Search NASA⌕ Search

SEARCH · Search NASA

Results for “iterative method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Matrix Methods for Solving Hartree-Fock Equations in Atomic Structure Calculations and Line Broadening

Atomic structure of N-electron atoms is often determined by solving the Hartree-Fock equations, which are a set of integro-differential equations. The integral part of the Hartree-Fock equations treats electron exchange, but the Hartree-Fock equations are not often treated as an integro-differential equation. The exchange term is often approximated as an inhomogeneous or an effective potential so that the Hartree-Fock equations become a set of ordinary differential equations (which can be solved using the usual shooting methods). Because the Hartree-Fock equations are an iterative-refinement method, the inhomogeneous term relies on the previous guess of the wavefunction. In addition, there are numerical complications associated with solving inhomogeneous differential equations. This work uses matrix methods to solve the Hartree-Fock equations as an integro-differential equation. It is well known that a derivative operator can be expressed as a matrix made of finite-difference coefficients; energy eigenvalues and eigenvectors can be obtained by using linear-algebra packages. The integral (exchange) part of the Hartree-Fock equation can be approximated as a sum and written as a matrix. The Hartree-Fock equations can be solved as a matrix that is the sum of the differential and integral matrices. We compare calculations using this method against experiment and standard atomic structure calculations. This matrix method can also be used to solve for free-electron wavefunctions, thus improving how the atoms and free electrons interact. This technique is important for spectral line broadening in two ways: it improves the atomic structure calculations, and it improves the motion of the plasma electrons that collide with the atom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a tomographic reconstruction method for axisymmetric D α emission profiles in the ITER plasma boundary

A tomographic method for reconstructing the axially symmetric D α emission profile in the ITER scrape-off layer and divertor from D α intensity measurements in the fields of view (FoV) of Vis/IR TV and Divertor Impurity Monitor diagnostics is under development. The method takes into account the strong background signal due to stray light from divertor produced by reflections from the metal wall of the vacuum chamber. The method allows to filter out the reflections in D α signals measured in the main chamber. Here, the accuracy of this method is tested within the framework of a synthetic diagnostic, which uses the Raysect and Cherab numerical codes for ray-tracing simulations. The D α emission profiles, simulated with the SOLPS and OEDGE codes, are used as synthetic experimental data. Uncertainty in light reflection properties of the first wall (FW) is the major factor affecting the accuracy of the D α emission reconstruction. The dependence on the uncertainty in the FW surface roughness and on the ratio of diffusive to specular reflection of the error in recovering useful D α signals (the direct light without reflections) in the FoV of the ITER main chamber H-alpha and Visible Spectroscopy Diagnostic is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Macromolecular phasing using diffraction from multiple crystal forms

A phasing algorithm for macromolecular crystallography is proposed that utilizes diffraction data from multiple crystal forms – crystals of the same molecule with different unit-cell packings (different unit-cell parameters or space-group symmetries). The approach is based on the method of iterated projections, starting with no initial phase information. The practicality of the method is demonstrated by simulation using known structures that exist in multiple crystal forms, assuming some information on the molecular envelope and positional relationships between the molecules in the different unit cells. With incorporation of new or existing methods for determination of these parameters, the approach has potential as a method for ab initio phasing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Acceleration of GPU-based Krylov solvers via data transfer reduction

Krylov subspace iterative solvers are often the method of choice when solving large sparse linear systems. At the same time, hardware accelerators such as graphics processing units continue to offer significant floating point performance gains for matrix and vector computations through easy-to-use libraries of computational kernels. However, as these libraries are usually composed of a well optimized but limited set of linear algebra operations, applications that use them often fail to reduce certain data communications, and hence fail to leverage the full potential of the accelerator. In this study, we target the acceleration of Krylov subspace iterative methods for graphics processing units, and in particular the Biconjugate Gradient Stabilized solver that significant improvement can be achieved by reformulating the method to reduce data-communications through application-specific kernels instead of using the generic BLAS kernels, e.g. as provided by NVIDIA’s cuBLAS library, and by designing a graphics processing unit specific sparse matrix-vector product kernel that is able to more efficiently use the graphics processing unit’s computing power. Furthermore, we derive a model estimating the performance improvement, and use experimental data to validate the expected runtime savings. Finally, considering that the derived implementation achieves significantly higher performance, we assert that similar optimizations addressing algorithm structure, as well as sparse matrix-vector, are crucial for the subsequent development of high-performance graphics processing units accelerated Krylov subspace iterative methods.

97 MATHEMATICS AND COMPUTING↗

SELF-CONSISTENT ORBITS AND PHYSICAL PROPERTIES FOR EIGHT SINGLE-LINED SPECTROSCOPIC BINARIES

For single-lined spectroscopic binaries (SB1s), self-consistent orbits can be determined via a simultaneous fit including both radial velocity data and the Hipparcos Intermediate Astrometric Data. Using the ratio λ of the semimajor axes of the photocenter to the primary orbits, the present paper develops an iterative fitting method. First, an initial orbit of an SB1 is determined with the assumption that λ equals 1. On the basis of this orbit, we use a stellar evolutionary model to distribute the total mass and luminosity to the primary and the secondary and update λ from the component mass and luminosity ratios. Then the orbit is updated using the updated value of λ, which completes a step of the iterative process. If this process is convergent, the resulting orbit is compatible with the physical properties of component stars. By using this method, the orbital solutions of eight SB1s as well as the physical properties are determined. We find that the component magnitude differences of these systems are very large, except for HIP 7143 and 45333. This suggests that only the secondaries of the two systems can be resolved with the present-day observational techniques, which is in agreement with recent observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Sparsity Prior Computed Tomography Reconstruction Using a Nonstandard Simultaneous X-ray Acquisition Model

In this article we systematically evaluate the performance of several state-of-the-art, sparsity prior computed tomography (CT) reconstruction algorithms, using a nonstandard simultaneous x-ray acquisition method. Sparsity prior is an efficient strategy in CT reconstruction, relying on iterative algorithms such as the algebraic reconstruction technique to produce a crude reconstruction, based on which sparse approximation is performed. The simultaneous x-ray acquisition model ensures rapid capture of x-rays; however, it captures a significantly fewer number of attenuation measurements, and the projections are nonuniform. We propose a weighted average filter in the reconstruction framework to ensure better quality reconstruction by minimizing the effect of nonuniform projections. The performance of the state-of-the-art algorithms is analyzed with and without weighted averaging before sparse approximation, in simulated and real environments. Experiments in the simulated environment are conducted with and without the presence of noise. From the results, it is evident that sparsity prior algorithms are capable of producing cross-sectional reconstruction using the simultaneous x-ray acquisition model, and better reconstruction quality is achievable with the incorporation of weighted averaging in the reconstruction framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GaAs micro-pyramids serving as optical micro-cavities

An efficient light-matter coupling requires high-quality (Q) micro-cavities with small mode volume. We suggest GaAs micro-pyramids placed on top of AlAs/GaAs distributed Bragg reflectors to be promising candidates. The pyramids were fabricated by molecular-beam epitaxy, electron-beam lithography and a subsequent wet-chemical etching process using a sacrificial AlAs layer. Measured Q-factors of optical modes in single pyramids reach values up to 650. A finite-difference time-domain simulation assuming a simplified cone-shaped geometry suggests possible Q-factors up to 3600. To enhance the light confinement in the micro-pyramids we intend to overgrow the pyramidal facets with a Bragg mirror--results of preliminary tests are given.

36 MATERIALS SCIENCE↗

Free (Reactionless) Torque Generation - Or Free Propulsion Concept

The basic principle in Newtonian Mechanics is based upon equal and opposite forces. Placing the vectors of velocity, acceleration, force and momentum of interacting objects along a single line satisfies the claim it is a linear or a 1-D concept. Classical Mechanics states that there are two main kinds of motion, linear and angular motion. Similarly placing the vectors of angular velocity, angular acceleration, torque and angular momentum along a line in the case of rotation in fact brings a plane 2-D interaction to the well known 1-D Newtonian concept. This adaptation transforms Classical Mechanics into a 1-D concept as well and presents a conformation that the linear concept is the only possible one. The Laws of Conservation of Momentum and Angular Momentum are results of the 1-D concept. But the world contains 3 geometrical spatial dimensions. Within the 3-D world there can exist 1-D, 2-D and 3-D kinds of interaction. The question is how to believe that the 3-D world can really be composed of a 1-D interaction or interactions made equal to the 1-D concept only? Examine a gyroscope - the only one mechanical device that is capable of performing 3-D behavior. The problem is that a gyroscope cannot perform three permanent and unidirectional torques that are fixed in space acting about perpendicular axes. This impossibility conforms to a 1-D concept. The idea is to find a solution that can be achieved for the 3-D concept.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical solution of the wave equation on 1+1 Minkowski space-time with scri-fixing conformal compatification

We solve numerically the wave equation on a fixed background space-time corresponding to 1+1 Minkowski space-time. In this case we use scri-fixing conformal compactifications and solve the wave equation on the conformal space-time. We draw space-time and conformal diagrams in order to describe the consistency of the results and the effects of the gauge choices. We are interested in containg g{sup +} in the numerical domain because such boundary is the future boundary of the wave function.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Reversibility of Newton-Raphson Root-Finding Method

Reversibility of a computational method is the ability to execute the method forward as well as backward. Reversible computational methods are generally useful in undoing incorrect computation in a speculative execution setting designed for efficient parallel processing. Here, reversibility is explored of a common component in scientific codes, namely, the Newton-Raphson root-finding method. A reverse method is proposed that is aimed at retracing the sequence of points that are visited by the forward method during forward iterations. When given the root, along with the number of iterations, of the forward method, this reverse method is aimed at backtracking along the reverse sequence of points to finally recover the original starting point of the forward method. The operation of this reverse method is illustrated on a few example functions, serving to highlight the method's strengths and shortcomings.

97 MATHEMATICS AND COMPUTING↗

CMFD and coarse-mesh DSA

The Coarse Mesh Finite Difference (CMFD) and Diffusion Synthetic Acceleration (DSA) methods are two widely-used, independently-developed acceleration methods for iteratively solving deterministic particle transport simulations. In this paper we show that these methods are related in the following way: if the standard notion of DSA as a 'fine mesh' method is generalized to that of a coarse mesh method, then the linearized form of CMFD is algebraically equivalent to a coarse mesh form of DSA. Also, we demonstrate theoretically (via Fourier analysis) and computationally that CMFD and coarse mesh DSA have nearly the same convergence properties. (authors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections

Purpose: To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. Methods: The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four {sup 103}Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selected from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. Results: For the phantom study, seed localization error is (0.58{+-}0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/iteration on a 1 GHz processor. Conclusions: The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate {approx}1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale modeling of the influence of Fe content in a Al-Si-Cu alloy on the size distribution of intermetallic phases and micropores

A multiscale model was developed to simulate the formation of Fe-rich intermetallics and pores in quaternary Al-Si-Cu-Fe alloys. At the microscale, the multicomponent diffusion equations were solved for multiphase (liquid-solid-gas) materials via a finite difference framework to predict microstructure formation. A fast and robust decentered plate algorithm was developed to simulate the strong anisotropy of the solid/liquid interfacial energy for the Fe-rich intermetallic phase. The growth of porosity was controlled by local pressure drop due to solidification and interactions with surrounding solid phases, in addition to hydrogen diffusion. The microscale model was implemented as a subroutine in a commercial finite element package, producing a coupled multiscale model. This allows the influence of varying casting conditions on the Fe-rich intermetallics, the pores, and their interactions to be predicted. Synchrotron x-ray tomography experiments were performed to validate the model by comparing the three-dimensional morphology and size distribution of Fe-rich intermetallics as a function of Fe content. Large platelike Fe-rich {beta} intermetallics were successfully simulated by the multiscale model and their influence on pore size distribution in shape castings was predicted as a function of casting conditions.

36 MATERIALS SCIENCE↗

Active space selection with self-healing diffusion Monte Carlo algorithms for periodic solids

Multideterminant Diffusion Monte Carlo (DMC) displays improved accuracy over single determinant DMC. Self-Healing Diffusion Monte Carlo (SHDMC) is a DMC based method that iteratively improves a multideterminant trial wavefunction. Although configuration interaction or complete active space (CAS) methods are very accurate and computationally feasible for many systems, they are not optimal for application to solids. SHDMC is accurate and designed for application to solids, so developing SHDMC based active space selection algorithms is a worthy endeavor. Here, we present and compare active space selection algorithms that are designed for use in conjunction with SHDMC, without relying on external approaches. For benchmarking, we calculated the ground state energy of a small unit cell of graphene and compared the results with a complete basis set extrapolated selected CI and a reference SHDMC trajectory. We found that systematically expanding the active space using an “auto-branching” algorithm optimally balances accuracy with computational practicality. To the best of our knowledge, this is the first work that demonstrates completely self-contained DMC-based active space selection algorithms that do not depend on external methods for determinant selection.

Spanedda, Nicole [ORNL]↗

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left–right (L-R), anterior–posterior (A-P), and superior–inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.Conclusions: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗