Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Unsupervised Azimuth Estimation of Solar Arrays in Low-Resolution Satellite Imagery through Semantic Segmentation and Hough Transform

This paper explains the use of a convolutional neural network (CNN) to segment solar panels in a satellite image containing solar arrays, and extract associated metadata from the arrays. A novel unsupervised technique is introduced to estimate the azimuth of each individual solar panel from the predicted mask of the convolutional neural network. This pipeline was developed with the aim of extracting necessary metadata for a solar installation, using only a set of latitude–longitude coordinates. Azimuth prediction results for 669 individual solar installations associated with 387 sites located across the United States are provided. A mean average error and median average error of 21.65 degrees and 1.0 degrees were obtained, respectively, when predicting the azimuth of the solar fleet data set, with about 80% of the results within an error of zero degrees of the ground truth azimuth value and about 85% within an error of 25 degrees. The predicted azimuth was then used to estimate the energy conversion of the solar arrays. Results show a 90.9 and 90.6 R-squared value for estimating alternating current (AC) and direct current (DC) energy, respectively, and a mean absolute percentage error (MAPE) of 1.70% in estimating the alternating current (AC) energy using the fully automated algorithm.

14 SOLAR ENERGY↗

Reconsidering tympanal-acoustic interactions leads to an improved model of auditory acuity in a parasitoid fly

Although most binaural organisms locate sound sources using neurological structures to amplify the sounds they hear, some animals use mechanically coupled hearing organs instead. One of these animals, the parasitoid fly Ormia ochracea (O. ochracea), has astoundingly accurate sound localization abilities. It can locate objects in the azimuthal plane with a precision of 2°, equal to that of humans, despite an intertympanal distance of only 0.5 mm, which is less than 1/100th of the wavelength of the sound emitted by the crickets that it parasitizes. O. ochracea accomplishes this feat via mechanically coupled tympana that interact with incoming acoustic pressure waves to amplify differences in the signals received at the two ears. In 1995, Miles et al developed a model of hearing mechanics in O. ochracea that represents the tympana as flat, front-facing prosternal membranes, though they lie on a convex surface at an angle from the flies' frontal and transverse planes. The model works well for incoming sound angles less than ±30° but suffers from reduced accuracy (up to 60% error) at higher angles compared to response data acquired from O. ochracea specimens. Despite this limitation, it has been the basis for bio-inspired microphone designs for decades. Here, we present critical improvements to this classic hearing model based on information from three-dimensional reconstructions of O. ochracea's tympanal organ. We identified the orientation of the tympana with respect to a frontal plane and the azimuthal angle segment between the tympana as morphological features essential to the flies' auditory acuity, and hypothesized a differentiated mechanical response to incoming sound on the ipsi- and contralateral sides that depend on these features. We incorporated spatially-varying model coefficients representing this asymmetric response, making a new quasi-two-dimensional (q2D) model. The q2D model has high accuracy (average errors of under 10%) for all incoming sound angles. This improved biomechanical model may inform the design of new microscale directional microphones and other small-scale acoustic sensor systems.

36 MATERIALS SCIENCE↗

Anti-Phase Vortex Reduction Control for Rotor Noise Suppression

An investigation is conducted in 2019 under the NASA Ames Center Innovation Funds (CIF) project entitled “Anti-Phase Vortex Reduction Control for Rotor Noise Suppression“ to experimentally validate an anti-phase rotor noise suppression concept. The first objective of the investigation is to conduct computational fluid dynamics (CFD) simulations to investigate the noise characteristics of several anti-phase rotor designs. The second objective is to conduct a series of acoustic tests of anti-phase rotors in an anechoic chamber at Pennsylvania State University (PSU) to evaluate the merit of the anti-phase rotor concept. The CFD investigation seeks to optimize the anti-phase alternating trailing edge patterns for rotor noise suppression. The design objective is to maximize the noise reduction while maintaining the aerodynamic thrust. The investigation is performed using a three-dimensional (3D) Unsteady Reynolds-Averaged Navier-Stokes (URANS) commercial solver STAR-CCM+ together with the Ffowcs-Williams and Hawkings (FW-H) formula to obtain the aerodynamic thrust and far-field noise level. An acoustic study is conducted for 13 anti-phase design candidates based on a proprietary rotor design. The CAD geometry of the rotor is furnished by PSU. These design candidates include different alternating trailing edge (TE) waveforms, TE segment lengths, TE deflection amplitudes, and transition characteristics. The best design candidate among those explored is an anti-phase rotor that has a four-period TE waveform which results in a reduction in far-field noise level of 2.1 dB in the hover condition and a reduction of 1.1 dB in the forward flight condition at 9.7 m/s. A further acoustic study is conducted for a different rotor manufactured by APC. Five APC rotor design candidates are simulated. The best anti-phase design candidate for the APC rotor results in a reduction in far-field noise level of 4.0 dB in the hover condition. An in-phase design candidate is also studied. This in-phase design provides a noise reduction of 2.5 dB. A series of acoustic experiments in the PSU anechoic chamber have been conducted in July 2019 and October 2019. Both anti-phase and in-phase rotors fabricated for the left-hand and right-hand rotations are tested. In the hover condition, all the rotors do not provide sufficient evidence of improved acoustic performance. However, the experimental data in the hover condition are deemed to be inconclusive due to the flow recirculation in the anechoic chamber caused by the rotor downwash. In the forward flight condition at 9.7 m/s, the anti-phase right-hand rotor produces a noise reduction by as much as 6.5 dB in the frequency range of 2000-4000 Hz, while the in-phase right-hand rotor produces a noise reduction by as much as 5 dB in the same frequency range. Both the anti-phase and in-phase left hand rotors offer no evidence of noise reduction. The difference in the acoustic performance of the left-hand and right-hand rotors could be explained by the location of the microphone array which is placed to the left side of the rotors. This microphone array location could create a bias in the sound pressure level in favor of the right-hand rotor. Using the average noise reduction values, the anti-phase 4H rotor could offer a noise reduction by as much as 3.25 dB while the in-phase 4I rotor could produce up to a 2.5 dB noise reduction. Both the computational and experimental results have provided sufficient evidence to support the noise suppression capability of the proposed anti-phase rotor concepts.

Rotor noise↗

Targeted Endovascular Temporary Vessel Occlusion with a Reverse Thermosensitive Polymer for Near-Bloodless Partial Nephrectomy: Comparison to Standard Surgical Clamping Techniques

Purpose: To determine whether reversible blood flow interruption to a randomly chosen target region of the kidney may be achieved with the injection of a reverse thermoplastic polymer through an angiographic catheter, thereby facilitating partial nephrectomy without compromising blood flow to the remaining kidney or adding risks beyond those encountered by the use of hilar clamping. Methods: Fifteen pigs underwent partial nephrectomy after blood flow interruption by vascular cross-clamping or injection of polymer (Lumagel Trade-Mark-Sign ) into a segmental artery. Five animals were euthanized after surgery (three open and two laparoscopic resection, cross-clamping n = 2), and 10 (open resection, cross-clamping n = 4) were euthanized after 6 weeks' survival. Blood specimens were obtained periodically, and angiogram and necropsy were performed at 6 weeks. Results: Selective renal ischemia was achieved in all cases. Surgical resection time averaged 9 and 24.5 min in the open and laparoscopic groups, respectively. Estimated blood loss was negligible with the exception of one case where an accessory renal artery was originally overlooked. Reversal of the polymer to a liquid state was consistent angiographically and visually in all cases. Time to complete flow return averaged 7.4 and 2 min for polymer and clamping, respectively. Angiography at 6 weeks revealed no evidence of vascular injury. Laboratory data and necropsies revealed no differences between animals undergoing vascular clamping or polymer injection. Conclusion: Lumagel was as effective as vascular clamping in producing a near bloodless operative field for partial nephrectomy while maintaining flow to the uninvolved portion of the affected kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of U3Si2/Al dispersion fuel for high power research reactors

In order to investigate the irradiation performance of U3Si2/Al dispersion fuel at relatively aggressive reactor conditions, compared to how this fuel is typically used in a research or test reactor, post irradiation examination was performed on two fuel plates that were irradiated at ~270 W/cm2 average surface heat flux and to a maximum local burnup greater than 8 × 1021 fissions/cm3 in the Advanced Test Reactor as part of the RERTR-8 experiment. As part of the non-destructive examinations that were performed on both fuel plates, detailed thickness measurements using a high-fidelity measurement bench were performed on one fuel plate and a segment of the second fuel plate. This paper provides the first reported results of such high-resolution thickness measurements for U3Si2/Al dispersion fuel plates, containing primarily the U3Si2 fuel phase, irradiated at such power levels to high burnup. For destructive examination using optical metallography, samples were generated from both irradiated plates. Localized regions of high swelling (characteristic of internal blistering) were observed on the surface of both fuel plates, suggesting that the performance limits had been reached for each plate. Destructive examinations showed that the fuel particles that are primarily U3Si2, which become amorphous during irradiation, in both plates contained relatively large fission gas bubbles with evidence of fission gas bubble interconnection.

Wachs, Daniel M.↗

Superiority of Equivalent Uniform Dose (EUD)-Based Optimization for Breast and Chest Wall

We investigate whether IMRT optimization based on generalized equivalent uniform dose (gEUD) objectives for organs at risk (OAR) results in superior dosimetric outcomes when compared with multiple dose-volume (DV)-based objectives plans for patients with intact breast and postmastectomy chest wall (CW) cancer. Four separate IMRT plans were prepared for each of the breast and CW cases (10 patients). The first three plans used our standard in-house, physician-selected, DV objectives (phys-plan); gEUD-based objectives for the OARs (gEUD-plan); and multiple, 'very stringent,' DV objectives for each OAR and PTV (DV-plan), respectively. The fourth plan was only beam-fluence optimized (FO-plan), without segmentation, which used the same objectives as in the DV-plan. The latter plan was to be used as an 'optimum' benchmark without the effects of the segmentation for deliverability. Dosimetric quantities, such as V{sub 20Gy} for the ipsilateral lung and mean dose (D{sub mean}) for heart, contralateral breast, and contralateral lung were used to evaluate the results. For all patients in this study, we have seen that the gEUD-based plans allow greater sparing of the OARs while maintaining equivalent target coverage. The average ipsilateral lung V{sub 20Gy} reduced from 22 {+-} 4.4% for the FO-plan to 18 {+-} 3% for the gEUD-plan. All other dosimetric quantities shifted towards lower doses for the gEUD-plan. gEUD-based optimization can be used to search for plans of different DVHs with the same gEUDs. The use of gEUD allows selective optimization and reduction of the dose for each OAR and results in a truly individualized treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evidence for Quasi-Periodic X-ray Dips from an ULX: Implications for the Binary Motion and the Orbital Inclination

We report results from long-term X-ray (0.3-8.0 keY) monitoring of the ultraluminous X-ray source NGC 5408 X-1 with the Swift/X-Ray Telescope. Our primary results are: (1) the discovery of quasi-periodic dips in the X-ray intensity that recur on average every 243 days, (2) the detection of an energy-dependent (variability amplitude decreases with increasing energy), quasi-sinusoidal X-ray modulation with a period of 112.6 +/- 4 days the amplitude of which decreases during the second half of the light curve and (3) energy spectral evidence for an increase in photoelectric absorption during the last continuous segment of the data, possibly due to a change in the ionization state of the circumbinary material. We interpret the X-ray modulations in the context of binary motion in analogy to that seen in high-inclination low-mass X-ray binaries. If correct, this implies that NGC 5408 X-1 is in a binary with an orbital period of 243 +/- 23 days in contrast to the 115.5 day quasi-sinusoidal period previously reported. In addition, if the X-ray modulation is caused by vertically structured obscuring material in the accretion disk (similar to the phenomenon of dipping LMXBs), this would imply a high value for the inclination of the orbit. A comparison with estimates from accreting X-ray binaries suggests an inclination approx > 60 deg. We note that, in principle, a precessing accretion disk could also produce the observed X-ray modulations.

Pasham, Dheeraj R.↗

A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging

A fiber/solid-state hybrid seeded regenerative amplifier, capable of achieving high output energy with tunable pulse widths, has been developed for satellite laser ranging applications. The regenerative amplifier cavity uses a pair of Nd:YAG zigzag slabs oriented orthogonally to one another in order to make thermal lensing effects symmetrical and simplify optical correction schemes. The seed laser used is a fiber-coupled 1,064-nm narrowband (<0.02 nm) diode laser that is discretely driven in a new short-pulsed mode, enabling continuously tunable seed pulse widths in the 0.2-to-0.4-ns range. The amplifier gain unit consists of a pair of Brewster-cut 6-bounce zigzag Nd:YAG laser slabs, oriented 90deg relative to each other in the amplifier head. This arrangement creates a net-symmetrical thermal lens effect (an opposing singleaxis effect in each slab), and makes thermo-optical corrections simple by optimizing the curvature of the nearest cavity mirror. Each slab is pumped by a single 120-W, pulsed 808-nm laser diode array. In this configuration, the average pump beam distribution in the slabs had a 1-D Gaussian shape, which matches the estimated cavity mode size. A half-wave plate between the slabs reduces losses from Fresnel reflections due to the orthogonal slabs Brewster-cut end faces. Successful "temporal" seeding of the regenerative amplifier cavity results in a cavity Q-switch pulse envelope segmenting into shorter pulses, each having the width of the input seed, and having a uniform temporal separation corresponding to the cavity round-trip time of approx. =10 ns. The pulse energy is allowed to build on successive passes in the regenerative amplifier cavity until a maximum is reached, (when cavity gains and losses are equal), after which the pulse is electro- optically switched out on the next round trip The overall gain of the amplifier is approx. =82 dB (or a factor of 1.26 million). After directing the amplified output through a LBO frequency doubling crystal, approx. = 2.1 W of 532-nm output (>1 mJ) was measured. This corresponds to a nonlinear conversion efficiency of >60%. Furthermore, by pulse pumping this system, a single pulse per laser shot can be created for the SLR (satellite laser ranging) measurement, and this can be ejected into the instrument. This is operated at the precise frequency needed by the measurement, as opposed to commercial short-pulsed, mode-locked systems that need to operate in a continuous fashion, or CW (continuous wave), and create pulses at many MHz. Therefore, this design does not need to throw away or dump 99% of the laser energy to produce what is required; this system can be far smaller, more efficient, cheaper, and readily deployed in the field when packaged efficiently. Finally, by producing custom diode seed pulses electronically, two major advantages over commercial systems are realized: First, this pulse shape is customizable and not affected by the cavity length or gain of the amplifier cavity, and second, it can produce adjustable (selectable) pulse widths by simply adding multiple seed diodes and coupling each into commercial, low-cost fiber-optic combiners.

Coyle, Barry↗

Southern Hemisphere Additional Ozonesondes (SHADOZ) Ozone Climatology (2005-2009): Tropospheric and Tropical Tropopause Layer (TTL) Profiles with Comparisons to Omi-based Ozone Products

We present a regional and seasonal climatology of SHADOZ ozone profiles in the troposphere and tropical tropopause layer (TTL) based on measurements taken during the first five years of Aura, 2005-2009, when new stations joined the network at Hanoi, Vietnam; Hilo, Hawaii; Alajuela Heredia, Costa Rica; Cotonou, Benin. In all, 15 stations operated during that period. A west-to-east progression of decreasing convective influence and increasing pollution leads to distinct tropospheric ozone profiles in three regions: (1) western Pacific eastern Indian Ocean; (2) equatorial Americas (San Cristobal, Alajuela, Paramaribo); (3) Atlantic and Africa. Comparisons in total ozone column from soundings, the Ozone Monitoring Instrument (OMI, on Aura, 2004-) satellite and ground-based instrumentation are presented. Most stations show better agreement with OMI than they did for EPTOMS comparisons (1998-2004; Earth-ProbeTotal Ozone Mapping Spectrometer), partly due to a revised above-burst ozone climatology. Possible station biases in the stratospheric segment of the ozone measurement noted in the first 7 years of SHADOZ ozone profiles are re-examined. High stratospheric bias observed during the TOMS period appears to persist at one station. Comparisons of SHADOZ tropospheric ozone and the daily Trajectory-enhanced Tropospheric Ozone Residual (TTOR) product (based on OMIMLS) show that the satellite-derived column amount averages 25 low. Correlations between TTOR and the SHADOZ sondes are quite good (typical r2 0.5-0.8), however, which may account for why some published residual-based OMI products capture tropospheric interannual variability fairly realistically. On the other hand, no clear explanations emerge for why TTOR-sonde discrepancies vary over a wide range at most SHADOZ sites.

gravity waves↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Three-dimensional imaging of mitochondrial cristae complexity using cryo-soft X-ray tomography

Mitochondria are dynamic organelles that change morphology to adapt to cellular energetic demands under both physiological and stress conditions. Cardiomyopathies and neuronal disorders are associated with structure-related dysfunction in mitochondria, but three-dimensional characterizations of the organelles are still lacking. In this study, we combined high-resolution imaging and 3D electron density information provided by cryo-soft X-ray tomography to characterize mitochondria cristae morphology isolated from murine. Using the linear attenuation coefficient, the mitochondria were identified (0.247 ± 0.04 µm -1 ) presenting average dimensions of 0.90 ± 0.20 µm in length and 0.63 ± 0.12 µm in width. The internal mitochondria structure was successfully identified by reaching up the limit of spatial resolution of 35 nm. The internal mitochondrial membranes invagination (cristae) complexity was calculated by the mitochondrial complexity index (MCI) providing quantitative and morphological information of mitochondria larger than 0.90 mm in length. The segmentation to visualize the cristae invaginations into the mitochondrial matrix was possible in mitochondria with MCI ≥ 7. Altogether, we demonstrated that the MCI is a valuable quantitative morphological parameter to evaluate cristae modelling and can be applied to compare healthy and disease state associated to mitochondria morphology.

3-D reconstruction↗

Phonon emission in germanium and silicon by electrons and holes in applied electric field at low temperature

The cryogenic dark matter search employs Ge and Si detectors to search for weakly interacting massive particle dark matter via its elastic-scattering interactions with nuclei while discriminating against interactions of background particles. These detectors distinguish nuclear recoils from electron recoils by simultaneously measuring phonon and ionization production in semiconducting substrates at sub-kelvin temperatures. They also reconstruct event position by quadrant-segmented measurement of the phonon signal. The ionization drift field does work on the electrons and holes. The charge carriers radiate this energy as acoustic phonons. At the typical applied field of 300 V/m in Ge (400 V/m in Si), we self-consistently model the behavior of the electrons and holes using independent drifted Maxwellian distributions, each characterized by an average drift velocity and an effective temperature, and including acoustic phonon emission. We calculate the phonon power angular and frequency distributions. We find that the bias polarity affects these distributions and, therefore, the phonon collection efficiency in Ge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-814: Whole Breast Irradiation with Two Different Intensity Modulation Radiotherapy Techniques

Purpose: Breast cancer now mainly received forward intensity modulation radiotherapy (f-IMRT) and inverse IMRT (i-IMRT). The purpose of this study was to observe the differences of two treatment methods. Methods: 10 patients after left breast-conserving surgery were selected to receive radiotherapy. For each patient, two treatment plans (f-IMRT and i-IMRT) were designed. For f-IMRT plans, two tangent beams were designed to the target, and in each tangent orientation two or three segment beams were designed to reduced high dose region in the target and the dose of lung received. For i-IMRT plans, two tangent beams were designed to the target and the treatment planning system optimize the dose according to the optimization parameters. For each plan 50Gy was prescribed. Results: In f-IMRT and i-IMRT plans, the average target conformal index (CI) were (0.67±0.06) and (0.66±0.06), (P>0.05); average homogeneity index (HI) were (28.2±6.0)% and (26.1±6.8)%, (P>0.05); volume of left lung received 20Gy (V20) were (18.7±3.3)% and (17.0±2.8)%, (P<0.05), V30 were (15.5±3.0)% and (14.0±2.6)%, (P<0.05); V30 of heart were (4.1±3.1)% and (3.5±2.5)%, (P>0.05); Monitor Unit (MU) were (262±5)MU and (308±14)MU. Conclusion: Compared with i-IMRT plan, for breast cancer, the differences of CI and HI were not significant. Because of fewer MU, f-IMRT plan could reduce the machine abrasion and treatment time, but dose of normal tissue received were higher significantly than i-IMRT plan.

60 APPLIED LIFE SCIENCES↗

Improved Microbial Community Characterization of 16S rRNA via Metagenome Hybridization Capture Enrichment

Environmental microbial diversity is often investigated from a molecular perspective using 16S ribosomal RNA (rRNA) gene amplicons and shotgun metagenomics. While amplicon methods are fast, low-cost, and have curated reference databases, they can suffer from amplification bias and are limited in genomic scope. In contrast, shotgun metagenomic methods sample more genomic regions with fewer sequence acquisition biases, but are much more expensive (even with moderate sequencing depth) and computationally challenging. Here, we develop a set of 16S rRNA sequence capture baits that offer a potential middle ground with the advantages from both approaches for investigating microbial communities. These baits cover the diversity of all 16S rRNA sequences available in the Greengenes (v. 13.5) database, with no sequence having <78% sequence identity to at least one bait for all segments of 16S. The use of our baits provide comparable results to 16S amplicon libraries and shotgun metagenomic libraries when assigning taxonomic units from 16S sequences within the metagenomic reads. We demonstrate that 16S rRNA capture baits can be used on a range of microbial samples (i.e., mock communities and rodent fecal samples) to increase the proportion of 16S rRNA sequences (average > 400-fold) and decrease analysis time to obtain consistent community assessments. Furthermore, our study reveals that bioinformatic methods used to analyze sequencing data may have a greater influence on estimates of community composition than library preparation method used, likely due in part to the extent and curation of the reference databases considered. Thus, enriching existing aliquots of shotgun metagenomic libraries and obtaining modest numbers of reads from them offers an efficient orthogonal method for assessment of bacterial community composition.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Numerical Simulation of Acoustic Noise Generation from the Nozzle Wall of a Hypersonic Wind Tunnel

The acoustic radiation from the turbulent boundary layer on the nozzle wall of a Mach 6 Ludwieg Tube is simulated using Direct Numerical Simulations (DNS), with the flow conditions falling within the operational range of the Mach 6 Hypersonic Ludwieg Tube, Braunschweig (HLB). The mean and turbulence statistics of the nozzle-wall boundary layer show good agreement with those predicted by Pate's correlation and Reynolds Averaged Navier-Stokes (RANS) computations. The rms pressure fluctuation P'(rms)/T(w) plateaus in the freestream core of the nozzle. The intensity of the freestream noise within the nozzle is approximately 20% higher than that radiated from a single at pate with a similar freestream Mach number, potentially because of the contributions to the acoustic radiation from multiple azimuthal segments of the nozzle wall.

Huang, Junji↗

FUEL PERFORMANCE STUDIES AT IDAHO NATIONAL LABORATORY MAKING USE OF THE BYRON FUEL SHIPMENT

In December of 2023 a shipment of commercially irradiated fuel rods from the Byron Generating Station in Illinois was successfully shipped to the Materials and Fuels Complex (MFC) at Idaho National Laboratory (INL). The make-up of the rods includes a mix of cladding types from traditional ZirloTM, advanced zirconium alloys, and chrome coated ZirloTM. Burnups range from regular end of life values to over 70 GWd/MTU rod average. The R&D plan for the rods involves multiple projects from developing licensing data for new claddings to integral transient tests to support burnup extension efforts in the United States. The R&D began in early 2024 with the nondestructive examinations of the rods after which they will be sectioned for microscopy, mechanical testing, and analytical chemistry. Additionally, many rod segments will be refabricated into new test pins and inserted into a static water capsule for integral Reactivity Initiated Accident (RIA) and Loss of Coolant Accident (LOCA) testing at the TREAT reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dataset_for_Molecular_Motion_Below_the_Glass_Transition_A_Solid-State_NMR_Study_of_Siloxane_Polymer_Dynamics Study

This dataset contains solid-state 1H and 13C NMR relaxometry data, differential scanning calorimetry (DSC) data, and size exclusion chromatography (SEC/GPC) data supporting the study of sub-glass-transition (sub-Tg) molecular dynamics in a composition- and sequence-controlled series of diphenyl-substituted polysiloxanes (PDMS, 14Ph, 33Ph, 50Ph, 67Ph, and 100Ph; 0–100% diphenylsiloxane content by mole).All solid-state NMR data were acquired on a 200 MHz Bruker Avance III HD spectrometer using a static 7 mm HX probe or a 4 mm HX probe under 4 kHz magic-angle spinning. Raw Bruker TopSpin experiment folders are included for: (1) variable-temperature 1H lineshape measurements used to determine linewidth (FWHM) as a function of temperature across the glass transition; (2) 1H T1 (saturation recovery with solid-echo detection), probing nanosecond-scale dynamics near the 1H Larmor frequency; (3) 1H T1rho (direct spin-lock, 62.5 kHz), probing microsecond-scale segmental dynamics; (4) 13C-detected Lee–Goldburg cross-polarization 1H T1rho (LGCPH T1rho) for 33Ph and 50Ph, resolving aromatic and aliphatic proton environments; and (5) 13C T1 relaxation for 33Ph and 50Ph. Differential scanning calorimetry data (TA Instruments DSC 25, −150 to +120 °C, up to +300 °C for 100Ph, 10 °C/min) are included for all six compositions and support the glass-transition temperatures in Table 1 and Figure 1. Size exclusion chromatography data (Agilent 1200 Series, PL-Gel 300 mixed-C column, THF mobile phase, polystyrene calibration standards) are included for the three synthesized copolymers (33Ph, 50Ph, 67Ph) and support the number-average molecular weights in Table 1. Processed data include per-composition relaxation-time summaries (Excel), curve-fitting and Bloembergen-Purcell-Pound (BPP) model analysis notebooks (Jupyter/Python), and Igor Pro (.pxp) master files used to generate the manuscript's figures.

Bloembergen-Purcell-Pound theory↗

Disentangling Rotational Dynamics and Ordering Transitions in a System of Self-Organizing Protein Nanorods via Rotationally Invariant Latent Representations

The dynamics of complex ordering systems with active rotational degrees of freedom exemplified by protein self-assembly is explored using a machine learning workflow that combines deep learning-based semantic segmentation and rotationally invariant variational autoencoder-based analysis of orientation and shape evolution. The latter allows for disentanglement of the particle orientation from other degrees of freedom and compensates for lateral shifts. The disentangled representations in the latent space encode the rich spectrum of local transitions that can now be visualized and explored via continuous variables. The time dependence of ensemble averages allows insight into the time dynamics of the system and, in particular, illustrates the presence of the potential ordering transition. Finally, analysis of the latent variables along the single-particle trajectory allows tracing these parameters on a single-particle level. The proposed approach is expected to be universally applicable for the description of the imaging data in optical, scanning probe, and electron microscopy seeking to understand the dynamics of complex systems where rotations are a significant part of the process.

representation learning↗