Search NASA⌕ Search

SEARCH · Search NASA

Results for “optimization analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Fourier Analysis-Based Evolutionary Multi-Objective Multiphysics Optimization of Liquid-Cooled Heat Sinks

Optimal heat dissipation in power modules can significantly increase their power density. Removing the generated heat is critical for capturing the benefits of advanced semiconductor materials and improving the reliability of the device operation. This article proposes a design optimization method for liquid-cooled heat sinks that use a Fourier analysis-based tool and an evolutionary optimization algorithm to optimize the heat sink geometry for specified objectives. The optimized heat sink geometry is then compared with state-of-the-art solutions in literature based on finite element analysis of different designs. The proposed methodology can develop complex geometries that outperform the conventional heat sink geometries.

Sahu, Raj↗

Theoretical Analysis of Critical Conditions for Crack Formation and Propagation, and Optimal Operation of SOECs

A theoretical analysis on crack formation and propagation was performed based on the coupling between the electrochemical process, classical elasticity, and fracture mechanics. The chemical potential of oxygen, thus oxygen partial pressure, at the oxygen electrode-electrolyte interface ( μ O 2 OE∣El ) was investigated as a function of transport properties, electrolyte thickness and operating conditions (e.g., steam concentration, constant current, and constant voltage). Our analysis shows that: a lower ionic area specific resistance (ASR), r i O E , and a higher electronic ASR ( r e O E ) of the oxygen electrode/electrolyte interface are in favor of suppressing crack formation. The μ O 2 O E ∣ E l , thus local pO 2 , are sensitive towards the operating parameters under galvanostatic or potentiostatic electrolysis. Constant current density electrolysis provides better robustness, especially at a high current density with a high steam content. While constant voltage electrolysis leads to greater variations of μ O 2 O E ∣ E l . Constant current electrolysis, however, is not suitable for an unstable oxygen electrode because μ O 2 O E ∣ E l can reach a very high value with a gradually increased r i O E . A crack may only occur under certain conditions when p O 2 T P B > p c r .

42 ENGINEERING↗

Numerical analysis and wave tank validation on the optimal design of a two-body wave energy converter

To improve the performance of a ‘point absorber’ type wave energy converter (WEC), an additional submerged body can be deployed. The submerged body can be used to increase the equivalent excitation force on the WEC, as well as provide resonance tuning. This paper presents numerical analysis and experimental validation of a two-body point absorber type WEC using a mechanical motion rectifier (MMR) based power takeoff. The two-body point absorber consists of a floating buoy connected to a neutrally buoyant submerged body via the power-takeoff. The mechanical motion rectifier and a ball screw translate the relative heave motion of the two bodies into unidirectional rotation, which in turn spins a generator. Frequency domain analysis suggests there is an optimal submerged body mass for maximum WEC power absorption. Regular wave simulations in the time domain are compared to the results obtained in the frequency domain. While the time domain and frequency domain results predict the same optimal mass ratio, time domain analysis provides a more complex and accurate power result. To validate the time domain model, experimental wave tank testing is conducted using a 1:30 scale model WEC. The experiment shows the two-body WEC can produce twice the amount of power as the single-body WEC with same floating buoy and can be further increased by PTO design and power electronics optimization. Furthermore, wave tank testing shows the two-body WEC has a capture width ratio up to 58% at 59 kW/m and 51% at 36 kW/m.

16 TIDAL AND WAVE POWER↗

Optimizing Energy Efficiency of Plants: Quantitative Analysis of Carbon Flux

The efficiency in harvesting light energy is essential for both crop and feedstock productivity. Key targets for optimization of energy efficiency include energy capture, conversion, translocation and storage. Surprisingly little is known about the mechanisms of carbon allocation and the communication between source and sink. We surmise that regulatory networks that coordinate carbon partitioning and allocation might be control points and thus suitable for optimization by engineering. At a first step towards identifying such regulatory networks, our lab identified key players in missing steps of allocation, specifically cellular sugar uptake (SUT family, founding members identified by my team) and cellular efflux carriers (SWEET superfamily, founding members identified by my team). In plants, both classes of transporters are encoded by multigene families. We show that specific subsets of SWEETs serve critical roles in cellular sucrose efflux in the leaf for phloem loading, in seeds for seed filling, as well as in nectar section and vacuolar storage; similarly SUTs play critical roles in cellular uptake during phloem loading and seed filling. Access to the plant SWEETs provided the clues needed for identifying novel bacterial and human sugar transporters. Moreover, we found that pathogens hijack SWEETs to access the plants energy resources. In contrast to SUTs, which are predominantly proton symporters, SWEETs appear to function as facilitators, and thus must be tightly regulated to prevent spillover of carbon into cell walls. One of the key goals of this project was to identify such carriers, characterize the role of key members in carbon allocation. To decrypt the biological circuits we need novel diagnostic tools that, analogous to oscilloscopes in electrical engineering of circuit boards, allow us to quantify fluxes; here by monitoring sugars. Such probes can provide crucial information on systems properties such as metabolic impedance. To measure steady state metabolite levels with minimal invasive methods, and to develop impedance measurements in vivo, we constructed and optimized a set of probes, namely Förster Resonance Energy Transfer (FRET) nanosensors for glucose and sucrose. The probes monitor the concentration of a specific metabolite with high temporal resolution, and, since encoded genetically, can be targeted to specific cells or even specific cellular compartments and thus obtain measurements with cellular and subcellular resolution. We also developed a new platform for monitoring such sensors in vivo, the RootChip.

09 BIOMASS FUELS↗

Miniaturized Air-to-Refrigerant Heat Exchangers

Air-to-refrigerant Heat eXchangers (HX) are an essential component of Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems, serving as the main heat transfer component. The major limiting factor to HX performance is the large airside thermal resistance. Recent literature aims at improving heat transfer performance by utilizing enhancement methods such as fins and small tube diameters; this has lead to almost exhaustive research on the microchannel HX (MCHX). The objective of this project is to develop a miniaturized air-to-refrigerant HX with at least 20% reduction in volume, material volume, and approach temperature compared to current state-of-the-art multiport flat tube designs and also be capable of production within five years. Moreover, the proposed HX’s are expected to have good water drainage and should succeed in both evaporator and condenser applications. The project leveraged Parallel-Parametrized Computational Fluid Dynamics (PPCFD) and Approximation-Assisted Optimization (AAO) techniques to perform multi-scale analysis and shape optimization with the intent of developing novel HX designs whose thermal-hydraulic performance exceeds that of state-of-the-art MCHX. Nine heat exchanger geometries were initially chosen for detailed analysis, selected from 35+ geometries which were identified in previous work at the University of Maryland, College Park. The newly developed optimization framework was exercised for three design optimization problems: (DP I) 1.0kW radiator, (DP II) 10kW radiator and (DP III) 10kW two-phase HX. DP I consisted of the design and optimization of 1.0kW air-to-water HX’s which exceeded the project requirements of 20% volume/material reduction and 20% better performance. Two prototypes for the 1.0kW HX were prototyped, tested and validated using newly-designed airside and refrigerant side test facilities. DP II, a scaled version DP I for 10kW air-to-water HX applications, also yielded optimized HX designs which met project requirements. Attempts to prototype a 10kW have presented unique manufacturing challenges, especially regarding tube blockages and structural stability. DP III comprised optimizing two-phase HX’s for a 3.0Ton capacity in a heat pump / air-conditioning unit for cooling mode application using R410A as the working fluid. The HX’s theoretically address the project requirements. System-level analysis showed the HX’s achieved up to 15% improvement in COP while also reducing overall unit charge by 30-40%. The project methodology was capable of developing HX’s which can outperform current state-of-the-art MCHX by at least 20% reduction in volume, material volume, and approach temperature. Additionally, the capability for optimization using refrigerant charge as an objective function was developed. The five-year manufacturing feasibility of the proposed HX’s was shown to have a good outlook. Successful prototyping through both conventional manufacturing methods and next generation methods such as additive manufacturing was achieved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sustainable recovery of critical metals from spent lithium-ion batteries through gluconic acid-based bioleaching: Techno-economic analysis, life cycle assessment and process optimization

Recycling spent lithium-ion batteries (LIB) could potentially bridge the ever increasing supply and demand gap for critical metals and simultaneously facilitate the management of hazardous battery waste. This study investigated the optimization of gluconic acid-based bioleaching technology through design of experiments (DOE), combined with techno-economic analysis (TEA), and life cycle assessment (LCA) with the aim of maximizing the net present value (NPV) and minimizing global warming impacts of the process. Biolixiviant containing predominantly gluconic acid produced by the genetically engineered (ΔpstS, P 112 :mgdh) Gluconobacter oxydans B58 through fermentation using non-recyclable paper as a growth substrate was used for the LIB leaching. At optimal bioleaching conditions of gluconic acid (160 mM), leaching time (2.5 h), reducing agent FeSO 4 to metal, i.e., cobalt (Co), nickel (Ni) and manganese (Mn), mole ratio (0.88), temperature (55 °C) and pulp density (2.5 %), the leaching efficiency was 87 % 72 %, 94 %, and 88 % for Co, Ni, Mn and lithium (Li), respectively. TEA analysis confirmed that bioleaching plant with an annual black mass processing capacity of 10,000 metric tons and plant life of 30 years would be economically viable with an NPV and profit margin of $136 million and 11 %, respectively. The predicted carbon footprint of gluconic acid-based bioleaching for recovering 1 kg of Co (13.2 kg of CO 2 eq.) is lower compared to that of most state-of-the-art leaching technologies. Moreover, gluconic acid-based bioleaching effectively recovered target metals when tested for different black mass chemistries.

Bioleaching↗

Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis

Here, this study performs a techno-economic analysis of hydrogen underground storage systems for grid electricity storage, evaluating their economic viability at the plant scale using dynamic optimization. It explores the feasibility of various system configurations and revenue models in the context of volatile electricity prices and the necessity for multiple revenue streams. The hypothesis tested is that large-scale hydrogen storage, despite its low round-trip efficiency, can be economically viable with the right mix of revenue streams. This study uses scenario-based analysis to assess the impacts of different system configurations, including engaging in time-shifting arbitrage, ancillary service markets and blending hydrogen with natural gas. Results indicate potential annual net cash flows of up to $\$$1.5 million from ancillary services integration and $\$$5.2 million from natural gas blending, contingent on specific system sizes. The study concludes that hydrogen underground storage for grid electricity storage can be profitable, and emphasizes that proper system design and precise electricity price forecasting are crucial for optimizing system performance and economic returns. This research sets the stage for further investigations into the scalability of hydrogen storage systems and their broader implications for grid electricity storage and energy market dynamics.

25 ENERGY STORAGE↗

Statistical Analysis of Solar PV Power Frequency Spectrum for Optimal Employment of Building Loads

In this paper, a statistical analysis of the frequency spectrum of solar photovoltaic (PV) power output is conducted. This analysis quantifies the frequency content that can be used for purposes such as developing optimal employment of building loads and distributed energy resources. One year of solar PV power output data was collected and analyzed using one-second resolution to find ideal bounds and levels for the different frequency components. The annual, seasonal, and monthly statistics of the PV frequency content are computed and illustrated in boxplot format. To examine the compatibility of building loads for PV consumption, a spectral analysis of building loads such as Heating, Ventilation and Air-Conditioning (HVAC) units and water heaters was performed. This defined the bandwidth over which these devices can operate. Results show that nearly all of the PV output (about 98%) is contained within frequencies lower than 1 mHz (equivalent to ~15 min), which is compatible for consumption with local building loads such as HVAC units and water heaters. Medium frequencies in the range of ~15 min to ~1 min are likely to be suitable for consumption by fan equipment of variable air volume HVAC systems that have time constants in the range of few seconds to few minutes. This study indicates that most of the PV generation can be consumed by building loads with the help of proper control strategies, thereby reducing impact on the grid and the size of storage systems.

boxplot↗

ARCUS Vertical-Axis Wind Turbine (Final Scientific/Technical Report)

While land-based wind energy has become economically competitive with traditional energy generation sources in the U.S., offshore wind is not. For floating offshore wind this difference is even more substantial where the levelized cost of energy (LCOE) is projected to be around 3-5 times more expensive than land-based wind. The turbine capital costs represent around 50% of the LCOE for land-based wind sites, but the increased system costs for floating offshore wind reduce this to 20%. The platform and mooring costs are the single largest contributor to the LCOE for floating offshore wind where their mass must counteract the overturning moment caused by the turbine’s thrust force. Despite the high costs of the platform and relatively low cost of the turbine, current offshore wind turbines are designed essentially the same as for land-based sites. Reducing the LCOE is the greatest challenge to realize the benefits of sustained development of floating offshore wind in the U.S. Reducing the complicated system costs of floating offshore wind will enable the industry to continue to grow and outpace current projections if reduced cost curves can be reached. The ideal wind energy system would remove all mass and cost that is not directly capturing energy from the wind. For floating offshore wind energy systems, this objective is even more significant as increased mass above the water level must be supported by larger and more expensive floating platforms. For this reason, vertical-axis wind turbines (VAWTs) are ideal for floating offshore sites and have several advantages over horizontal-axis wind turbines (HAWTs) at this scale. Large VAWTs offer opportunities for improved energy capture over HAWTs as single units and with reduced wind plant aerodynamic losses through enhanced wake recovery. Additionally, the platform-level placement of the VAWT drivetrain greatly reduces the demands placed on the floating platform and its mass and cost. The ARCUS vertical-axis wind turbine concept (U.S. 11,421,650 B2) is an iteration beyond traditional Darrieus-type VAWTs that replaces the rigid tower with blades that are bent into shape and held in place with tensioned center supports, like a bow. The ARCUS design has been shown to further decrease the VAWT rotor mass properties, with a 50% reduction over traditional Darrieus VAWTs quantified in the ATLANTIS program. The ARCUS VAWT’s efficient use of material for the rotor and turbine support structures combined with its lowered center of gravity enables a tension-leg platform (TLP) with simplified installation procedures. TLPs have been an emerging platform architecture in the Oil and Gas industry and demonstrated to have the lowest hull mass requirements while maintaining stability with minimal roll and pitch deflections in operation. A 22 MW ARCUS turbine has been designed with a three-column TLP that enables quayside integration of the turbine while maintaining system stability during tow-out and installation and having optimal mass and cost properties. A comprehensive analysis shows the optimal ARCUS TLP system design minimizes LCOE through efficient material usage and increased energy capture to yield a competitive LCOE estimate of $\$$55/MWh. A comparison with a reference HAWT, having the same swept area, quantifies the advantages that helped to produce this improved LCOE for the ARCUS concept: (1) 30% reduction in total turbine mass, (2) 70% reduction in turbine center of gravity, and (3) 45% increase in energy production over what is optimal for a HAWT. Intellectual property has been generated through the ATLANTIS program providing opportunities to further reduce the LCOE and improve the performance of the ARCUS turbine and TLP system, expanding the list of innovations to support commercial development of the ARCUS concept.

17 WIND ENERGY↗

Integration of Experimental Hydroprocessing and FCC Data with Process (Aspen Plus) and Refinery Optimization (Aspen PIMS) Models

NREL's Economic, Sustainability, and Market Analysis (ESMA) team develops process models in Aspen Plus to support techno-economic analysis (TEA) and life-cycle assessment (LCA) of conversion pathways from renewable and circular resources to fuels and chemicals. These tools are being applied to assess probable operational constraints or bottlenecks associated with refinery co-processing and repurposing opportunities. The team also utilizes optimizable refinery models to quantify opportunities for biofuel and bioproduct pathways through integration with existing refining infrastructure. The goals of analysis are to model the transition of refineries to renewable and circular feedstocks and quantify the costs production and CO2 abatement through utilization of existing refineries. At the core of the ESMA team's work is the process data derived from conversion experiments on hydroprocessing and fluid catalytic cracking performed at NREL. The objective of this presentation is to highlight new analysis approaches and capabilities in pathway analysis and refinery optimization modeling with specific emphasis on integration of experimental data.

BIOMASS FUELS,ENERGY PLANNING, POLICY, AND ECONOMY↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Optimizing Federal Fleet Vehicle Acquisitions: An Eleven-Agency FY 2012 Analysis

This report focuses on the National Renewable Energy Laboratory's (NREL) fiscal year (FY) 2012 effort that used the NREL Optimal Vehicle Acquisition (NOVA) analysis to identify optimal vehicle acquisition recommendations for eleven diverse federal agencies. Results of the study show that by following a vehicle acquisition plan that maximizes the reduction in greenhouse gas (GHG) emissions, significant progress is also made toward the mandated complementary goals of acquiring alternative fuel vehicles, petroleum use reduction, and alternative fuel use increase.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

25 ENERGY STORAGE↗

Implementation of an Orificing Optimization Algorithm in the DASSH Subchannel Analysis Code

The Ducted Assembly Steady-State Heat transfer code (DASSH) performs full-core subchannel thermal hydraulics calculations in liquid metal fast reactors. One of the applications of subchannel codes is to optimize coolant flow orificing. As a design activity, the primary task is to determine the best way to divide assemblies into groups and distribute coolant flow rates among them. This report documents an algorithm implemented in DASSH to automatically optimize coolant orificing. Over the course of multiple iterations, DASSH determines the orifice grouping and flow distribution that minimizes peak coolant, clad, or fuel temperatures across all timesteps for a user-specified number of assembly groups. The total coolant flow rate in the reactor is constrained to achieve the specified core-average outlet temperature. The flow rate to each orifice group may also be constrained by the allowable pressure drop. The distribution of coolant flow among groups is accelerated using a predictor-corrector algorithm based on interpolated results from single-assembly parametric calculations. The assembly orificing grouping is initially predicted based on assembly power but can be refined if results demonstrate that an assembly would fit better in another group. The algorithm is demonstrated with two case studies. The first is a simple model for a reactor core consisting of just fuel assemblies; the pin power distributions are specified to create a situation where the initial assembly grouping prediction is suboptimal. This example is used to describe the initial grouping, demonstrate convergence over multiple iterations, and highlight the impact of regrouping. Then, the algorithm is applied to minimize peak clad and fuel temperatures in an example sodium-cooled fast reactor, the Versatile Test Reactor. The multicycle optimization confirms prior calculations for the reference core design. The example highlights how optimizing for different peak temperatures affects the results and demonstrates the use of the pressure drop constraint to limit the maximum flow rate.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ROSE Compiler Framework

The purpose of the ROSE Complier Framework Is to automate source code porting, source and binary code analysis, and source code translations such as platform optimization, binary code analysis, Identification of source code and binary code vulnerablllttes.

Quinlan, Dan↗

Sensitivity Analysis, Reduced-order Modeling, and Optimization of a Gas-Cooled Pebble Bed Reactor using Equilibrium-Core and DLOFC Performance

This work presents and applies a workflow for performing design optimization on gas-cooled pebble-bed reactors. Based on previous research, a representative equilibrium core of a pebble-bed reactor and a depressurized loss-of-forced-cooling model are created. These applications are built using the Multiphysics Object-Oriented Simulation Environment (MOOSE), specifically utilizing Griffin, Pronghorn, and Bison. After defining design-related parameters and quantities of interest regarding reactor safety and efficiency, this multiphysics model is sampled using the MOOSE stochastic tools module. The result is a comprehensive dataset of configurations, enabling sensitivity analysis and the generation of reduced-order models. Subsequently, the dataset and reduced-order models are employed in an optimization study aimed at maximizing fuel utilization while adhering to safety and operational constraints. The optimization process leads to an improvement of fuel utilization by approximately 10\%, compared to engineering-judgment-based nominal conditions.

97 - MATHEMATICS AND COMPUTING↗

A CONSISTENT RETRIEVAL ANALYSIS OF 10 HOT JUPITERS OBSERVED IN TRANSMISSION

We present a consistent optimal estimation retrieval analysis of 10 hot Jupiter exoplanets, each with transmission spectral data spanning the visible to near-infrared wavelength range. Using the NEMESIS radiative transfer and retrieval tool, we calculate a range of possible atmospheric states for WASP-6b, WASP-12b, WASP-17b, WASP-19b, WASP-31b, WASP-39b, HD 189733b, HD 209458b, HAT-P-1b, and HAT-P-12b. We find that the spectra of all 10 planets are consistent with the presence of some atmospheric aerosol; WASP-6b, WASP-12b, WASP-17b, WASP-19b, HD 189733b, and HAT-P-12b are all fit best by Rayleigh scattering aerosols, whereas WASP-31b, WASP-39b and HD 209458b are better represented by a gray cloud model. HAT-P-1b has solutions that fall into both categories. WASP-6b, HAT-P-12b, HD 189733b, and WASP-12b must have aerosol extending to low atmospheric pressures (below 0.1 mbar). In general, planets with equilibrium temperatures between 1300 and 1700 K are best represented by deeper, gray cloud layers, whereas cooler or hotter planets are better fit using high Rayleigh scattering aerosol. We find little evidence for the presence of molecular absorbers other than H{sub 2}O. Retrieval methods can provide a consistent picture across a range of hot Jupiter atmospheres with existing data, and will be a powerful tool for the interpretation of James Webb Space Telescope observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling perennial bioenergy crops in the E3SM land model (ELMv2)

Perennial bioenergy crops are increasingly important for the production of ethanol and other renewable fuels, and as part of an agricultural system that alters the climate through its impact on biogeophysical and biogeochemical properties of the terrestrial ecosystem. Few earth system models (ESMs) represent such crops, however. In this study, we expand the Energy Exascale Earth System Model (E3SM) Land Model (ELMv2) to include perennial bioenergy crops with a high potential for mitigating climate change. We focus on high-productivity miscanthus and switchgrass, estimating various parameters associated with their different growth stages and performing a global sensitivity analysis to identify and optimize these parameters. The sensitivity analysis identifies five parameters associated with phenology, carbon/nitrogen allocation, stomatal conductance, and maintenance respiration as the most sensitive parameters for carbon and energy fluxes. We calibrated and validated the model against observations and found that the model closely captures the observed seasonality and the magnitude of carbon fluxes. The validated model represents the latent heat flux fairly well, but sensible heat flux for miscanthus is not well captured. Finally, we validated the model against observed leaf area index (LAI) and harvest amount and found modeled LAI captured observed seasonality , although the model underestimates LAI and harvest amount. This work provides a foundation for future ESM analyses of the interactions between perennial bioenergy crops and carbon, water, and energy dynamics in the larger earth system, and sets the stage for studying the impact of future biofuel expansion on climate and terrestrial systems.

09 BIOMASS FUELS↗