Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Probing Cellular Activity Via Charge‐Sensitive Quantum Nanoprobes

Nitrogen‐vacancy (NV) based quantum sensors hold great potential for real‐time single‐cell sensing with far‐reaching applications in fundamental biology and medical diagnostics. Although highly sensitive, the mapping of quantum measurements onto cellular physiological states has remained an exceptional challenge. Here, we introduce a novel quantum sensing modality capable of detecting changes in cellular activity. Our approach is based on the detection of environment‐induced charge depletion within an individual particle that, owing to a previously unaccounted transverse dipole term, induces systematic shifts in the zero‐field splitting (ZFS). Importantly, these charge‐induced shifts serve as a reliable indicator for lipopolysaccharide (LPS)‐mediated inflammatory response in macrophages. Furthermore, we demonstrate that surface modification of our diamond nanoprobes effectively suppresses these environment‐induced ZFS shifts, providing an important tool for differentiating electrostatic shifts caused by the environment from other unrelated effects, such as temperature variations. Notably, this surface modification also leads to significant reductions in particle‐induced toxicity and inflammation. Our findings shed light on systematic drifts and sensitivity limits of NV spectroscopy in a biological environment with ramifications for the critical discussion surrounding single‐cell thermogenesis. Notably, this work establishes the foundation for a novel sensing modality capable of probing complex cellular processes through straightforward physical measurements.

band bending↗

Luminosity determination in $pp$ collisions at $\sqrt{s}=13$ TeV using the ATLAS detector at the LHC

The luminosity determination for the ATLAS detector at the LHC during Run 2 is presented, with pp collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The absolute luminosity scale is determined using van der Meer beam separation scans during dedicated running periods in each year, and extrapolated to the physics data-taking regime using complementary measurements from several luminosity-sensitive detectors. The total uncertainties in the integrated luminosity for each individual year of data taking range from 0.9% to 1.1%, and are partially corre lated between years. After standard data-quality selections, the full Run 2 pp data sample corresponds to an integrated luminosity of 140.1 ± 1.2 fb -1 , i.e. an uncertainty of 0.83%. A dedicated sample of low-pileup data recorded in 2017– 2018 for precision Standard Model physics measurements is analysed separately, and has an integrated luminosity of 338.1 ± 3.1 pb -1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic analysis of fully constrained Cable-Driven Parallel Robots for automated prefabricated component installation

This paper presents a dynamic analysis and validation framework to assess a fully constrained six-anchor Cable-Driven Parallel Robot (CDPR) for automated installation of prefabricated facade components. Compared with conventional eight-anchor systems, the six-anchor configuration simplifies setup and reduces cost, but it also reduces control authority, shrinks the wrench-feasible workspace, and tightens orientation limits. Consequently, it is unclear a priori whether dynamically feasible trajectories exist to move the end effector from pickup to the facade. A constrained trajectory optimization is formulated to enforce the system dynamics, cable-tension bounds, and pose/velocity limits, and the framework is evaluated in simulation at three levels: (i) an idealized reference model, (ii) a lab-scale prototype model incorporating measured anchor misalignments and identified damping, and (iii) a full-scale three-story building model with load decomposition for structural feasibility checks. Across these scenarios, the analysis shows that optimal, constraint-satisfying trajectories exist that move the end effector from pickup to installation while maintaining a near-plumb, level orientation at the final pose. Collectively, this multi-scale dynamic analysis and validation framework supports the deployment readiness of the six-anchor CDPR and provides a prototype-based sensitivity case study of how measured anchor placement deviations affect feasibility.

CDPR↗

Retrieval of the sea spray aerosol mode from submicron particle size distributions and supermicron scattering during LASIC

Abstract. Improved quantification of sea spray aerosol concentration and size is important for determining aerosol effects on clouds and the climate, though attempts to accurately capture the size distribution of the sea spray mode remain limited by the availability of supermicron size distributions. In this work, we introduce a new approach to retrieving lognormal mode fit parameters for a sea spray aerosol mode by combining submicron size distributions with supermicron scattering measurements using a Mie inversion. Submicron size distributions were measured by an ultra-high-sensitivity aerosol spectrometer (UHSAS), and supermicron scattering was taken as the difference between <10 µm and <1 µm three-wavelength integrating nephelometer measurements (NEPH). This UHSAS-NEPH method was applied during background marine periods of the Department of Energy Atmospheric Radiation Measurement Layered Atlantic Smoke Interactions with Clouds (LASIC) campaign on Ascension Island (November 2016–May 2017), when the contribution of sea spray aerosol was expected to represent a large fraction of the aerosol mass and total scattering. Lognormal sea spray modal parameters were retrieved from comparisons between nephelometer measurements and a lookup table of Mie theory-simulated scattering coefficients for low-error solutions that minimized the 0.4–1 µm residual in the UHSAS size distribution. We evaluated the UHSAS-NEPH method with a set of clean marine measurements in the North Atlantic that included supermicron size and chemical measurements, showing that measured supermicron size distributions are needed to constrain the sea spray number concentration but that mass concentration was reasonably characterized using supermicron scattering. For LASIC, the UHSAS-NEPH method retrieved sea spray mode properties for approximately 88 % of the background marine times when the scattering variability and total particle concentration were low (<± 5 Mm−1 and <400 cm−3, respectively), with mass mean diameter ranging from 0.6 to 1.9 µm (1.47 ± 0.17 µm), modal width ranging from 1.1 to 3.97 (2.4±0.3), and mass concentration ranging from 0.18 to 23.0 µg m−3 (8.37. ± 4.1 µg m−3). The measured nephelometer scattering at three wavelengths was found to constrain the mode width marginally at the largest particle sizes in the absence of additional size and chemical measurements for defining parameters for the Mie solutions. Comparing UHSAS-NEPH retrievals to those of a fitting algorithm applied only to the submicron UHSAS number size distribution showed that correlations between retrieved mass concentration and the available mass-based sea spray tracers (coarse scattering, wind speed, and chloride) are low when supermicron measurements are not considered. This work demonstrates the added value of supermicron scattering measurements for retrieving reasonable sea spray mass concentrations, providing the best-available observationally constrained estimate of the sea spray mode properties when supermicron size distribution measurements are not available.

54 ENVIRONMENTAL SCIENCES↗

Substrate availability and not thermal acclimation controls microbial temperature sensitivity response to long-term warming

Microbes are responsible for cycling carbon (C) through soils, and predicted changes in soil C stocks under climate change are highly sensitive to shifts in the mechanisms assumed to control the microbial physiological response to warming. Two mechanisms have been suggested to explain the long-term warming impact on microbial physiology: microbial thermal acclimation and changes in the quantity and quality of substrates available for microbial metabolism. Yet studies disentangling these two mechanisms are lacking. To resolve the drivers of changes in microbial physiology in response to long-term warming, we sampled soils from 13- and 28-year-old soil warming experiments in different seasons. We performed short-term laboratory incubations across a range of temperatures to measure the relationships between temperature sensitivity of physiology (growth, respiration, carbon use efficiency, and extracellular enzyme activity) and the chemical composition of soil organic matter. We observed apparent thermal acclimation of microbial respiration, but only in summer, when warming had exacerbated the seasonally-induced, already small dissolved organic matter pools. Irrespective of warming, greater quantity and quality of soil carbon increased the extracellular enzymatic pool and its temperature sensitivity. We propose that fresh litter input into the system seasonally cancels apparent thermal acclimation of C-cycling processes to decadal warming. Our findings reveal that long-term warming has indirectly affected microbial physiology via reduced C availability in this system, implying that earth system models including these negative feedbacks may be best suited to describe long-term warming effects on these soils.

59 BASIC BIOLOGICAL SCIENCES↗

Event Selection at the DUNE Near Detector

The Deep Underground Neutrino Experiment (DUNE) is a next generation long-baseline experiment designed with a primary goal of providing definitive measurements of the neutrino mass ordering and the Charge Parity (CP)-violating phase. A key component in reaching these goals is the DUNE Near Detector (ND) complex, placed 574 m from the beam target, and tasked with characterising the neutrino beam and constraining systematic uncertainties before oscillation effects occur. We will present primary findings from the development of an event selection for $\nu_\mu$ CC interactions within the ND liquid argon time projection chamber (ND-LAr). These findings will include a discussion of the importance of defining metrics, such as efficiency and purity, such that we can meet the required sensitivity for DUNE's physics measurements.

Sabater Andres, Eva [Sussex U.] (ORCID:00090001748↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

Neutrino oscillations

Neutrino oscillation measurements provide an important window on what lies beyond the Standard Model of particle physics. These measurements may unlock the mechanism by which the universe came to become matter-dominated, and may offer hints of another mechanism to generate particles with mass. Measurements of oscillations from muon neutrinos to electron neutrinos (and their antineutrino counterpart) as a function of time provide critical inputs to understanding both mechanisms. These are challenging measurements and a variety of techniques and strategies are required to get the complete picture. This article describes the current status of our understanding of neutrino masses and how neutrinos oscillate between one flavour and another as they propagate through space and time, and what remains to be understood. Taking the next steps in this field requires a variety of approaches and a better understanding of how neutrinos interact with nuclei. This article describes two of those next steps, highlighting where Canadian groups are active, and concludes with a discussion of the broad range of additional physics that becomes accessible by having two very different large sensitive neutrino detectors making these measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of hardness on polymer-bonded pentaerythritol tetranitrate (PETN) explosive impact sensitivity

Handling sensitivity is an important property to assess when working with explosive samples and can be measured using a variety of tests, including drop-weight impact sensitivity. There exists a longstanding interest in the explosives community on the importance of measurable chemical, physical, and mechanical properties of explosives in impact sensitivity. However, most recent work in this area has explored chemical attributes rather than physical and mechanical properties of explosives. In this study, we measure hardness of explosive samples of pentaerythritol tetranitrate and Sylgard binder (XTX) during the curing process. The samples have been characterized for particle morphology through scanning electron microscopy and handling sensitivity through drop-weight impact testing. The relative importance of states of cure, methods of curing, morphology, and age of material are discussed. The data indicate that although there is a notable difference in morphology and mechanical properties for the samples as the polymer-bonded mixtures cure, the resulting changes to mechanical properties have a minimal effect on the sensitivity of the XTX.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MgADP Promotes Myosin Head Movement toward Actin at Low [Ca 2+ ] to Increase Force Production and Ca 2+ -Sensitivity of Contraction in Permeabilized Porcine Myocardial Strips

Myosin cross-bridges dissociate from actin following Mg 2+ -adenosine triphosphate (MgATP) binding. Myosin hydrolyses MgATP into inorganic phosphate (P i ) and Mg 2+ -adenosine diphosphate (ADP), and release of these hydrolysis products drives chemo-mechanical energy transitions within the cross-bridge cycle to power muscle contraction. Some forms of heart disease are associated with metabolic or enzymatic dysregulation of the MgATP-MgADP nucleotide pool, resulting in elevated cytosolic [MgADP] and impaired muscle relaxation. We investigated the mechanical and structural effects of increasing [MgADP] in permeabilized myocardial strips from porcine left ventricle samples. Sarcomere length was set to 2.0 µm at 28 °C, and all solutions contained 3% dextran T-500 to compress myofilament lattice spacing to near-physiological values. Under relaxing low [Ca 2+ ] conditions (pCa 8.0, where pCa = -log 10 [Ca 2+ ]), tension increased as [MgADP] increased from 0-5 mM. Complementary small-angle X-ray diffraction measurements show that the equatorial intensity ratio, I 1,1 /I 1,0 , also increased as [MgADP] increased from 0 to 5 mM, indicating myosin head movement away from the thick-filament backbone towards the thin-filament. Ca 2+ -activated force-pCa measurements show that Ca 2+ -sensitivity of contraction increased with 5 mM MgADP, compared to 0 mM MgADP. These data show that MgADP augments tension at low [Ca 2+ ] and Ca 2+ -sensitivity of contraction, suggesting that MgADP destabilizes the quasi-helically ordered myosin OFF state, thereby shifting the cross-bridge population towards the disordered myosin ON state. Together, these results indicate that MgADP enhances the probability of cross-bridge binding to actin due to enhancement of both thick and thin filament-based activation mechanisms.

60 APPLIED LIFE SCIENCES↗

Multi-Model and Multi-Scale Global Sensitivity Analysis for Identifying Controlling Processes of Complex Systems

An environmental model consists of multiple process level sub-models, and each sub-model represents a process that is key to the operation of the simulated system. Global sensitivity analysis methods have been widely used to identify important processes for system model development and improvement. The existing methods of global sensitivity analysis only consider parametric uncertainty, and are not capable of handling model uncertainty caused by multiple process models that arise from competing hypotheses about one or more processes. To address this problem, this project develops a new method to probe model output sensitivity to competing process models by integrating model averaging methods with variance-based global sensitivity analysis to address uncertainty in process models and parameters. The new method yields three process sensitivity indices. The first one is called first-order process sensitivity index, and it is derived as a single summary measure of relative process importance. Evaluating the index is computationally expensive, because it relies in a Monte Carlo scheme that requires thousands and even millions of model executions. To reduce computational cost, this project develops a computationally efficient, quasi Monte Carlo method, and this method is presented in Chapter 2 of this report with and a numerical example for demonstration. The numerical example shows that the results of the quasi Monte Carlo method are substantially close to those of the full Monte Carlo method, but the computational cost of the quasi Monte Carlo method is only 0.7% of that of the full Monte Carlo method. The second index is called total-effect process sensitivity index, and it measures interactions between different processes. Therefore, this sensitivity index includes the first-order process sensitivity index, and can be used to identify influential processes. On the other hand, the total-effect process sensitivity index can also be used to screen non-influential processes. This is demonstrated by two numerical examples using the Sobol-G* functions and groundwater flow models that consider recharge process, geological process, and snowmelt process. The numerical examples shows that the total-effect process sensitivity index is more informative than the first-order process sensitivity. The derivation of the process sensitivity index and the numerical examples are discussed in Chapter 3. Chapter 4 presents two computationally efficient methods for screening non-influential processes to exclude them from further investigation. The two methods are the multi-model difference-based sensitivity (MMDS) analysis method, which can be implemented using the Latin Hypercube Sampling. The second one is the implementation of MMDS method using a binning method. The numerical example for the Sobol-G* function indicates the two methods are capable of identifying non-influential models, and the numerical examples for the groundwater flow and reactive transport show that the two methods are effective for groundwater problems. However, it should be noted that the two methods are numerical approximations, and they can only be used for screening non-influential processes, not for ranking importance of system processes. All the sensitivity analysis methods are implemented by developing python codes, and the codes are in a software called SAMMPY: a python package for process sensitivity analysis under multiple models. The SAMMPY design and structure are discussed in Chapter 5, and the package is released to the public for free download.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity Studies, Gap Analysis, and Benchmark Experiment Optimization for Reactor Physics and Criticality Safety Applications

Many new reactor designs, such as advanced reactors and micro reactors, have materials that lack nuclear data validation. This is also true for many other applications in criticality safety and global security. Both differential and integral experiments are needed to validate cross-section data. Without this, a user cannot have confidence in the predicted results of a radiation-transport code. This work describes an approach called ARCHIMEDES (Application Relevant Critical/Subcritical HEU/Pu-based Integral Measurements for Enhancing Data and Evaluating Sensitivities) to design new criticality experiments that have similar k eff cross-section sensitivities to an application of interest. This process involves simulations to generate cross-section sensitivities to a parameter of interest (such as k eff ), a gap analysis to determine which existing benchmarks are most similar to the application, and an experiment optimization. Recently, there has been a great deal of interest in the reactor physics community on advanced reactors, micro reactors, and accelerator driven systems (ADS). This work will apply the described method to specific examples in this area. The focus of this work will be on the sensitivity study and gap analysis, while future work will include experiment design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The impact of optical measurement techniques on measured aerosol particle size distributions

Ambient aerosol particle size distributions measured by the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) at various sites around the world exhibit modes at optical diameters near 600 nm and 850 nm. These modes are not present in concurrent measurements with the Grimm 11-D Optical Particle Counter (OPC). Here, in this study, we argue that these modes result from the optical measurement technique itself, and we explain why they appear in measurements by the UHSAS but not in those by the Grimm OPC. We construct computer models of the UHSAS and Grimm (“digital UHSAS” and “digital Grimm”) and use these to investigate the size distribution that would result from measurements of artificial aerosol particle size distributions that do not contain modes. The appearance of modes for the structureless incoming size distributions sampled by the digital UHSAS is explained by the nonlinear behavior of partial scattering cross sections of uniform spherical particles as a function of their diameter. The absence of modes in the digital Grimm is explained by the coarser size resolution of that instrument. Detailed analysis of the relationship between optical and geometric diameters for uniform spherical particles reveals two important results. First, these diameters generally have different numerical values for the same particle, and second, the relationship is nonlinear; thus, widths of size bins in terms of optical diameter differ from those in geometric diameter. These results explain the modes observed in the ambient size distributions and highlight concerns with attempts to create a merged size distribution by combining measurements from different instruments.

54 ENVIRONMENTAL SCIENCES↗

Deriving cloud droplet number concentration from surface-based remote sensors with an emphasis on lidar measurements

Abstract. Given the importance of constraining cloud droplet number concentrations (Nd) in low-level clouds, we explore two methods for retrieving Nd from surface-based remote sensing that emphasize the information content in lidar measurements. Because Nd is the zeroth moment of the droplet size distribution (DSD), and all remote sensing approaches respond to DSD moments that are at least 2 orders of magnitude greater than the zeroth moment, deriving Nd from remote sensing measurements has significant uncertainty. At minimum, such algorithms require the extrapolation of information from two other measurements that respond to different moments of the DSD. Lidar, for instance, is sensitive to the second moment (cross-sectional area) of the DSD, while other measures from microwave sensors respond to higher-order moments. We develop methods using a simple lidar forward model that demonstrates that the depth to the maximum in lidar-attenuated backscatter (Rmax⁡) is strongly sensitive to Nd when some measure of the liquid water content vertical profile is given or assumed. Knowledge of Rmax⁡ to within 5 m can constrain Nd to within several tens of percent. However, operational lidar networks provide vertical resolutions of > 15 m, making a direct calculation of Nd from Rmax⁡ very uncertain. Therefore, we develop a Bayesian optimal estimation algorithm that brings additional information to the inversion such as lidar-derived extinction and radar reflectivity near the cloud top. This statistical approach provides reasonable characterizations of Nd and effective radius (re) to within approximately a factor of 2 and 30 %, respectively. By comparing surface-derived cloud properties with MODIS satellite and aircraft data collected during the MARCUS and CAPRICORN II campaigns, we demonstrate the utility of the methodology.

54 ENVIRONMENTAL SCIENCES↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays

This is the final technical report for the Virginia Tech Center for Photonics Technology (VT-CPT) research project entitled “Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays”. In the the four-year effort, VT-CPT collaborated with the Departments of Mathmatics at VT and Sentek Instrument, LLC (Sentek) to develop a fiber-optic sensing system capable of real-time simultaneous distributed measurement of multiple subsurface, drilling, and production parameters. The ultra-sensitive fiber optic distributed acoustic sensing technology, picoDAS, developed by Sentek was integrated with a novel multi-material optical sensing fiber fabricated by CPT-VT to obtain distributed acoustic and magnetic field measurements with ultrahigh sensitivity and high spatial resolution. The sensing technology successfully developed and demonstrated under this research program is truly unique has application beyond subsurface imaging to include carbon storage and electrical grid monitoring, as well as healthcare and nuclear fusion. The project, sponsored by the Advanced Technology Program, began in 2019 and had the original goal of developing the next generation of harsh environment sensing systems. Exhaustive theoretical modeling was performed to optimize the multi-material optical fiber design. VT developed the processing techniques employed to successfully fabricate single mode fibers with metal cladding wires. Sensing fibers with nickel and Metglas cladding wires were fully characterized, inscribed with sensors, and fully integrated with the picoDAS system. Laboratory scale testing was performed to demonstrate performance upon exposure to lateral and transverse magnetic fields. Preliminary field trials were performed for prototype magnetic and acoustic sensing systems upon near surface deployment at VT. The distributed acoustic and magnetic field sensing system was advanced from a (Technology Readiness Level) TRL=2 to a TRL=5 via laboratory scale system validation in relevant environments. The truly one-of-its kind distributed magnetic and acoustic sensing system is expected to find immediate applications that require subsurface monitoring, to include carbon storage site monitoring, and has the potential to be a distributive technology in healthcare and electric grid markets. The technologies developed by Virginia Tech’s Center for Photonics Technology will support the mission of the National Energy Technology Laboratory (NETL) to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future by ensuring affordable, abundant, and reliable energy that drives a robust economy and national security. Technical accomplishments during the program are summarized briefly here and described in detail in the remainder of the report.

02 PETROLEUM↗