Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Acoustic results of supersonic tip speed fan blade modification

A supersonic tip speed single stage fan was modified with the intent of reducing multiple pure tone (MPT) or buzz saw noise. There were three modifications to the blades from the original design. The modifications to the blade resulted in an increase in cascade throat area causing the shock to start at a lower corrected fan speed. The acoustic results without acoustically absorbing liners showed substantial reduction in multiple pure tone levels. However, an increase in the blade passing frequency noise at takeoff fan speed accompanied the MPT reduction. The net result however, was a reduction in the maximum 1000-foot (304.8 m) altitude level flyover PNL. For the case with acoustic treatment in the inlet outer wall, the takeoff noise increased relative to an acoustically treated baseline. This was largely due to the increased blade passing frequency noise which was not effectively reduced by the liner.

Jutras, R. R.↗

Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels. A test box containing plywood (specific gravity 0.5) with holes for reproducible positioning of known point sources has been constructed and used in several configurations. Gamma spectra have been processed multiple times with user-adjustable parameters set to a variety of values to gain agreement on the most appropriate settings. A similar optimization process was followed with the custom software provided by the instrument manufacturer to reach agreement on the most stable settings for reliable results. Measurements made with the Canberra In-Situ Object Counting System (ISOCS) instrument were compared with the WAS results as part of an estimate of instrument precision and accuracy. The validation report will conclude with recommendations for the configuration, appropriate use and limitations of the Waste Assay System. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiple system modelling of waste management

Highlights: > Linking of models will provide a more complete, correct and credible picture of the systems. > The linking procedure is easy to perform and also leads to activation of project partners. > The simulation procedure is a bit more complicated and calls for the ability to run both models. - Abstract: Due to increased environmental awareness, planning and performance of waste management has become more and more complex. Therefore waste management has early been subject to different types of modelling. Another field with long experience of modelling and systems perspective is energy systems. The two modelling traditions have developed side by side, but so far there are very few attempts to combine them. Waste management systems can be linked together with energy systems through incineration plants. The models for waste management can be modelled on a quite detailed level whereas surrounding systems are modelled in a more simplistic way. This is a problem, as previous studies have shown that assumptions on the surrounding system often tend to be important for the conclusions. In this paper it is shown how two models, one for the district heating system (MARTES) and another one for the waste management system (ORWARE), can be linked together. The strengths and weaknesses with model linking are discussed when compared to simplistic assumptions on effects in the energy and waste management systems. It is concluded that the linking of models will provide a more complete, correct and credible picture of the consequences of different simultaneous changes in the systems. The linking procedure is easy to perform and also leads to activation of project partners. However, the simulation procedure is a bit more complicated and calls for the ability to run both models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Filter-based Absorption Measurements of Biomass Burning Aerosol and Background Aerosol at the Mt. Bachelor Observatory

In this study we evaluate the recently upgraded aethalometer (AE33) and the newly released tricolor absorption photometer (TAP) with respect to their response to wildfire aerosol plumes during their deployment at the Mount Bachelor Observatory (MBO; 2763 m a.s.l.) in central Oregon, USA, during the summer of 2016. While both instruments use similar methodology (i.e., light extinction through an aerosol-laden filter), each has a unique set of correction schemes to address artifacts originating from filter loading, scattering from captured aerosol particles, and multiple scattering effects of the filter fibers. We also utilize a Single Particle Soot Photometer (SP2) to determine refractory black carbon (rBC) in these air masses. In addition to comparing the AE33 filter-loading correction methodology to previously published aethalometer correction schemes, we also compare the AE33 to the correction schemes used for the TAP and evaluate the degree to which the different correction factors influence the derived absorption Ångström exponents (AAE) and mass absorption cross sections (MACs). We find that while the different correction factors for either the AE33 or TAP do exert an influence on the derived MACs, AAEs exhibit the most sensitivity to the correction schemes. Our study finds that using the AE33 manufacturer’s recommended settings results in aerosol light absorption coefficients that are 3.4 to 4 times greater than the aerosol light absorption coefficients reported by the TAP. We calculated a correction factor (Cf) of 4.35 for the AE33 by normalizing the AE33 to match the TAP. The uncorrected AE33 also gives equivalent black carbon (eBC) values that are approximately 2 times the rBC measured by the SP2 instrument. We also find that biomass burning aerosols result in significant MAC enhancements, particularly at lower wavelengths, which is attributable to brown carbon (BrC).

54 ENVIRONMENTAL SCIENCES↗

Simple, Fast and Effective Correction for Irradiance Spatial Nonuniformity in Measurement of IVs of Large Area Cells at NREL

The NREL cell measurement lab measures the IV parameters of cells of multiple sizes and configurations. A large contributing factor to errors and uncertainty in Jsc, Imax, Pmax and efficiency can be the irradiance spatial nonuniformity. Correcting for this nonuniformity through its precise and frequent measurement can be very time consuming. This paper explains a simple, fast and effective method based on bicubic interpolation for determining and correcting for spatial nonuniformity and verification of the method's efficacy.

14 SOLAR ENERGY↗

Miniature optical planar camera based on a wide-angle metasurface doublet corrected for monochromatic aberrations

Optical metasurfaces are two-dimensional arrays of nano-scatterers that modify optical wavefronts at subwavelength spatial resolution. They are poised to revolutionize optics by enabling complex low-cost systems where multiple metasurfaces are lithographically stacked and integrated with electronics. For imaging applications, metasurface stacks can perform sophisticated image corrections and can be directly integrated with image sensors. Here we demonstrate this concept with a miniature flat camera integrating a monolithic metasurface lens doublet corrected for monochromatic aberrations, and an image sensor. The doublet lens, which acts as a fisheye photographic objective, has a small f-number of 0.9, an angle-of-view larger than 60° × 60°, and operates at 850 nm wavelength with 70% focusing efficiency. The camera exhibits nearly diffraction-limited image quality, which indicates the potential of this technology in the development of optical systems for microscopy, photography, and computer vision.

47 OTHER INSTRUMENTATION↗

Anharmonic Rovibrational Partition Functions for Fluxional Species at High Temperatures via Monte Carlo Phase Space Integrals

Monte Carlo phase space integration (MCPSI) is used to compute full dimensional and fully anharmonic, but classical, rovibrational partition functions for 22 small- and medium-sized molecules and radicals. Several of the species considered here feature multiple minima and low-frequency nonlocal motions, and efficiently sampling these systems is facilitated using curvilinear (stretch, bend, and torsion) coordinates. The curvilinear coordinate MCPSI method is demonstrated to be applicable to the treatment of fluxional species with complex rovibrational structures and as many as 21 fully coupled rovibrational degrees of freedom. Trends in the computed anharmonicity corrections are discussed. For many systems, rovibrational anharmonicities at elevated temperatures are shown to vary consistently with the number of degrees of freedom and with temperature once rovibrational coupling and torsional anharmonicity are accounted for. In conclusion, larger corrections are found for systems with complex vibrational structures, such as systems with multiple large-amplitude modes and/or multiple minima.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplicity and net-electric charge fluctuations in central Ar+Sc interactions at 13 A , 19 A , 30 A , 40 A , 75 A , and 150 A GeV/c beam momenta measured by NA61/SHINE at the CERN SPS

This paper presents results on multiplicity fluctuations of positively and negatively charged hadrons as well as net-electric charge fluctuations measured in central Ar+Sc interactions at beam momenta 13 A , 19 A , 30 A , 40 A , 75 A , and 150 A GeV/c. The fluctuation analysis is one of the tools to search for the predicted critical point of strongly interacting matter. Results are corrected for the experimental biases and quantified using cumulant ratios. In most instances, multiplicity and net-charge distributions appear narrower than the corresponding Poisson or Skellam distributions. Cumulant ratios are compared with the EPOS1.99 model predictions, which provide a qualitative description that aligns with observations for positively and negatively charged particles. The obtained results are also compared to earlier NA61/SHINE results from inelastic p+p interactions in the same analysis acceptance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular control of brain size: Regulators of neural stem cell life, death and beyond

The proper development of the brain and other organs depends on multiple parameters, including strictly controlled expansion of specific progenitor pools. The regulation of such expansion events includes enzymatic activities that govern the correct number of specific cells to be generated via an orchestrated control of cell proliferation, cell cycle exit, differentiation, cell death etc. Certain proteins in turn exert direct control of these enzymatic activities and thus progenitor pool expansion and organ size. The members of the Cip/Kip family (p21Cip1/p27Kip1/p57Kip2) are well-known regulators of cell cycle exit that interact with and inhibit the activity of cyclin-CDK complexes, whereas members of the p53/p63/p73 family are traditionally associated with regulation of cell death. It has however become clear that the roles for these proteins are not as clear-cut as initially thought. In this review, we discuss the roles for proteins of the Cip/Kip and p53/p63/p73 families in the regulation of cell cycle control, differentiation, and death of neural stem cells. We suggest that these proteins act as molecular interfaces, or 'pilots', to assure the correct assembly of protein complexes with enzymatic activities at the right place at the right time, thereby regulating essential decisions in multiple cellular events.

60 APPLIED LIFE SCIENCES↗

Evaluation of a Pair-Wise Conflict Detection and Resolution Algorithm in a Multiple Aircraft Scenario

The KB3D algorithm is a pairwise conflict detection and resolution (CD&R) algorithm. It detects and generates trajectory vectoring for an aircraft which has been predicted to be in an airspace minima violation within a given look-ahead time. It has been proven, using mechanized theorem proving techniques, that for a pair of aircraft, KB3D produces at least one vectoring solution and that all solutions produced are correct. Although solutions produced by the algorithm are mathematically correct, they might not be physically executable by an aircraft or might not solve multiple aircraft conflicts. This paper describes a simple solution selection method which assesses all solutions generated by KB3D and determines the solution to be executed. The solution selection method and KB3D are evaluated using a simulation in which N aircraft fly in a free-flight environment and each aircraft in the simulation uses KB3D to maintain separation. Specifically, the solution selection method filters KB3D solutions which are procedurally undesirable or physically not executable and uses a predetermined criteria for selection.

Carreno, Victor A.↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Measurement of the inclusive and differential Higgs boson production cross sections in the leptonic WW decay mode at $\sqrt{s} =$ 13 TeV

Measurements of the fiducial inclusive and differential production cross sections of the Higgs boson in proton-proton collisions at $ \sqrt{s} $ = 13 TeV are performed using events where the Higgs boson decays into a pair of W bosons that subsequently decay into a final state with an electron, a muon, and a pair of neutrinos. The analysis is based on data collected with the CMS detector at the LHC during 2016–2018, corresponding to an integrated luminosity of 137 fb$^{−1}$. Production cross sections are measured as a function of the transverse momentum of the Higgs boson and the associated jet multiplicity. The Higgs boson signal is extracted and simultaneously unfolded to correct for selection efficiency and resolution effects using maximum-likelihood fits to the observed distributions in data. The integrated fiducial cross section is measured to be 86.5 ± 9.5 fb, consistent with the Standard Model expectation of 82.5 ± 4.2 fb. No significant deviation from the Standard Model expectations is observed in the differential measurements.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of multijet event isotropies using optimal transport with the ATLAS detector

A measurement of novel event shapes quantifying the isotropy of collider events is performed in 140 fb -1 of proton-proton collisions with $\sqrt{s}$ = 13 TeV centre-of-mass energy recorded with the ATLAS detector at CERN’s Large Hadron Collider. These event shapes are defined as the Wasserstein distance between collider events and isotropic reference geometries. This distance is evaluated by solving optimal transport problems, using the ‘Energy-Mover’s Distance’. Isotropic references with cylindrical and circular symmetries are studied, to probe the symmetries of interest at hadron colliders. The novel event-shape observables defined in this way are infrared- and collinear-safe, have improved dynamic range and have greater sensitivity to isotropic radiation patterns than other event shapes. The measured event-shape variables are corrected for detector effects, and presented in inclusive bins of jet multiplicity and the scalar sum of the two leading jets’ transverse momenta. The measured distributions are provided as inputs to future Monte Carlo tuning campaigns and other studies probing fundamental properties of QCD and the production of hadronic final states up to the TeV-scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cigarettes vs. e-cigarettes: Passive exposure at home measured by means of airborne marker and biomarkers

Background: There is scarce evidence about passive exposure to the vapour released or exhaled from electronic cigarettes (e-cigarettes) under real conditions. The aim of this study is to characterise passive exposure to nicotine from e-cigarettes' vapour and conventional cigarettes' smoke at home among non-smokers under real-use conditions. Methods: We conducted an observational study with 54 non-smoker volunteers from different homes: 25 living at home with conventional smokers, 5 living with nicotine e-cigarette users, and 24 from control homes (not using conventional cigarettes neither e-cigarettes). We measured airborne nicotine at home and biomarkers (cotinine in saliva and urine). We calculated geometric mean (GM) and geometric standard deviations (GSD). We also performed ANOVA and Student's t tests for the log-transformed data. We used Bonferroni-corrected t-tests to control the family error rate for multiple comparisons at 5%. Results: The GMs of airborne nicotine were 0.74 μg/m{sup 3} (GSD=4.05) in the smokers’ homes, 0.13 μg/m{sup 3} (GSD=2.4) in the e-cigarettes users’ homes, and 0.02 μg/m{sup 3} (GSD=3.51) in the control homes. The GMs of salivary cotinine were 0.38 ng/ml (GSD=2.34) in the smokers’ homes, 0.19 ng/ml (GSD=2.17) in the e-cigarettes users’ homes, and 0.07 ng/ml (GSD=1.79) in the control homes. Salivary cotinine concentrations of the non-smokers exposed to e-cigarette's vapour at home (all exposed ≥2 h/day) were statistically significant different that those found in non-smokers exposed to second-hand smoke ≥2 h/day and in non-smokers from control homes. Conclusions: The airborne markers were statistically higher in conventional cigarette homes than in e-cigarettes homes (5.7 times higher). However, concentrations of both biomarkers among non-smokers exposed to conventional cigarettes and e-cigarettes’ vapour were statistically similar (only 2 and 1.4 times higher, respectively). The levels of airborne nicotine and cotinine concentrations in the homes with e-cigarette users were higher than control homes (differences statistically significant). Our results show that non-smokers passively exposed to e-cigarettes absorb nicotine. - Highlights: • This is the first study of e-cigarette exposure at home under real-use conditions. • Airborne nicotine in homes with smokers were 5.7 times higher than in e-cig homes. • Cotinine of non-smokers exposed to e-cig and conventional cigarettes was similar. • Airborne nicotine in homes with e-cig users was higher than control homes. • Cotinine of non-smokers exposed to e-cig users was higher than in those no exposed.

54 ENVIRONMENTAL SCIENCES↗

A Practical Approach to Wave Function Propagation, Hopping Probabilities, and Time Steps in Surface Hopping Calculations

We compare several established approaches for propagating wave functions and calculating hopping probabilities within the fewest switches surface hopping (FSSH) algorithm for difficult cases with many electronic states and many trivial crossings. If only a single time step (Δt c ) is employed, we find that no published approach can accurately capture the dynamics correctly unless Δt c → 0 (which is not computationally feasible). If multiple time steps are employed, for a fixed classical time step (Δt c ), a robust scheme can be found for dynamically choosing quantum time steps (δt q1 and δt q2 ) and calculating hopping probabilities so that one can systematically reduce all errors and achieve maximally efficient accuracy; scattering calculations confirm that one can choose a fairly large classical time step. Furthermore, the robust scheme presented here uses both the “local diabatic” and adiabatic interpolation and thus borrows elements from both the Granucci/Persico and Meek/Levine algorithms. Our findings should be broadly applicable in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple Element Infrared Synchrotron Mirrors

Multiple element focussing mirrors are simulated, with a novel design to correct for the spatially extended source in bending magnet infrared beamlines with large acceptance apertures. The calculated enhancement of the effective source brightness is a factor of 4.6 at lambda = 2 {mu}m, 2.5 at lambda = 10 {mu}m and 1.0 at lambda = 100 {mu}m.

43 PARTICLE ACCELERATORS↗

SDWFS-MT-1: A SELF-OBSCURED LUMINOUS SUPERNOVA AT z {approx_equal} 0.2

We report the discovery of a 6 month long mid-infrared transient, SDWFS-MT-1 (aka SN 2007va), in the Spitzer Deep, Wide-Field Survey of the NOAO Deep Wide-Field Survey Booetes field. The transient, located in a z = 0.19 low-luminosity (M{sub [4.5]} {approx_equal} -18.6 mag, L/L{sub *} {approx_equal} 0.01) metal-poor (12 + log(O/H) {approx_equal} 7.8) irregular galaxy, peaked at a mid-infrared absolute magnitude of M{sub [4.5]} {approx_equal} -24.2 in the 4.5 {mu}m Spitzer/IRAC band and emitted a total energy of at least 10{sup 51} erg. The optical emission was likely fainter than the mid-infrared, although our constraints on the optical emission are poor because the transient peaked when the source was 'behind' the Sun. The Spitzer data are consistent with emission by a modified blackbody with a temperature of {approx}1350 K. We rule out a number of scenarios for the origin of the transient such as a Galactic star, active galactic nucleus activity, {gamma}-ray burst, tidal disruption of a star by a black hole, and gravitational lensing. The most plausible scenario is a supernova (SN) exploding inside a massive, optically thick circumstellar medium, composed of multiple shells of previously ejected material. If the proposed scenario is correct, then a significant fraction ({approx}10%) of the most luminous SN may be self-enshrouded by dust not only before but also after the SN occurs. The spectral energy distribution of the progenitor of such an SN would be a slightly cooler version of {eta} Carinae peaking at 20-30 {mu}m.

79 ASTRONOMY AND ASTROPHYSICS↗

BREAKING THE LAW: THE M{sub bh}-M{sub spheroid} RELATIONS FOR CORE-SERSIC AND SERSIC GALAXIES

The popular log-linear relation between supermassive black hole mass, M{sub bh}, and the dynamical mass of the host spheroid, M{sub sph}, is shown to require a significant correction. Core galaxies, typically with M{sub bh} {approx}> 2 Multiplication-Sign 10{sup 8} M{sub Sun} and thought to be formed in dry merger events, are shown to be well described by a linear relation for which the median black hole mass is 0.36%-roughly double the old value of constancy. Of greater significance is that M{sub bh}{proportional_to}M{sup 2}{sub sph} among the (non-pseudobulge) lower-mass systems: specifically, log [M{sub bh}/M{sub Sun }] = (1.92 {+-} 0.38)log [M{sub sph}/7 Multiplication-Sign 10{sup 10} M{sub Sun }] + (8.38 {+-} 0.17). 'Classical' spheroids hosting a 10{sup 6} M{sub Sun} black hole will have M{sub bh}/M{sub sph} {approx} 0.025%. These new relations presented herein (1) bring consistency to the relation M{sub bh}{proportional_to}{sigma}{sup 5} and the fact that L{proportional_to}{sigma}{sup x} with exponents of 5 and 2 for bright (M{sub B} {approx}< -20.5 mag) and faint spheroids, respectively, (2) mimic the non-(log-linear) behavior known to exist in the M{sub bh}-(Sersic n) diagram, (3) necessitate the existence of a previously overlooked M{sub bh}{proportional_to}L{sup 2.5} relation for Sersic (i.e., not core-Sersic) galaxies, and (4) resolve past conflicts (in mass prediction) with the M{sub bh}-{sigma} relation at the low-mass end. Furthermore, the bent nature of the M{sub bh}-M{sub sph} relation reported here for 'classical' spheroids will have a host of important implications that, while not addressed in this paper, relate to (1) galaxy/black hole formation theories, (2) searches for the fundamental, rather than secondary, black hole scaling relation, (3) black hole mass predictions in other galaxies, (4) alleged pseudobulge detections, (5) estimates of the black hole mass function and mass density based on luminosity functions, (6) predictions for space-based gravitational wave detections, (7) connections with nuclear star cluster scaling relations, (8) evolutionary studies over different cosmic epochs, (9) comparisons and calibrations matching inactive black hole masses with low-mass active galactic nucleus data, and more.

79 ASTRONOMY AND ASTROPHYSICS↗