Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Study of the Imaging Capabilities of SPIRIT/SPECS Concept Interferometers

Several new space science mission concepts under development at NASA-GSFC for astronomy are intended to carry out synthetic imaging using Michelson interferometers or direct (Fizeau) imaging with sparse apertures. Examples of these mission concepts include the Stellar Imager (SI), the Space Infrared Interferometric Telescope (SPIRIT), the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS), and the Fourier-Kelvin Stellar Interferometer (FKSI). We have been developing computer-based simulators for these missions. These simulators are aimed at providing a quantitative evaluation of the imaging capabilities of the mission by modeling the performance on different realistic targets in terms of sensitivity, angular resolution, and dynamic range. Both Fizeau and Michelson modes of operation can be considered. Our work is based on adapting a computer simulator called imSIM which was initially written for the Space Interferometer Mission in order to simulate the imaging mode of new missions such as those listed. This report covers the activities we have undertaken to provide a preliminary version of a simulator for the SPIRIT mission concept.

Allen, Ronald J.↗

Potential dependent spectroelectrochemistry of electrofluorogenic dyes on indium–tin oxide

Indium-tin oxide (ITO) is used in a variety of applications due to its electrical conductivity and optical transparency. Moreover, ITO-coated glass is a common working electrode for spectroelectrochemistry. Thus, the ITO substrates should exhibit well-understood spectroscopic characteristics. Here, we report anomalous potential-dependent luminescence emission from three structurally dissimilar electrofluorogenic probe on ITO-coated glass. The three probes, flavin mononucleotide, resorufin, and Nile blue, show the expected fluorescence modulation between their oxidized, emissive forms and their reduced, nonfluorescent forms at low laser irradiance and/or high concentrations. However, at high irradiance and/or low concentration, the emission intensity increases at reducing potentials, contrary to expectations. In addition, a strong interplay between probe molecule concentration and laser irradiance is observed. We attribute the anomalous behavior to a combination of (1) irradiance-dependent ITO carrier dynamics, and (2) interaction of the fluorescent probe with ITO at reducing potentials resulting in a charge transfer state with altered emission behavior. Thus, the potential- and irradiance-dependent behavior of ITO and the resulting charge transfer state may not only interfere with the observation of potential-dependent fluorescence from redox probes but can completely reverse the polarity of the potential-dependent luminescence, especially at high irradiance and low concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar water splitting Pt-nanoparticle photosystem I thylakoid systems: Catalyst identification, location and oligomeric structure

In this study, photosynthetic conversion of light energy into chemical energy occurs in sheet-like membrane-bound compartments called thylakoids and is mediated by large integral membrane protein-pigment complexes called reaction centers (RCs). Oxygenic photosynthesis of higher plants, cyanobacteria and algae requires the symbiotic linking of two RCs, photosystem II (PSII) and photosystem I (PSI), to split water and assimilate carbon dioxide. Worldwide there is a large research investment in developing RC-based hybrids that utilize the highly evolved solar energy conversion capabilities of RCs to power catalytic reactions for solar fuel generation. Of particular interest is the solar-powered production of H 2 , a clean and renewable energy source that can replace carbonbased fossil fuels and help provide for ever-increasing global energy demands. Recently, we developed thylakoid membrane hybrids with abiotic catalysts and demonstrated that photosynthetic Z-scheme electron flow from the light-driven water oxidation at PSII can drive H 2 production from PSI. One of these hybrid systems was created by self-assembling Pt-nanoparticles (PtNPs) with the stromal subunits of PSI that extend beyond the membrane plane in both spinach and cyanobacterial thylakoids. Using PtNPs as site-specific probe molecules, we report the electron microscopic (EM) imaging of oligomeric structure, location and organization of PSI in thylakoid membranes and provide the first direct visualization of photosynthetic Z-scheme solar water-splitting biohybrids for clean H 2 production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carrier gradients and the role of charge selective contacts in lateral heterojunction all back contact perovskite solar cells

Realizing photovoltaic devices that achieve the full potential of the metal halide perovskite material will require improved insight regarding the role of selective contacts and how key interfaces operate when mobile defects are present. However, measuring interface properties in typical device stacks where the perovskite layer is thin and sandwiched between two contacts has been a challenge. Here, we fabricate p-i-n and p-n lateral heterojunctions with nickel oxide/titanium oxide all back contacts, permitting us to employ a comprehensive analysis approach, including ultraviolet and X-ray photoemission spectroscopy (UPS/XPS), angle-resolved X-ray absorption spectroscopy (XAS), Kelvin probe force microscopy (KPFM), surface photovoltage (SPV), hyperspectral imaging (HSI), and time-resolved fluorescence lifetime imaging microscopy (TR-FLIM) to discern the role of selective contacts. Specifically, we tune the selectivity of the contacts, changing the gradient in the carrier concentration across the surface of the active layer, which is connected to carrier extraction at the buried interface, and thus the device functionality.

25 ENERGY STORAGE↗

Faraday rotation study of plasma bubbles in GeV wakefield accelerators

We visualize plasma bubbles driven by 0.67 PW laser pulses in a plasma of density ne≈5×1017cm−3 by imaging Faraday rotation patterns imprinted on linearly polarized probe pulses of wavelength λpr=1.05 μm and duration τpr=2 or 1 ps that cross the bubble's path at right angles. When the bubble captures and accelerates tens to hundreds of pC of electron charges, we observe two parallel streaks of length cτpr straddling the drive pulse propagation axis, separated by ∼45 μm, in which probe polarization rotates by 0.3° to more than 5° in opposite directions. Accompanying simulations show that they result from Faraday rotation within portions of dense bubble side walls that are pervaded by the azimuthal magnetic field of accelerating electrons during the probe transit across the bubble. Analysis of the width of the streaks shows that quasi-monoenergetic high-energy electrons and trailing lower energy electrons inside the bubble contribute distinguishable portions of the observed signals, and relativistic flow of sheath electrons suppresses Faraday rotation from the rear of the bubble. The results demonstrate favorable scaling of Faraday rotation diagnostics to 40× lower plasma density than previously demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ecosystem consequences of a nitrogen-fixing proto-organelle

Microscale symbioses can be critical to ecosystem functions, but the mechanisms of these interactions in nature are often cryptic. Here, we use a combination of stable isotope imaging and tracing to reveal carbon (C) and nitrogen (N) exchanges among three symbiotic primary producers that fuel a salmon-bearing river food web. Bulk isotope analysis, nanoSIMS (secondary ion mass spectrometry) isotope imaging, and density centrifugation for quantitative stable isotope probing enabled quantification of organism-specific C- and N-fixation rates from the subcellular scale to the ecosystem. After winters with riverbed-scouring floods, the macroalga Cladophora glomerata uses nutrients in spring runoff to grow streamers up to 10 m long. During summer flow recession, riverine N concentrations wane and Cladophora becomes densely epiphytized by three species of Epithemia, diatoms with N-fixing endosymbionts (proto-organelles) descended from a free-living Crocosphaera cyanobacterium. Over summertime epiphyte succession on Cladophora, N-fixation rates increased as Epithemia spp. became dominant, Cladophora C-fixation declined to near zero, and Epithemia C-fixation increased. Carbon transfer to caddisflies grazing on Cladophora with high densities of Epithemia was 10-fold higher than C transfer to caddisflies grazing Cladophora with low Epithemia loads. In response to demand for N, Epithemia allocates high levels of newly fixed C to its endosymbiont. Consequently, these endosymbionts have the highest rates of C and N accumulation of any taxon in this tripartite symbiosis during the biologically productive season and can produce one of the highest areal rates of N-fixation reported in any river ecosystem.

Marks, Jane C. [Northern Arizona Univ., Flagstaff,↗

Diocotron modes in pure electron plasmas in the APEX levitating dipole trap

Abstract Observations of persistent toroidal modes in dipole-trapped pure electron plasmas are presented. Non-neutral electron plasmas were confined by the poloidal magnetic field of the APEX (A Positron Electron eXperiment) levitating dipole trap. The negative bias of the electron emitter was gated to control the filling time. Large amplitude, narrow-band oscillations were consistently observed in wall probe measurements after the fill. The oscillatory image-charge currents induced by the trapped electron plasma typically persisted for many seconds with fundamental frequencies, f 0 = 50 to 500 kHz, that scale with the E → × B → drift velocity. We attribute this feature to the dipole-equivalent of the diocotron mode that is commonly observed in non-neutral plasmas in linear traps.

Deller, A. (ORCID:0000000234301501)↗

Detecting cosmic strings with lensed fast radio bursts

Correlated red noise recently reported from pulsar timing observations may be an indication of stochastic gravitational waves emitted by cosmic strings that formed during a primordial phase transition near the grand unification energy scale. Unfortunately, known probes of cosmic strings, namely the cosmic microwave background anisotropies and string lensing of extragalactic galaxies, are not sensitive enough for low dimensionless string tensions of Gμc -2 = 10 -10 – 10 -7 (where the tension μ is the string energy per unit length) that are needed to explain this putative signal. We show that strong gravitational lensing of fast radio bursts (FRBs) by cosmic strings is a potentially unambiguous avenue to probe that range of string tension values. The image pair of string lensing are expected to have identical magnification factor and parity, and have a typical time delay of ~10 2 (Gμc -2 /10 -8 ) 2 s. Here, the unique spectral fingerprint of each FRB, as well as the possibility to detect correlations in the time series of the electric field of the radio waves, will enable verification of the string lensing interpretation. Very-long-baseline interferometry observations can spatially resolve the image pair and provide a lower bound on the string tension based on the image separation. We calculate the FRB lensing rate as a function of the FRB detection number for several different models of the FRB redshift distribution. We find that a survey detecting ~10 5 FRBs, in line with estimates for the detection rate of the forthcoming survey CHORD, can uncover a strong lensing event for a string tension of Gμc -2 ≃ 10 -7 . Larger FRB surveys, such as Phase 2 of the Square Kilometre Array, have the potential to significantly improve the sensitivity on the string tension to Gμc -2 ≃ 10 -9 .

79 ASTRONOMY AND ASTROPHYSICS↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

Quantitative analysis method for multi-color microscopy

We developed an analysis framework for quantitatively interpreting results from multi-color fluorescence microscopy data. When the emission signal from fluorescent probes (i.e. from biological microscopy or in single-particle microscopy) is spectrally separated before detection, the resulting signals contain information about the strengths of each probe. We built a model to deconvolve the raw data into quantitative descriptions of either of the wavelength of a single probe or the relative strengths among multiple probes. This approach requires only spectrally separating the image data into two or more channels, as opposed to fully resolving the spectral profile, thus allowing other microscopy techniques to be used simultaneously. Our analysis framework incorporates the response features of the optical and imaging elements used to produce the spectral separation, yielding highly quantitative interpretations of the underlying behaviors that give rise to the data.

Ryan, Duncan↗

Interface potentials inside solid-state batteries: Origins and implications

Interface resistance has become a significant bottleneck for solid-state batteries (SSBs). Most studies of interface resistance have focused on extrinsic mechanisms such as interface reactions and imperfect contact between electrodes and solid electrolytes. Interface potentials are an important intrinsic mechanism that is often ignored. Here, we highlight Kelvin probe force microscopy (KPFM) as a tool to image the local potential at interfaces inside SSBs, examining the existing literature and discussing challenges in interpretation. Drawing analogies with electron transport in metal/semiconductor interfaces, we showcase a formalism that predicts intrinsic ionic resistance based on the properties of the contacting phases, and we emphasize that future battery designs should start from material pairs with low intrinsic resistance. Here, we conclude by outlining future directions in the study of interface potentials through both theory and experiment.

25 ENERGY STORAGE↗

Atomic Force Microscopy to Characterize Antimicrobial Peptide-Induced Defects in Model Supported Lipid Bilayers

Antimicrobial peptides (AMPs) interact with bacterial cell membranes through a variety of mechanisms, causing changes extending from nanopore formation to microscale membrane lysis, eventually leading to cell death. Several AMPs also disrupt mammalian cell membranes, despite their significantly different lipid composition and such collateral hemolytic damage hinders the potential therapeutic applicability of the AMP as an anti-microbial. Elucidating the mechanisms underlying the AMP–membrane interactions is challenging due to the variations in the chemical and structural features of the AMPs, the complex compositional variations of cell membranes and the inadequacy of any single experimental technique to comprehensively probe them. (1) Background: Atomic Force Microscopy (AFM) imaging can be used in combination with other techniques to help understand how AMPs alter the orientation and structural organization of the molecules within cell membranes exposed to AMPs. The structure, size, net charge, hydrophobicity and amphipathicity of the AMPs affect how they interact with cell membranes of differing lipid compositions. (2) Methods: Our study examined two different types of AMPs, a 20-amino acid, neutral, α-helical (amphipathic) peptide, alamethicin, and a 13-amino acid, non-α-helical cationic peptide, indolicidin (which intramolecularly folds, creating a hydrophobic core), for their interactions with supported lipid bilayers (SLBs). Robust SLB model membranes on quartz supports, incorporating predominantly anionic lipids representative of bacterial cells, are currently not available and remain to be developed. Therefore, the SLBs of zwitterionic egg phosphatidylcholine (PC), which represents the composition of a mammalian cell membrane, was utilized as the model membrane. This also allows for a comparison with the results obtained from the Quartz Crystal Microbalance with Dissipation (QCM-D) experiments conducted for these peptides interacting with the same zwitterionic SLBs. Further, in the case of alamethicin, because of its neutrality, the lipid charge may be less relevant for understanding its membrane interactions. (3) Results: Using AFM imaging and roughness analysis, we found that alamethicin produced large, unstable defects in the membrane at 5 µM concentrations, and completely removed the bilayer at 10 µM. Indolicidin produced smaller holes in the bilayer at 5 and 10 µM, although they were able to fill in over time. The root-mean-square (RMS) roughness values for the images showed that the surface roughness caused by visible defects peaked after peptide injection and gradually decreased over time. (4) Conclusions: AFM is useful for helping to uncover the dynamic interactions between different AMPs and cell membranes, which can facilitate the selection and design of more efficient AMPs for use in therapeutics and antimicrobial applications.

Swana, Kathleen W.↗

The development of laser speckle or particle image displacement velocimetry. Part 1: The role of photographic parameters

One of the difficult problems in experimental fluid dynamics remains the determination of the vorticity field in fluid flows. Recently, a novel velocity measurement technique, commonly known as Laser Speckle or Particle Image Displacement Velocimetry became available. This technique permits the simultaneous visualization of the 2 dimensional streamline pattern in unsteady flows and the quantification of the velocity field. The main advantage of this new technique is that the whole 2 dimensional velocity field can be recorded with great accuracy and spatial resolution, from which the instantaneous vorticity field can be easily obtained. A apparatus used for taking particle displacement images is described. Local coherent illumination by the probe laser beam yielded Young's fringes of good quality at almost every location of the flow field. These fringes were analyzed and the velocity and vorticity fields were derived. Several conclusions drawn are discussed.

Lourenco, L. M. M.↗

Phosphor Scanner For Imaging X-Ray Diffraction

Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

Carter, Daniel C.↗

The cyclotron energization through auroral wave experiments (CENTAUR 2B)

The CENTAUR 2B mission, a dual payload program, is in many aspects the same as the previous missions from Cape Perry and Norway in 1985. It was planned that these payloads would be launched from Andoya, Norway, Nov. 1989 from the Universal II launcher. The payloads are identical, but would have been launched at different azimuths as far north and as far west as possible. Particle experiments include the angular resolving energy analyzer (AREA), the fast ion mass spectrometer (FIMS), the spectrographic particle images (SPI), and finally, the differential ion flux probe (DIFP). SwRI was responsible for the scientific payload, which includes the power supplies, the power supply interfacing, the manipulating of the data from the instruments to format it for the telemetry system, all mechanical structure and restraint mechanisms, and the payload subskin. The status of the various components of this program is given.

Winningham, J. D.↗

The Next Century Astrophysics Program

The Astrophysics Division within the NASA Office of Space Science and Applications (OSSA) has defined a set of major and moderate missions that are presently under study for flight sometime within the next 20 years. These programs include the: Advanced X Ray Astrophysics Facility; X Ray Schmidt Telescope; Nuclear Astrophysics Experiment; Hard X Ray Imaging Facility; Very High Throughput Facility; Gamma Ray Spectroscopy Observatory; Hubble Space Telescope; Lunar Transit Telescope; Astrometric Interferometer Mission; Next Generation Space Telescope; Imaging Optical Interferometer; Far Ultraviolet Spectroscopic Explorer; Gravity Probe B; Laser Gravity Wave Observatory in Space; Stratospheric Observatory for Infrared Astronomy; Space Infrared Telescope Facility; Submillimeter Intermediate Mission; Large Deployable Reflector; Submillimeter Interferometer; and Next Generation Orbiting Very Long Baseline Interferometer.

Swanson, Paul N.↗

The TERESA project: from space research to ground tele-echography

Ultrasound examinations represent one of the major diagnostic modalities of future healthcare. They are currently used to support medical space research but require a high skilled operator for both probe positioning on the patient's skin and image interpretation. TERESA is a tele-echography project that proposes a solution to bring astronauts and remotely located patients on ground quality ultrasound examinations despite the lack of a specialist at the location of the wanted medical act.

Space Flight/instrumentation↗