Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Photoluminescence Intensity Fluctuations and Temperature-Dependent Decay Dynamics of Individual Carbon Nanotube sp 3 Defects

Recent demonstration of room temperature, telecommunication wavelength single photon generation by sp 3 defects of single wall carbon nanotubes established these defects as a new class of quantum materials. However, their practical utilization in development of quantum light sources calls for a significant improvement in their imperfect quantum yield (QY~10–30%). PL intensity fluctuations observed with some defects also need to be eliminated. Aiming toward attaining fundamental understanding necessary for addressing these critical issues, we investigate PL intensity fluctuation and PL decay dynamics of aryl sp 3 defects of (6,5), (7,5), and (10,3) single wall carbon nanotubes (SWCNTs) at temperatures ranging from 300 to 4 K. By correlating defect-state PL intensity fluctuations with change (or lack of change) in PL decay dynamics, we identified random variations in the trapping efficiency of E 11 band-edge excitons (likely resulting from the existence of a fluctuating potential barrier in the vicinity of the defect) as the mechanism mainly responsible for the defect PL intensity fluctuations. Furthermore, by analyzing the temperature dependence of PL intensity and decay dynamics of individual defects based on a kinetic model involving the trapping and detrapping of excitons by optically allowed and forbidden (bright and dark) defect states, we estimate the height of the potential barrier to be in the 3–22 meV range. Our analysis also provides further confirmation of recent DFT simulation results that the emissive sp 3 defect state is accompanied by an energetically higher-lying optically forbidden (dark) exciton state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simulating dust grain-radiation coupling on a moving mesh

ABSTRACT We present a model for the interaction between dust and radiation fields in the radiation hydrodynamic code arepo-rt, which solves the moment-based radiative transfer equations on an unstructured moving mesh. Dust is directly treated using live simulation particles, each of which represent a population of grains that are coupled to hydrodynamic motion through a drag force. We introduce methods to calculate radiation pressure on and photon absorption by dust grains. By including a direct treatment of dust, we are able to calculate dust opacities and update radiation fields self-consistently based on the local dust distribution. This hybrid scheme coupling dust particles to an unstructured mesh for radiation is validated using several test problems with known analytic solutions, including dust driven via spherically symmetric flux from a constant luminosity source and photon absorption from radiation incident on a thin layer of dust. Our methods are compatible with the multifrequency scheme in arepo-rt, which treats UV, optical photons as single scattered and IR photons as multi scattered. At IR wavelengths, we model heating of and thermal emission from dust. Dust and gas are not assumed to be in local thermodynamic equilibrium but transfer energy through collisional exchange. We estimate dust temperatures by balancing these dust-radiation and dust-gas energy exchange rates. This framework for coupling dust and radiation can be applied in future radiation hydrodynamic simulations of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

High-power Waveguide Dampers for the Short-Pulse X-Ray Project at the Advanced Photon Source

High-power waveguide dampers have been designed and prototyped for the Short-Pulse X-ray (SPX) cavities at the Advanced Photon Source. The cavities will operate at 2.815 GHz and utilize the TM110 dipole mode. As a result, higher-order (HOM) and lower-order mode (LOM) in-vacuum dampers have been designed to satisfy the demanding broadband damping requirements in the APS storage ring. The SPX single-cell cavity consists of two WR284 waveguides for damping the HOMs and one WR284 waveguide for primarily damping the LOM where up to 2kW will be dissipated in the damping material. The damper designs and high-power experimental results will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Atom detection in a two-mode optical cavity with intermediate coupling: Autocorrelation studies

We use an optical cavity in the regime of intermediate coupling between atom and cavity mode to detect single moving atoms. Degenerate polarization modes allow excitation of the atoms in one mode and collection of spontaneous emission in the other while keeping separate the two sources of light; we obtain a higher confidence and efficiency of detection by adding cavity-enhanced Faraday rotation. Both methods greatly benefit from coincidence detection of photons, attaining fidelities in excess of 99% in less than 1 {mu}s. Detailed studies of the second-order intensity autocorrelation function of light from the signal mode reveal evidence of antibunched photon emissions and the dynamics of single-atom transits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Collaborative development of diffraction-limited beamline optical systems at US DOE light sources

An ongoing collaboration among four US Department of Energy National Laboratories has demonstrated key technology prototypes and software modeling tools required for new high-coherent flux beamline optical systems. New free electron laser (FEL) and diffraction-limited storage ring (DLSR) light sources demand wavefront preservation from source to sample to achieve and maintain optimal performance. Fine wavefront control was achieved using a novel, roomtemperature cooled mirror system called REAL (resistive element adjustable length) that combines cooling with applied, spatially variable auxiliary heating. Single-grating shearing interferometry (also called Talbot interferometry) and Hartmann wavefront sensors were developed and used for optical characterization and alignment on several beamlines, across a range of photon energies. Demonstrations of non-invasive hard x-ray wavefront sensing were performed using a thin diamond single-crystal as a beamsplitter.

Goldberg, Kenneth A.↗

Shielded radiography with a laser-driven MeV-energy X-ray source

We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 10 7 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ~100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam’s inherently low-divergence angle (~mrad) is advantageous and effective for interrogation at standoff distance. Furthermore, these results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scalable multiphoton quantum metrology with neither pre- nor post-selected measurements

The quantum statistical fluctuations of electromagnetic fields establish a limit, known as the shot-noise limit, on the sensitivity of optical measurements performed with classical technologies. However, quantum technologies are not constrained by this shot-noise limit. In this regard, the possibility of using every photon produced by quantum sources of light to estimate small physical parameters, beyond the shot-noise limit, constitutes one of the main goals of quantum optics. Here, we experimentally demonstrate a scalable protocol for quantum-enhanced optical phase estimation across a broad range of phases, with neither pre- nor post-selected measurements. This is achieved through the efficient design of a source of spontaneous parametric downconversion in combination with photon-number-resolving detection. The robustness of two-mode squeezed vacuum states against loss allows us to outperform schemes based on N00N states, in which the loss of a single photon is enough to remove all phase information from a quantum state. In contrast to other schemes that rely on N00N states or conditional measurements, the sensitivity of our technique could be improved through the generation and detection of high-order photon pairs. This unique feature of our protocol makes it scalable. Furthermore, our work is important for quantum technologies that rely on multiphoton interference such as quantum imaging, boson sampling, and quantum networks.

36 MATERIALS SCIENCE↗

FOUR PI CALIBRATION AND MODELING OF A BARE GERMANIUM DETECTOR IN A CYLINDRICAL FIELD SOURCE

In reference 1 the authors described {gamma}-ray holdup assay of a Mossbauer spectroscopy instrument where they utilized two axial symmetric cylindrical shell acquisitions and two disk source acquisitions to determine Am-241 and Np-237 contamination. The measured contents of the two species were determined using a general detector efficiency calibration taken from a 12-inch point source.2 The authors corrected the raw spectra for container absorption as well as for geometry corrections to transform the calibration curve to the applicable axial symmetric cylindrical source - and disk source - of contamination. The authors derived the geometry corrections with exact calculus that are shown in equations (1) and (2) of our Experimental section. A cylindrical shell (oven source) acquisition configuration is described in reference 3, where the authors disclosed this configuration to gain improved sensitivity for holdup measure of U-235 in a ten-chamber oven. The oven was a piece of process equipment used in the Savannah River Plant M-Area Uranium Fuel Fabrication plant for which a U-235 holdup measurement was necessary for its decontamination and decommissioning in 2003.4 In reference 4 the authors calibrated a bare NaI detector for these U-235 holdup measurements. In references 5 and 6 the authors calibrated a bare HpGe detector in a cylindrical shell configuration for improved sensitivity measurements of U-235 in other M-Area process equipment. Sensitivity was vastly improved compared to a close field view of the sample, with detection efficiency of greater than 1% for the 185.7-keV {gamma}-ray from U-235. In none of references 3 - 7 did the authors resolve the exact calculus descriptions of the acquisition configurations. Only the empirical efficiency for detection of the 185.7-keV photon from U-235 decay was obtained. Not until the 2010 paper of reference 1 did the authors derive a good theoretical description of the flux of photons onto the front face of a detector from an axially symmetric cylindrical shell. Subsequent to publication of 1, the theoretical treatment of the cylindrical shell and disk source acquisition sources was recognized by the Los Alamos National Laboratory as suitable for including in the Safeguards Training Program.8 Therefore, we felt it was important to accurately demonstrate the calculus describing the cylindrical shell configuration for the HpGe detector and to theoretically account for the observed bare-detector efficiencies measured in references (3-6). In this paper we demonstrate the applicability of the cylindrical shell derivation to a flexible planar sheet of known Am-241, Eu-152, and Cs-137 activity that we rolled into a symmetrical cylindrical shell of radioactivity. Using the geometry correction equation of reference 1, we calculate geometry correction values using the known detector and source dimensions combined with source to detector distances. We then compare measured detection efficiencies from a cylindrical shell of activity for the 185.7-keV photon (U-235) and for the 414.3-keV photon (Pu-239) with those determined for a 12-inch point source(2,7) to demonstrate agreement between experiment and the theoretically calculated values derived by the Savannah River National Laboratory (SRNL) authors of reference 1. We demonstrate this geometry correction first for the 185.7- and 414.3-keV {gamma}-rays. But because the detector was point source calibrated at 12 inches for the energy range (60 -1700) keV (using two distinct sources) to map its intrinsic efficiency, the geometry correction for any acquisition configuration holds for all photon energies.2 We demonstrate that for ten photon energies in the range 121 keV to 967 keV. The good agreement between experiment and calculation is demonstrated at five source to detector distances using the identical shielded HpGe detector of references 4-7 as well as with a separate HpGe detector. We then extend the measurement to include a single acquisition where the flexible source is wrapped around the bare detector in a symmetrical cylinder that radiates on both faces of the detector as well as on to the detector's cylindrical sides of known dimensions. We derive the exact calculus to calculate the flux of the source on to the cylindrical sides of the detector. We then demonstrate outstanding agreement between the measured efficiency for the two primary U-235 and Pu-239 photons in this oven source configuration compared to the point source of activity for which the detector was originally calibrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Narrow Line X-Ray Calibration Source for High Resolution Microcalorimeters

We are developing a narrow line calibration source for use with X-ray microcalorimeters. At energies below 300 electronvolts fluorescent lines are intrinsically broad, making calibration of high resolution detectors difficult. This source consists of a 405 nanometers (3 electronvolts) laser diode coupled to an optical fiber. The diode is pulsed to create approximately one hundred photons in a few microseconds. If the pulses are short compared to the rise time of the detector, they will be detected as single events with a total energy in the soft X-ray range. Poisson fluctuations in photon number per pulse create a comb of X-ray lines with 3 electronvolts spacing, so detectors with energy resolution better than 2 electronvolts are required to resolve the individual lines. Our currently unstabilized diode has a multimode width less than 1 nanometer, giving a 300 electronvolt event a Full width at half maximum (FWHM) less than 0.1 electronvolts. By varying the driving voltage, or pulse width, the source can produce a comb centered on a wide range of energies. The calibration events are produced at precisely known times. This allows continuous calibration of a flight mission without contaminating the observed spectrum and with minimal deadtime.

high resolution detectors↗

Parabolic single-crystal diamond lenses for coherent x-ray imaging

We demonstrate parabolic single-crystal diamond compound refractive lenses designed for coherent x-ray imaging resilient to extreme thermal and radiation loading expected from next generation light sources. To ensure the preservation of coherence and resilience, the lenses are manufactured from the highest-quality single-crystalline synthetic diamond material grown by a high-pressure high-temperature technique. Picosecond laser milling is applied to machine lenses to parabolic with a similar or equal to 1 mu m precision and surface roughness. A compound refractive lens comprised of six lenses with a radius of curvature R = 200 mu m at the vertex of the parabola and a geometrical aperture A = 900 mu m focuses 10 keV x-ray photons from an undulator source at the Advanced Photon Source facility to a focal spot size of similar or equal to 20 x 90 mu m(2) with a gain factor of similar or equal to 50 - 100. (C) 2015 Author(s).

Terentyev, Sergey↗

THE FIFTH DATA RELEASE SLOAN DIGITAL SKY SURVEY/XMM-NEWTON QUASAR SURVEY

We present a catalog of 792 Fifth Data Release Sloan Digital Sky Survey quasars with optical spectra that have been observed serendipitously in the X-rays with the XMM-Newton. These quasars cover a redshift range of z = 0.11-5.41 and a magnitude range of i = 15.3-20.7. Substantial numbers of radio-loud (70) and broad absorption line (51) quasars exist within this sample. Significant X-ray detections at {>=}2{sigma} account for 87% of the sample (685 quasars), and 473 quasars are detected at {>=}6{sigma}, sufficient to allow X-ray spectral fits. For detected sources, {approx}60% have X-ray fluxes between F {sub 2-10keV} = (1-10) x10{sup -14} erg cm{sup -2} s{sup -1}. We fit a single power law, a fixed power law with intrinsic absorption left free to vary, and an absorbed power-law model to all quasars with X-ray signal-to-noise ratio {>=} 6, resulting in a weighted mean photon index {gamma} = 1.91 {+-} 0.08, with an intrinsic dispersion {sigma}{sub {gamma}} = 0.38. For the 55 sources (11.6%) that prefer intrinsic absorption, we find a weighted mean N{sub H} = 1.5 {+-} 0.3 x 10{sup 21} cm{sup -2}. We find that {gamma} correlates significantly with optical color, {delta}(g - i), the optical-to-X-ray spectral index ({alpha}{sub ox}), and the X-ray luminosity. While the first two correlations can be explained as artifacts of undetected intrinsic absorption, the correlation between {gamma} and X-ray luminosity appears to be a real physical correlation, indicating a pivot in the X-ray slope.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of extraneous mispositioned events on motion-corrected brain SPECT images of freely moving animals

Purpose: Single photon emission computed tomography (SPECT) brain imaging of freely moving small animals would allow a wide range of important neurological processes and behaviors to be studied, which are normally inhibited by anesthetic drugs or precluded due to the animal being restrained. While rigid body motion of the head can be tracked and accounted for in the reconstruction, activity in the torso may confound brain measurements, especially since motion of the torso is more complex (i.e., nonrigid) and not well correlated with that of the head. The authors investigated the impact of mispositioned events and attenuation due to the torso on the accuracy of motion corrected brain images of freely moving mice. Methods: Monte Carlo simulations of a realistic voxelized mouse phantom and a dual compartment phantom were performed. Each phantom comprised a target and an extraneous compartment which were able to move independently of each other. Motion correction was performed based on the known motion of the target compartment only. Two SPECT camera geometries were investigated: a rotating single head detector and a stationary full ring detector. The effects of motion, detector geometry, and energy of the emitted photons (hence, attenuation) on bias and noise in reconstructed brain regions were evaluated. Results: The authors observed two main sources of bias: (a) motion-related inconsistencies in the projection data and (b) the mismatch between attenuation and emission. Both effects are caused by the assumption that the orientation of the torso is difficult to track and model, and therefore cannot be conveniently corrected for. The motion induced bias in some regions was up to 12% when no attenuation effects were considered, while it reached 40% when also combined with attenuation related inconsistencies. The detector geometry (i.e., rotating vs full ring) has a big impact on the accuracy of the reconstructed images, with the full ring detector being more advantageous. Conclusions: Motion-induced inconsistencies in the projection data and attenuation/emission mismatch are the two main causes of bias in reconstructed brain images when there is complex motion. It appears that these two factors have a synergistic effect on the qualitative and quantitative accuracy of the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Tin–Lead Liquid Metal Alloy Source for Focused Ion Beams

Focused Ion Beam (FIB) systems are increasingly utilized in nanotechnology for nanostructuring, surface modification, doping, and rapid prototyping. Recently, their potential for quantum applications has been explored, leveraging FIB’s direct-write capabilities for in situ single ion implantation, which is crucial for fabricating single photon emitters. Color centers in diamond can function as qubits and are of particular interest due to their capacity to store and transmit quantum information. While Group-IV color centers exhibit high brightness, they require low temperatures to retain coherence. However, lead-vacancy in diamond (PbV) operates at the higher end (4 K) of this temperature spectrum due to larger ground-state splitting, making them particularly interesting. In this context, our study presents results for lead (Pb)-containing alloys with eutectic points below 600 °C and results on using tantalum (Ta) and titanium (Ti) as emitter materials for a Pb liquid metal alloy ion source. We show that a standard FIB system is able to resolve the different Pb isotopes and achieve nanoscale spot sizes, as required for quantum information science applications.

color center↗

Confinement of excited states in two-dimensional, in-plane, quantum heterostructures

Two-dimensional (2D) semiconductors are promising candidates for optoelectronic application and quantum information processes due to their inherent out-of-plane 2D confinement. In addition, they offer the possibility of achieving low-dimensional in-plane exciton confinement, similar to zero-dimensional quantum dots, with intriguing optical and electronic properties via strain or composition engineering. However, realizing such laterally confined 2D monolayers and systematically controlling size-dependent optical properties remain significant challenges. Here, we report the observation of lateral confinement of excitons in epitaxially grown in-plane MoSe 2 quantum dots (~15-60 nm wide) inside a continuous matrix of WSe 2 monolayer film via a sequential epitaxial growth process. Various optical spectroscopy techniques reveal the size-dependent exciton confinement in the MoSe 2 monolayer quantum dots with exciton blue shift (12-40 meV) at a low temperature as compared to continuous monolayer MoSe 2 . Finally, single-photon emission (g 2 (0) ~ 0.4) was also observed from the smallest dots at 1.6 K. Our study opens the door to compositionally engineered, tunable, in-plane quantum light sources in 2D semiconductors.

42 ENGINEERING↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗