Search NASA⌕ Search

SEARCH · Search NASA

Results for “squids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Magnetic Compton Scattering Study of Li-Rich Battery Materials

The redox process in a lithium-ion battery occurs when a conduction electron from the lithium anode is transferred to the redox orbital of the cathode. Understanding the nature of orbitals involved in anionic as well as cationic redox reactions is important for improving the capacity and energy density of Li-ion batteries. In this connection, we have obtained magnetic Compton profiles (MCPs) from the Li-rich cation-disordered rock-salt compound LixTi0.4Mn0.4O2 (LTMO). The MCPs, which involved the scattering of circularly polarized hard X-rays, are given by the momentum density of all the unpaired spins in the material. The net magnetic moment in the ground state can be extracted from the area under the MCP, along with a SQUID measurement. Our analysis gives insight into the role of Mn 3d magnetic electrons and O 2p holes in the magnetic redox properties of LTMO.

Suzuki, Kosuke (ORCID:0000000317110604)↗

Searches for Electric Dipole Moments—Overview of Status and New Experimental Efforts

Searches for permanent electric dipole moments (EDMs) of fundamental particles, atoms and molecules are promising experiments to constrain and potentially reveal beyond Standard Model (SM) physics. A non-zero EDM is a direct manifestation of time-reversal (T) violation, and, equivalently, violation of the combined operation of charge-conjugation (C) and parity inversion (P). Identifying new sources of CP violation can help to solve fundamental puzzles of the SM, e.g., the observed baryon-asymmetry in the Universe. Theoretical predictions for magnitudes of EDMs in the SM are many orders of magnitude below current experimental limits. However, many theories beyond the SM require larger EDMs. Experimental results, especially when combined in a global analysis, impose strong constraints on CP violating model parameters. Including an overview of EDM searches, I will focus on the future neutron EDM experiment at TRIUMF (Vancouver). For this effort, the TUCAN (TRIUMF Ultra Cold Advanced Neutron source) collaboration is aiming to build a strong, world leading source of ultra cold neutrons (UCN) based on a unique combination of a spallation target and a superfluid helium UCN converter. Another focus will be the search for an EDM of the diamagnetic atom 129 Xe using a 3 He comagnetometer and SQUID detection. The HeXeEDM collaboration has taken EDM data in 2017 and 2018 in the magnetically shielded room (BMSR-2) at PTB Berlin.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

Abstract We report on the design and performance of the B icep3 instrument and its first three-year data set collected from 2016 to 2018. B icep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. B icep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μ K CMB s and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μ K arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μ K arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Synthesis and characterization of monodisperse magnetite hollow microspheres

Monodisperse hollow magnetite microspheres were successfully synthesized by an one-step process through a template-free hydrothermal approach employing simultaneously a mixture of FeCl 3 ·6H 2 O and ferrocene as precursor and a propylene glycol-isopropanol mixture as solvent. The morphologies and properties of the magnetite microspheres were characterized by X-ray diffraction (XRD), Raman and infrared spectroscopy, field emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), adsorption of nitrogen (BET method) and SQUID magnetometry. The results show that the microspheres consist of a single crystalline phase of magnetite. Furthermore, the size and the internal hollow of the microspheres depend on the temperature of growth and can be tuned by modifying the synthesis conditions.

36 MATERIALS SCIENCE↗

The biology of cartilage. II

Squid head cartilage properties in terms of light and electron microscopic appearance, amino acid composition and X ray diffraction

Person, P.↗

The effect of membrane parameters on the properties of the nerve impulse.

The effect of varying some membrane parameters is explored, basing the investigation on computer simulation of the Hodgkin-Huxley equations for the squid giant axon, including variations in the membrane capacitance, conductances, and the rate constants. It is shown that by reducing the degree of regeneration in the excitable membrane, the character of the nerve signal can be smoothly changed from that of the axonal spike to essentially electrotonic spread, with all gradations in between. The reduction in the degree of regeneration can most simply be brought about by a decrease in the density of active membrane patches.

Sabah, N. H.↗

Improvements of a magnetic monopole detector

Modifications to our previously described detector of magnetic monopoles resulting in substantial improvements in performance have been made. The sensitivity has been increased a factor of 35 by using a sensitive magnetometer (SQUID) to measure changes in current. The modifications, new measurement techniques, and implications for past and future experiments are described.

Eberhard, P. H.↗

A high accuracy gyroscope readout test facility for the relativity gyroscope experiment

An apparatus is under construction for ground-based testing of a gyroscope system to be used in a satellite test of general relativity. The immediate goal is a readout capable of measuring the direction of the gyroscope spin axis to an angular resolution of one arcsecond over a limited range. A combination of SQUID magnetometers and persistent current loops are used to measure the London moment of the spinning superconducting rotor levitated electrostatically. To obtain a trapped flux signal in the gyroscope sufficiently smaller than the London moment signal, the apparatus makes use of a new magnetic field shielding technique for obtaining large superconductor shielded regions below 0.1 millionth of a Gauss.

Cabrera, B.↗

Superconducting bearings for application in cryogenic experiments in space

Linear superconducting magnetic bearings suitable for use in a proposed orbital equivalence principle experiment and for general application in space were developed and tested. Current flows in opposite directions in adjacent superconducting wires arranged parallel to the axis of a cylinder. This configuration provides maximum stiffness radially while allowing the test mass to move freely along the cylinder axis. In a space application, the wires are extended to cover the entire perimeter of the cylinder: for the earth-based tests it was desirable to use only the bottom half. Control of the axial position of the test mass is by small control coils which may be positioned inside or outside the main bearing. The design is suitable for application to other geometries where maximum stiffness is desired. A working model scaled to operate in a 1-g environment was perfected approximate solutions for the bearings were developed. A superconducting transformer method of charging the magnets for the bearing, and a position detector based on a SQUID magnetometer and associated superconducting circuit were also investigated.

Everitt, C. W. F.↗

Development of a London moment readout for a superconducting gyroscope

A gyroscope for verifying certain predictions of General Relativity is under development at Stanford. A method of measuring the gyroscope orientation based on the use of the London moment and a SQUID magnetometer is described. It is estimated that the required sensitivity of 1 milliarc-sec can be achieved in a bandwidth of 2.5 times 10 to the -6th Hz.

Anderson, J. T.↗

The design and evaluation of superconducting connectors

The development of a superconducting connector for superconducting circuits on space flights is described. It is proposed that such connectors be used between the superconducting readout loop and the SQUID magnetometer in the Gravity Probe B experiment. Two types of connectors were developed. One type employs gold plated niobium wires making pressure connections to gold plated niobium pads. Lead-plated beryllium-copper spring contacts can replace the niobium wires. The other type is a rigid solder or weld connection between the niobium wires and the niobium pads. A description of the methods used to produce these connectors is given and their performance analyzed.

Payne, J. E.↗

Transonic wind-tunnel investigation of the Galileo Probe parachute configuration

Wind-tunnel tests have been made of 1/4-scale and 1/2-scale models of the Galileo Probe conical ribbon-parachute at flight conditions. For the Galileo mission, the parachute is deployed behind a blunt shape at transonic speed. The investigation was initiated to verify the solutions to the delayed main-parachute opening with squidding that was observed in the 1982 Galileo Probe system balloon drop test. In addition to varying model scale, the forebody shape, angle of attack, dynamic pressure, Mach number, and canopy trailing distance behind the forebody were varied to determine their effect on parachute performance. Both steady-state and deployment tests were conducted. Parachute drag was measured and was seen to degrade severely at canopy trailing distances of 5.5 and 7 forebody diameters. Performance was shown to be good at the trailing distances of 9 and 11 diameters. A second balloon drop test demonstrated the desired parachute performance at the system level.

Corridan, R. E.↗

Superconducting gyroscope research

Four basic areas of research and development of superconducting gyroscopes are studied. Chapter 1 studies the analysis of a SQUID readout for a superconducting gyroscope. Chapter 2 studies the dependence of spin-up torque on channel and gas properties. Chapter 3 studies the theory of super fluid plug operation. And chapter 4 studies the gyro rotor and housing manufacture.

Hendricks, J. B.↗

Cryogenic Equivalence Principle Experiment

The purpose of this project is to test the equivalence of inertial and passive gravitational mass in an Earth-orbiting satellite. A ground-based experiment is now well developed. It consists of comparing the motions of two cylindrical test masses suspended in precision superconducting magnetic bearings and free to move along the horizontal (axis) direction. The masses are made of niobium and lead-plated aluminum. A position detector based on a SQUID magnetometer measures the differential motion between the masses. The periods of the masses are matched by adjustment of the position detector until the system is insensitive to common mode signals, and so that the experiment is less sensitive to seismic vibration. The apparatus is contained in a twelve inch helium dewar suspended in a vibration isolation stand. The stand achieves 30 db isolation from horizontal motions between 0.1 and 60 Hz, by simulating the motion of a 200 meter long pendulum with an air bearing. With this attenuation of seismic noise and a common mode rejection ratio of 10 to the 5th power in the differential mode, the ground based apparatus should have a sensitivity to equivalence principle violations of one part in 10 to the 13th power; the satellite version might have a sensitivity of one part in 10 to the 17th power.

Everitt, C. W. F.↗

Design of Cryocoolers for Microwatt Superconducting Devices

The primary applications of the cryocoolers are for cooling various Josephson devices such as SQUID magnetometers and amplifiers, voltage standards, and microwave mixers and detectors. The common feature of these devices is their extremely low inherent bias power requirement, of the order of 10/1 W per junction. This provides the possibility of designing compact, low-power cryocoolers for these applications. Several concepts were explored and a number of laboratory model cryocoolers were built. These include low-power nonmagnetic regenerative machines of the Stirling or Gifford-McMahon type, three or four-stage Joule-Thomson machines, liquid-helium dewars with integral small cryocoolers to reduce the evaporation rate, and liquid-helium dewars with integral continuously or intermittently operated small helium liquefiers to permit operation of cryogenic devices for indefinite time periods.

Zimmerman, J. E.↗

Carbon isotope evidence for a magmatic origin for Archaean gold-quartz vein ore deposits

Sediments from three sites in the Santa Barbara Basin were examined with a 160X power light microscope and TEM equipment to characterize the magnetostatic bacteria (MB) in the samples. Both the free magnetite and the crystals in the MB in the samples had lengths from 40-60 nm in length and increased in size from one end to the next. An intact magnetosome was also observed. Scanning the sediments with saturation isothermal remanent magnetization (SIRM) and altering field demagnetization techniques using a SQUID magnetometer yielded coercivity spectra which showed that the primary remanence carrier in the sediments was single domain magnetite. Although it is expected that the predominance of the bacterial magnetite component will decrease with depth in the open ocean basin, single-domain bacteria as old as 50 Myr have been observed in oceanic sediments.

Burrows, D. R.↗

Cryogenic optical systems and instruments II; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1986

The topics of the present conference encompass cryogenic optical system design considerations, cryogenic instruments and their components, the design and performance of cryogenic dewars for space, and technologies supporting cryogenic systems and instruments. Attention is given to the Space IR Telescope Facility (SIRTF) observatory's design and on-orbit servicing, hardware development for the Gravity Probe-B program, the multiband imaging photometer aboard SIRTF, and the SIRTF wide field, diffraction-limited array camera. Also discussed are the cryogenic star-tracking telescope for Gravity Probe-B, a balloon-borne spectrometer for measurement of lower stratospheric trace constituents, the primary mirror support system design for a cryogenic space telescope, and the SQUID readout and ultralow magnetic fields of Gravity Probe-B.

Melugin, Ramsey K.↗

Superconducting thin-film gyroscope readout for Gravity Probe-B

The high-resolution gyroscope readout system for the Stanford Gravity Probe-B experiment, whose purpose is to measure two general relativistic precessions of gyroscopes in earth orbit, is described. In order to achieve the required resolution in angle (0.001 arcsec), the readout system combines high-precision mechanical fabrication and measurement techniques with superconducting thin-film technology, ultralow magnetic fields, and SQUID detectors. The system design, performance limits achievable with current technology, and the results of fabrication and laboratory testing to date are discussed.

Lockhart, James M.↗