Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Threat Agnostic Virulence Assessment of Pathogens

Virulence assessment of new, emerging, and engineered pathogens is critical to mounting an appropriate response to a biothreat agent. The capacity of the pathogen to colonize human and harm tissues must be characterized to understand pathogenicity pathways and optimize diagnosis and treatment of resulting disease. Respiratory pathogens are of interest because they can have high transmissibility rates, as observed with the SARS-CoV-2 virus, the causative agent of Covid-19. Current technologies are insufficient to assess threats due to their reliance on systems with only one cell type and on sequencing the pathogen. However, it is known that sequence is not an accurate predictor of function, and sequencing can be unreliable for newly emerged or engineered pathogens. An ideal system would consist of relevant epithelial cell types and an assay sensitive enough to detect changes in host responses that do not rely on DNA sequencing. We chose a system consisting of host lung epithelial cells that can be used to assess the virulence of unknown respiratory pathogens. We interrogated pathogens using this model and assess features of pathogenicity. Our objective is to leverage PNNLs strengths in tissue engineering and proteomics capabilities to build a multiple reaction monitoring (MRM) or parallel reaction monitoring (PRM) liquid chromatography-tandem mass spectrometry assay for human host cell proteins whose abundance is influenced by infection. These responses can were then assessed for relative virulence using pathogen agnostic signatures. When confronted with a pathogen, cells activate dedicated signaling pathways, typically through phosphorylation of regulatory proteins and downstream activation of host cell networks.

59 BASIC BIOLOGICAL SCIENCES↗

Ditechnetium heptoxide revisited: Solid-state, gas-phase, and theoretical studies

Here, ditechnetium heptoxide was synthesized from the oxidation of TcO 2 with O 2 at 450 °C and characterized by single crystal X-ray diffraction (SCXRD), electron impact mass spectrometry (EI-MS) and theoretical methods. Refinement of the structure at 100 K indicates that Tc 2 O 7 crystallizes as a molecular solid in the orthorhombic space group Pbca (a = 7.312(3) Å, b = 5.562(2) Å, c = 13.707(5) Å, V = 557.5(3) Å 3 ). The Tc 2 O 7 molecule can be described as corner-sharing TcO4 tetrahedra (Tc---Tc = 3.698(1) Å and Tc-O Bri -Tc = 180.0°). The EI-MS spectrum of Tc 2 O 7 consists of both mononuclear and dinuclear species. The main dinuclear species in the gas-phase are Tc 2 O 7 (100%) and Tc 2 O 5 (56%), while the main mononuclear species are TcO 3 (33.9%) and TcO 2 (42.8%). The difference in the relative intensities of the M 2 O 5 (M = Tc, Re) fragments (1.7% for Re) indicate that these Group 7 elements exhibit different gas phase chemistry. The solid-state structure of Tc 2 O 7 was investigated by density functional theory (DFT) methods. The optimized structure of the Tc 2 O 7 molecule is in good agreement with the experimental one. Simulations indicate that the more favorable geometry for the Tc 2 O 7 molecule in the gas-phase is bent (Tc-O Bri -Tc = 156.5°), while linear (Tc-O Bri -Tc = 180.0°) is favored in the solid state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The impact of interfacial Si contamination on GaN-on-GaN regrowth for high power vertical devices

The development of gallium nitride (GaN) power devices requires a reliable selective-area doping process, which is difficult to achieve because of ongoing challenges associated with the required etch-then-regrow process. The presence of silicon (Si) impurities of unclear physical origin at the GaN regrowth interface has proven to be a major bottleneck. Furthermore, this paper investigates the origin of Si contamination at the epitaxial GaN-on-GaN interface and demonstrates an approach that markedly reduces its impact on device performance. An optimized dry-etching approach combined with UV-ozone and chemical etching is shown to greatly reduce the Si concentration levels at the regrowth interface, and a significant improvement in a reverse leakage current in vertical GaN-based p–n diodes is achieved.

36 MATERIALS SCIENCE↗

Theoretical investigation of the relative stability of Na{sup +}He{sub n} (n = 2–24) clusters: Many-body versus delocalization effects

The solvation of the Na{sup +} ion in helium clusters has been studied theoretically using optimization methods. A many-body empirical potential was developed to account for Na{sup +}–He and polarization interactions, and the most stable structures of Na{sup +}He{sub n} clusters were determined using the basin-hopping method. Vibrational delocalization was accounted for using zero-point energy corrections at the harmonic or anharmonic levels, the latter being evaluated from quantum Monte Carlo simulations for spinless particles. From the static perspective, many-body effects are found to play a minor role, and the structures obtained reflect homogeneous covering up to n = 10, followed by polyicosahedral packing above this size, the cluster obtained at n = 12 appearing particularly stable. The cationic impurity binds the closest helium atoms sufficiently to negate vibrational delocalization at small sizes. However, this snowball effect is obliterated earlier than shell completion, the nuclear wavefunctions of {sup 4}He{sub n}Na{sup +} with n = 5–7, and n > 10 already exhibiting multiple inherent structures. The decrease in the snowball size due to many-body effects is consistent with recent mass spectrometry measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE)

Uranium hexafluoride (UF6) is the uranium compound typically involved in uranium enrichment process. As the first line of defense against nuclear proliferation, accurate determinations of the uranium enrichment ratio in UF6 are critical for materials verification, accounting and safeguards. Shipping gaseous UF6 samples off-site for analysis with mass spectrometry is cumbersome and costly, and results are not available for some time (months). In-field UF6 enrichment assay has the potential to substantially reduce the time, logistics and expense of sample handling. At present, COMPUCEA is the only accepted method for UF6 enrichment assay in the field. Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE) is an all-optical (based on laser induced plasma emission) analytical technique intended for fieldable, accurate, precise and rapid UF6 enrichment assay. In its operation, laser induced plasma is created directly in the gaseous UF6 sample. Because different U isotopes emit at slightly different wavelengths, the isotopic information of the UF6 sample is inherently encoded in the atomic emission from the plasma. Isotopic emissions from 235U and 238U are measured simultaneously, which eliminate correlated noise from the laser induced plasma. Isotopic information of the UF6 sample can be extracted from the acquired spectrum with theoretical multi-variable non-linear spectral fitting. To date, advances made by the LISA-UE research team include optimization of the spectral window for direct gaseous UF6 enrichment assay with laser induced plasma, development of data reduction algorithms, and demonstrations of the LISA-UE technique with gaseous UF6 samples. In this presentation, the technical aspect of LISA-UE will be overviewed, the data reduction algorithm will be described, and performance of the technique will be discussed.

Chan, George↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing Families of Spectral Similarity Scores and Their Use Cases for Gas Chromatography–Mass Spectrometry Small Molecule Identification

Metabolomics provides a unique snapshot into the world of small molecules and the complex biological processes that govern the human, animal, plant, and environmental ecosystems encapsulated by the One Health modeling framework. However, this “molecular snapshot” is only as informative as the number of metabolites confidently identified within it. The spectral similarity (SS) score is traditionally used to identify compound(s) in mass spectrometry approaches to metabolomics, where spectra are matched to reference libraries of candidate spectra. Unfortunately, there is little consensus on which of the dozens of available SS metrics should be used. This lack of standard SS score creates analytic uncertainty and potentially leads to issues in reproducibility, especially as these data are integrated across other domains. In this work, we use metabolomic spectral similarity as a case study to showcase the challenges in consistency within just one piece of the One Health framework that must be addressed to enable data science approaches for One Health problems. Here, using a large cohort of datasets comprising both standard and complex datasets with expert-verified truth annotations, we evaluated the effectiveness of 66 similarity metrics to delineate between correct matches (true positives) and incorrect matches (true negatives). We additionally characterize the families of these metrics to make informed recommendations for their use. Our results indicate that specific families of metrics (the Inner Product, Correlative, and Intersection families of scores) tend to perform better than others, with no single similarity metric performing optimally for all queried spectra. This work and its findings provide an empirically-based resource for researchers to use in their selection of similarity metrics for GC-MS identification, increasing scientific reproducibility through taking steps towards standardizing identification workflows.

59 BASIC BIOLOGICAL SCIENCES↗

The TAMUTRAP facility: A Penning trap facility at Texas A&M University for weak interaction studies

The Texas A&M University Penning Trap (TAMUTRAP) facility aims to test the standard model of the electroweak interaction by measuring the β-ν correlation parameter, a βν , for β-delayed proton emitters in the atomic mass range 20 < A < 40. Precision measurements of this correlation parameter and, inextricably, the Fierz interference parameter, are a sensitive probe of physics beyond the standard model. Here, using off-line ion sources, the TAMUTRAP facility has been commissioned by demonstrating the ability to manipulate the trapped-ion motions as well as to perform precision mass measurements. Our novel cylindrical Penning trap – the world's largest – differs from typical designs in two key aspects: the electrode structure has an 180-mm inner diameter and an overall length of 334.89 mm leading to a uniquely small length/radius ratio l/r = 3.72; and we do not use the long end cap approximation, instead our short endcap electrodes are closed and capable of being placed at an arbitrary potential. This geometry is optimized for observing β-delayed proton decays, but is also well suited for other in-trap and post-trap precision decay experiments. In addition to presenting an overview of the TAMUTRAP facility, we demonstrate that our unique Penning trap is able to measure masses with a precision similar to typical trap designs.

47 OTHER INSTRUMENTATION↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Matrix Optical Absorption in UV-MALDI MS

In ultraviolet matrix-assisted laser desorption/ionization mass spectrometry (UV-MALDI MS) matrix compound optical absorption governs the uptake of laser energy, which in turn has a strong influence on experimental results. Despite this, quantitative absorption measurements are lacking for most matrix compounds. Furthermore, despite the use of UV-MALDI MS to detect a vast range of compounds, investigations into the effects of laser energy have been primarily restricted to single classes of analytes. We report the absolute solid state absorption spectra of the matrix compounds α-cyano-4-hydroxycinnamic acid (CHCA), para-nitroaniline (PNA), 2-mercaptobenzothiazole (MBT), 2,5-dihydroxybenzoic acid (2,5-DHB), and 2,4,6-trihydroxyacetophenone (THAP). The desorption/ionization characteristics of these matrix compounds with respect to laser fluence was investigated using mixed systems of matrix with either angiotensin II, PC(34:1) lipid standard, or haloperidol, acting as representatives for typical classes of analyte encountered in UV-MALDI MS. The first absolute solid phase spectra for PNA, MBT, and THAP are reported; additionally, inconsistencies between previously published spectra for CHCA are resolved. In light of these findings, suggestions are made for experimental optimization with regards to matrix and laser wavelength selection. The relationship between matrix optical cross-section and wavelength-dependant threshold fluence, fluence of maximum ion yield, and R, a new descriptor for the change in ion intensity with fluence, are described. A matrix cross-section of 1.3 × 10{sup –17} cm{sup –2} was identified as a potential minimum for desorption/ionization of analytes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Improved Method for Extracting, Sorting, and AMS Dating of Pollen Concentrates From Lake Sediment

High-resolution chronologies are crucial for paleoenvironmental reconstructions, and are particularly challenging for lacustrine records of terrestrial paleoclimate. Accelerator Mass Spectrometry (AMS) radiocarbon measurement of terrestrial macrofossils is the most common technique for building age models for lake sediment cores, but relies on the presence of terrestrial macrofossils in sediments. In the absence of sufficient macrofossils, pollen concentrates represent a valuable source of dates for building high-resolution chronologies. However, pollen isolation and dating may present several challenges, as has been reported by different authors in previous work over the last few decades. Here we present an improved method for extracting, purifying and radiocarbon-dating pollen concentrates using flow cytometry to improve the extraction efficiency and the purity of the pollen concentrates. Overall, the nature of the sediments and the abundance of the pollen represent major considerations in obtaining enough pollen grains and, consequently, enough carbon to be dated. Further, the complete separation of pollen from other forms of organic matter is required to ensure the accuracy of the dates. We apply the method to surface samples and sediment cores recovered from two contrasting lake basins on the eastern side of the Sierra Nevada (California), and describe the variations that may be used to optimize pollen preparation from a variety of sediments.

58 GEOSCIENCES↗

Use of in Situ Synchrotron Techniques to Probe the Oxidized Surface of Molybdenum Nitride Oxygen Reduction Electrocatalysis

The development of active and stable earth-abundant catalysts for the oxygen reduction reaction (ORR) is needed for widespread, economic development of fuel cell technologies. Designing and optimizing these non-platinum group metals is challenging, however, because they are susceptible to composition and structure changes, including dissolution, oxidation, and corrosion, both in air and under reaction conditions. To identify the active surface, and thus understand the properties that affect activity, the catalyst surface must be characterized in situ. Herein, we utilize a grazing incidence electrochemical cell to investigate in situ composition and morphology changes of a molybdenum nitride (Mo-N) thin film catalyst using grazing incidence x-ray absorption spectroscopy (GI-XAS) and x-ray reflectivity (XRR). In rotating ring disk electrode measurements, we find that the activity, selectivity, stability, and capacitance of the Mo-N catalyst is dependent on the maximum potential to which it has been exposed. Specifically, the overpotential required to reach -2 mA cm-2geo decreases by over 90 mV when the maximum potential is increased from 0.3 to 0.8 V vs RHE (Figure 1). Because the Mo-N oxidizes rapidly in air, ex situ characterization methods including x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry can provide only limited insight into these in situ catalyst changes. Using in situ GI-XAS measurements at applied potentials between 0.3 and 0.9 V vs RHE, however, we are able to determine that the surface of the film oxidizes and becomes more amorphous when exposed to increasingly higher potentials (Figure 1). Furthermore, the surface remains oxidized on the order of several hours when returned to "ORR relevant potentials" (< 0.6 V vs RHE), indicating that this surface-oxidized nitride is the active surface for ORR. Using in situ XRR measurements, we find that there is no change in surface roughness at potentials below 0.7 V vs RHE, but the film roughens significantly at 0.8 V vs RHE, correlating with ex situ measurements of Mo dissolution at this potential (Figure 1). We therefore conclude that the intrinsic activity of the Mo-N catalyst increases when exposed to potentials up to 0.7 V vs RHE, while above that potential activity enhancements are due to the exposure of more active sites through dissolution. The in situ electrochemical surface-sensitive x-ray characterization as used here is a promising methodology for understanding and leveraging surface dynamics to improve the performance of non-traditional catalysts.

Kreider, Melissa↗

Addressing Critical Problems in Materials Science Through Multiscale and Multimode Characterization (Project 1); Characterization and Optimization of Novel Triple-Conducting Oxide Materials for Energy Applications (Project 2) (CRADA Final Report)

PROJECT 1: Address critical problems in materials science and simultaneously advance the state-of-the-art in multiscale and multimode characterization using the combined advanced analytical capabilities and expertise of Colorado School of Mines (CSM) and the National Renewable Energy Laboratory (NREL). The primary effort of the Phase I of this CRADA is to establish the International Center for Multiscale Characterization using shared resources at both NREL and CSM. Phase II will focus on capability development and marketing, choosing candidate materials science issues in the areas of structure imaging, chemical composition mapping, and correlating properties and performance of materials for impact in energy-related, environmental and critical materials areas. The CRADA will be modified to include specific topics of concern in materials science to industry member partners. Advanced analytical capabilities and expertise at CSM and NREL will be used to advance materials understanding and performance through characterization of multiscale phenomena including structural imaging, chemical composition mapping, and other techniques correlating properties and performance of materials. PROJECT 2: As part of the International Center for Materials Characterization, work under Modification #1 will be led by Colorado School of Mines (CSM), working in collaboration with NREL staff to mentor and advise CSM postdoctoral researchers on set up of diffusion annealing experiments. The purpose of the modification is to provide for NREL staff to mentor and advise CSM postdoctoral researchers on set up of diffusion annealing experiments, including mentoring and advising the CSM-NREL team on proper Secondary Ion Mass Spectrometry (SIMS) data analysis as needed. SIMS measurements of 10-20 samples will be performed at NREL during the project duration.

08 HYDROGEN↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

Multi-matrix, dual polarity, tandem mass spectrometry imaging strategy applied to a germinated maize seed: toward mass spectrometry imaging of an untargeted metabolome

Mass spectrometry imaging (MSI) provides high spatial resolution information that is unprecedented in traditional metabolomics analyses; however, the molecular coverage is often limited to a handful of compounds and is insufficient to understand overall metabolomic changes of a biological system. Here, we propose an MSI methodology to increase the diversity of chemical compounds that can be imaged and identified, in order to eventually perform untargeted metabolomic analysis using MSI. We use the desorption/ionization bias of various matrixes for different metabolite classes along with dual polarities and a tandem MSI strategy. The use of multiple matrixes and dual polarities allows us to visualize various classes of compounds, while data-dependent MS/MS spectra acquired in the same MSI scans allow us to identify the compounds directly on the tissue. In a proof of concept application to a germinated corn seed, a total of 166 unique ions were determined to have high-quality MS/MS spectra, without counting structural isomers, of which 52 were identified as unique compounds. According to an estimation based on precursor MSI datasets, we expect over five hundred metabolites could be potentially identified and visualized once all experimental conditions are optimized and an MS/MS library is available. Finally, metabolites involved in the glycolysis pathway and tricarboxylic acid cycle were imaged to demonstrate the potential of this technology to better understand metabolic biology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of Na on Cu-K-In-Se thin film growth

Co-evaporation of Cu-KF-In-Se was performed on substrates with varied Na supply. Compositions of interest for photovoltaic absorbers were studied, with ratios of (K + Cu)/In ~ 0.85 and K/(K + Cu) ~ 0-0.57. Bare soda-lime glass (SLG) substrates had the highest Na supply as measured by secondary ion mass spectrometry, while SLG/Mo and SLG/SiO 2 /Mo substrates led to 3x and 3000x less Na in the growing film, respectively. Increased Na supply favored Cu 1-x K x InSe 2 (CKIS) alloy formation as proven by X-ray diffraction (XRD), while decreased Na supply favored the formation of CuInSe 2 + KInSe 2 mixed-phase films. Scanning electron microscopy and energy dispersive X-ray spectroscopy revealed the KInSe 2 precipitates to be readily recognizable planar crystals. Extrinsic KF addition during film growth promoted diffusion of Na out from the various substrates and into the growing film, in agreement with previous reports. Time-resolved photoluminescence showed enhanced minority carrier lifetimes for films with moderate K compositions (0.04 < K/(K + Cu) < 0.14) grown on SLG/Mo. Due to the relatively high detection limit of KInSe 2 by XRD and the low magnitude of chalcopyrite lattice shift for CKIS alloys with these compositions, it is unclear if the lifetime gains were associated with CKIS alloying, minor KInSe 2 content, or both. The identified Na-K interdependency can be used to engineer alkali metal bonding in Cu(In,Ga)(Se,S) 2 absorbers to optimize both initial and long-term photovoltaic power generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗