Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Note: A resonating reflector-based optical system for motion measurement in micro-cantilever arrays

A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulation and Modeling of Three-Dimensional Nanowire Assemblies Targeting Gas Sensors with High Response and Reliability

Despite improved sensitivity, simple downsizing of gas-sensing components to randomly arranged nanostructures often faces challenges associated with unpredictable electrical conduction pathways. In the present study, controlled fabrication of three-dimensional (3D) metal oxide nanowire networks is demonstrated that can greatly improve both signal stability and sensor response compared to random nanowire arrays. For example, the highest ever reported H 2 S gas response value, and a 5 times lower relative standard deviation of baseline resistance than that of random nanowires assemblies, are achieved with the ordered 3D nanowire network. Systematic engineering of 3D geometries and their modeling, utilizing equivalent circuit components, provide additional insights into the electrical conduction and gas-sensing response of 3D assemblies, revealing the critical importance of wire-to-wire junction points and their arrangement. Here these findings suggest new design rules for both enhanced performance and reliability of chemical sensors, which may also be extended to other devices based on nanoscale building blocks.

36 MATERIALS SCIENCE↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lens-free compound eye cameras based on angle-sensitive meta-surfaces

A lens-free ultrathin imaging sensor using a compound-eye vision modality can be formed by forming a metasurface on each pixel of an array of pixels in a solid state imaging sensor. The metasurface can be configured to form a diffraction grating that directs light incident on the metasurface at a predefined angle to excite surface plasmon polaritons into the solid state imaging sensor and light incident at any other angle is reflected or diffracted away from the metasurface. Each pixel of the imaging sensor can be configured using the metasurface to only receive light incident from a different portion of a field of view. A computational imaging system can be used to construct the image from the individual pixels.

Paiella, Roberto↗

Advanced Energy Scale Correction Techniques for the X-ray Transition Edge Sensors of the Athena mission

The X-ray Integral Field Unit (X-IFU) onboard the future European X-ray telescope Athena will be the first space instrument carrying an array of more than a thousand transition edge sensors. One of the key challenges of the X-IFU is the measurement of narrow X-ray atomic lines to determine velocity shifts at an unprecedented level of accuracy. For this reason, the energy scale of the instrument needs to be known with extreme accuracy, of 0.4 eV (1σ) up to 7 keV. The energy scale will be measured on the ground through a dedicated calibration campaign using fiducial X-ray sources. Though calibrated, the energy scale is extremely sensitive to the environmental conditions around the TES array, and drifts in the readout chain electronics. Uncorrected, the energy scale can naturally drift up to hundreds of eVs. Changes of the TES gain will be monitored via onboard X-ray calibration sources, and the energy scale will be corrected either per pixel, or within a small groups of pixels. Although simulations show that a 0.4 eV level can be achieved, the very high accuracy required by the X-IFU calls for experimental validation. A dedicated measurement campaign has been performed by NASA Goddard Space Flight Center to characterize the energy scale of a prototype kilo-pixel array of X-IFU-representative TESs. The analysis of the data demonstrated the ability to correct for various drifts using two fiducial lines to track the temporal gain variation. In this paper, we propose to extend this study on the same data set by investigating multi-parameter correction techniques based on both the pulse-height of the fiducial line and the prepulse baseline level, using the knowledge of the TES energy scale at reference temperature/magnetic field set points acquired on the ground. Investigations on the co-adding of pixels to perform a joint correction over pools of pixels is also explored.

79 ASTRONOMY AND ASTROPHYSICS↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

The resilient hybrid fiber sensor network with self-healing function

This paper presents a novel resilient fiber sensor network (FSN) with multi-ring architecture, which could interconnect various kinds of fiber sensors responsible for more than one measurands. We explain how the intelligent control system provides sensors with self-healing function meanwhile sensors are working properly, besides each fiber in FSN is under real-time monitoring. We explain the software process and emergency mechanism to respond failures or other circumstances. To improve the efficiency in the use of limited spectrum resources in some situations, we have two different structures to distribute the light sources rationally. Then, we propose a hybrid sensor working in FSN which is a combination of a distributed sensor and a FBG (Fiber Bragg Grating) array fused in a common fiber sensing temperature and vibrations simultaneously with neglectable crosstalk to each other. By making a failure to a working fiber in experiment, the feasibility and effectiveness of the network with a hybrid sensor has been demonstrated, hybrid sensors could not only work as designed but also survive from destructive failures with the help of resilient network and smart and quick self-healing actions. The network has improved the viability of the fiber sensors and diversity of measurands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam emission spectroscopy turbulence imaging system for the MAST spherical tokamak

A new beam emission spectroscopy turbulence imaging system has recently been installed onto the MAST spherical tokamak. The system utilises a high-throughput, direct coupled imaging optics, and a single large interference filter for collection of the Doppler shifted D{sub {alpha}} emission from the {approx}2 MW heating beam of {approx}70 keV injection energy. The collected light is imaged onto a 2D array detector with 8 x 4 avalanche photodiode sensors which is incorporated into a custom camera unit to perform simultaneous 14-bit digitization at 2 MHz of all 32 channels. The array is imaged at the beam to achieve a spatial resolution of {approx}2 cm in the radial (horizontal) and poloidal (vertical) directions, which is sufficient for detection of the ion-scale plasma turbulence. At the typical photon fluxes of {approx}10{sup 11} s{sup -1} the achieved signal-to-noise ratio of {approx}300 at the 0.5 MHz analogue bandwidth is sufficient for detection of relative density fluctuations at the level of a few 0.1%. The system is to be utilised for the study of the characteristics of the broadband, ion-scale turbulence, in particular its interaction with flow shear, as well as coherent fluctuations due to various types of MHD activity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of silicon photomultipliers and their applications to GlueX calorimetry

The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 × 1.2 cm{sup 2}) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and implementation of an array of micro-electrochemical detectors for two-dimensional liquid chromatography-proof of principle

Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time x space and space x space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm x 100 mm x 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 {micro}m polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3 M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Josephson Effects in Frequency-Domain Multiplexed TES Microcalorimeters and Bolometers

Frequency-division multiplexing is the baseline read-out system for large arrays of superconducting transition-edge sensors (TES’s) under development for the X-ray and infrared instruments like X-IFU (Athena) and SAFARI, respectively. In this multiplexing scheme, the sensors are ac-biased at different frequencies from 1 to 5 MHz and operate as amplitude modulators. Weak superconductivity is responsible for the complex TES resistive transition, experimentally explored in great detail so far, both with dc- and ac-biased read-out schemes. In this paper, we will review the current status of our understanding of the physics of the TES’s and their interaction with the ac bias circuit. In particular, we will compare the behaviour of the TES nonlinear impedance, across the superconducting transition, for several detector families, namely: high-normal-resistance TiAu TES bolometers, low-normal-resistance MoAu TES microcalorimeters and high-normal-resistance TiAu TES microcalorimeters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca 2+ and pH

Homeostasis of ionized calcium in biofluids is critical for human biological functions and organ systems. Measurement of ionized calcium for clinical applications is not easily accessible due to its strict procedures and dependence on pH. pH balance in body fluids greatly affects metabolic reactions and biological transport systems. Here, we demonstrate a wearable electrochemical device for continuous monitoring of ionized calcium and pH of body fluids using a disposable and flexible array of Ca 2+ and pH sensors that interfaces with a flexible printed circuit board. This platform enables real-time quantitative analysis of these sensing elements in body fluids such as sweat, urine, and tears. Accuracy of Ca 2+ concentration and pH measured by the wearable sensors is validated through inductively coupled plasma-mass spectrometry technique and a commercial pH meter, respectively. Our results show that the wearable sensors have high repeatability and selectivity to the target ions. Real-time on-body assessment of sweat is also performed, and our results indicate that calcium concentration increases with decreasing pH. Finally, this platform can be used in noninvasive continuous analysis of ionized calcium and pH in body fluids for disease diagnosis such as primary hyperparathyroidism and kidney stones.

47 OTHER INSTRUMENTATION↗

Kinetics of solid-gas reactions characterized by scanning AC nano-calorimetry with application to Zr oxidation

Scanning AC nano-calorimetry is a recently developed experimental technique capable of measuring the heat capacity of thin-film samples of a material over a wide range of temperatures and heating rates. Here, we describe how this technique can be used to study solid-gas phase reactions by measuring the change in heat capacity of a sample during reaction. We apply this approach to evaluate the oxidation kinetics of thin-film samples of zirconium in air. The results confirm parabolic oxidation kinetics with an activation energy of 0.59 ± 0.03 eV. The nano-calorimetry measurements were performed using a device that contains an array of micromachined nano-calorimeter sensors in an architecture designed for combinatorial studies. We demonstrate that the oxidation kinetics can be quantified using a single sample, thus enabling high-throughput mapping of the composition-dependence of the reaction rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

BICEP2. II. Experiment and three-year data set

We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrasound direction of arrival determination using a balloon-borne aeroseismometer

Free-floating balloons are an emerging platform for infrasound recording, but they cannot host arrays sufficiently wide for multi-sensor acoustic direction finding techniques. Because infrasound waves are longitudinal, the balloon motion in response to acoustic loading can be used to determine the signal azimuth. This technique, called “aeroseismometry,” permits sparse balloon-borne networks to geolocate acoustic sources. This is demonstrated by using an aeroseismometer on a stratospheric balloon to measure the direction of arrival of acoustic waves from successive ground chemical explosions. A geolocation algorithm adapted from hydroacoustics is then used to calculate the location of the explosions.

47 OTHER INSTRUMENTATION↗

Observations of Stably Stratified Flow through a Microscale Gap

This paper reports the findings of a comprehensive field investigation on flow through a mountain gap subject to a range of stably stratified environmental conditions. This study was embedded within the Perdigão field campaign, which was conducted in a region of parallel double-ridge topography with ridge-normal wind climatology. One of the ridges has a well-defined gap (col) at the top, and an array of in situ and remote sensors, including a novel triple Doppler lidar system, was deployed around it. The experimental design was mostly guided by previous numerical and theoretical studies conducted with an idealized configuration where a flow (with characteristic velocity U 0 and buoyancy frequency N ) approaches normal to a mountain of height h with a gap at its crest, for which the governing parameters are the dimensionless mountain height G= (Nh)/U 0 and various gap aspect ratios. Modified forms of G were proposed to account for real-world atmospheric variability, and the results are presented in terms of a gap-averaged value G c . The nature of gap flow was highly dependent on G c , wherein a nearly neutral flow regime (G c <1), a transitional mountain wave regime (G c ~O(1)), and a gap-jetting regime ( G c >O(1)) were identified. The measurements were in broad agreement with previous numerical and theoretical studies on a single ridge with a gap or double ridge topography, although details vary. This is the first ever detailed field study reported on microscale (O(100 m)) gap flows, and provides useful data and insights for future theoretical and numerical studies.

Microscale, Gap, environmental fluid dynamics, win↗

Single-shot picosecond pump coherent Rayleigh scattering thermometry

A single-shot coherent Rayleigh scattering (CRS) technique capable of measurement times less than 10 ns is presented. Here, the use of a mode-locked picosecond pump laser yields repeatable electrostrictive forcing compared to previous CRS experiments using unseeded nanosecond pump pulses, which are beset by shot-to-shot variations. Quantitative measurements are achieved by dispersing the CRS signal onto an EMCCD sensor using a virtually imaged phased array and comparing the experimental spectra to an existing kinetic model with a least-squares fitting routine. Measurements are demonstrated at ambient and low-pressure (2 Torr), low-temperature (100 K) conditions where the CRS measurement is within the collisionless regime. Single-shot statistics indicated precision and accuracy within 4% at ambient conditions and within 8% at low density and temperature conditions. This single-shot CRS technique is a powerful diagnostic tool with potential for multi-parameter measurements in complex flow environments, including high-speed aerodynamic ground test facilities.

Senior, William Charles Bowman [Sandia National La↗