Search NASA⌕ Search

SEARCH · Search NASA

Results for “task programming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Hawai‘i National Marine Renewable Energy Center (HINMREC)

The Hawaii National Marine Renewable Energy Center (HINMREC) was established to facilitate the commercialization of wave energy converter (WEC) devices, and to accelerate development and testing of Ocean Thermal Energy Conversion (OTEC) technologies. Housed at the Hawaii Natural Energy Institute (HNEI) of the University of Hawaii (UH), this program started with execution of the contract between the US Department of Energy (DOE) and UH in March 2009, and activities ran through the end of the project in September 2019. The DOE tasked HINMREC with facilitating and accelerating the build-out of the Navy’s Wave Energy Test Site (WETS), the nation’s first grid-connected open water wave energy conversion test facility, located off Marine Corps Base Hawaii (MCBH) in Kaneohe, on the island of Oahu. WETS was expanded from an existing test berth at 30m water depth to include test berths at 60m and 80m water depths. In recognition of the high costs associated with at-sea testing and evaluation of WEC devices, it was deemed imperative that HINMREC seek ways to reduce costs to developers by providing key research support to these early-stage technologies. WETS and HINMREC’s support allowed development of wave energy technology by providing a testing infrastructure that allows technology developers to test, demonstrate and evaluate their WEC devices, and generate data in order to advance WEC designs toward commercial readiness. HINMREC’s roles have included support in the establishment of the full site, including of wave resource characterization and site survey, followed by the essential roles of independent WEC device power performance assessment and environmental monitoring in support of deployed pre-commercial WECs. This DOE-funded work transitioned effectively to continue Navy-funded tasks for OTEC development, and activities at WETS, now under Naval Facilities Engineering Command (NAVFAC) funding. A secondary objective in the establishment of HINMREC was to assist the private sector in moving OTEC systems beyond proof-of-concept to pre-commercialization, primarily focused on system and component engineering, and local and global investigations into the potential environmental impacts of OTEC systems. HINMREC was tasked with maintaining high-resolution models of ocean thermal resources and the potential sustainable power output of OTEC systems. Ongoing tests begun previously under Navy funding at the OTEC Heat Exchangers (HXs) Test Facility at the Natural Energy Laboratory of Hawaii Authority (NELHA), in Kona on Hawaii Island, have been continued to identify cost-effective aluminum alloys for use in OTEC systems operating in the corrosive marine environment.

16 TIDAL AND WAVE POWER↗

A UPC++ Actor Library and Its Evaluation On a Shallow Water Proxy Application

Programmability is one of the key challenges of Exascale Computing. Using the actor model for distributed computations may be one solution. The actor model separates computation from communication while still enabling their overlap. Each actor possesses specified communication endpoints to publish and receive information. Computations are undertaken based on the data available on these channels. We present a library that implements this programming model using UPC++, a PGAS library, and evaluate three different parallelization strategies, one based on rank-sequential execution, one based on multiple threads in a rank, and one based on OpenMP tasks. In an evaluation of our library using shallow water proxy applications, our solution compares favorably against an earlier implementation based on X10, and a BSP-based approach.

Pöppl, Alexander↗

Decontamination and Decommissioning Program of a Radiopharmaceuticals Production Facility - 17103

On May 2012, Best Medical Belgium (BMB) S.A., a manufacturer of pharmaceutical products located on the nuclear site of Fleurus, was declared bankrupt. According to the Belgian law, ONDRAF/NIRAS (Belgian Radioactive Waste Management Agency) was entrusted with the clean-up and the decommissioning operations of the former BMB facilities, nowadays known as 'ONDRAF/NIRAS Site Fleurus' (ONSF). In June 2015, ONSF launched a Decontamination and Decommissioning (D and D) program, for which Tractebel supports the definition of the clean-up and decommissioning strategies; the drafting of the Final Decommissioning Plan (FDP) and License Application for decommissioning; and the follow-up of the clean-up and upcoming D and D works on site. Four nuclear buildings are part of the clean-up and D and D activities. One of them, Building 14 (B14), represents the most challenging task with the clean-up of highly contaminated areas and their further decommissioning up to greenfield. Beside its two cyclotrons successively used for the production of radioisotopes, this building features hot cells and glove boxes used for the purification of radioisotopes and the conditioning of the final pharmaceutical product. The present paper aims at presenting the development of the D and D program in terms of modifications of existing facilities to allow carrying out the clean-up and D and D activities and the management of dismantled radioactive materials in a safe, efficient and cost-effective way as well as in terms of strategic options to be developed for the FDP. To support the clean-up and D and D activities, several workshops have been designed in order to treat radioactive materials removed from the building rooms. Those workshops feature an input buffer storage area, a common output buffer storage area and installations for the treatment of radioactive materials and waste (handling devices, cutting means, decontamination means, free release measurements means, etc.). Some modifications to the existing auxiliary systems will be required in order to dispose of appropriate systems to operate those workshops in a safe way. Activated concrete structures will constitute the most important part of radioactive materials that will arise from the decommissioning activities. To limit the total decommissioning costs, and especially the costs associated to radioactive waste management, two strategies have been developed in order to manage a part of activated concrete as candidate for free release with a certain decay period or as candidate for conventional landfill. Both strategies will have to be further detailed and discussed with the competent Authorities to ensure they can actually be implemented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress on Near-Term Tasks for the Development of Advanced Reactor Mechanistic Source Term Modeling and Simulation Tools

To assist both the advanced reactor industry and U.S. Nuclear Regulatory Commission (NRC) in the pursuit of reactor design and licensing, the U.S. Department of Energy (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has established a mechanistic source term (MST) research project under the auspices of the Multiphysics Applications technical area. MST analysis is central to the reactor licensing process and a focus of the NRC regarding their mission to provide reasonable assurance of adequate protection of public health and safety and environment. The MST research project is a collaboration between Argonne National Laboratory (Argonne) and Sandia National Laboratories (SNL) with a high-level objective to coordinate the development of comprehensive advanced reactor MST mod/sim capabilities to support risk-informed design and licensing decisions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A three-phase workflow for general and expressive representations of nondeterminism in HPC applications

Nondeterminism is an increasingly entrenched property of high-performance computing (HPC) applications and has recently been shown to seriously hamper debugging and reproducibility efforts. Additionally, tools for addressing the nondeterministic debugging problem have emerged, but they do not provide methods for systematically cataloging the nondeterminism in a given application. We propose a three-phase workflow for representing executions of nondeterministic message passing interface programs as event graphs, quantifying their structural similarity with graph kernels, and applying machine learning techniques to investigate shared properties across applications. We present an empirical study comparing two graph kernels’ suitability for this task and propose future uses of the methodology.

97 MATHEMATICS AND COMPUTING↗

Final Technical Report: Commercial Advanced Lighting Control (ALC) Demonstration and Deployment

This three-year demonstration and deployment project sought to address market barriers to accelerating the adoption of Advanced Lighting Controls (ALCs), an underutilized technology with low market penetration. ALCs are defined as networked, addressable lighting control systems that utilize software or intelligent controllers to combine multiple energy-saving lighting control strategies in a single space (e.g., smart-time scheduling, daylight harvesting, task tuning, occupancy control, personal control, variable load-shedding, and plug-load control). The networked intelligent aspect of these systems allows applicable lighting control strategies to be combined in a single space, layered over one another, maximizing overall energy-savings. The project included five real building demonstrations of ALCs across the Northeast US region. The demonstrations provided valuable data and experience to support deployment tasks that are necessary to overcome market barriers. These deployment tasks included development of training resources for building designers, installers, and trades, as well as development of new energy efficiency rebates for the technology from Efficiency Forward’s utility partners. Educating designers, installers, and trades on ALCs is a critical task for reducing the cost of the technology that is currently inflated due to perceived complexity and unfamiliarity with how to design and install the systems. Further, utility and non-utility energy efficiency programs continue to relegate the technology to custom or ill-suited prescriptive program designs that do not effectively deploy the technology at scale. This project developed new, scalable rebate approaches for the technology. Efficiency Forward utilized their DesignLights Consortium® (DLC) brand and network of 81 DLC member utilities to develop and deploy the results of the project. The outputs of the project have included five published case studies, a six-hour ALC technology training curriculum that has already been deployed in five US states, and new rebates offered for the technology that have been deployed by a dozen utilities across the US. Widespread adoption of ALC technology in commercial buildings would provide tremendous benefits. The current market penetration of ALC systems is estimated at <0.1% in commercial buildings. If ALC systems were installed in all commercial buildings, approximately 1,051 TBtu of energy could be saved. This would translate into customer cost savings of approximately $10.7 billion annually.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Wind Turbine Drivetrain Topology for Improving System Reliability (CRADA CRD-10-400 Final Report)

Alstom Power has a desire to locate its latest entrance into the U.S. market at a location that truly tests the durability of the machine in a turbulent environment as well as verify the basic operating characteristics of the machine on a 60 Hz grid. The DOE/NREL National Wind Technology Center (NWTC) is well suited for this goal. The DOE/NREL Wind Program is working on improving drivetrain reliability through its Gearbox Reliability Collaborative (GRC). Alstom is also interested in performing research on their innovative drivetrain that is aligned with the objectives of the GRC. The tasks outlined in this Joint Work Statement are intended to accomplish these goals to the mutual satisfaction of both parties and the advancement of the understanding of wind turbine drivetrain behavior.

17 WIND ENERGY↗

Codes and Ordinances for Clean Energy: Highland Park Pathways to Power [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "A" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Housing Characteristics and Energy Burden Analysis for Highland Park, Michigan

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "C", related to Housing Characteristics and Energy Burden Analysis. Assessed residential building energy consumption across different building envelope and electrification upgrades to see potential savings in energy consumption, emissions, energy bills, and energy burden.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prefeasibility Analysis of Behind-the-Meter Distributed Energy Resources in Highland Park, MI: Highland Park Pathways to Power [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. NREL used the REopt platform to evaluate the techno-economic potential of adding solar PV, electric storage, and/or diesel generators at several locations in Highland Park, Michigan: a typical residential and commercial building in Highland Park, the Earnest T. Ford Recreation Center, and the Parker Village Microgrid. The analysis goals focused on the ability of solar PV, electric storage, and/or diesel generators to reduce electricity costs and improve site resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modeling the Transient Reactor Test Loop in TRACE for PWR Critical Heat Flux Benchmarking

Understanding transient critical heat flux (CHF) resulting from a Reactivity Insertion Accident (RIA) in nuclear systems is an extremely undeveloped field. Though many experiments have been done for CHF, remarkably few have been done for rods at PWR operating temperature and pressure (300 deg. C, 2200 psia) with a short time constant ramp in power. This leads to many concerns regarding understanding how RIA scenarios develop and evolve in commercial nuclear reactors. With a limited understanding of the phenomenology governing transient CHF, there is little hope in being able to accurately model these scenarios using today's thermal hydraulic codes. The Accident Tolerant Fuels (ATF) Program established by the Department of Energy (DOE) is seeking out new fuel and cladding systems that can be used to reduce the probability and consequences of severe accidents. To better understand this phenomenon, the DOE is restarting the Transient Reactor Test (TREAT) Facility at the Idaho National Laboratory (INL). TREAT will be able to provide representative neutronic boundary conditions for testing coupled thermal hydraulics on the Transient Water Environment Recirculating Loop (TWERL) to study transient CHF with the best representation possible. To support this task, Oregon State University (OSU) is designing and building a representative flow loop that will be able to mimic the conditions of TWERL (sans the neutronic boundary conditions) to create a benchmark study for existing lumped parameter thermal-hydraulic codes such as RELAP5 and TRACE. This flow loop, the Transient Reactor Test Facility (TRTL), will support the ATF program by providing much needed NQA-1 data for transient CHF at operating temperature and pressure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Publicly Available Landscape Analysis Tool for Biodefense Policy

Outbreaks of infectious diseases, coupled with an increasing biological threat from non-state actors, highlight the continued need to prioritize biodefense. The Blue Ribbon Panel on Biodefense has noted that the US remains ‘underprepared’ for a catastrophic biological attack or pandemic and emphasized increased coordination is essential. Consistent with this recommendation, the FY17 National Defense Authorization Act tasked the Secretaries of Defense, Health and Human Services, Homeland Security, and Agriculture to “jointly develop a national biodefense strategy and associated implementation plan, which shall include a review and assessment of biodefense policies, practices, programs and initiatives.”

Omberg, Kristin M.↗

Selective Recovery of Critical Materials from Geothermal Fluid

This project, funded by the DOE Small Business Voucher program, assisted the partner with the development of ion-imprinted adsorbents for the selective extraction of rare earth elements (REE) from geothermal brines. This effort seeks to utilize a currently untapped resource thus diversifying the U. S. REE market. The initial stage of the program focused on the adsorbent developed by partner and optimization of the adsorbent. The adsorbent was based upon an ion imprinted ligand that was copolymerized with a crosslinker to generate the REE selectivity. During this task, the adsorbents were irradiated via electron beam at the NEO Beam Electron Beam Crosslinking Facility (Mercury Plastics, Middlefield, OH) to induce further crosslinking. The irradiation crosslinked adsorbents exhibited no difference in the Fourier transform infrared spectroscopic (FTIR) analysis suggesting inefficiency in the crosslinking. In the later stage of the effort, a new method was proposed and studied at ORNL involving a new partnership between the partner and a commercial polymer vender. This resulted in a new material being developed which allows the partner to utilize a commercial support and integrate the synthesis into a production-ready product stream. This will enhance the route to commercialization for the partner resulting in a quicker market penetration for the product. The new adsorbent exhibits selectivity for REE over transition metals commonly found within geothermal brines. Further optimization is required for enhanced selectivity, capacity, and intra-lanthanide separations.

58 GEOSCIENCES↗

Industrial Assessment Center Program (Final Report)

This report summarizes the activities of the Industrial Assessment Center (IAC) at San Francisco State University (SFSU) under the Award No. DE-EE0007705 for the period of October 1, 2016 through September 30, 2021. The work performed under the award and related achievements are summarized per task in the statement of the work in the award.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Blast Effects on Buildings (Final Report)

Lawrence Livermore National Laboratory (LLNL) has conservatively reduced the explosive safety standards suggested by the Small Quantities in Research Laboratories (SQRL) program testing by 60%. For this reason, further research into the detailed effects of small amounts of explosives in typically constructed rooms is needed in order to improve their factor of safety. The team was tasked with designing an experiment to investigate the effect of different variables on drywall under explosive blasts. In order to meet this objective, the team conducted a comprehensive literature review to gain an understanding of industry-standard construction practices and review previous tests conducted by the Army corp of engineers. Since the team used PBXN-5 rather than C4, as in SQRL, an initial shot was conducted to compare damage levels. From those results and the physical constraints of the testing chamber, the team redesigned multiple single-panel drywall frames to capture the entirety of the incurred damage. Proposed designs were narrowed down using a decision matrix. From the study of previous tests and literature review, variables were chosen that the team hypothesized to have an impact on drywall strength. The variables that were tested were chosen from the results of that work and specific variables the sponsor was interested in, and they were paint, humidity/moisture content, and explosive positioning relative to the studs. Detailed plans were made for each variable according to what conditions the team wanted to investigate. For humidity, this involved testing low, ambient, and high conditions by treating the panels in a chamber. Preliminary shots were performed to test the structural integrity of the frame and streamline the test diagnostics which involved a high-speed camera placed behind the drywall, outside of the chamber, and a pressure probe placed behind the drywall, inside the chamber. Once the instrumentation, diagnostics, and frame design were finalized, a quantitative damage criteria matrix was created to categorize the results of the main shot series. In conjunction with evidence from the high-speed video, the achieved damage levels indicate that high moisture content drywall is better able to withstand explosive blasts. Larger stud damage and lower drywall damage occurred when the explosive was located directly in front of a stud. Paint had no noticeable impact on strength. Ultimately, the team conducted a total of 17 tests, leaving the door open for future in-depth research into the impact of humidity.

36 MATERIALS SCIENCE↗