategic points in the code. The domain decomposition approach implemented assigns one MPI process to each fuel assembly, with each domain being represented by its own CTF input file. The creation of CTF input files, both for serial and parallel runs, is also fully automated through use of a pre-processor utility that takes a greatly reduced set of user input over the traditional CTF input file. To run CTF in parallel, two additional libraries are currently needed; MPI, for inter-processor message passing, and the Parallel Extensible Toolkit for Scientific Computation (PETSc), which is leveraged to solve the global pressure matrix in parallel. Results presented include a set of testing and verification calculations and performance tests assessing parallel scaling characteristics up to a full core, sub-channel-resolved model of Watts Bar Unit 1 under hot full-power conditions (193 17x17 assemblies, ~56,000 pins, ~59,000 sub-channels, ~2.8 million thermal-hydraulic (TH) control volumes). Results demonstrate that CTF can now perform full core analysis (not previously possible due to excessively long runtimes and memory requirements) on the order of 20 minutes. This new capability is not only useful to standalone CTF users, but is also being leveraged in support of coupled code multi-physics calculations being done in the CASL program.

COBRA-TF↗

Pilot testing of a membrane system for postcombustion CO 2 capture

This final report summarizes work conducted for the U.S. Department of Energy, National Energy Technology Laboratory (DOE) to scale up an efficient post-combustion CO 2 capture membrane process to the small pilot test stage (award number DE-FE0005795). The primary goal of this research program was to design, fabricate, and operate a membrane CO 2 capture system to treat coal-derived flue gas containing 20 tonnes CO 2 /day (20 TPD). Membrane Technology and Research (MTR) conducted this project in collaboration with Babcock and Wilcox (B&W), the Electric Power Research Institute (EPRI), WorleyParsons (WP), the Illinois Sustainable Technology Center (ISTC), Enerkem (EK), and the National Carbon Capture Center (NCCC). In addition to the small pilot design, build and slipstream testing at NCCC, other project efforts included laboratory membrane and module development at MTR, validation field testing on a 1 TPD membrane system at NCCC, boiler modeling and testing at B&W, a techno-economic analysis (TEA) by EPRI/WP, a case study of the membrane technology applied to a ~20 MWe power plant by ISTC, and an industrial CO 2 capture test at an Enerkem waste-to-biofuel facility. The 20 TPD small pilot membrane system built in this project successfully completed over 1,000 hours of operation treating flue gas at NCCC. The Polaris™ membranes used on this system demonstrated stable performance, and when combined with over 10,000 hours of operation at NCCC on a 1 TPD system, the risk associated with uncertainty in the durability of postcombustion capture membranes has been greatly reduced. Moreover, next-generation Polaris membranes with higher performance and lower cost were validation tested on the 1 TPD system. The 20 TPD system also demonstrated successful operation of a new low-pressure-drop sweep module that will reduce parasitic energy losses at full scale by as much as 10 MWe. In modeling and pilot boiler testing, B&W confirmed the viability of CO 2 recycle to the boiler as envisioned in the MTR process design. The impact of this CO 2 recycle on boiler efficiency was quantified and incorporated into a TEA of the membrane capture process applied to a full-scale power plant. As with previous studies, the TEA showed the membrane process to be lower cost than the conventional solvent capture process even at 90% CO 2 capture. A sensitivity study indicates that the membrane capture cost decreases significantly if the 90% capture requirement is relaxed. Depending on the process design, a minimum capture cost is achieved at 30-60% capture, values that would meet proposed CO 2 emission regulations for coal-fired power plants. In summary, this project has successfully advanced the MTR membrane capture process through small pilot testing (technology readiness level 6). The technology is ready for future scale-up to the 10 MWe size.

01 COAL, LIGNITE, AND PEAT↗

Optimization of Preprocessing and Densification of Sorghum Stover at Full-scale Operation

Transportation costs can be a prohibitive step in bringing biomass to a preprocessing location or biofuel refinery. One alternative to transporting biomass in baled or loose format to a preprocessing location, is to utilize a mobile preprocessing system that can be relocated to various locations where biomass is stored, preprocess and densify the biomass, then ship it to the refinery as needed. The Idaho National Laboratory has a full scale 'Process Demonstration Unit' PDU which includes a stage 1 grinder, hammer mill, drier, pellet mill, and cooler with the associated conveyance system components. Testing at bench and pilot scale has been conducted to determine effects of moisture on preprocessing, crop varieties on preprocessing efficiency and product quality. The INLs PDU provides an opportunity to test the conclusions made at the bench and pilot scale on full industrial scale systems. Each component of the PDU is operated from a central operating station where data is collected to determine power consumption rates for each step in the process. The power for each electrical motor in the system is monitored from the control station to monitor for problems and determine optimal conditions for the system performance. The data can then be viewed to observe how changes in biomass input parameters (moisture and crop type for example), mechanical changes (screen size, biomass drying, pellet size, grinding speed, etc.,), or other variations effect the power consumption of the system. Sorgum in four foot round bales was tested in the system using a series of 6 different screen sizes including: 3/16 in., 1 in., 2 in., 3 in., 4 in., and 6 in. The effect on power consumption, product quality, and production rate were measured to determine optimal conditions.

09 BIOMASS FUELS↗

Development and thermal performance verification of composite insulation boards containing foam-encapsulated vacuum insulation panels

High-performance thermal insulation is a critical need for buildings. This article presents the development and thermal characterization of composite foam insulation boards containing low-cost vacuum insulation cores. The composite foam-vacuum insulation boards were created in a semi-automatic operation in a foam insulation manufacturing plant. The low-cost vacuum insulation is a new technology called modified atmosphere insulation. The production process of modified atmosphere insulation is much simpler than traditional vacuum insulation manufacturing, and it has the potential for significant cost reduction at the same thermal performance. Prototypes of small- and full-scale composite insulation boards were created for testing and evaluation under laboratory and natural weatherization conditions. The laboratory tests showed that the overall thermal resistance of the composite insulation board is at least twice that of current rigid foam insulation used in building envelope. Lastly, ongoing test of the composite insulation in a natural exposure test facility indicates that the high thermal performance was retained through handling and installation as well as natural aging over a period of one and a half years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototyping phase of the high heat flux scraper element of Wendelstein 7-X

The water-cooled high heat flux scraper element aims to reduce excessive heat loads on the target element ends of the actively cooled divertor of Wendelstein 7-X. Its purpose is to intercept some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper element has 24 identical plasma facing components (PFCs) divided into 6 modules. One module has 4 PFCs hydraulically connected in series by 2 water boxes. A PFC, 247 mm long and 28 mm wide, has 13 monoblocks made of CFC NB31 bonded by hot isostatic pressing onto a CuCrZr cooling tube equipped with a copper twisted tape. 4 full-scale prototypes of PFCs have been successfully tested in the GLADIS facility up to 20 MW/m 2 . The difference observed between measured and calculated surface temperatures is probably due to the inhomogeneity of CFC properties. The design of the water box prototypes has been detailed to allow the junction between the cooling pipe of the PFCs and the water boxes by internal orbital welding. In conclusion, the prototypes are presently under fabrication.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid continuum–molecular modelling of multiscale internal gas flows

We develop and apply an efficient multiscale method for simulating a large class of low-speed internal rarefied gas flows. The method is an extension of the hybrid atomistic–continuum approach proposed by Borg et al. (2013) [28] for the simulation of micro/nano flows of high-aspect ratio. The major new extensions are: (1) incorporation of fluid compressibility; (2) implementation using the direct simulation Monte Carlo (DSMC) method for dilute rarefied gas flows, and (3) application to a broader range of geometries, including periodic, non-periodic, pressure-driven, gravity-driven and shear-driven internal flows. The multiscale method is applied to micro-scale gas flows through a periodic converging–diverging channel (driven by an external acceleration) and a non-periodic channel with a bend (driven by a pressure difference), as well as the flow between two eccentric cylinders (with the inner rotating relative to the outer). In all these cases there exists a wide variation of Knudsen number within the geometries, as well as substantial compressibility despite the Mach number being very low. For validation purposes, our multiscale simulation results are compared to those obtained from full-scale DSMC simulations: very close agreement is obtained in all cases for all flow variables considered. Our multiscale simulation is an order of magnitude more computationally efficient than the full-scale DSMC for the first and second test cases, and two orders of magnitude more efficient for the third case.

97 MATHEMATICS AND COMPUTING↗

Steel–Concrete Composite Pressure Vessels for Hydrogen Storage at High Pressures

The need to store large quantities of hydrogen in large diameter steel vessels under high pressures results in shell thicknesses that are too large to produce by most steel mills and not practical to fabricate. Accordingly, a research program was undertaken by Oak Ridge National Laboratory to develop a new concept of combining steel with concrete to construct such vessels economically and practically. The concept is to fabricate vessels where the steel shell thickness is approximately one half that required to resist the hoop forces due to internal pressure. As such, the steel shell is designed to carry the full amount of the longitudinal forces in the vessel but only one half of the hoop loads due to internal pressure. The other half of the hoop loads is carried by a prestressed and reinforced concrete shell. In large diameter vessels, the cost of the shell can further be reduced by using layered steel shell construction rather than solid-wall construction. Such shell construction has also the added advantage of easily venting the hydrogen that permeates through the steel shell directly to the atmosphere through vent holes. This mechanism prevents the hydrogen from damaging the steel shell. The theoretical formulation of the steel concrete shell design is presented in this paper. Finally, in addition, details of a full-scale mock up vessel designed, fabricated, and tested to prove the proposed methodology are given.

42 ENGINEERING↗

Experimental Verification of ABS Concrete Design Methodology Applied to the Design of the First Commercial Scale Floating Offshore Wind Turbine in the United States

The abundance of consistent high strength winds off the world’s coastlines and the close proximity to dense population centers has led to development of innovative marine structures to support wind turbines to capture this energy resource. Off the US coast, 60% of the offshore wind lies in deep water (greater than 60m) where the development of Floating Offshore Wind Turbine (FOWT) hull technology will likely be required in lieu of fixed bottom technology such as jacket structures. The United States National Renewable Energy Laboratory (NREL) and the offshore wind community commonly refer to 60m as the transition point between fixed bottom structures and floating structures due to economic reasons. Floating wind turbines deployed in the harsh offshore marine environment require the use of materials that are cost-effective, corrosion resistant, require little maintenance and are highly durable. This has led the University of Maine to develop a concrete hull technology called VolturnUS for full-scale 6MW FOWTs. In this work, experimental testing was conducted to verify the performance of the concrete under operational, serviceability, and extreme loading conditions as required by the American Bureau of Shipping Guide for Building and Classing Floating Offshore Wind Turbines. Here, the testing included structural testing sub-components of the hull and served as experimental verification of American Bureau of Shipping (ABS) concrete design methodology which is currently approved and being used to design the first commercial scale FOWTs in the United States. Two 6MW wind turbines supported on VolturnUS concrete hulls will be used for the New England Aqua Ventus I project. The project is planned to be deployed and connected to the grid by 2019 in the Northeast U.S. and is funded by the US Department of Energy.

Concretes↗

Unsupervised acoustic detection of fatigue-induced damage modes from wind turbine blades

This paper proposes a new in-situ damage detection approach for wind turbine blades, which leverages blade-internal non-stationary acoustic pressure fluctuations caused by the mechanical loading as the main source of excitation. This acoustic excitation was leveraged for the detection of fatigue-related damage modes on a full-scale wind turbine blade undergoing edgewise fatigue testing. An unsupervised, data-driven structural health monitoring strategy was developed to learn the normal cavity-internal acoustic sequences generated by the blade’s load cycles and to detect damage-related anomalies in the context of those sequences. A linear cepstral-coefficient based feature set was used to characterize the cavity-internal acoustics and LSTM-autoencoders were trained to accurately reconstruct healthy-case sequences. The reconstruction error was then used to characterize anomalous acoustic patterns within the blade cavity. The technique was able to detect a damage event earlier than a strain-based system by 120,000 load cycles.

17 WIND ENERGY↗

Disruption Mitigation System Developments and Design for ITER

A disruption mitigation system (DMS) is under design for ITER to inject sufficient material deeply into the plasma for rapid plasma thermal shutdown and collisional suppression of any resulting runaway electrons. Progress on the development and design of both a shattered pellet injector (SPI) that produces large solid cryogenic pellets to provide reliable deep penetration of material and a fast opening high flow rate gas valve for massive gas injection (MGI) is presented. Cryogenic pellets of deuterium and neon up to 25 mm in size have been formed and accelerated with a prototype injector and a full scale prototype MGI valve is now in testing. Implications of the design with respect to response time and reliability at the proposed injector locations on ITER are discussed.

Baylor, Larry↗

Performance and flexibility improvements of Staged Pressurized Oxy-Combustion

Staged Pressurized Oxy-Combustion (SPOC) is a low-carbon coal combustion power technology being developed by Washington University in St. Louis (WUSTL). Oxy-combustion plants enable straightforward capture of carbon dioxide (CO 2 ) by removing most of the nitrogen in the combustion air prior to use, thereby burning fuel in near-pure oxygen instead of air, producing a flue gas containing primarily CO 2 and water. CO 2 capture at amounts > 90% is possible, often using cryogenic air separation. Oxy-combustion typically relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. Also, the process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing for recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is over 3 percentage points greater than traditional atmospheric-pressure oxy-combustion, and 7 percentage points greater than the post combustion variant, representing a step-change improvement over first-generation capture technologies. To further develop the concept, WUSTL and the Electric Power Research Institute, Inc., organized a project with American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to investigate a practicable and workable boiler design. The team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants due to the staged nature of the heat release. With increasing intermittent renewable generator contribution, on-demand generators need to be highly flexible to participate in the future energy market, requiring extensive operation at reduced load. Conventional coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and main steam at reduced loads. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. The results of this project show the SPOC process is capable of exceptional turndown, both on a stage basis and with the ability to bypass entire stages. Oxygen-supply flexibility was also investigated, as this is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. A boiler design concept assessment was conducted and was focused on delivering compact and constructible design. The assessment checked appropriate tube operating metal temperatures at full load and at lower operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. Combustion testing in the 100-kWth pressurized combustion test rig at WUSTL was carried out to validate the combustion, heat flux profiles and burnout at multiple loads. Combustion parameters investigated were flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. The results of these tests formed the basis of a full-scale boiler design that will encompass improvements in both efficiency and flexibility over conventional oxy-combustion processes. The air separation unit flexibility was investigated, and associated cost implications were addressed. Detailed economic assessment results for a 550 MWe net power block are also provided, allowing for a comparison against the baseline NETL oxy-combustion and post combustion capture cases.

20 FOSSIL-FUELED POWER PLANTS↗

Survey of techniques for reduction of wind turbine blade trailing edge noise.

Aerodynamic noise from wind turbine rotors leads to constraints in both rotor design and turbine siting. The primary source of aerodynamic noise on wind turbine rotors is the interaction of turbulent boundary layers on the blades with the blade trailing edges. This report surveys concepts that have been proposed for trailing edge noise reduction, with emphasis on concepts that have been tested at either sub-scale or full-scale. These concepts include trailing edge serrations, low-noise airfoil designs, trailing edge brushes, and porous trailing edges. The demonstrated noise reductions of these concepts are cited, along with their impacts on aerodynamic performance. An assessment is made of future research opportunities in trailing edge noise reduction for wind turbine rotors.

17 WIND ENERGY↗

Thermal Test of 29 mm and 12 mm Targets

NorthStar medical isotopes are planning to produce important medical radioisotope molybdenum-99 (Mo-99) through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target),which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. To validate calculation models, the team performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF). This report describes additional tests for two target designs: a full-scale target 29 millimeters in diameter and a scaled-down version, 12 millimeters in diameter. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.