Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Detection of x-ray emission in a nanosecond discharge in air at atmospheric pressure

Measurement of x-ray emission is an important parameter to investigate runaway behavior of fast electrons produced in nanosecond-pulse gas discharge. An online detection system of x rays is described in this paper, and the system consists of an x-ray detector with NaI (Tl) scintillator and photomultiplier tube, and an integrated multichannel analyzer. The system is responsible for detecting x-ray emission signal, processing the detected signals, and scaling the energy distribution. The calibration results show that every channel of the detection system represents a given x-ray energy and various x rays can be divided into different energy ranges between 10 and 130 keV. For a repetitive nanosecond-pulse breakdown between highly nonuniform gaps in open air, an energy distribution is obtained using the online detection system. It shows that the x-ray emission is a continuous spectrum and the x rays of above 60 keV dominate in the detected energy distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic and time-resolving ability of pulse-pair two-dimensional velocity interferometry

Previous velocity interferometers used at research laboratories for shock physics experiments measured target motion at a point or many points on a line on the target. Recently, a two-dimensional (2d) version (2d-velocity interferometer system for any reflector) has been demonstrated using a pair of ultrashort (3 ps) pulses for illumination, separated by 268 ps. We have discovered new abilities for this instrument, by treating the complex output image as a hologram. For data taken in an out of focus configuration, we can Fourier process to bring narrow features such as cracks into sharp focus, which are otherwise completely blurred. This solves a practical problem when using high numerical aperture optics having narrow depth of field to observe moving surface features such as cracks. Furthermore, theory predicts that the target appearance (position and reflectivity) at two separate moments in time are recorded by the main and conjugate images of the same hologram, and are partially separable during analysis for narrow features. Hence, for the cracks we bring into refocus, we can make a two-frame movie with a subnanosecond frame period. Longer and shorter frame periods are possible with different interferometer delays. Since the megapixel optical detectors we use have superior spatial resolution over electronic beam based framing cameras, this technology could be of great use in studying microscopic three-dimensional-behavior of targets at ultrafast times scales. Demonstrations on shocked silicon are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced analysis of laser-driven pulsed magnetic diffusion based on quantum molecular dynamics simulation

Magnetic diffusion plays an important role in inertial confinement fusion with strong magnetic fields. In this paper, we improve a previous analysis of the generation and diffusion of the magnetic field [Morita et al., Phys. Plasmas 25, 094505 (2018)]. For the generation process, we calculate the temporal evolution of the coil current using a self-consistent circuit model. The results show that the peak of the calculated magnetic field is delayed by 1.2 ns compared with that of the incident laser pulse. For the diffusion process, we evaluate the electrical conductivity of warm dense gold over a wide temperature range (300 K–100 eV) by combining the Kubo–Greenwood formula based on a quantum molecular dynamics simulation with the modified Spitzer model. Our simulation shows that the maximum magnetic field (530 T) that penetrates the cone is delayed by 2.5 ns compared with the laser peak. This result is consistent with experiments [Sakata et al., Nat. Commun. 9, 3937 (2018)] that showed that applying a strong magnetic field improved the heating efficiency of fusion fuel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-resolved investigation of subnanosecond radiation from Al wire hybrid X pinches

K-shell x-ray spectra from Al wire hybrid X pinches have been studied using an x-ray streak camera with better than 0.1-ns time resolution together with a Focusing Spectrograph with Spatial Resolution (FSSR) spectrograph. High-intensity radiation with a continuumlike spectrum was observed in the subnanosecond initial phase of the x-ray pulse generated by the hybrid X pinch (HXP). Here, the absence of spectral lines in this phase and the extremely small x-ray source size indicates the importance of radiative processes in the final phase implosion dynamics. Plasma parameters in the following phases of the HXP were determined from analysis of the line intensities. Point-projection radiography together with a slit-step wedge camera and an FSSR spectrograph without time resolution were used to show the number of radiation sources, and to give information on the time-integrated photon energy spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isotopic Substitution Reveals the Importance of Aluminate Diffusion Dynamics in Gibbsite (Al(OH) 3 ) Crystallization from Alkaline Aqueous Solution

Understanding molecular-scale factors governing the precipitation of aluminum hydroxides, such as gibbsite, under alkaline conditions is important for the formation of laterite deposits, as well as aluminum processing. However, mechanisms enabling tetrahedral aluminate ions to assemble into octahedral sites of the gibbsite lattice remain unclear. Formation of oligomeric complexes has been hypothesized as a critical intermediate step. Here, we report a study of gibbsite solubility in highly alkaline solutions using deuterium substitution to probe equilibrium and kinetic factors that could affect oligomeric intermediate formation, including the reactivity and the diffusivity of aluminate ions. When substituting sodium hydroxide with sodium deuteroxide, solution analysis shows a nearly 40% and 50% increase in gibbsite solubility in 2.4 and 3.3 mol·kg –1 total sodium solutions, respectively. Raman spectroscopy indicated that monomeric aluminate ions are the predominant species in solution irrespective of deuteration. However, both 27 Al and 23 Na nuclear magnetic resonance (NMR) spectroscopy revealed significant differences in chemical shifts in deuterated solutions, and analysis of 1 H, 23 Na, and 27 Al diffusion coefficients with pulsed-field gradient, stimulated echo NMR spectroscopy shows a decrease in ion diffusivity with increasing total deuterium in solution, consistent with the notion of increasing strength in the hydrogen/deuterium bonding network. In conclusion, because the relative change in 1 H diffusion coefficients are commensurate with the difference in apparent solubility constants, there is evidence for an oligomeric intermediate whose steady-state concentration is maintained by the collision frequency of aluminate ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First results of the silicon telescope using an 'artificial retina' for fast track finding

We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecture is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant spontaneous bremsstrahlung by an electron scattered by a nucleus in the field of a pulsed light wave

Resonant spontaneous bremsstrahlung by an electron scattered by a nucleus in the field of a pulsed light wave is theoretically investigated. The approximation is examined when the pulse width is considerably greater than the characteristic time of wave oscillations. The electron interaction with the Coulomb potential of a nucleus is considered in the Born approximation. An analytic expression for the resonant differential cross section of the investigated process was obtained for the range of moderately strong fields. The bremsstrahlung cross section contains a resonant peak. The resonant peak's altitude and width are defined by the external pulsed wave properties. The resonant cross section is studied within the ranges of nonrelativistic, relativistic, and ultrarelativistic electron energies. It is demonstrated that the resonant cross section of spontaneous bremsstrahlung may be several orders of magnitude greater than the corresponding cross section in the absence of an external field. Results obtained may be experimentally verified, for example, by the scientific facilities at the SLAC National Accelerator Laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simultaneous X-ray diffraction and phase-contrast imaging for investigating material deformation mechanisms during high-rate loading

Using a high-speed camera and an intensified charge-coupled device (ICCD), a simultaneous X-ray imaging and diffraction technique has been developed for studying dynamic material behaviors during high-rate tensile loading. A Kolsky tension bar has been used to pull samples at 1000 s -1 and 5000 s -1 strain-rates for super-elastic equiatomic NiTi and 1100-O series aluminium, respectively. By altering the ICCD gating time, temporal resolutions of 100 ps and 3.37 µs have been achieved in capturing the diffraction patterns of interest, thus equating to single-pulse and 22-pulse X-ray exposure. Furthermore, the sample through-thickness deformation process has been simultaneously imaged via phase-contrast imaging. It is also shown that adequate signal-to-noise ratios are achieved for the detected white-beam diffraction patterns, thereby allowing sufficient information to perform quantitative data analysis diffraction via in-house software ( WBXRD_GUI ). Of current interest is the ability to evaluate crystal d -spacing, texture evolution and material phase transitions, all of which will be established from experiments performed at the aforementioned elevated strain-rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New techniques of low level environmental radiation monitoring at JLab

We present the first long-term environmental radiation monitoring results obtained using the technique of pulse mode readout for the industry-standard Reuter-Stokes RSS-1013 argon-filled high pressure ionization chambers (HPIC). With novel designs for the front-end electronics readout and customized signal processing algorithms, we are capable of detecting individual events of gas ionization in the HPIC, caused by interactions of gammas and charged particles in the gas. The technique provides enough spectroscopic information to distinguish between several different types of environmental and man-made radiation. The technique also achieves a high degree of sensitivity and stability of the data, allowing long-term environmental radiation monitoring with unprecedented precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARCS Replacement at TREAT for TRTR 2020 - Abstract

The Transient REActor Test (TREAT) facility was restarted in 2017 to perform reactor fuels testing under transient conditions, following shutdown in 1994 and 23 years in non-operational standby. TREAT is a transient reactor that, like most pulsing reactors, can create natural shaped power pulses. However, TREAT provides the ability to shape the power pulse and control the energy deposition rate on the test specimens by automatically controlling the amount of reactivity insertion over time. The original automatic reactor control system (ARCS) was created in the 1980s using INTEL 8086 CPU boards and software written in assembly code. The need to maintain the system for the next 40+ years of TREAT life led to the decision to replace ARCS with modern hardware while maintaining the original functionality. After a prototyping effort, the replacement was successfully completed in the first quarter of 2020. The process and results of that effort are reported here.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of laser UV radiation on the eye scleral tissue in patients with open-angle glaucoma

We report the results of an experimental study of the effect of short-pulse laser UV radiation on the eye scleral tissue. As samples, we used isolated flaps of the eye scleral tissue from the patients with open-angle glaucoma of the second and third stages. The impact was implemented using the radiation of an excimer XeCl laser with a wavelength of 308 nm and a laser with a wavelength tunable within from 210 to 355 nm. Depending on the problem to be solved, the energy density on the surface of the irradiated tissue varied from a fraction of mJ cm{sup –2} to 15 J cm{sup –2}. For the first time we studied the optical properties of the intraocular fluid in the UV and blue spectral range. The study of the ablation process under the action of radiation with a wavelength of 308 nm showed that the rate of material evaporation can vary within 24 % – 30 % at an energy density above 7 J cm{sup –2}, depending on the glaucoma stage and the individual features of a patient. The excitation – emission matrices of laser-induced fluorescence (LIF) of the eye scleral tissue were studied experimentally using a laser with a wavelength tuned in the range 210 – 355 nm. We found the differences in the LIF spectra caused by the excitation wavelength and the open-angle glaucoma stage. (laser medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed x-ray imaging with the Keck pixel array detector (Keck PAD) for time-resolved experiments at synchrotron sources

Modern storage rings are readily capable of providing intense x-ray pulses, tens of picoseconds in duration, millions of times per second. Exploiting the temporal structure of these x-ray sources opens avenues for studying rapid structural changes in materials. Many processes (e.g. crack propagation, deformation on impact, turbulence, etc.) differ in detail from one sample trial to the next and would benefit from the ability to record successive x-ray images with single x-ray sensitivity while framing at 5 to 10 MHz rates. To this end, we have pursued the development of fast x-ray imaging detectors capable of collecting bursts of images that enable the isolation of single synchrotron bunches and/or bunch trains. The detector technology used is the hybrid pixel array detector (PAD) with a charge integrating front-end, and high-speed, in-pixel signal storage elements. A 384×256 pixel version, the Keck-PAD, with 150 µm × 150 µm pixels and 8 dedicated in-pixel storage elements is operational, has been tested at CHESS, and has collected data for compression wave studies. An updated version with 27 dedicated storage capacitors and identical pixel size has been fabricated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Burst design and signal processing for the speed of sound measurement of fluids with the pulse-echo technique

The pulse-echo technique determines the propagation time of acoustic wave bursts in a fluid over a known propagation distance. It is limited by the signal quality of the received echoes of the acoustic wave bursts, which degrades with decreasing density of the fluid due to acoustic impedance and attenuation effects. Signal sampling is significantly improved in this work by burst design and signal processing such that a wider range of thermodynamic states can be investigated. Applying a Fourier transformation based digital filter on acoustic wave signals increases their signal-to-noise ratio and enhances their time and amplitude resolutions, improving the overall measurement accuracy. In addition, burst design leads to technical advantages for determining the propagation time due to the associated conditioning of the echo. It is shown that the according operation procedure enlarges the measuring range of the pulse-echo technique for supercritical argon and nitrogen at 300 K down to 5 MPa, where it was limited to around 20 MPa before.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of High-efficiency and Cost-effective Forged Ingot Niobium Technology for Science Frontiers and Accelerator Applications

Development of Forged Ingot Niobium Technology: Worlds science frontier programs and SRF accelerator applications demand high performance and cost-effective SRF accelerator technology [1-8]. Fine-grain (FG) and Large-grain (LG) ingot niobium technologies have been very well developed and implemented in all the present-day accelerator projects. However, forged ingot niobium technology which is the focus of this development proposal will be much more cost-effective and expected to have several technical advantages. FG niobium sheet production is very complex involving more than ten processing steps making them prone to contamination. As a result, they are very expensive to produce and require stringent QA procedure to be ready for SRF cavity production. The accelerating cavity process steps are also numerous and require strict procedures in order to achieve high accelerating gradients and quality factors needed for science frontier programs. LG niobium disc production, directly sliced from the ingot, is relatively simple and straight forward to keep surface cleanness. The disc production cost is significantly low compared to FG niobium sheet production. However, there are (some) draw backs due to non-homogeneity of the grain boundary distribution, resulting in non-uniform mechanical properties and complex cavity fabrication, although the LG cavities achieve the expected high-gradient performance goals with lower cost. Medium-grain (MG) niobium disk production may be realized with a new approach/process, the disc directly sliced from the forged ingot, involves a simpler process steps contributing major production cost reduction [9]. These discs are expected to be superior as they tend to be homogenous with uniform sub millimeter grains and mechanical properties. We are eagerly looking forward to developing the forged ingot niobium SRF accelerator technology for the benefit of the world-wide science frontier programs, green energy subcritical nuclear energy systems and a wide variety of industrial applications including the production of radio isotopes and nuclear transmutation applications. Measurement of thermal characteristics of the forged ingot niobium: Measurement of the thermal diffusivity, D, of superconducting MG niobium is important to be understood in comparison with FG sheet and LG disc, as well as that of advanced composite material of Nb3Sn film sputtered on forged ingot Nb, which will be determined using transient pump-probe thermo-modulation [10,11]. Transient thermo-modulation is based on using an ultrafast laser pulse to heat the superconducting materials by a few K, then a synchronized laser pulse probes the reflectance of the heated material. For thin films on a substrate (e.g, 100-nm Nb3Sn on Nb), it takes <100 ps for the heat to reach the substrate by diffusion. Therefore, an ultrafast method is needed to probe D of the studied material. D will be measured from room temperature to liquid helium temperatures. Fundamental Research: The increase of rf loss in SRF cavities is related to trapping of residual magnetic field during the cavity cool-down. The study suggested that the micro structure plays the role in flux trapping sensitivity. The research includes the flux trapping and expulsion study as forged ingot niobium goes through several mechanical deformations, crystallization leading to the optimal SRF cavity performance. Furthermore, the cavity made from FG, MG, and LG sheet/disc will be compared to understand the optimal re-crystallization temperature that cavity needed to be heat treated which minimize the flux trapping and increase SRF cavity performance. References: 1. S. Belomestnykh, Overview of recent SRF developments for ERLs, presented at the SRF 2015, Whistler, BC, Canada (2015). 2. A. Yamamoto, M. Yamanaka and G. Myneni, Ingot Nb based SRF Technology for the International Linear Collider, in Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications, AIP Conf. Proc. 1687, 030005-1 ? 03005-6, 2015 3. Report of the Workshop on Energy and Environmental Applications of Accelerators, DOE Workshop Report. https://science.osti.gov/-/media/hep/pdf/Reports/2020/CASM_WorkshopReport.pdf? la=en&hash=AEB0B318ED0436B1C5FF4EE0FDD6DEB84C2F15B2 4. G. Ciovati, et al., Design of a cw, low-energy, high-power superconducting linac for environmental applications, Phys. Rev. Accel. Beams 21, 091601 (2018). 5. P. Dhakal, et al., Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity, Phys. Rev. ST Accel. Beams 16, 042001 (2013). 6. P. Kneisel et al., Review of ingot niobium as a material for superconducting radio frequency accelerating cavities, Nuclear Instruments and Methods in Physics Research A 774, 133 (2015). 7. G. Ciovati, P. Dhakal, and G. R, Myneni, Superconducting radio-frequency cavities made from medium and low-purity niobium ingots, Supercond. Sci. Technol. 29, 064002 (2016). 8. M. Drury et al., commissioning of the prototype C75 cavities in a CEBAF cryomodule, in Proc. of IPAC 2018, Vancouver, BC, Canada (2018) 9. Feasibility of forged-ingot niobium disc and SRF cavity fabrication technology recently demonstrated in cooperation of ATI, BSCE, and KEK (2020). 10. Hani E. Elsayed-Ali, ?Measurements of heat transport in thin films by ultrafast laser-based techniques,? 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications, Cairo, Egypt, pp. 347 ? 350 (2010). DOI: 10.1109/ThETA17616.2010 11. W. M. G. Ibrahim, H. E. Elsayed-Ali, M. Schinn, and C. A. Bonner, Jr., ?Ultrafast investigation of electron dynamics in multilayer metals,? Int. J. Heat and Mass Transfer, 47(10?11), 2261?2268 (2004).

Myneni, G.↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Experimental modelling of the physical process of laser tattoo removal

Two model objects are proposed to study the physical mechanism of tattoo removal using nano-, pico-, and femtosecond laser pulses. Experimental results on laser decolourisation of cotton fabric coloured with black tattoo ink and a pig skin sample with tattoo ink deposited on its rear side, in dependence of the duration, energy, and number of laser pulses and the laser spot size, are presented and discussed. It is established that decolourisation of cotton fabric and pig skin without their destruction occurs under irradiation with ultrashort laser pulses and is absent in the case of nanosecond pulses. An analysis of the results obtained has made it possible to draw a number of conclusions, useful for gaining a better insight into the physical mechanism of laser tattoo removal. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revealing the role of electron-electron correlations by mapping dissociation of highly excited D 2 + using ultrashort XUV pulses

Understanding electron-electron correlations in matter ranging from atoms to solids represents a grand challenge for both experiment and theory. Here, these correlations occur on attosecond timescales and have only recently become experimentally accessible. In the case of highly excited systems, the task of understanding and probing correlated interactions is even greater. In this work, we combine state-of-the-art light sources and advanced detection techniques with ab initio calculations to unravel the role of electron-electron correlation in D 2 photoionization by mapping the dissociation of a highly excited D 2 + molecule. Correlations between the two electrons dictate the pathways along which the molecule dissociates and lead to a superposition of excited ionic states. Using 3D Coulomb explosion imaging and electron-ion coincidence techniques, we assess the relative contribution of competing parent ion states to the dissociation process for different orientations of the molecule with respect to the laser polarization, which is consistent with a shake-up ionization process. As a step toward observing coherent superposition experimentally, we map the relevant nuclear potentials using Coulomb explosion imaging and show theoretically that such an experiment could confirm this coherence via two-path interference.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent developments in deuterated scintillators for neutron measurements at low-energy accelerators

Deuterated ( 2 H-based) organic scintillators, unlike conventional 1 H-based scintillators can generate pulse-shape gated neutron energy spectra 1 to 30 MeV without need for time-of-flight (ToF). They are especially appropriate for measurements at high-intensity, low-energy accelerators where a pulsed beam is not available. Even when the latter is available, the loss in effective beam intensity combined with the need for suitable long-path ToF measurements can be very inefficient. In contrast, as we demonstrate, arrays of d- benzene scintillators (NE230, BC537, EJ315) and recently xylene-d10 (EJ301D) together with related digital signal processing (DSP) can provide highly efficient neutron energy measurements w/o n-ToF. Lastly, we also report the recent synthesis and initial testing of crystalline d-stilbene as a neutron detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗