Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Theory-guided design of duplex-phase multi-principal-element alloys

Density-functional theory (DFT) is used to identify phase-equilibria in multi-principal-element and high-entropy alloys (MPEAs/HEAs), including duplex-phase and eutectic microstructures. Here, a combination of composition-dependent formation energy and electronic-structure-based ordering parameters were used to identify a transition from FCC to BCC favoring mixtures, and these predictions experimentally validated in the Al-Co-Cr-Cu-Fe-Ni system. A sharp crossover in lattice structure and dual-phase stability as a function of composition were predicted via DFT and validated experimentally. The impact of solidification kinetics and thermodynamic stability was explored experimentally using a range of techniques, from slow (castings) to rapid (laser remelting), which showed a decoupling of phase fraction from thermal history, i.e., phase fraction was found to be solidification rate-independent, enabling tuning of a multi-modal cell and grain size ranging from nanoscale through macroscale. Strength and ductility tradeoffs for select processing parameters were investigated via uniaxial tension and small-punch testing on specimens manufactured via powder-based additive manufacturing (directed-energy deposition). This work establishes a pathway for design and optimization of next-generation multiphase superalloys via tailoring of structural and chemical ordering in concentrated solid solutions.

36 MATERIALS SCIENCE↗

Amplitude- and frequency-dependent activation of layer II/III neurons by intracortical microstimulation

Intracortical microstimulation (ICMS) has been used for the development of brain machine interfaces. However, further understanding about the spatiotemporal responses of neurons to different electrical stimulation parameters is necessary to inform the design of optimal therapies. In this study, we employed in vivo electrophysiological recording, two-photon calcium imaging, and electric field simulation to evaluate the acute effect of ICMS on layer II/III neurons. Our results show that stimulation frequency non-linearly modulates neuronal responses, whereas the magnitude of responses is linearly correlated to the electric field strength and stimulation amplitude before reaching a steady state. Temporal dynamics of neurons’ responses depends more on stimulation frequency and their distance to the stimulation electrode. In addition, amplitude-dependent post-stimulation suppression was observed within ~500 μm of the stimulation electrode, as evidenced by both calcium imaging and local field potentials. These findings provide insights for selecting stimulation parameters to achieve desirable spatiotemporal specificity of ICMS.

59 BASIC BIOLOGICAL SCIENCES↗

On the Use of the Beta Distribution in Probabilistic Resource Assessments

The triangular distribution is a popular choice when it comes to modeling bounded continuous random variables. Its wide acceptance derives mostly from its simple analytic properties and the ease with which modelers can specify its three parameters through the extremes and the mode. On the negative side, hardly any real process follows a triangular distribution, which from the outset puts at a disadvantage any model employing triangular distributions. At a time when numerical techniques such as the Monte Carlo method are displacing analytic approaches in stochastic resource assessments, easy specification remains the most attractive characteristic of the triangular distribution. The beta distribution is another continuous distribution defined within a finite interval offering wider flexibility in style of variation, thus allowing consideration of models in which the random variables closely follow the observed or expected styles of variation. Despite its more complex definition, generation of values following a beta distribution is as straightforward as generating values following a triangular distribution, leaving the selection of parameters as the main impediment to practically considering beta distributions. This contribution intends to promote the acceptance of the beta distribution by explaining its properties and offering several suggestions to facilitate the specification of its two shape parameters. In general, given the same distributional parameters, use of the beta distributions in stochastic modeling may yield significantly different results, yet better estimates, than the triangular distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Probabilistic Design Method Applied to Smart Composite Structures

A probabilistic design method is described and demonstrated using a smart composite wing. Probabilistic structural design incorporates naturally occurring uncertainties including those in constituent (fiber/matrix) material properties, fabrication variables, structure geometry and control-related parameters. Probabilistic sensitivity factors are computed to identify those parameters that have a great influence on a specific structural reliability. Two performance criteria are used to demonstrate this design methodology. The first criterion requires that the actuated angle at the wing tip be bounded by upper and lower limits at a specified reliability. The second criterion requires that the probability of ply damage due to random impact load be smaller than an assigned value. When the relationship between reliability improvement and the sensitivity factors is assessed, the results show that a reduction in the scatter of the random variable with the largest sensitivity factor (absolute value) provides the lowest failure probability. An increase in the mean of the random variable with a negative sensitivity factor will reduce the failure probability. Therefore, the design can be improved by controlling or selecting distribution parameters associated with random variables. This can be implemented during the manufacturing process to obtain maximum benefit with minimum alterations.

Shiao, Michael C.↗

Hydrogen storage adsorbent systems acceptability envelope

A methodology was developed here to determine the range of coupled material parameters and operating conditions that allow an adsorbent based hydrogen storage system to meet performance targets. The range of acceptable parameters forms a multi-dimensional volume, or envelope. For this reason, the methodology is referred to as the Adsorbent Acceptability Envelope. The model evaluates the performance of the overall storage tank, comprised of the adsorbent material, the heat transfer system and the pressure vessel. Two cases were analyzed, both based on the flow-through cooling approach providing the cooling power required to charge hydrogen, with results presented and discussed. The first application (the forward problem) analyzed the gravimetric and volumetric performance of MOF-5 ® based hydrogen storage beds, under various operating conditions. Results demonstrated that the system can reach a gravimetric capacity of approximately 4 wt% and volumetric capacity of about 20 g/L within 200 s during the absorption process. The second application (the inverse problem) identified the range of selected material parameters, required to meet the U.S. Department of Energy targets for gravimetric and volumetric capacity. Results showed that the most important parameters are the maximum capacity and the density of the material. Adsorbents having a density on the order of twice that of nominal powder form MOF-5 ® can meet the 2020 DOE targets (i.e. system gravimetric capacity of 0.045 kg H2 /kg System and system volumetric capacity of 0.030 kg H2 /L System ). A density of about 3–4.5 times the nominal value is required to meet the DOE 2025 targets (i.e. system gravimetric capacity of 0.055 kg H2 /kg System and system volumetric capacity of 0.040 kg H2 /L System ). Likewise, a material with a maximum adsorption capacity approximately equal to three times that of nominal MOF-5 ® can meet the 2020 DOE targets, while a maximum capacity about 4.5 times the nominal value is required to meet the 2025 DOE targets.

08 HYDROGEN↗

SU-F-T-344: Commissioning Constant Dose Rate VMAT in the Raystation Treatment Planning System for a Varian Clinac IX

Purpose: To demonstrate the commissioning of constant dose rate volumetric modulated arc therapy (VMAT) in the Raystation treatment planning system for a Varian Clinac iX with Exact couch. Methods: Constant dose rate (CDR) VMAT is an option in the Raystation treatment planning system, enabling VMAT delivery on Varian linacs without a RapidArc upgrade. Raystation 4.7 was used to commission CDR-VMAT for a Varian Clinac iX. Raystation arc model parameters were selected to match machine deliverability characteristics. A Varian Exact couch model was added to Raystation 4.7 and commissioned for use in VMAT optimization. CDR-VMAT commissioning checks were performed on the linac, including patient-specific QA measurements for 10 test patients using both the ArcCHECK from Sun Nuclear Corporation and COMPASS from IBA Dosimetry. Multi-criteria optimization (MCO) in Raystation was used for CDR-VMAT planning. Results: Raystation 4.7 generated clinically acceptable and deliverable CDR-VMAT plans for the Varian Clinac. VMAT plans were optimized including a model of the Exact couch with both rails in the out positions. CDR-VMAT plans generated with MCO in Raystation were dosimetrically comparable to Raystation MCO-generated IMRT plans. Patient-specific QA measurements with the ArcCHECK on the couch showed good agreement with the treatment planning system prediction. Patient-specific, structure-specific, multi-statistical parameter 3D QA measurements with gantry-mounted COMPASS also showed good agreement. Conclusion: Constant dose rate VMAT was successfully modeled in Raystation 4.7 for a Varian Clinac iX, and Raystation’s multicriteria optimization generated constant dose rate VMAT plans which were deliverable and dosimetrically comparable to IMRT plans.

60 APPLIED LIFE SCIENCES↗

Recursive Branching Simulated Annealing Algorithm

This innovation is a variation of a simulated-annealing optimization algorithm that uses a recursive-branching structure to parallelize the search of a parameter space for the globally optimal solution to an objective. The algorithm has been demonstrated to be more effective at searching a parameter space than traditional simulated-annealing methods for a particular problem of interest, and it can readily be applied to a wide variety of optimization problems, including those with a parameter space having both discrete-value parameters (combinatorial) and continuous-variable parameters. It can take the place of a conventional simulated- annealing, Monte-Carlo, or random- walk algorithm. In a conventional simulated-annealing (SA) algorithm, a starting configuration is randomly selected within the parameter space. The algorithm randomly selects another configuration from the parameter space and evaluates the objective function for that configuration. If the objective function value is better than the previous value, the new configuration is adopted as the new point of interest in the parameter space. If the objective function value is worse than the previous value, the new configuration may be adopted, with a probability determined by a temperature parameter, used in analogy to annealing in metals. As the optimization continues, the region of the parameter space from which new configurations can be selected shrinks, and in conjunction with lowering the annealing temperature (and thus lowering the probability for adopting configurations in parameter space with worse objective functions), the algorithm can converge on the globally optimal configuration. The Recursive Branching Simulated Annealing (RBSA) algorithm shares some features with the SA algorithm, notably including the basic principles that a starting configuration is randomly selected from within the parameter space, the algorithm tests other configurations with the goal of finding the globally optimal solution, and the region from which new configurations can be selected shrinks as the search continues. The key difference between these algorithms is that in the SA algorithm, a single path, or trajectory, is taken in parameter space, from the starting point to the globally optimal solution, while in the RBSA algorithm, many trajectories are taken; by exploring multiple regions of the parameter space simultaneously, the algorithm has been shown to converge on the globally optimal solution about an order of magnitude faster than when using conventional algorithms. Novel features of the RBSA algorithm include: 1. More efficient searching of the parameter space due to the branching structure, in which multiple random configurations are generated and multiple promising regions of the parameter space are explored; 2. The implementation of a trust region for each parameter in the parameter space, which provides a natural way of enforcing upper- and lower-bound constraints on the parameters; and 3. The optional use of a constrained gradient- search optimization, performed on the continuous variables around each branch s configuration in parameter space to improve search efficiency by allowing for fast fine-tuning of the continuous variables within the trust region at that configuration point.

Bolcar, Matthew↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Annual report of groundwater monitoring at Centralia, Kansas, in 2010.

In September 2005, periodic sampling of groundwater was initiated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Centralia, Kansas. The sampling at Centralia is performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE). The objective is to monitor levels of carbon tetrachloride contamination identified in the groundwater at Centralia (Argonne 2003, 2004, 2005a). Under the KDHE-approved monitoring plan (Argonne 2005b), the groundwater was sampled twice yearly from September 2005 until September 2007 for analyses for volatile organic compounds (VOCs), as well as measurement of selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation processes (reductive dechlorination) in the subsurface environment (Argonne 2006, 2007a, 2008a). The results from the two-year sampling program demonstrated the presence of carbon tetrachloride contamination at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5 {micro}g/L for this compound, in a localized groundwater plume that has shown little movement. The relative concentrations of chloroform, the primary degradation product of carbon tetrachloride, suggested that some degree of reductive dechlorination or natural biodegradation was talking place in situ at the former CCC/USDA facility on a localized scale. The CCC/USDA subsequently developed an Interim Measure Conceptual Design (Argonne 2007b), proposing a pilot test of the Adventus EHC technology for in situ chemical reduction (ISCR). The proposed interim measure (IM) was approved by the KDHE in November 2007 (KDHE 2007). Implementation of the pilot test occurred in November-December 2007. The objective was to create highly reducing conditions that would enhance both chemical and biological reductive dechlorination in the injection test area (Argonne 2009a). The KDHE (2008a) requested that sitewide monitoring continue until a final remedy is selected (as part of a Corrective Action Study [CAS] evaluation) and implemented. In response to this request, the established sampling across the site and additional sampling in the IM pilot test area continued in 2008 (Argonne 2008b, 2009a,b). On the basis of results of the 2005-2008 sitewide monitoring and the 2008 IM pilot test monitoring, the CCC/USDA recommended a revised sampling program for both the wider site and the IM pilot test area (Section 4.2 in Argonne 2009b). The elements of this interim monitoring plan are as follows: (1) Annual sampling of twelve monitoring points across the site (Figure 1.1) and five outlying IM pilot test monitoring points (PMP4, PMP5, PMP6, PMP7, PMP9; Figure 1.2); and (2) Twice yearly sampling of five IM pilot test monitoring points inside the injection area (PMP1-PMP3, PMP8, MW02; Figure 1.2). With the approval of the KDHE (2009), the initial groundwater sampling for VOCs and geochemical analyses under the interim monitoring plan outlined above was conducted in 2009 (Argonne 2010). The present report documents the findings of the 2010 monitoring events, conducted on April 5 and September 19-21, 2010.

54 ENVIRONMENTAL SCIENCES↗

Transient natural convection heat and mass transfer in crystal growth

A numerical analysis of transient combined heat and mass transfer across a rectangular cavity is performed by a numerical method based on the SIMPLE algorithm. The physical parameters are selected to represent a range of possible crystal growth in solutions. Numerical results are compared with available experimental data to confirm the accuracy of the results. Good qualitative agreements are obtained for the average mass transfer rate across the cavity. Also, qualitative agreements are observed for the global development of thermal and solute fields. It is found that the thermal and solute fields become highly oscillatory when the thermal and solute Grashof numbers are large. Oscillations are probably caused by a number of different instability mechanisms. By reducing the gravity some of these instabilities were made to disappear at the lower Grashof numbers. Transient temperature and solute distribution near the crystal growing surface are highly non-uniform at the higher Grashof numbers. These non-uniformities are less severe in the reduced gravity environments but still exist. The effects of convection on the rate of average mass transfer are more than one order of magnitude higher than those of conduction in the range of Grashof numbers studied. Dependency of mass transfer rate on the Grashof number indicates that the convection effects many not be negligible even in the microgravity environments for the range of parameters investigated.

Han, Samuel S.↗

Model Assisted Probability of Detection for NASA Space Missions

Model assisted probability of detection (MAPOD) uses data from simulations to improve a traditional probability of detection (POD) study. This could include extending the parameter space to reduce uncertainty or substituting experimental data with simulated data to reduce the time and cost of a POD study. In the past MAPOD was difficult due to limited computational resources, but recent innovations in simulation tools and high-performance computing have made this type of high-degree-of-freedom modelling possible, and complex structures have made it necessary. This presentation will summarize the work done by the computational nondestructive evaluation (CNDE) group at NASA Langley Research Center (LaRC) to complete a MAPOD study for phased array ultrasound testing (PAUT) of a friction stir welding (FSW) method to be used on Space Launch System (SLS) structures. The three critical needs for a MAPOD study are a validated and verified model of the inspection technique for the structure being inspected, some experimental POD data, and an uncertainty model for both the model and the experimental data. PAUT was simulated using Extende CIVA’s UT module. The model was validated using laboratory inspection data from NASA Marshall Space Flight Center (MSFC) for a Hit/Miss POD for FSW in 2219-T87 aluminum panels representative of those used in the SLS. This model was then used to simulate flaw sizes that were originally omitted from the original POD study. The results of this new MAPOD study will be presented along with a discussion of the methods and processes used to analyze the original data, selected simulation parameters, and development of the uncertainty model used for the statistical analysis. The goal of this effort is not just to improve the POD study but to demonstrate the value of MAPOD and provide a roadmap for application of MAPOD on future projects.

Elizabeth Gregory↗

Model Assisted Probability of Detection for NASA Space Missions

Model assisted probability of detection (MAPOD) uses data from simulations to improve a traditional probability of detection (POD) study. This could include extending the parameter space to reduce uncertainty or substituting experimental data with simulated data to reduce the time and cost of a POD study. In the past MAPOD was difficult due to limited computational resources, but recent innovations in simulation tools and high-performance computing have made this type of high-degree-of-freedom modeling possible, and complex structures have made it necessary. This presentation will summarize the work done by the computational nondestructive evaluation (CNDE) specialists within the Nondestructive Evaluation Sciences branch at NASA Langley Research Center (LaRC) to complete a MAPOD study for phased array ultrasound testing (PAUT) of a friction stir welding (FSW) method to be used on Space Launch System (SLS) structures. The three critical needs for a MAPOD study are a validated and verified model of the inspection technique for the structure being inspected, some experimental POD data, and an uncertainty model for both the model and the experimental data. PAUT was simulated using Extende CIVA’s UT module. The model was validated using laboratory inspection data from NASA Marshall Space Flight Center (MSFC) for a Hit/Miss POD for FSW in 2219-T87 aluminum panels representative of those used in the SLS. This model was then used to simulate flaw sizes that were originally omitted from the original POD study. The results of this new MAPOD study will be presented along with a discussion of the methods and processes used to analyze the original data, selected simulation parameters, and development of the uncertainty model used for the statistical analysis. The goal of this effort is not just to improve the POD study but to demonstrate the value of MAPOD and provide a roadmap for application of MAPOD on future projects.

Elizabeth Gregory↗

Skeletal Phenotype of Transgenic Mice Expressing the Beta1 Integrin Cytoplasmic Tail In Osteoblasts

To define the physiologic role of beta1 integrin in bone formation and mechanical loading, transgenic mice were generated by expressing the cytoplasmic tall and transmembrane domain of Beta1 integrin under the control of the osteocalcin promoter. In cultured cells, this truncated fragment of Beta1 can act as a dominant negative. Previously, the matrix of calvariae was shown to be abnormal in transgenic (TG) compared to wildtype (WT) mice. In this study, we analyzed appendicular bone in TG and WT, male and female mice at 14, 35, 63, 90 and 365 days old (n=8-12/gp). To assess beta1 integrin function in mechanical loading, a pilot study using hindlimb unloading by tail suspension was performed. 35d old TG and WT females were hindlimb unloaded for 4 wks (n=3-5). Body mass, bone mineral content, histomorphometric (distal femur) and biomechanical parameters were analyzed. Statistical significance (P less than.05) was defined by ANOVA using the Tukey-Kramer post-hoc test. We confirmed transgene expression by immunoprecipitating then immunoblotting bone lysates using an antibody against the beta1 tail. Body masses of TG mice at 63, 90 and 365d old were greater (16-25%) than WT. Some TG female mice at 365d appeared obese; mean abdominal fat mass was 415% greater in TG than WT mice. Tibiae were longer (5-7%) in TG than WT mice at 63 and 90d. Tibial mineral mass of 35d males was 7% lower in TG than WT mice, but at 63d was 21% higher. The % osteoblast surface in 35d TG mice was 20% higher than WT, and at 63d was 17% lower, while % osteoclast surface did not differ. In 365d mice, cancellous bone volume (125%) and endocortical mineral apposition rate (40%) were greater in TG than WT males but not females. In WT mice, hindlimb unloading caused a reduction in mineral mass of tibiae (-20%) and lumbar vertebrae (-22%) relative to normally loaded controls. Surprisingly, hindlimb unloading also caused a relative reduction (-13%) in humerus mass. The effects of hindlimb unloading on tibia and humerus mass were less obvious in TG than in WT mice. Since hindlimb unloading caused skeletal changes in both loaded and unloaded bones, systemic changes may contribute to bone responses observed using this animal model. In conclusion, transgene expression resulted in marked metabolic changes during growth and in the aged female. Our results demonstrate that expression of the Beta1 integrin cytoplasmic tail in vivo causes gender- and age-specific changes in select morphometric parameters, bone length, and bone mass.

Globus, R. K.↗

CORPSE model with litter decomposition parameters derived from the LIDET dataset

This is a version of the CORPSE model (Carbon, Organisms, Rhizosphere and Protection in the Soil Environment, Sulman et al. 2014) that uses litter decomposition parameters derived from a modified Monte Carlo simulation using the LIDET litter decomposition dataset (Long-term Intersite Decomposition Experiment Team, Harmon 2013). The code also includes the Baseline parameters, and the eight other best parameter sets identified in a modified Monte Carlo simulation. Related publication:Juice, S.M., Ridgeway, J.R., Hartman, M.D., Parton, W.J., Berardi, D.M., Sulman, B.N., Allen, K.E., & Brzostek, E.R. Reparameterizing litter decomposition using a simplified Monte Carlo method improves litter decay simulated by a microbial model and alters bioenergy soil carbon estimates. Description of files:The folder "Input Files" contains one folder for each LIDET site with data necessary to run the model. Note that "(site)" in the filenames below indicates where the LIDET site code appears (see Table 1 for site codes). Data streams include: CORPSE_full_spinup_litter.csv, CORPSE_full_spinup_rhizo.csv, CORPSE_full_spinup_bulk.csv, litterbag_init_100g_6spp.csv: initial C and N (kg C or N/m2) pool values for each soil layer, the litterbag_init_100_6spp.csv file is for the litterbag layer and is the same file for all sites. All initial C and N files have the same columns (Column - Description - Units) uFastC - Unprotected fast decomposing carbon - kg carbon/m2 uSlowC - Unprotected slow decomposing carbon - kg carbon/m2 uNecroC - Unprotected necromass carbon - kg carbon/m2 pFastC - Protected fast decomposing carbon - kg carbon/m2 pSlowC - Protected slow decomposing carbon - kg carbon/m2 pNecroC - Protected necromass carbon - kg carbon/m2 livingMicrobeC - Carbon in living microbial biomass - kg carbon/m2 uFastN - Unprotected fast decomposing nitrogen - kg nitrogen/m2 uSlowN - Unprotected slow decomposing nitrogen - kg nitrogen/m2 uNecroN - Unprotected necromass nitrogen - kg nitrogen/m2 pFastN - Protected fast decomposing nitrogen - kg nitrogen/m2 pSlowN - Protected slow decomposing nitrogen - kg nitrogen/m2 pNecroN - Protected necromass nitrogen - kg nitrogen/m2 inorganicN - Inorganic nitrogen - kg nitrogen/m2 CO2 - Carbon in carbon dioxide - kg carbon/m2 livingMicrobeN - Nitrogen in living microbial biomass - kg nitrogen/m2 soilT (site) DOY274start.csv: Average daily soil temperature (oC) interpolated from previously calculated monthly values used in DayCent LIDET simulations (Bonan et al., 2013). soilT (site) DOY274start.csv: Average daily soil volumetric water content (VWC) scalar interpolated from previously calculated monthly values used in DayCent LIDET simulations (Bonan et al., 2013). litter production.csv: Average daily litter production values for each site, data sources listed in Table S3 of related publication. litter (site) CN.csv: C:N ratio for each species from LIDET dataset (Table 2, Harmon 2013). (site).csv: Table indicating number of observations for each species decomposed at each site. Instructions: Save the model code ("CORPSE_LIDET.R") and "Input Files" folder in the same folder. Also make a folder for the model output (e.g., "results_Baseline") in the same folder. Set the working directory (setwd) in the model code to the folder with the files saved in step #1. Select the parameter set to use for the litter and litterbag compartments, comment out all other parameter sets. Run code. Output will be saved in the folder made in step 1. Output destination can be changed as necessary in code section called "Running the model." Table 1 LIDET sites and site codes used in model files. Site Code - Site AND - H.J. Andrews Experimental Forest BNZ - Bonanza Creek Experimental Forest BSF - Blodgett Research Forest CDR - Cedar Creek Natural History Area CPR - Central Plains Experimental Range HBR - Hubbard Brook Experimental Forest HFR - Harvard Forest JUN - Juneau KBS - Kellogg Biological Station KNZ - Konza Prairie Research Natural Area NWT - Niwot Ridge/Green Lakes Valley OLY - Olympic National Park OLY Conifer forest SEV - Sevilleta National Wildlife Refuge SMR - Santa Margarita Ecological Reserve UFL - University of Florida VCR - Virginia Coast Reserve Table 2 LIDET species and species codes used in model files (6 common species). Species - Species Code Sugar maple (Acer saccharum) - ACSA Drypetes (Drypetes glauca) - DRGL Red pine (Pinus resinosa) - PIRE Chestnut oak (Quercus prinus) - QUPR Western redcedar (Thuja plicata) - THPL Wheat (Triticum aestivum) - TRAE References:Bonan, G. B., Hartman, M. D., Parton, W. J., & Wieder, W. R. (2013). Evaluating litter decomposition in earth system models with long-term litterbag experiments: an example using the Community Land Model version 4 (CLM4). Global Change Biology, 19(3), 957-974. https://doi.org/https://doi.org/10.1111/gcb.12031 Harmon, M. (2013). LTER Intersite Fine Litter Decomposition Experiment (LIDET), 1990 to 2002. Long-Term Ecological Research. Forest Science Data Bank, Corvallis, OR. [Data set]. Accessed http://andlter.forestry.oregonstate.edu/data/abstract.aspx?dbcode=TD023. https://doi.org/10.6073/pasta/f35f56bea52d78b6a1ecf1952b4889c5. Sulman, B. N., Phillips, R. P., Oishi, A. C., Shevliakova, E., & Pacala, S. W. (2014). Microbe-driven turnover offsets mineral-mediated storage of soil carbon under elevated CO2. Nature Climate Change, 4, 1099 - 1102. https://doi.org/10.1038/nclimate2436

Juice, Stephanie↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

Image-Based Monitoring of Magnetic Resonance-Guided Thermoablative Therapies for Liver Tumors

Minimally invasive treatment options for liver tumor therapy have been increasingly used during the last decade because their benefit has been proven for primary and inoperable secondary liver tumors. Among these, radiofrequency ablation has gained widespread consideration. Optimal image-guidance offers precise anatomical information, helps to position interventional devices, and allows for differentiation between already-treated and remaining tumor tissue. Patient safety and complete ablation of the entire tumor are the overriding objectives of tumor ablation. These may be achieved most elegantly with magnetic resonance (MR)-guided therapy, where monitoring can be performed based on precise soft-tissue imaging and additional components, such as diffusion-weighted imaging and temperature mapping. New MR scanner types and newly developed sequence techniques have enabled MR-guided intervention to move beyond the experimental phase. This article reviews the current role of MR imaging in guiding radiofrequency ablation. Signal characteristics of primary and secondary liver tumors are identified, and signal alteration during therapy is described. Diffusion-weighted imaging (DWI) and temperature mapping as special components of MR therapy monitoring are introduced. Practical information concerning coils, sequence selection, and parameters, as well as sequence gating, is given. In addition, sources of artifacts are identified and techniques to decrease them are introduced, and the characteristic signs of residual tumor in T1-, T2-, and DWI are described. We hope to enable the reader to choose MR sequences that allow optimal therapy monitoring depending on the initial signal characteristics of the tumor as well as its size and location in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Selection of the Informative Input Parameters for the Inverse Neural-Network Models of Observed Systems

We consider the problem of determination of the parameters of a measurement grid, which guarantees the exactness and stability of the solution of the inverse problem. The choice of the points of measurements is performed under the assumption of existence of the most informative data. We present the results illustrating the influence of the number of measurement points on the data of reconstruction of the parameters of the load function acting upon the cylindrical shell in a strip located along the length of the shell.

97 MATHEMATICS AND COMPUTING↗

Image encryption and watermarking combined dynamic chaotic hopping pattern with double random phase encoding DRPE

In modern civilization information, security is a crucial problem. Image encryption and watermarking can effectively protect information from unauthorized access. This paper introduces a new vigorous symmetric optical image encryption and watermarking technique. This technique depends on a novel dynamic delay chaotic hopping pattern (DDCHP) combined with double random phase encoding (DRPE). To get a robust watermark image, the plain image is first watermarked with a binary secret message using a new chaotic hopping pattern (CHP) and then encrypted using a DRPE system that is controlled by double random independent keys generated with double DDCHP. In this symmetric cryptosystem, three different chaotic maps are used to enlarge the key space of the proposed cryptosystem against brute-force attack and overcome the linearity and vulnerable of the classical DRPE. The system keys are hypersensitive and their initial parameters are selected carefully. Security scrutiny proves the efficiency of the suggested cryptosystem. Therefore, the obtained simulation results prove that the cryptosystem is robust enough against the known attacks, such as statistical attack (uniform histograms of different encrypted images, correlation coefficients between the plain and the encrypted image is as low as 5.46 × 10{sup −6}), differential attack (99.99% NPCR and 38.6% UACI), brute force attack (large enough key space), and entropy attack. Moreover, the robustness of the watermark (secret message) is proved due to the solidity of CHP. The proposed approach can be used in different implementations like secure military communications, e-finance, e-healthcare, authenticated multimedia broadcasting, etc.

97 MATHEMATICS AND COMPUTING↗