Search NASA⌕ Search

SEARCH · Search NASA

Results for “missing values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Planck 2013 results. XXXI. Consistency of the Planck data

The Planck design and scanning strategy displays many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70 GHz (amplifier) and 100 GHz (bolometer) channels. Based on different instrument technologies, with feeds located differently in the focal plane, analysed independently by different teams using different software, and near the minimum of diffuse foreground emission, these channels are in effect two different experiments. The 143 GHz channel has the lowest noise level on Planck , and is near the minimum of unresolved foreground emission. In this paper, we analyse the level of consistency achieved in the 2013 Planck data. We concentrate on comparisons between the 70, 100, and 143 GHz channel maps and power spectra, particularly over the angular scales of the first and second acoustic peaks, on maps masked for diffuse Galactic emission and for strong unresolved sources. Difference maps covering angular scales from 8° to 15' are consistent with noise, and show no evidence of cosmic microwave background structure. Including small but important corrections for unresolved-source residuals, we demonstrate agreement (measured by deviation of the ratio from unity) between 70 and 100 GHz power spectra averaged over 70 ≤ ℓ ≤390 at the 0.8% level, and agreement between 143 and 100 GHz power spectra of 0.4% over the same ℓ range. These values are within and consistent with the overall uncertainties in calibration given in the Planck 2013 results. We also present results based on the 2013 likelihood analysis showing consistency at the 0.35% between the 100, 143, and 217 GHz power spectra. We analyse calibration procedures and beams to determine what fraction of these differences can be accounted for by known approximations or systematic errors that could be controlled even better in the future, reducing uncertainties still further. Several possible small improvements are described. Subsequent analysis of the beams quantifies the importance of asymmetry in the near sidelobes, which was not fully accounted for initially, affecting the 70/100 ratio. Correcting for this, the 70, 100, and 143 GHz power spectra agree to 0.4% over the first two acoustic peaks. The likelihood analysis that produced the 2013 cosmological parameters incorporated uncertainties larger than this. We show explicitly that correction of the missing near sidelobe power in the HFI channels would conclude in shifts in the posterior distributions of parameters of less than 0.3σ except for A s , the amplitude of the primordial curvature perturbations at 0.05 Mpc -1 , which changes by about 1σ. We extend these comparisons to include the sky maps from the complete nine-year mission of the Wilkinson Microwave Anisotropy Probe (WMAP), and find a roughly 2% difference between the Planck and WMAP power spectra in the region of the first acoustic peak.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the electroweak top quark production cross section and the CKM matrix element Vtb with the D0 experiment

At particle accelerators the Standard Model has been tested and will be tested further to a great precision. The data analyzed in this thesis have been collected at the world's highest energetic-collider, the Tevatron, located at the Fermi National Accelerator Laboratory (FNAL) in the vicinity of Chicago, IL, USA. There, protons and antiprotons are collided at a center-of-mass energy of {radical}s = 1.96 TeV. The discovery of the top quark was one of the remarkable results not only for the CDF and D0 experiments at the Tevatron collider, but also for the Standard Model, which had predicted the existence of the top quark because of symmetry arguments long before already. Still, the Tevatron is the only facility able to produce top quarks. The predominant production mechanism of top quarks is the production of a top-antitop quark pair via the strong force. However, the Standard Model also allows the production of single top quarks via the electroweak interaction. This process features the unique opportunity to measure the |V tb | matrix element of the Cabbibo-Kobayashi-Maskawa (CKM) matrix directly, without assuming unitarity of the matrix or assuming that the number of quark generations is three. Hence, the measurement of the cross section of electroweak top quark production is more than the technical challenge to extract a physics process that only occurs one out of ten billion collisions. It is also an important test of the V-A structure of the electroweak interaction and a potential window to physics beyond the Standard Model in the case where the measurement of |V{sub tb}| would result in a value significantly different from 1, the value predicted by the Standard Model. At the Tevatron two production processes contribute significantly to the production of single top quarks: the production via the t-channel, also called W-gluon fusion, and the production via the s-channel, known as well as W* process. This analysis searches for the combined s+t channel production cross section, assuming the ratio of s-channel production over t-channel production is realized in nature as predicted by the Standard Model. A data set of approximately 1 fb -1 is analyzed, the data set used by the D0 collaboration to claim evidence for single top quark production. Events with two, three, and four jets are used in the analysis if they contain one or two jets that were tagged as originating from the decay of a b hadron, an isolated muon or electron, and a significant amount of missing transverse energy. This selection of events follows the signature that the single top quark events are expected to show in the detector. In the meantime, both collaborations D0 and CDF have analyzed a larger data set and have celebrated the joint observation of single top quark production. The novelty of the analysis presented here is the way discriminating observables are determined. A so-called Multi-Process Factory evaluates each event under several hypotheses. A common analysis technique for example in top quark properties studies is to reconstruct the intermediate particles in the decay chain of the signal process from the final state objects measured in the various subdetectors. An essential part of such a method is to resolve the ambiguities that arise in the assignment of the final state objects to the partons of the decay chain. In a Multi-Process Factory this approach is extended and not only the decay chain of the signal process is reconstructed, but also the decay chains of the most important background processes. From the numerous possible event configurations for each of the signal and background decay chains the most probable configuration is selected based on a likelihood measure. Properties of this configuration, such as mass of the reconstructed top quark, are then used in a multivariate analysis technique to separate the expected signal contribution from the background processes. The technique which is used is called Boosted Decision Trees and has only recently been introduced in high energy physics analyses. A Bayesian approach is used to finally extract the cross section from the discriminant output of Boosted Decision Trees.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning

Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Ordering in Gold Nanoclusters

Here, several research groups have observed magnetism in monolayer-protected gold-cluster samples, but the results were often contradictory and thus a clear understanding of this phenomenon is still missing. We used Au 25 (SCH 2 CH 2 Ph) 18 0 , which is a paramagnetic cluster that can be prepared with atomic precision and whose structure is known precisely. Previous magnetometry studies only detected paramagnetism. We used samples representing a range of crystallographic orders and studied their magnetic behaviors by electron paramagnetic resonance (EPR). As a film, Au 25 (SCH 2 CH 2 Ph) 18 0 displays paramagnetic behavior but, at low temperature, ferromagnetic interactions are detectable. One or few single crystals undergo physical reorientation with the applied field and display ferromagnetism, as detected through hysteresis experiments. A large collection of microcrystals is magnetic even at room temperature and shows distinct paramagnetic, superparamagnetic, and ferromagnetic behaviors. Simulation of the EPR spectra shows that both spin-orbit coupling and crystal distortion are important to determine the observed magnetic behaviors. DFT calculations carried out on single cluster and periodic models predict values of spin6orbit coupling and crystal6splitting effects in agreement with the EPR derived quantities. Magnetism in gold nanoclusters is thus demonstrated to be the outcome of a very delicate balance of factors. To obtain reproducible results, the samples must be (i) controlled for composition and thus be monodispersed with atomic precision, (ii) of known charge state, and (iii) well defined also in terms of crystallinity and experimental conditions. This study highlights the efficacy of EPR spectroscopy to provide a molecular understanding of these phenomena

36 MATERIALS SCIENCE↗

Determination of Experimental Fuel Rod Parameters using 3D Modelling of PCMI with MPS Defect

An in-reactor experiment is being designed in order to validate the pellet-cladding mechanical interaction (PCMI) behavior of the BISON fuel performance code. The experimental parameters for the test rod being placed in the Halden Research Reactor are being determined using BISON simulations. The 3D model includes a missing pellet surface (MPS) defect to generate large local cladding deformations, which should be measureable after typical burnup times. The BISON fuel performance code is being developed at Idaho National Laboratory (INL) and is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. BISON supports both 2D and 3D finite elements and solves the fully coupled equations for solid mechanics, heat conduction and species diffusion. A number of fuel performance effects are included using models for swelling, densification, creep, relocation and fission gas production & release. In addition, the mechanical and thermal contact between the fuel and cladding is explicitly modelled using a master-slave based contact algorithm. In order to accurately predict PCMI effects, the BISON code includes the relevant physics involved and provides a scalable and robust solution procedure. The depth of the proposed MPS defect is being varied in the BISON model to establish an optimum value for the experiment. The experiment will be interrupted approximately every 6 months to measure cladding radial deformation and provide data to validate BISON. The complete rodlet (~20 discrete pellets) is being simulated using a 180° half symmetry 3D model with MPS defects at two axial locations. In addition, annular pellets will be used at the top and bottom of the pellet stack to allow thermocouples within the rod to measure the fuel centerline temperature. Simulation results will be presented to illustrate the expected PCMI behavior and support the chosen experimental design parameters.

BISON↗

Analysis of Experimental Fuel Rod Parameters using 3D Modelling of PCMI with MPS Defect

An in-reactor experiment is being designed in order to validate the pellet-cladding mechanical interaction (PCMI) behavior of the BISON fuel performance code. The experimental parameters for the test rod being placed in the Halden Research Reactor are being determined using BISON simulations. The 3D model includes a missing pellet surface (MPS) defect to generate large local cladding deformations, which should be measureable after typical burnup times. The BISON fuel performance code is being developed at Idaho National Laboratory (INL) and is built on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. BISON supports both 2D and 3D finite elements and solves the fully coupled equations for solid mechanics, heat conduction and species diffusion. A number of fuel performance effects are included using models for swelling, densification, creep, relocation and fission gas production & release. In addition, the mechanical and thermal contact between the fuel and cladding is explicitly modelled using a master-slave based contact algorithm. In order to accurately predict PCMI effects, the BISON code includes the relevant physics involved and provides a scalable and robust solution procedure. The depth of the proposed MPS defect is being varied in the BISON model to establish an optimum value for the experiment. The experiment will be interrupted approximately every 6 months to measure cladding radial deformation and provide data to validate BISON. The complete rodlet (~20 discrete pellets) is being simulated using a 180° half symmetry 3D model with MPS defects at two axial locations. In addition, annular pellets will be used at the top and bottom of the pellet stack to allow thermocouples within the rod to measure the fuel centerline temperature. Simulation results will be presented to illustrate the expected PCMI behavior and support the chosen experimental design parameters.

BISON↗

Measurement of the $\bar ν_μ-$Hydrogen Charged-Current Quasi-Elastic Cross Section using the NOvA Near Detector

We report a measurement of the total cross section for muon antineutrino charged-current quasi-elastic scattering on hydrogen, $\bar ν_μ{\rm H} \to μ^+ n$, in the NOvA near detector using a $1.2\times10^{21}$ proton-on-target exposure in the NuMI beam. A selection based on topological and kinematic constraints yields 35,509 signal events in the hydrogen-rich ($10.8\%$) detector, providing the highest statistics of (anti)neutrino--hydrogen interactions measured to date. Backgrounds from (anti)neutrino interactions on heavier nuclei are constrained using dedicated data control samples, significantly reducing the related systematic uncertainties. We obtain a value $σ(\bar ν_μ{\rm H} \to μ^+ n) = 0.538 \pm 0.009 ({\rm stat}) \pm 0.010 ({\rm syst}) \pm0.055 ({\rm flux}) \times 10^{-38}$ cm$^2$ for the total cross section at an average energy of 1.9 GeV, the most precise total cross-section measurement of this process to date. The combined statistical and non-flux systematic uncertainty is more than four times smaller than the flux uncertainty, allowing a future use of this measurement to constrain the absolute $\bar ν_μ$ flux.

Abubakar, S. [Erciyes U.]↗

Measurement of the $\bar ν_μ-$Hydrogen Charged-Current Quasi-Elastic Cross Section using the NOvA Near Detector

We report a measurement of the total cross section for muon antineutrino charged-current quasi-elastic scattering on hydrogen, $\bar ν_μ{\rm H} \to μ^+ n$, in the NOvA near detector using a $1.2\times10^{21}$ proton-on-target exposure in the NuMI beam. A selection based on topological and kinematic constraints yields 35,509 signal events in the hydrogen-rich ($10.8\%$) detector, providing the highest statistics of (anti)neutrino--hydrogen interactions measured to date. Backgrounds from (anti)neutrino interactions on heavier nuclei are constrained using dedicated data control samples, significantly reducing the related systematic uncertainties. We obtain a value $σ(\bar ν_μ{\rm H} \to μ^+ n) = 0.538 \pm 0.009 ({\rm stat}) \pm 0.010 ({\rm syst}) \pm0.055 ({\rm flux}) \times 10^{-38}$ cm$^2$ for the total cross section at an average energy of 1.9 GeV, the most precise total cross-section measurement of this process to date. The combined statistical and non-flux systematic uncertainty is more than four times smaller than the flux uncertainty, allowing a future use of this measurement to constrain the absolute $\bar ν_μ$ flux.

Abubakar, S. [Erciyes U.]↗

The Role of Pentaerythritol Tetranitrate (PETN) Aging in Determining Detonator Firing Characteristics

Pentaerythritol tetranitrate (PETN) is one of the most commonly used explosives for both military and mining applications. PETN is used in EBW (exploding bridge wire) and EFI (exploding foil initiator) detonator devices. Due the widespread usage of PETN, studies focusing on how the explosive changes with age, primarily its function in detonators has received particular interest. Aging studies have identified several factors that affect PETN detonator function over time, most notably the specific surface area of the explosive powder. Though small-scale studies have been performed on specific detonator systems with isolated batches of material, what is missing is a large statistically-significant study focusing on PETN aging characteristics - such as powder coarsening - and their influence on detonator performance. Herein we report the first large statistically viable PETN aging study focusing on four batches of PETN powder from the same stock of PETN using two stabilizers, polysaccharide and TriPEON. PETN was aged both as a free-flowing powder as well as in modified EBW RP-2 detonators, for one month at 75 °C. The PETN powder has been analyzed chemically using Fisher specific surface area analysis, SEM imaging and light scattering particle size analysis. Additionally the detonators were tested for performance through voltage-sweep threshold testing and function time measurements. Findings from the study indicate that aging at 75 °C for one month significantly changes the specific surface area and particle size of unstabilized PETN, leading to increases in detonator function time, but not detonator threshold values. Powders stabilized with TriPEON displayed less significant increases in function time, while powder stabilized with polysaccharide exhibited no aging effects, despite the high temperature aging.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

[Fe II] 1.64 μm FEATURES OF JETS AND OUTFLOWS FROM YOUNG STELLAR OBJECTS IN THE CARINA NEBULA

We present [Fe II] 1.64 μm imaging observations for jets and outflows from young stellar objects (YSOs) over the northern part (∼24' × 45') of the Carina Nebula, a massive star-forming region. The observations were performed with IRIS2 of the Anglo-Australian Telescope and the seeing was ∼1.''5 ± 0.''5. Eleven jet and outflow features are detected at eight different regions and are termed ionized Fe objects (IFOs). One Herbig-Haro candidate that was missed in Hubble Space Telescope Hα observations is newly identified as HHc-16, referring to our [Fe II] images. IFOs have knotty or longish shapes, and the detection rate of IFOs against previously identified YSOs is 1.4%, which should be treated as a lower limit. Four IFOs show anti-correlated peak intensities in [Fe II] and Hα, where the ratio I([Fe II])/I(Hα) is higher for longish IFOs than for knotty IFOs. We estimate the outflow mass loss rate from the [Fe II] flux using two different methods. The jet-driving objects are identified for three IFOs (IFO-2, -4, and -7) for which we study the relations between the outflow mass loss rate and the YSO physical parameters from the radiative transfer model fitting. The ratios of the outflow mass loss rate over the disk accretion rate for IFO-4 and -7 are consistent with the previously reported values (10{sup –2}-10{sup +1}), while the ratio is higher for IFO-2. This excess may result from underestimating the disk accretion rate. The jet-driving objects are likely to be low- or intermediate-mass stars. Other YSO physical parameters, such as luminosity and age, show reasonable relations or trends.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian Characterization of Main-sequence Binaries in the Old Open Cluster NGC 188

The binary fractions of open and globular clusters yield powerful constraints on their dynamical state and evolutionary history. We apply publicly available Bayesian analysis tools to a UBV RIJHK {sub S} photometric catalog of the open cluster NGC 188 to detect and characterize photometric binaries along the cluster main sequence. This technique has the advantage of self-consistently handling photometric errors, missing data in various bandpasses, and star-by-star prior constraints on cluster membership. Simulations are used to verify uncertainties and quantify selection biases in our analysis, illustrating that among binaries with mass ratios >0.5, we recover the binary fraction to better than 7% in the mean, with no significant dependence on binary fraction and a mild dependence on assumed mass-ratio distribution. Using our photometric catalog, we recover the majority (65% ± 11%) of spectroscopically identified main-sequence binaries, including eight of the nine with spectroscopically measured mass ratios. Accounting for incompleteness and systematics, we derive a mass-ratio distribution that rises toward lower mass ratios (within our q > 0.5 analysis domain). We observe a raw binary fraction for solar-type main-sequence stars with mass ratios q > 0.5 of 42% ± 4%, independent of the assumed mass-ratio distribution to within its uncertainties, consistent with literature values for old open clusters but significantly higher than the field solar-type binary fraction. We confirm that the binaries identified by our method are more concentrated than single stars, in agreement with previous studies, and we demonstrate that the binary nature of those candidates that remain unidentified spectroscopically is strongly supported by photometry from Gaia DR2.

79 ASTRONOMY AND ASTROPHYSICS↗

Enantioselective ecotoxicity of promethazine in two freshwater organisms: daphnia (Daphnia magna) and zebrafish ( Danio rerio )

Abstract Chiral pharmaceuticals, racemic or enantiomerically pure forms and their metabolites, can reach aquatic ecosystems via wastewater effluents (inefficient treatment operations) or by direct human disposal. They may negatively affect nontarget organisms even at low environmental concentrations. To make an accurate risk evaluation, the (eco)toxicity of both enantiomers needs to be assessed. Promethazine (PMZ) is a chiral antihistamine that has been detected in aquatic ecosystems owing to its high consumption. Promethazine undergoes metabolism in the liver, producing chiral metabolites such as promethazine sulfoxide (PMZSO) and N-desmethylpromethazine (DMPMZ) that reach water bodies. However, knowledge regarding the enantioselective toxicity of PMZ and its metabolites on aquatic organisms is missing. This study aimed to explore the potential enantioselective toxicity of PMZ and its metabolites on two relevant freshwater organisms, daphniid and fish, representing different trophic levels. The half maximal effect concentrations (EC50s) in Daphnia magna of PMZ, DMPMZ, and PMZSO were 2.33, 2.31, > 4 mg L−1, respectively, > 4 and 2.50 mg L−1 for (R) and (S)-PMZ, respectively, and > 4 mg L−1 for the enantiomers of DMPMZ and PMZSO. In studies involving zebrafish, Danio rerio, (R, S)-PMZ showed a median lethal concentration (LC50) of .72 mg L−1, and specific assays revealed that (R)-PMZ exhibited more pronounced adverse effects on larvae at the embryonic, morphological, and biochemical level than the racemate and (S)-PMZ. Toxicity and potential bioaccumulation of these compounds in daphniids and fish were also conducted using in silico tests through proprietary software. The results revealed a concordance between the experimental and predicted EC50 and LC50 values in both species.

Coelho, Maria Miguel↗

A Non-Exhaustive Search Algorithm to Identify Distribution Grid Operational Topology

Distribution grid, in general, is constructionally loopy but a radially operated network. Opening and closing of suitable tie-switches allow transition from one topology to another. Identifying the operational topology of a distribution system is essential for accurate control actions. This paper proposes a non-exhaustive search approach to detect the operational topology of the distribution feeder by estimating the switch statuses. In this work, a mixed-integer linear programming approach is proposed that finds the correct operational topology by identifying the system load demand and power flow variables that are closest to the corresponding measured values. The problem is constrained by distribution power flow and radial structure of the feeder. This formulation allows the inclusion of errors in power/line flow measurements making it more suitable for a practical distribution system. The proposed approach finds the correct operational topology without exhaustively searching for all possible topologies. We thoroughly validate the accuracy and effectiveness of the proposed approach in identifying correct operational topology using IEEE 123-node feeder with the help of numerous simulations studies. It is observed that the approach performs well even at very high percentages of load and flow measurement errors.

Missed detection ratio (MDR), Mixed-integer linear↗

Analysis of seismicity at observed at station BCE using subspace detectors

A dynamic correlation processor (DCP) was used to process 90 days of 3-component seismic data recorded by station BCE. Two methods of detector creation were compared. The first attempted to span the signal space with a small number of subspace detectors having minimal projections on one another, and the second used a much larger number of detectors with substantial inter-template projections. After two passes over the data the results were compared, and the second approach was found to have produced more than 3 times the number of detections. For events in common, the average correlation statistic for the second approach was 0.77 compared to a statistic of 0.65 for the first approach. Also, analysis of the detection statistics as a function of SNR showed a strong functional relationship between SNR and correlation statistic for the second approach not found in the first approach. I interpret this to mean that the intra-group variability of signals produced by the second method is due primarily to noise rather than variations in source or path. These results show that (in an environment with large numbers of repeaters) if precise classification is a goal, it is better to operate a DCP with many correlators with substantial inter-template projections and that fully span the signal space. The performance of the DCP was also measured using a small set of “ground truth” picks for BCE from the Chip Brogan catalog. The catalog spanned less than three days out of the 90 days of the experiment and is also incomplete, but the comparison identified 12 signals missed by the DCP because of low SNR. Combining detections by the DCP and picks from the Brogan catalog, identifies 76 unique signals. Of these, the DCP detected 64 (84%) and the Catalog contained between 48/76 (63%) and 48/62 (77%). Analysis of time-of-day and day-of-week statistics was not useful in identifying the signal sources. However, magnitude recurrence statistics were consistent with mining induced seismicity (a preponderance of small sources). Failure of the temporal discriminants may indicate that the events being detected are not coupled in the same way to the mining activity, e.g. secondary failures. Correlation data from explosions at the Nevada test site (NTS) were used to bound the separation of events within groups. Nearly all the NTS correlations with the same passband and time bandwidth product as the detections and having a correlation statistic >= 0.8 are from sources separated by less than 1 km. Even at correlation values of 0.6 nearly all the source separations are less than about 3 km. Because the DCP detectors were formed to span the signal space at a correlation value of 0.9 and because the intra-group variability is most likely due to noise and not source variability, it is likely that the sources associated with each detector are separated by one km or less, and almost certain that the majority are separated by no more than 3 km.

47 OTHER INSTRUMENTATION↗

Complexity and near extremal charged black branes

Highlights: • Trying to explore a remedy to overcome the puzzle in holographic complexity by assuming a cutoff behind the horizon and the corresponding boundary term. • Holographic complexity growth obtained by the WDW patch on shell action is insensitive to the UV cutoff at the late time. Therefore one may conclude that either on shell action does not compute complexity, or the late time is not given by the physical charges, or in our computations we have missed something! • We find that one needs to carefully compute on shell action taking into account the behind the horizon and the corresponding boundary term. Doing so, one arrives at a consistent picture. • We check this consistency by evaluating the late time complexity growth for near horizon limit of the near extremal black hole using two different methods. We would have obtained non-consistent picture, if we had not considered the behind the horizon cutoff as well as the corresponding boundary term. We compute holographic complexity of charged black brane solutions in arbitrary dimensions for the near horizon limit of near extremal case using two different methods. The corresponding complexity may be obtained either by taking the limit from the complexity of the charged black brane, or by computing the complexity for near horizon limit of near extremal solution. One observes that these results coincide if one assumes to have a cutoff behind horizon whose value is fixed by UV cutoff and also taking into account a proper counterterm evaluated on this cutoff. We also consider the situation for Vaidya charged black branes too.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for vectorlike B quarks in events with one isolated lepton, missing transverse momentum, and jets at √s = 8 TeV with the ATLAS detector

A search has been performed for pair production of heavy vectorlike down-type (B) quarks. The analysis explores the lepton-plus-jets final state, characterized by events with one isolated charged lepton (electron or muon), significant missing transverse momentum, and multiple jets. One or more jets are required to be tagged as arising from b quarks, and at least one pair of jets must be tagged as arising from the hadronic decay of an electroweak boson. The analysis uses the full data sample of pp collisions recorded in 2012 by the ATLAS detector at the LHC, operating at a center-of-mass energy of 8 TeV, corresponding to an integrated luminosity of 20.3 fb⁻¹. No significant excess of events is observed above the expected background. Limits are set on vectorlike B production, as a function of the B branching ratios, assuming the allowable decay modes are B → Wt/Zb/Hb . In the chiral limit with a branching ratio of 100% for the decay B → Wt , the observed (expected) 95% C.L. lower limit on the vectorlike B mass is 810 GeV (760 GeV). In the case where the vectorlike B quark has branching ratio values corresponding to those of an SU (2) singlet state, the observed (expected) 95% C.L. lower limit on the vectorlike B mass is 640 GeV (505 GeV). The same analysis, when used to investigate pair production of a colored, charge 5/3 exotic fermion T 5/3 , with subsequent decay T 5/ 3 → Wt , sets an observed (expected) 95% C.L. lower limit on the T 5/3 mass of 840 GeV (780 GeV).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the Dark Photon and the Dark Higgs Boson at Belle

The dark photon A ' and the dark Higgs boson h ' are hypothetical constituents featured in a number of recently proposed dark sector models. Assuming prompt decays of both dark particles, we search for their production in the so-called Higgstrahlung channel e + e - → A ' h ' , with h ' → A ' A ' . We investigate ten exclusive final states with A ' → e + e - , μ + μ - , or π + π - in the mass ranges 0.1 GeV / c 2 < m A ' < 3.5 GeV / c 2 and 0.2 GeV / c 2 < m h ' < 10.5 GeV / c 2 . We also investigate three inclusive final states 2 ( e + e - ) X , 2 ( μ + μ - ) X , and ( e + e - ) ( μ + μ - ) X , where X denotes a dark photon candidate detected via missing mass, in the mass ranges 1.1 GeV / c 2 < m A ' < 3.5 GeV / c 2 and 2.2 GeV / c 2 < m h ' < 10.5 GeV / c 2 . Using the entire 977 fb - 1 data set collected by Belle, we determine no significant signal. Here, we obtain individual and combined 90% credibility level upper limits on the branching fraction times the Born cross section, B × σ Born , on the Born cross section σ Born , and on the dark photon coupling to the dark Higgs boson times the kinetic mixing between the standard model photon and the dark photon, α D × ε 2 . These limits improve upon and cover wider mass ranges than previous experiments. The limits from the final states 3 ( π + π - ) and 2 ( e + e - ) X are the first placed by any experiment. For α D equal to 1 / 137 , m h ' < 8 GeV / c 2 , and m A ' < 1 GeV / c 2 , we exclude values of the mixing parameter ε above ~ 8×10 -4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗