Search NASA⌕ Search

SEARCH · Search NASA

Results for “test support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Nonproliferation and Arms Control Research and Development (NPAC R&D) [Slides]

NPAC R&D focus areas include: Advancing U.S. capabilities to detect and characterize nuclear weapon development activities globally, including material production, the movement of special nuclear materials and nuclear weapons, and the testing or use of nuclear weapons, Supporting the development and testing of policy options and technical capabilities for international nuclear safeguards, arms control / treaty verification, nuclear export controls, and nonproliferation initiatives consistent with U.S. Government goals and objectives to enable monitoring and verification, Utilizing uranium, lithium, and high explosives (HE) materials expertise to support national-level activities in nuclear forensics and nuclear detection technology testing and evaluation, Providing unique training and capacity-building programs, particularly with the Nuclear Detection and Sensor Testing Center (NDSTC), and Engaging internationally to promote nonproliferation and arms control norms and best practices through bilateral and multilateral work.

36 MATERIALS SCIENCE↗

TEAMER: Pitching Foil Crossflow Turbine Efficiency Data

This dataset documents the efficiency testing of a pitching foil crossflow turbine, conducted at the University of New Hampshire's (UNH) Chase Ocean Engineering Laboratory tow tank facility. The tests explored various pitch phases and amplitudes, ranging from 0 to 18 degrees, across different flow speeds and turbine RPMs. Specifically, testing was performed at pitch amplitudes of 0,3,6,9,12,15 and 18 degrees. The results indicate that turbine efficiency improves with increased pitch amplitude, reaching optimal performance at 12 degrees. Modifications were made to the test frame by UNH to enhance the stiffness of the support structure. The testing specifically mapped the efficiency of a single quadrant of the Ocean Renewable Power Company (ORPC) Autonomous Turbine Generator Unit (ATGU), covering the full range of allowable pitching amplitudes and phases. The dataset provides both raw and processed data, including drag and torque measurements, and contains Python scripts used for data processing and visualization. This research was supported by funding from TEAMER RFTS 1 (Request for Technical Support).

16 TIDAL AND WAVE POWER↗

TESTING OF A ROTARY MICROFILTER TO SUPPORT HANFORD APPLICATIONS

Savannah River National Laboratory (SRNL) researchers are investigating and developing a rotary microfilter for solid-liquid separation applications at the Savannah River Site (SRS). Because of the success of that work, the Hanford Site is evaluating the use of the rotary microfilter for its Supplemental Pretreatment process. The authors performed rotary filter testing with a full-scale, 25-disk unit with 0.5 {micro} filter media manufactured by Pall Corporation using a Hanford AN-105 simulant at solids loadings of 0.06, 0.29, and 1.29 wt%. The conclusions from this testing are: (1) The filter flux at 0.06 wt% solids reached a near constant value at an average of 0.26 gpm/ft{sup 2} (6.25 gpm total). (2) The filter flux at 0.29 wt% solids reached a near constant value at an average of 0.17 gpm/ft{sup 2} (4 gpm total). (3) The filter flux at 1.29 wt% solids reached a near constant value at an average of 0.10 gpm/ft{sup 2} (2.4 gpm total). (4) Because of differences in solids loadings, a direct comparison between crossflow filter flux and rotary filter flux is not possible. The data show the rotary filter produces a higher flux than the crossflow filter, but the improvement is not as large as seen in previous testing. (5) Filtrate turbidity measured < 4 NTU in all samples collected. (6) During production, the filter should be rinsed with filtrate or dilute caustic and drained prior to an extended shutdown to prevent the formation of a layer of settled solids on top of the filter disks. (7) Inspection of the seal faces after {approx} 140 hours of operation showed an expected amount of initial wear, no passing of process fluid through the seal faces, and very little change in the air channeling grooves on the stationary face. (8) Some polishing was observed at the bottom of the shaft bushing. The authors recommend improving the shaft bushing by holding it in place with a locking ring and incorporated grooves to provide additional cooling. (9) The authors recommend that CH2MHill Hanford test other pore size media to determine the optimum pore size for Hanford waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of the DUNE APATF cryogenic system

Fermi National Accelerator Laboratory (FNAL) is developing the international Long- Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) to advance neutrino science. The flagship of the DUNE project consists of a large particle detector constructed one-mile (1.6 km) beneath the surface at the Sanford Underground Research Facility (SURF) in Lead, SD. The SURF detector is the largest of its type ever built and is comprised of four cryostats totaling 70,000 tons of liquid argon (LAr) to record neutrino interactions with unprecedented precision. Each cryostat houses a detector, the first includes 150 Anode Panel Assemblies (APA) submersed within 17,500 tons of LAr. Before installing 150 APA within the SURF detector they will be cryogenically cooled to nominally 90 K at the APA Test Facility (APATF) utilizing nitrogen flows. The APATF cryogenic system is entirely located one-mile underground at the SURF facility and includes nominally 13 kW of refrigeration at 80 K, cryogenic transfer lines, APA test cryostats, a cryogenic control system, and various control and pressure safety elements to ensure performance and safety requirements are achieved. The APATF preliminary design is in progress and major considerations include an efficient, costeffective mechanism to deliver the required refrigeration to the APATF underground, support of rigid testing intervals to support the DUNE operating schedule, temperature stability of the APA and electronics within cryostats, efficient cryogenic system operation to minimize heat leak and/or liquid nitrogen consumption, thermo-mechanical stability and flexibility of components, and pressure safety of the APATF cryogenic system. Installation and integration of the APATF cryogenic system within the footprint and to adjacent sub-systems is also discussed.

43 PARTICLE ACCELERATORS↗

Long-term corrosion testing plan.

This document describes the testing and facility requirements to support the Yucca Mountain Project long-term corrosion testing program. The purpose of this document is to describe a corrosion testing program that will (a) reduce model uncertainty and variability, (b) reduce the reliance upon overly conservative assumptions, and (c) improve model defensibility. Test matrices were developed for 17 topical areas (tasks): each matrix corresponds to a specific test activity that is a subset of the total work performed in a task. A future document will identify which of these activities are considered to be performance confirmation activities. Detailed matrices are provided for FY08, FY09 and FY10 and rough order estimates are provided for FY11-17. Criteria for the selection of appropriate test facilities were developed through a meeting of Lead Lab and DOE personnel on October 16-17, 2007. These criteria were applied to the testing activities and recommendations were made for the facility types appropriate to carry out each activity. The facility requirements for each activity were assessed and activities were identified that can not be performed with currently available facilities. Based on this assessment, a total of approximately 10,000 square feet of facility space is recommended to accommodate all future testing, given that all testing is consolidated to a single location. This report is a revision to SAND2008-4922 to address DOE comments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of Pertechnetate From Simulated Nuclear Waste Streams Using Supported Zerovalent Iron

The application of nanoparticles of predominantly zerovalent iron (nanoiron), either unsupported or supported, to the separation and reduction of pertechnetate anions (TcO{sub 4{sup -}}) from complex waste mixtures was investigated as an alternative approach to current waste-processing schemes. Although applicable to pertechnetate-containing waste streams in general, the research discussed here was directed at two specific potential applications at the U.S. Department of Energy's Hanford Site: (1) the direct removal of pertechnetate from highly alkaline solutions, typical of those found in Hanford tank waste, and (2) the removal of dilute pertechnetate from near-neutral solutions, typical of the eluate streams from commercial organic ion-exchange resins that may be used to remediate Hanford tank wastes. It was envisioned that both applications would involve the subsequent encapsulation of the loaded sorbent material into a separate waste form. A high surface area (>200 m{sup 2}/g) base-stable, nanocrystalline zirconia was used as a support for nanoiron for tests with highly alkaline solutions, while a silica gel support was used for tests with near-neutral solutions. It was shown that after 24 h of contact time, the high surface area zirconia supported nanoiron sorbent removed about 50% (K{sub d} = 370 L/kg) of the pertechnetate from a pH 14 tank waste simulant containing 0.51 mM TcO{sub 4{sup -}} and large concentrations of Na{sup +}, OH{sup -}, NO{sub 3{sup -}}, and CO{sub 3{sup 2-}} for a phase ratio of 360 L simulant per kg of sorbent. It was also shown that after 18 h of contact time, the silica-supported nanoiron removed >95% pertechnetate from a neutral pH eluate simulant containing 0.076 mM TcO{sub 4{sup -}} for a phase ratio of 290 L/kg. It was determined that in all cases, nanoiron reduced the Tc(VII) to Tc(IV), or possibly to Tc(V), through a redox reaction. Finally, it was demonstrated that a mixture of 20 mass % of the solid reaction products obtained from contacting zirconia-supported nanoiron with an alkaline waste solution containing Re(VII), a surrogate for Tc(VII), with 80 mass % alkali borosilicate based frit heat-treated at 700 {sup o}C for 4 h sintered into an easily handled glass composite waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Current nonclinical testing paradigm enables safe entry to First-In-Human clinical trials: The IQ consortium nonclinical to clinical translational database

The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2 × 2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. - Highlights: • Translational database created to determine animal to human safety concordance. • 182 molecules with animal and clinical data; concordance parameters determined • Positive predictive value of 43%; Negative predictive value of 86% • Absence of toxicity in animal study strongly predicts similar outcome in the clinic. • Database supports animal testing to ensure human safety in the clinic.

60 APPLIED LIFE SCIENCES↗

Programmable Gene Knockdown in Diverse Bacteria Using Mobile‐CRISPRi

Abstract Facile bacterial genome sequencing has unlocked a veritable treasure trove of novel genes awaiting functional exploration. To make the most of this opportunity requires powerful genetic tools that can target all genes in diverse bacteria. CRISPR interference (CRISPRi) is a programmable gene‐knockdown tool that uses an RNA‐protein complex comprised of a single guide RNA (sgRNA) and a catalytically inactive Cas9 nuclease (dCas9) to sterically block transcription of target genes. We previously developed a suite of modular CRISPRi systems that transfer by conjugation and integrate into the genomes of diverse bacteria, which we call Mobile‐CRISPRi. Here, we provide detailed protocols for the modification and transfer of Mobile‐CRISPRi vectors for the purpose of knocking down target genes in bacteria of interest. We further discuss strategies for optimizing Mobile‐CRISPRi knockdown, transfer, and integration. We cover the following basic protocols: sgRNA design, cloning new sgRNA spacers into Mobile‐CRISPRi vectors, Tn 7 transfer of Mobile‐CRISPRi to Gram‐negative bacteria, and ICE Bs1 transfer of Mobile‐CRISPRi to Bacillales. © 2020 The Authors. Basic Protocol 1 : sgRNA design Basic Protocol 2 : Cloning of new sgRNA spacers into Mobile‐CRISPRi vectors Basic Protocol 3 : Tn 7 transfer of Mobile‐CRISPRi to Gram‐negative bacteria Basic Protocol 4 : ICE Bs1 transfer of Mobile‐CRISPRi to Bacillales Support Protocol 1 : Quantification of CRISPRi repression using fluorescent reporters Support Protocol 2 : Testing for gene essentiality using CRISPRi spot assays on plates Support Protocol 3 : Transformation of E. coli by electroporation Support Protocol 4 : Transformation of CaCl 2 ‐competent E. coli

59 BASIC BIOLOGICAL SCIENCES↗

Degradation of Ionic Pathway in PEM Fuel Cell Cathode

The degradation of the ionic pathway throughout the catalyst layer in proton exchange membrane fuel cells was studied under an accelerated stress test of catalyst support (potential hold at 1.2 V). Electrochemical behaviors of the cathode based on graphitic mesoporous carbon supported Pt catalyst were examined using electrochemical impedance spectroscopy and cyclic voltammetry. Impedance data were plotted and expressed in the complex capacitance form to determine useful parameters in the transmission line model: the double-layer capacitance, peak frequency, and ionic resistance. Electrochemical surface area and hydrogen crossover current through the membrane were estimated from cyclic voltammogram, while cathode Faradaic resistance was compared with ionic resistance as a function of test time. It was observed that during an accelerated stress test of catalyst support, graphitic mesoporous carbon becomes hydrophilic which increases interfacial area between the ionomer and the catalyst up to 100 h. However, the ionic resistance in the catalyst layer drastically increases after 100 h with further carbon support oxidation. The underlying mechanism has been studied and it was found that significant degradation of ionic pathway throughout the catalyst layer due to catalyst support corrosion induces uneven hydration and mechanical stress in the ionomer.

08 HYDROGEN↗

The Transient Reactor Test Facility (TREAT)

TREAT operated from 1959-1994, later refurbished & resumed operation in 2017 to support fuel safety testing Zircaloy-clad graphite/fuel blocks comprise core Virtually any power history possible within ~2000 MJ core transient energy capacity From milliseconds to minutes: Pulses, Ramps, LOCA Fuel motion monitoring system “hodoscope” observes fast neutrons emitted from specimens to track fuel relocation in real time Reactor also can be a neutron source to adjacent radiography facility Experiment vehicle does everything else Safety containment, specimen environment, and instrumentation

22 GENERAL STUDIES OF NUCLEAR REACTORS↗