Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SEEDS Moving Groups and CHARIS Status Updates

We present the status update for the SEEDS Moving Groups category. To date, we have observed 59 targets and currently have more than 20 candidates. We also present the expected scientific capabilities of CHARIS, the Coronagraphic High Angular Resolution Imaging Spectrograph, which is being built for the Subaru 8.2 m telescope of the National Astronomical Observatory of Japan. CHARIS will be implemented behind the new extreme adaptive optics system at Subaru, SCExAO, and the existing 188-actuator system AO188. CHARIS will offer three observing modes over near~infrared wavelengths from 0.9 to 2.4 microns (the y-, J-, H-, and K-bands), including a low-spectral-resolution mode covering this entire wavelength range and a high-resolution mode within a single band. With these capabilities, CHARIS will offer exceptional sensitivity for discovering giant exoplanets, and will enable detailed characterization of their atmospheres, CHARIS, the only planned high-contrast integral field spectrograph on an 8m-class telescope in the Northern Hemisphere, will complement the similar instruments such as Project 1640 at Palomar, and GPI and SPHERE in Chile.

McElwain, Michael↗

Comparisons of a Constrained Least Squares Model Versus Human-in-the-Loop for Spectral Unmixing to Determine Material Type of GEO Debris

Spectral reflectance data through the visible regime was collected at Las Campanas Observatory in Chile using an imaging spectrograph on one of the twin 6.5-m Magellan telescopes. The data were obtained on 1-2 May 2012 on the 'Landon Clay' telescope with the LDSS3 (Low Dispersion Survey Spectrograph 3). Five pieces of Geosynchronous Orbit (GEO) or near-GEO debris were identified and observed with an exposure time of 30 seconds on average. In addition, laboratory spectral reflectance data was collected using an Analytical Spectral Device (ASD) field spectrometer at California Polytechnic State University in San Luis Obispo on several typical common spacecraft materials including solar cells, circuit boards, various Kapton materials used for multi-layer insulation, and various paints. The remotely collected data and the laboratory-acquired data were then incorporated in a newly developed model that uses a constrained least squares method to unmix the spectrum in specific material components. The results of this model are compared to the previous method of a human-in-the-loop (considered here the traditional method) that identifies possible material components by varying the materials and percentages until a spectral match is obtained. The traditional model was found to match the remotely collected spectral data after it had been divided by the continuum to remove the space weathering effects, or a "reddening" of the materials. The constrained least-squares model also used the de-reddened spectra as inputs and the results were consistent with those obtained through the traditional method. For comparison, a first-order examination of including reddening effects into the constrained least-squares model will be explored and comparisons to the remotely collected data will be examined. The identification of each object's suspected material component will be discussed herein.

Rapp, Jason↗

Comparisons of a Constrained Least Squares Model versus Human-in-the-Loop for Spectral Unmixing to Determine Material Type of GEO Debris

Spectral reflectance data through the visible regime was collected at Las Campanas Observatory in Chile using an imaging spectrograph on one of the twin 6.5-m Magellan telescopes. The data were obtained on 1-2 May 2012 on the 'Landon Clay' telescope with the LDSS3 (Low Dispersion Survey Spectrograph 3). Five pieces of Geosynchronous Orbit (GEO) or near-GEO debris were identified and observed with an exposure time of 30 seconds on average. In addition, laboratory spectral reflectance data was collected using an Analytical Spectral Device (ASD) field spectrometer at California Polytechnic State University (Cal Poly) in San Luis Obispo on several typical common spacecraft materials including solar cells, circuit boards, various Kapton materials used for multi-layer insulation, and various paints. The remotely collected data and the laboratory-acquired data were then incorporated in a newly developed model that uses a constrained least squares method to unmix the spectrum in specific material components. The results of this model are compared to the previous method of a human-in-the-loop (considered here the traditional method) that identifies possible material components by varying the materials and percentages until a spectral match is obtained. The traditional model was found to match the remotely collected spectral data after it had been divided by the continuum to remove the space weathering effects, or a reddening of the materials. The constrained least-squares model also used the de-reddened spectra as inputs and the results were consistent with those obtained through the traditional method. For comparison, a first-order examination of including reddening effects into the constrained least-squares model will be explored and comparisons to the remotely collected data will be examined. The identification of each object s suspected material component will be discussed herein.

Abercromby, Kira J.↗

Sounding Rocket Instrument Development at UAHuntsville/NASA MSFC

We present an overview of solar sounding rocket instruments developed jointly by NASA Marshall Space Flight Center and the University of Alabama in Huntsville. The High Resolution Coronal Imager (Hi-C) is an EUV (19.3 nm) imaging telescope which was flown successfully in July 2012. The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a Lyman Alpha (121.6 nm) spectropolarimeter developed jointly with the National Astronomical Observatory of Japan and scheduled for launch in 2015. The Marshall Grazing Incidence X-ray Spectrograph is a soft X-ray (0.5-1.2 keV) stigmatic spectrograph designed to achieve 5 arcsecond spatial resolution along the slit.

Kobayashi, Ken↗

SOFIA Science Instruments: Commissioning, Upgrades and Future Opportunities

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is the world's largest airborne observatory, featuring a 2.5 meter telescope housed in the aft section of a Boeing 747sp aircraft. SOFIA's current instrument suite includes: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), a 5-40 μm dual band imager/grism spectrometer developed at Cornell University; HIPO (High-speed Imaging Photometer for Occultations), a 0.3-1.1 micron imager built by Lowell Observatory; FLITECAM (First Light Infrared Test Experiment CAMera), a 1-5 micron wide-field imager/grism spectrometer developed at UCLA; FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), a 42-210 micron IFU grating spectrograph completed by University Stuttgart; and EXES (Echelon-Cross- Echelle Spectrograph), a 5-28 micron high-resolution spectrometer being completed by UC Davis and NASA Ames. A second generation instrument, HAWC+ (Highresolution Airborne Wideband Camera), is a 50-240 micron imager being upgraded at JPL to add polarimetry and new detectors developed at GSFC. SOFIA will continually update its instrument suite with new instrumentation, technology demonstration experiments and upgrades to the existing instrument suite. This paper details instrument capabilities and status as well as plans for future instrumentation, including the call for proposals for 3rd generation SOFIA science instruments.

FLITECAM↗

Status of the JWST Science Instrument Payload

The James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) system consists of five sensors (4 science): Mid-Infrared Instrument (MIRI), Near Infrared Imager and Slitless Spectrograph (NIRISS), Fine Guidance Sensor (FGS), Near InfraRed Camera (NIRCam), Near InfraRed Spectrograph (NIRSpec); and nine instrument support systems: Optical metering structure system, Electrical Harness System; Harness Radiator System, ISIM Electronics Compartment, ISIM Remote Services Unit, Cryogenic Thermal Control System, Command and Data Handling System, Flight Software System, Operations Scripts System.

JWST Payload↗

Galaxy Evolution Spectroscopic Explorer: Scientific Rationale

GESE is a mission concept consisting of a 1.5-m space telescope and UV multi-object slit spectrograph designed to help understand galaxy evolution in a critical era in the history of the universe, where the rate of star-formation stopped increasing and started to decline. To isolate and identify the various processes driving the evolution of these galaxies, GESE will obtain rest-frame far-UV spectra of 100,000 galaxies at redshifts, z approximately 1-2. To obtain such a large number of spectra, multiplexing over a wide field is an absolute necessity. A slit device such as a digital micro-mirror device (DMD) or a micro-shutter array (MSA) enables spectroscopy of a hundred or more sources in a single exposure while eliminating overlapping spectra of other sources and blocking unwanted background like zodiacal light. We find that a 1.5-m space telescope with a MSA slit device combined with a custom orbit enabling long, uninterrupted exposures (approximately 10 hr) are optimal for this spectroscopic survey. GESE will not be operating alone in this endeavor. Together with x-ray telescopes and optical/near-IR telescopes like Subaru/Prime Focus Spectrograph, GESE will detect "feedback" from young massive stars and massive black holes (AGN's), and other drivers of galaxy evolution.

digital micro-mirror device (DMD)↗

Modeling the Scattering Polarization of the Hydrogen Ly-alpha Line Observed by CLASP in a Filament Channel

The 400 arcsec spectrograph slit of CLASP crossed predominantly quiet regions of the solar chromosphere, from the limb towards the solar disk center. Interestingly, in the CLASP slit-jaw images and in the SDO images of the He I line at 304 A, we can identify a filament channel (FC) extending over more than 60 arcsec crossing the spectrograph slit. In order to interpret the peculiar spatial variation of the Q/1 and U/1 signals observed by CLASP in the hydrogen Ly-alpha line (1216 A) and in the Si Ill line (1206 A) in such a filament channel, it is necessary to perform multi-dimensional radiative transfer modeling. In this contribution, we show the first results of the two-dimensional calculations we are carrying out in given filament models, with the aim of determining the filament thermal and magnetic structure by comparing the theoretical and the observed polarization signals.

CLASP↗

The James Webb Space Telescope: Contamination Control and Materials

The James Webb Space Telescope (JWST), expected to launch in 2018 or early 2019, will be the premier observatory for astronomers worldwide. It is optimized for infrared wavelengths and observation from up to 1 million miles from Earth. JWST includes an Integrated Science Instrument Module (ISIM) containing the four main instruments used to observe deep space: Near-Infrared Camera (NIRCam), Near-Infrared Spectrograph (NIRSpec), Mid-Infrared Instrument (MIRI), and Fine Guidance Sensor/Near InfraRed Imager and Slitless Spectrograph (FGS/NIRISS). JWST is extremely sensitive to contamination directly resulting in degradation in performance of the telescope. Contamination control has been an essential focus of this mission since the beginning of this observatory. A particular challenge has been contamination challenges in vacuum chamber operations.

James Webb Space Telescop↗

The Large UV/Optical/Infrared Surveyor (LUVOIR): Decadal Mission Concept Design Update

In preparation for the 2020 Astrophysics Decadal Survey, NASA has commissioned the study of four large mission concepts, including the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor. The LUVOIR Science and Technology Definition Team (STDT) has identified a broad range of science objectives including the direct imaging and spectral characterization of habitable exoplanets around sun-like stars, the study of galaxy formation and evolution, the epoch of reionization, star and planet formation, and the remote sensing of Solar System bodies. NASA’s Goddard Space Flight Center (GSFC) is providing the design and engineering support to develop executable and feasible mission concepts that are capable of the identified science objectives. We present an update on the first of two architectures being studied: a 15-meter-diameter segmented-aperture telescope with a suite of serviceable instruments operating over a range of wavelengths between 100 nm to 2.5 microns. Four instruments are being developed for this architecture: an optical / near-infrared coronagraph capable of 10(exp -10) contrast at inner working angles as small as 2 lambda/D; the LUVOIR UV Multi-object Spectrograph (LUMOS), which will provide low- and medium-resolution UV (100 – 400 nm) multi-object imaging spectroscopy in addition to far-UV imaging; the High Definition Imager (HDI), a high-resolution wide-field-of-view NUV-Optical-IR imager; and a UV spectro-polarimeter being contributed by Centre National d’Etudes Spatiales (CNES). A fifth instrument, a multi-resolution optical-NIR spectrograph, is planned as part of a second architecture to be studied in late 2017.

Decadal Study; Astrophysics; LUVOIR↗

The IFS for WFIRST CGI: Science Requirements to Design

Direct Imaging of exoplanets using a coronagraph has become a major field of research both on the ground and in space. Key to the science of direct imaging is the spectroscopic capabilities of the instrument, our ability to extract spectra, and measure the abundance of molecular species such as Methane. To take these spectra, the WFIRST coronagraph instrument (CGI) uses an integral field spectrograph (IFS), which encodes the spectrum into a two-dimensional image on the detector. This results in more efficient detection and characterization of targets, and the spectral information is critical to achieving detection limits below the speckle floor of the imager. The CGI IFS operates in two18% bands spanning 600nm to 840nm at a nominal spectral resolution of R50. We present the current science and engineering requirements for the IFS design, the instrument design, anticipated performance, and how the calibration is integrated into the focal plane wavefront control algorithms. We also highlight the role of the Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) at the JPL High Contrast Imaging Testbed to demonstrate performance and validate calibration methodologies for the flight instrument.

Groff, Tyler D.↗

Comet C/2013 V5 (Oukaimeden): Evidence for Depleted Organic Volatiles and Compositional Heterogeneity as Revealed through Infrared Spectroscopy

We obtained high-resolution (lambda divided by delta times lambda equals approximately 25,000) pre-perihelion spectra of Comet C/2013 V5 (Oukaimeden) using NIRSPEC at Keck II on UT 2014 September 5-6, and CSHELL (Cryogenic Echelle Spectrograph) at the NASA-Infrared Telescope Facility on September 11-13, altogether spanning a range in heliocentric distance R (sub h) equals 0.789-0.698 astronomical units. We report water production rates, and production rates and abundance ratios relative to co-measured H2O for eight trace molecules: CO, H2CO, CH3OH, CH4, C2H2, C2H6, HCN, and NH3. Our measured water production rates from NIRSPEC ( Near Infra-Red Spectrograph) and CSHELL observations remained relatively constant and were close to those from SOHO (Solar and Heliospheric Observatory) / Solar Wind Anisotropies observations that encompassed our dates, suggesting H2O production dominated by release directly from or within approximately 2000 kilometers of the nucleus. All trace volatiles were depleted relative to their respective median abundances among comets, excepting NH3, which was consistent with its median abundance. Most surprising were pronounced increases in abundance ratios for CH3OH (by 51 percent relative to simultaneously measured H2O) and especially C2H6 (by 87 percent) between September 5 and 6. On September 5, C2H6 was severely depleted, consistent with its lowest abundance yet measured for any comet. It also tracked the spatial profile of H2O, suggesting C2H6 was associated with a polar ice phase dominating gas production. On September 6, C2H6 was only moderately depleted and was spatially distinct from H2O, suggesting both polar- and nonpolar-dominated ice phases contributed to the activity then. Our results are consistent with a nonhomogeneous volatile composition for C/2013V5, implying differential processing of its constituent ices.

DiSanti, Michael A.↗

Capabilities, Performance, and Status of the SOFIA Science Instrument Suite

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is an airborne observatory, carrying a 2.5 m telescope onboard a heavily modified Boeing 747SP aircraft. SOFIA is optimized for operation at infrared wavelengths, much of which is obscured for ground-based observatories by atmospheric water vapor. The SOFIA science instrument complement consists of seven instruments: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), GREAT (German Receiver for Astronomy at Terahertz Frequencies), HIPO (High-speed Imaging Photometer for Occultations), FLITECAM (First Light Infrared Test Experiment CAMera), FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), EXES (Echelon-Cross-Echelle Spectrograph), and HAWC (High-resolution Airborne Wideband Camera). FORCAST is a 540 m imager with grism spectroscopy, developed at Cornell University. GREAT is a heterodyne spectrometer providing high-resolution spectroscopy in several bands from 60240 m, developed at the Max Planck Institute for Radio Astronomy. HIPO is a 0.31.1 m imager, developed at Lowell Observatory. FLITECAM is a 15 m wide-field imager with grism spectroscopy, developed at UCLA. FIFI-LS is a 42210 m integral field imaging grating spectrometer, developed at the University of Stuttgart. EXES is a 528 m high-resolution spectrograph, developed at UC Davis and NASA ARC. HAWC is a 50240 m imager, developed at the University of Chicago, and undergoing an upgrade at JPL to add polarimetry capability and substantially larger GSFC detectors. We describe the capabilities, performance, and status of each instrument, highlighting science results obtained using FORCAST, GREAT, and HIPO during SOFIA Early Science observations conducted in 2011.

SOFIA↗

LUVOIR: Engineering Design & Technology Overview

The Large Ultraviolet / Optical / Infrared Surveyor (LUVOIR) is one of four large mission concepts being study by NASA in preparation for the 2020 Decadal Survey in Astronomy and Astrophysics. Over the past three and a half years, the LUVOIR Science and Technology Definition Team (STDT) and Study Office at NASA's Goddard Space Flight Center have developed a broad, compelling science case for LUVOIR, and detailed engineering point designs to achieve it. In this paper, we provide an overview of the two LUVOIR concepts: LUVOIR-A, a 15-m segmented, obscured aperture observatory, and LUVOIR-B, an 8-m segmented, unobscured aperture observatory. Both versions of LUVOIR cover a broad spectral range between 100 nm and 2.5 µm with a suite of imagers and spectrographs, including the High Definition Imager (HDI), the LUVOIR Ultraviolet Multi-object Spectrograph (LUMOS), and the Extreme Coronagraph for Living Planetary Systems (ECLIPS). LUVOIR-A will carry an additional fourth instrument, Pollux, a high-resolution UV spectropolarimeter being studied by the Centre National d'Etudes Spatiales (CNES). Both versions of LUVOIR are also designed to be serviceable and upgradeable. We will also provide a summary of the LUVOIR technology development program, which identifies critical enabling technologies, enhancing technologies, and a development plan to mature those technologies to TRL 6.

technology↗

High-Resolution Spectroscopy of Titan with SOFIA/EXES

We present the first observation of Titan with the high resolution Echelon cross-Echelle Spectrograph(EXES) instrument on the Stratospheric Observatory for Infrared Astronomy (SOFIA, Fig. 1). These show clear detection of multiple spectral lines in the R-branch of the acetylene vibrational band at 13 m. These are compared to similar observations with the ground-based sister instrument TEXES (Texas Echelon cross-Echelle Spectrograph) on the IRTF(Infrared Telescope Facility), showing that EXES will have access to an enlarged spectral range as expected, through reduced atmospheric opacity. In future EXES will be used to complement TEXES for spectral line searches on Titan, geared to detect new molecular species, focusing on spectral regions that are inaccessible from the ground.

Nixon, Conor A.↗

The Star-Grazing Bodies in the HD 172555 System

Kiefer et al. reported the detection of infalling Ca II absorption in HD 172555, a member of the β Pictoris Moving Group (βPMG). We obtained HST Space Telescope Imaging Spectrograph and Cosmic Origins Spectrograph spectroscopy of this star at 2 epochs separated by a week, and we report the discovery of infalling gas in resonant transitions of Si III and IV, C II and IV, and neutral atomic oxygen. Variable absorption is seen in the C II transitions and is optically thick, with covering factors which range between 58% and 68%, similar to features seen in β Pictoris. The O I spectral profile resembles that of C II, showing a strong low-velocity absorption to +50 km/s in the single spectral segment obtained during orbital night, as well as what may be higher-velocity absorption. Studies of the mid-IR spectrum of this system have suggested the presence of silica. The O I absorption differs from that seen in Si III, suggesting that the neutral atomic oxygen does not originate in SiO dissociation products but in a more volatile parent molecule such as CO.

C. A. Grady↗

A Chromaticity Analysis and PSF Subtraction Techniques for SCExAO/CHARIS Data

We present an analysis of instrument performance using new observations taken with the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) instrument and the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. In a correlation analysis of our data sets (which use the broadband mode covering the J band through the K band in a single spectrum), we find that chromaticity in the SCExAO/CHARIS system is generally worse than temporal stability. We also develop a point-spread function (PSF) subtraction pipeline optimized for the CHARIS broadband mode, including a forward modeling-based exoplanet algorithmic throughput correction scheme. We then present contrast curves using this newly developed pipeline. An analogous subtraction of the same data sets using only the H-band slices yields the same final contrasts as the full JHK sequences; this result is consistent with our chromaticity analysis, illustrating that PSF subtraction using spectral differential imaging (SDI) in this broadband mode is generally not more effective than SDI in the individual J, H, or K bands. In the future, the data processing framework and analysis developed in this paper will be important to consider for additional SCExAO/CHARIS broadband observations and other ExAO instruments which plan to implement a similar integral field spectrograph broadband mode.

Benjamin L. Gerard↗

No Clear, Direct Evidence for Multiple Protoplanets Orbiting LkCa 15: LkCa 15 bcd are Likely Inner Disk Signals

Two studies utilizing sparse aperture-masking (SAM) interferometry and Hα differential imaging have reported multiple Jovian companions around the young solar-mass star, LkCa 15 (LkCa 15 bcd): thefirst claimed direct detection of infant, newly formed planets (“protoplanets”). We present new near-infrared direct imaging/spectroscopy from the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system coupled with Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) integral field spectrograph and multi-epoch thermal infrared imaging from Keck/ NIRC2 of LkCa 15 at high Strehl ratios. These data provide the first direct imaging look at the same wavelengths and in the same locations where previous studies identified the LkCa 15 protoplanets,and thus offer the first decisive test of their existence.The data do not reveal these planets. Instead,we resolve extended emission tracing adust disk with a brightness and location comparable to that claimed for LkCa 15 bcd. Forward-models attributing this signal to orbiting planets are inconsistent with the combined SCExAO/CHARIS and Keck/NIRC2 data. An inner disk provides a more compelling explanation for the SAM detections and perhaps also the claimed Hα detection of LkCa 15 b. We conclude that there is currently no clear, direct evidence for multiple protoplanets orbiting LkCa 15, although the system likely contains at least one unseen Jovian companion. To identify Jovian companions around LkCa 15 from future observations, the inner disk should be detected and its effect modeled, removed, and shown to be distinguishable from planets. Protoplanet candidates identified from similar systems should likewise be clearly distinguished from disk emission through modeling.