Search NASA⌕ Search

SEARCH · Search NASA

Results for “system testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Determination of Thermoelectric Module Efficiency A Survey

The development of thermoelectrics (TE) for energy conversion is in the transition phase from laboratory research to device development. There is an increasing demand to accurately determine the module efficiency, especially for the power generation mode. For many thermoelectrics, the figure of merit, ZT, of the material sometimes cannot be fully realized at the device level. Reliable efficiency testing of thermoelectric modules is important to assess the device ZT and provide the end-users with realistic values on how much power can be generated under specific conditions. We conducted a general survey of efficiency testing devices and their performance. The results indicated the lack of industry standards and test procedures. This study included a commercial test system and several laboratory systems. Most systems are based on the heat flow meter method and some are based on the Harman method. They are usually reproducible in evaluating thermoelectric modules. However, cross-checking among different systems often showed large errors that are likely caused by unaccounted heat loss and thermal resistance. Efficiency testing is an important area for the thermoelectric community to focus on. A follow-up international standardization effort is planned.

efficiency↗

Formulation of an experimental substructure model using a Craig-Bampton based transmission simulator

An experimental–analytical substructuring is attractive when there is motivation to replace one or more system subcomponents with an experimental model. This experimentally derived substructure can then be coupled to finite element models of the rest of the structure to predict the system response. The transmission simulator method couples a fixture to the component of interest during a vibration test in order to improve the experimental model for the component. The transmission simulator is then subtracted from the tested system to produce the experimental component. This method reduces ill-conditioning by imposing a least squares fit of constraints between substructure modal coordinates to connect substructures, instead of directly connecting physical interface degrees of freedom. This paper presents an alternative means of deriving the experimental substructure model, in which a Craig–Bampton representation of the transmission simulator is created and subtracted from the experimental measurements. The corresponding modal basis of the transmission simulator is described by the fixed-interface modes, rather than free modes that were used in the original approach. Moreover, these modes do a better job of representing the shape of the transmission simulator as it responds within the experimental system, leading to more accurate results using fewer modes. The new approach is demonstrated using a simple finite element model based example with a redundant interface.

42 ENGINEERING↗

Permeability scaling relationships of volcanic tuff from core to field scale measurements

A recent chemical explosive test in P-Tunnel at the Nevada National Security Site, Nevada, USA, was conducted to better understand how signals propagate from explosions in the subsurface. A primary signal of interest is the migration of gases that can be used to differentiate chemical from nuclear explosions. Gas migration is highly dependent on the rock permeability which is notoriously difficult to determine experimentally in the field due to a potentially large dependence on the scale over which measurements are made. Here, we present pre-explosion permeability estimates to characterize the geologic units surrounding the recent test. Permeability measurements were made at three scales of increasing size: core samples (≈2 cm), borehole packer system tests (≈1 m), and a pre-shot cavity pressurization test (> 10 m) across ten tuff units. Permeability estimates based on core measurements showed little difference from borehole packer tests. However, permeability in most rock units calibrated from cavity pressurization tests resulted in higher permeability estimates by up to two orders of magnitude. Here, we demonstrate that the scale of the measurement significantly impacts the characterization efforts of hydraulic properties in volcanic tuff, and that local-scale measurements (< 10 m scale) do not incorporate enough heterogeneity to accurately predict field-scale flow and mass transport.

Environmental sciences↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RE-INTEGRATE EMT Simulation Tool: Input Data Processing Layer for Bulk Power System

This paper introduces an advanced input data processing layer for EMT simulations of large-scale bulk power systems. The paper proposes two versions of the RE-INTEGRATE EMT simulation tool, RE-INTEGRATE Gen-0 and RE-INTEGRATE Gen-1, which are developed to enhance simulation generalizability, scalability, and accuracy. The framework leverages a generic class design for components to incorporate linear equations, which are generated by discretizing the Differential-Algebraic Equations (DAEs) that represent the dynamics of the components. In addition, the framework employs a parsing algorithm that parses a power system’s raw and dyr files to generate a connectivity graph which is then traversed to form the overall system’s dynamics. The proposed input data processing layer is used to simulate the IEEE 39-bus test system. The obtained results demonstrate the framework’s capability to achieve simulation scalability and accuracy. Further, the results indicate that EMT simulations performed using the proposed automations can effectively handle complex grid configurations.

Mishra, Rahul [ORNL] (ORCID:0000000328205932)↗

Flue gas cleanup using the Moving-Bed Copper Oxide Process

The use of copper oxide on a support had been envisioned as a gas cleanup technique to remove sulfur dioxide (SO{sub 2}) and nitric oxides (NO{sub x}) from flue gas produced by the combustion of coal for electric power generation. In general, dry, regenerable flue gas cleanup techniques that use a sorbent can have various advantages, such as simultaneous removal of pollutants, production of a salable by-product, and low costs when compared to commercially available wet scrubbing technology. Due to the temperature of reaction, the placement of the process into an advanced power system could actually increase the thermal efficiency of the plant. The Moving-Bed Copper Oxide Process is capable of simultaneously removing sulfur oxides and nitric oxides within the reactor system. In this regenerable sorbent technique, the use of the copper oxide sorbent was originally in a fluidized bed, but the more recent effort developed the use of the sorbent in a moving-bed reactor design. A pilot facility or life-cycle test system was constructed so that an integrated testing of the sorbent over absorption/regeneration cycles could be conducted. A parametric study of the total process was then performed where all process steps, including absorption and regeneration, were continuously operated and experimentally evaluated. The parametric effects, including absorption temperature, sorbent and gas residence times, inlet SO{sub 2} and NO{sub x} concentration, and flyash loadings, on removal efficiencies and overall operational performance were determined. Although some of the research results have not been previously published because of previous collaborative restrictions, a summary of these past findings is presented in this communication. Additionally, the potential use of the process for criteria pollutant removal in oxy-firing of fossil fuel for carbon sequestration purposes is discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Washington Clean Energy Fund: Energy Storage System Consolidated Performance Test Results

This report provides an overview of test results for four energy storage systems funded under the Washington Clean Energy Fund deployed at three utilities in Washington State. Integration of energy storage into the U.S. grid has been gathering momentum across the industry, especially as penetration of power generated by renewable resources increases. Several states have storage procurement targets to deal with a variety of issues, such as afternoon total system load ramping requirements, frequency regulation/control, and integration power generated from by renewable resources. This report presents the performance test results for battery energy storage systems (BESS) funded by the Washington Clean Energy Fund (CEF) 1 Program ($\$$14.3 million in state funding supporting a total investment of $\$$43 million). For each project, the technical attributes of the BESS were tested, defined, and evaluated in detail. These projects were funded jointly by Avista, the Snohomish Public Utility District (SnoPUD), Puget Sound Energy (PSE), the Washington CEF, and the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Two-Phase Terry Turbine Nozzle Models for RCIC Off-Design Operation Conditions

This report presents the effort to extend the single-phase analytical Terry turbine model to cover two-phase off-design conditions. The work includes: (1) adding well-established two-phase choking models – the Isentropic Homogenous Equilibrium Model (IHEM) and Moody’s model, and (2) theoretical development and implementation of a two-phase nozzle expansion model. The two choking models provide bounding cases for the two-phase choking mass flow rate. The new two-phase Terry turbine model uses the choking models to calculate the mass flow rate, the critical pressure at the nozzle throat, and steam quality. In the divergent stage, we only consider the vapor phase with a similar model for the single-phase case by assuming that the liquid phase would slip along the wall with a much slower speed and will not contribute the impulse on the rotor. We also modify the stagnation conditions according to two-phase choking conditions at the throat and the cross-section areas for steam flow at the nozzle throat and at the nozzle exit. The new two-phase Terry turbine model was benchmarked with the same steam nozzle test as for the single-phase model. Better agreement with the experimental data is observed than from the single-phase model. We also repeated the Terry turbine nozzle benchmark work against the Sandia CFD simulation results with the two-phase model for the pure steam inlet nozzle case. The RCIC start-up tests were simulated and compared with the single-phase model. Similar results are obtained. Finally, we designed a new RCIC system test case to simulate the self-regulated Terry turbine behavior observed in Fukushima accidents. In this test, a period inlet condition for the steam quality varying from 1 to 0 is applied. For the high quality inlet period, the RCIC system behaves just like the normal operation condition with a high pump injection flow rate and a nominal steam release rate through the turbine, with the net addition of water to the primary system; for the low quality inlet period, the RCIC turbine shaft work dramatically decreases and results in a much reduced pump injection flow rate, and the mixture flow rate through the turbine increases due to the high liquid phase flow rate. The net effect for this period is net removal of coolant from the primary loop. With the periodic addition and removal of coolant to the primary loop, the self-regulation mode of the RCIC system can be maintained for a quite long time. Both the IHEM and Moody’s models generate similar phenomena; however noticeable differences can be observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Maximizing the Benefits of Volt/VAR Optimization in the Presence of Community Energy Storage

This paper reports on the need for coordinating smart grid volt/volt-ampere reactive (VAR) control (VVC) and community energy storage (CES) to maximize the benefits of both approaches. It addresses a key application of volt/VAR optimization (VVO): the conservation of voltage reduction (CVR). The lack of coordination among network controls, such as VVO, and asset controls at the community battery storage system can lead to detrimental effects on grid operation. A smart grid-enabled VVC uses the VVO to perform the CVR operation. VVO can perform numerous tasks for advanced distribution management systems with coordination of the system operator. To achieve the optimal VVC solution, we use a particle swarm optimization driven VVO method. The test system has been simulated for two scenarios-during light loading and high loading condition-with and without the CES system. In both scenarios, the operation of CVR and CES have been performed considering different case studies. The outcomes of the simulated results demonstrate that significant improvement in peak load-demand reduction is achieved by the proposed VVC and CES system with reduced system losses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Great Lakes O shore Wind Project: Utility and Regional Integration Study

This project aims to identify transmission system upgrades needed to facilitate offshore wind projects as well as operational impacts of offshore generation on operation of the regional transmission system in the Great Lakes region. A simulation model of the US Eastern Interconnection was used as the test system as a case study for investigating the impact of the integration of a 1000MW offshore wind farm operating in Lake Erie into FirstEnergy/PJM service territory. The findings of this research provide recommendations on offshore wind integration scenarios, the locations of points of interconnection, wind profile modeling and simulation, and computational methods to quantify performance, along with operating changes and equipment upgrades needed to mitigate system performance issues introduced by an offshore wind project.

17 WIND ENERGY↗

Thermionic emission and energy conversion

This project worked on development of a transformative heat-to-electricity conversion device based on thermionic energy conversion. The research provided a unique opportunity to transform the thermionics technology of the 1950-1990s by applying modern materials and 21st century wafer-scale fabrication methods. Research was conducted to further development of a thermionic energy converter based on modern microfabrication and new low work function anode materials that can surpass all other forms of direct heat-to-electricity conversion. This project completed the following goals: (1) Developed components for use in thermionic energy converters and electron emission devices, including electrode materials for electron emission and electron absorption with ultimate work functions below 5 eV; (2) Designed and fabricated thermionic devices for energy conversion and electron emission based on the components developed in (1); (3) Engineered test systems to characterize electronic, thermal, and mechanical properties of thermionic devices and electron emitters and their components, and test devices and components designed and fabricated in (1) and (2); and (4) Developed theoretical modeling capabilities in support of these technical objectives.

36 MATERIALS SCIENCE↗

ANALYSIS OF COMMUNICATION PERFORMANCE DEGRADATION OF THE RADIATION TRANSPORT CODE PIDOTS ON HIGH-UTILIZATION, MULTI-USER HPC SYSTEMS

The PIDOTS radiation transport code implements a spatially decomposed Integral Transport Matrix Method (ITMM) solver, which is intended to fully utilize the capabilities of modern, massively parallel high-performance computing (HPC) systems. While the code shows promising results, there was also an unexpected loss of parallel efficiency on the test systems as the number of participating processors grew and the parallelization grain size got finer. We seek to identify and characterize the communication-latency based effects that contribute to this slowdown. Through the creation of a high-level, parameterized representation of the workload of the code, the communication methodology was identified as the likely reason. From there, low-level, InfiniBand communication performance data measured on the Falcon HPC at Idaho National Laboratory (INL) was used to produce a discrete-event model of the communication scheme. The data, as well as the model, show that infrequent, large spikes in send/receive latency drive an unexpectedly substantial increase in projected runtime of a code. Furthermore, these effects are more pronounced under the high-utilization, scattered-workload environment of Falcon. Based on results from the model, it can be shown that a high-communication volume, small message-size regime can easily lead to slowdowns of ~5-10x, when compared to ideal results, as the processor count increases.

97 MATHEMATICS AND COMPUTING↗

Small-Signal Stability Support from Dynamically Configurable Grid-Forming/Following Inverters for Distribution Systems: Preprint

As the penetration of inverter-based resources (IBRs) continues to increase in modern power systems, system stability is challenged by the insufficient inertia induced by IBRs; hence, there is a need to develop various methods to address the potential instabilities. In this paper, grid-forming (GFM) and grid-following (GFL) controls are implemented for inverters with flexible-mode transitions between them. The operation mode transition between GFM and GFL controls is adopted as an additional degree of control flexibility to adjust the small signal stability margin. Further, a holistic and detailed small signal model of the entire system with the dynamics from both synchronous generators (SGs) and IBRs is derived. The effectiveness of the proposed work in adjusting the system small signal stability margin is validated by conducting case studies with varying penetration levels of IBRs. A test system with one SG and five inverters was implemented in MATLAB/Simulink to demonstrate the effectiveness of the proposed approach. Index Terms - grid-following control, grid-forming control, operation mode transition, small-signal stability analysis

grid-following control↗

Method for separation of coal conversion products from oxygen carriers

Complete fuel conversion represents an important, but unresolved, aspect in Chemical Looping Combustion (CLC). Different system design approaches are currently being investigated to maximize carbon conversion in the fuel reactor. To achieve greater than ninety percent conversion of the fuel in “fluid-bed” type reducers will require that CLC systems be equipped with additional process equipment to ensure that unburnt fuel leaving the reducer is minimized. This paper presents results obtained from a laboratory test system simulating a char stripper design comprising two components; one for separating large char particles, based on material density differentials, and another for removing small char particles from the oxygen carrier (OC) leaving the reducer, based on elutriation. A test unit was designed, built and operated to identify optimum conditions for separating OC material from unburnt solid fuel – char. The results obtained are necessary for designing a high temperature unit operated at temperatures expected within a CLC system.

01 COAL, LIGNITE, AND PEAT↗

Representation and Impact of Water Head on Power System Planning and Operation

Representing water head information in power system model files, can provide a more realistic model of the system and thereby inform operation and planning personnel in the decision-making process. This article describes a procedure for modifying the power system model files (steady-state and dynamic) to represent water head information. Additionally, the impact of representing the water head on power system reliability studies including contingency analysis, cascading failure analysis and dynamic frequency response analysis has been investigated, using the modified power system models. This paper considers the detailed Western Electricity Coordination Council model during summer and winter conditions as the test system for the impact analysis. Results show that under reduced water head: 1) the number of critical voltage and branch flow violations increases; 2) chances of cascading failure and island formation increases; and 3) frequency nadir decreases as compared to those of the base cases where the water head information is not represented.

13 - HYDRO ENERGY↗

A Model for Hybrid Systems for Production Cost Modeling Studies Considering Ancillary Services

This paper introduces a model for simulating hybrid plants participating in energy and ancillary services for bulk power system studies. The model considers a hybrid plant comprised of a renewable energy source, a thermal power unit, a storage unit, fixed power loads, or any combination of these technologies. The model focuses on Production Cost Modeling (PCM) studies under the assumption of centralized dispatch. We present an example case study to illustrate the use of the model in a single-stage production cost model similar to those conducted by planning agencies. We explore the allocation of behind-the-meter ancillary services products and total energy participation to hybrid plant sub-assets and the resulting impacts on the system's ancillary service allocation. The model is implemented and simulated in a unit commitment problem in the RTS test system, which was modified to include a hybrid plant asset.

ancillary services↗