Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Femtosecond time-resolved photoemission electron microscopy for spatiotemporal imaging of photogenerated carrier dynamics in semiconductors

We constructed an instrument for time-resolved photoemission electron microscopy (TR-PEEM) utilizing femtosecond (fs) laser pulses to visualize the dynamics of photogenerated electrons in semiconductors on ultrasmall and ultrafast scales. The spatial distribution of the excited electrons and their relaxation and/or recombination processes were imaged by the proposed TR-PEEM method with a spatial resolution about 100 nm and an ultrafast temporal resolution defined by the cross-correlation of the fs laser pulses (240 fs). A direct observation of the dynamical behavior of electrons on higher resistivity samples, such as semiconductors, by TR-PEEM has still been facing difficulties because of space and/or sample charging effects originating from the high photon flux of the ultrashort pulsed laser utilized for the photoemission process. Here, a regenerative amplified fs laser with a widely tunable repetition rate has been utilized, and with careful optimization of laser parameters, such as fluence and repetition rate, and consideration for carrier lifetimes, the electron dynamics in semiconductors were visualized. For demonstrating our newly developed TR-PEEM method, the photogenerated carrier lifetimes around a nanoscale defect on a GaAs surface were observed. The obtained lifetimes were on a sub-picosecond time scale, which is much shorter than the lifetimes of carriers observed in the non-defective surrounding regions. Our findings are consistent with the fact that structural defects induce mid-gap states in the forbidden band, and that the electrons captured in these states promptly relax into the ground state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Instrument for Time-Resolved OH and HO 2 Quantification in High-Pressure Laboratory Kinetics Studies

Here, we have constructed a new time-resolved high-pressure fluorescence assay by gas expansion (HP-FAGE) apparatus, optimized for the detection of OH and HO 2 radicals in complex gas-phase reactions. The new instrument fills a gap in the existing experimental toolkit for chemical kinetics by enabling the quantification of two key reactive species with microsecond time resolution from high-pressure sources, which was previously not attainable. The HP-FAGE is interfaced with a flow reactor, designed for pressures up to 100 bar and temperatures up to 1000 K, in which reactions are initiated by laser photolysis of radical precursors at repetition rates of 1–10 Hz. The HP-FAGE samples gas out of the reactor into a miniature FAGE chamber, where OH is detected by resonant laser-induced fluorescence using a time-delayed probe laser pulse. HO 2 is converted to OH via reaction with NO and then detected by OH fluorescence. The novel FAGE design places the probe region very close to the gas expansion, minimizing the transport time of sampled molecules and resulting in time resolution better than 20 μs for both OH and HO 2 . We calibrate the sensitivity of HP-FAGE, validate its performance with measurements of well-known reaction kinetics (OH + CH 4 , OH + OH, OH + HO 2 , and HO 2 + HO 2 ), and discuss prospects for its future use.

calibration↗

Observation of Ultrafast Intersystem Crossing in Thymine by Extreme Ultraviolet Time-Resolved Photoelectron Spectroscopy

We studied the photoinduced ultrafast relaxation dynamics of the nucleobase thymine using gas-phase time-resolved photoelectron spectroscopy. Employing extreme ultraviolet pulses from high harmonic generation for photoionization, we substantially extend our spectral observation window with respect to previous studies. This enables us to follow relaxation of the excited state population all the way to low-lying electronic states including the ground state. In thymine, we observe relaxation from the optically bright $^1ππ*$ state of thymine to a dark $^1nπ*$ state within 80 ± 30 fs. The $^1nπ*$ state relaxes further within 3.5 ± 0.3 ps to a low-lying electronic state. By comparison with quantum chemical simulations, we can unambiguously assign its spectroscopic signature to the $^3ππ*$ state. Hence, our study draws a comprehensive picture of the relaxation mechanism of thymine including ultrafast intersystem crossing to the triplet manifold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved PIV Measurements of Flow Field at the Exit of a Diffuser Mounted on a Rotating Detonation Combustor

Time-resolved particle image velocimetry at 30 kHz is applied to the exhaust flow field of a RDC system configured with a diffuser geometry and a converging-diverging (CD) nozzle. The RDC is operated with methane fuel and oxygen-enriched air, motivated by power generation applications. The measured flow-field is discretized into axial and non-axial velocity components. Results are shown to characterize the flow-field across a cord length at the exit plane. Instantaneous contours of the two velocity components, and 1D histograms of velocity components, and 2D histograms of total velocity and tilt angle are shown at multiple locations in the flow. Repeatability of the data is evaluated by comparing tests conducted at similar flow rates. Results are presented for a baseline test case, and test cases showing the effect of reactant higher flow rate and CD nozzle geometry. Finally, the results are compared to a previous RDC study without the diffuser to compare the effectiveness of the diffuser and CD nozzle designs in mitigating the flow periodicity at the combustor exit.

particle image velocimetry, pressure gain combusti↗

Time-resolved IUE studies of cataclysmic variables. I - Eclipsing systems IP Peg, PG 1030+590, and V1315 Aql

IUE time-resolved spectra of the high-inclination cataclysmic variables IP Peg, PG 1030+590, and V1315 Aql are analyzed in order to determine the characteristics of the disk, hotspots, and white dwarfs. The UV continuum flux distributions are generally flatter than systems of low inclination and high mass-transfer rate, and the white dwarfs/inner disk appear to be relatively cool (15,000-19,000 K) for their orbital periods, possibly because the boundary layers are blocked from view. The continuum fluxes increase at spot phases, with the spot providing the dominant flux in IP Peg. The spot temperatures range from hot (20,000 K) in IP Peg, and perhaps in PG 1030+590, to cool (11,000 K) in V1315 Aql. The C IV emission lines show slightly larger decreases at spot phases than during eclipse, which implies an extended stream area.

Szkody, Paula↗

Time-Resolved, NIR Two-Tone Frequency Modulation Spectroscopy for Quantitative Measurement of HO 2 Radical in Fuel Oxidation Reactions

Time-resolved two-tone frequency modulation (TTFM) absorption spectroscopy has been used to measure, in situ and quantitatively, hydroperoxy (HO 2 ) radical in fuel oxidation reactions at the first overtone transitions (2v 1 ) of HO 2 near 1509nm. Typical HO 2 detection limit is on the order of 10 11 molecule cm -3 , which corresponds to a relative absorption of 10 -5 . TTFM method successfully removes low frequency thermal lensing noise in measured HO 2 kinetic time traces, which is a general noise source in fuel oxidation absorption experiments. Compared with previous works, we have upgraded the TTFM experiment with a NIR distributed feedback (DFB) diode laser, a fiber-coupled broadband phase modulator, and a two-channel wave generator, which have improve the performance of our experiment substantially.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved Fourier-transform infrared emission spectroscopy of Au in the 1800-4000-cm{sup -1} region: Rydberg transitions

Time-resolved Fourier-transform infrared spectroscopy was applied for observations of the emission arising after irradiation of a Au target with a pulsed nanosecond ArF (lambda=193 nm) laser. A high-repetition-rate laser (1.0 kHz) with an output energy of 15 mJ was focused on a rotating metal target inside a vacuum chamber (average pressure 10{sup -2} Torr). The infrared emission spectra were observed in the 1800-4000cm{sup -1} spectral region with a time profile showing maximum emission intensity in 9-11 mus after a laser shot. Seven prominent lines are reported; most of them are identified as being due to transitions between low Rydberg nl states of Au with n=5-10 and l=0-3. An alternative identification (6f{sub 5/2}->7d{sub 3/2}) is given for the 2518.489cm{sup -1} line previously classified as 8d{sub 5/2}->5f{sub 5/2}. On the basis of the measured lines, three f levels of the Au atom are reported and revised values are given for six other levels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of spin diffusion on electron spin relaxation time measured with a time-resolved microscopic photoluminescence technique

We performed measurements at room temperature for a GaAs/AlGaAs multiple quantum well grown on GaAs(110) using a time-resolved microscopic photoluminescence (micro-PL) technique to find what effects spin diffusion had on the measured electron spin relaxation time, τ{sub s}, and developed a method of estimating the spin diffusion coefficient, D{sub s}, using the measured data and the coupled drift-diffusion equations for spin polarized electrons. The spatial nonuniformities of τ{sub s} and the initial degree of electron spin polarization caused by the pump intensity distribution inside the focal spot were taken into account to explain the dependence of τ{sub s} on the measured spot size, i.e., a longer τ{sub s} for a smaller spot size. We estimated D{sub s} as ∼100 cm{sup 2}/s, which is similar to a value reported in the literature. We also provided a qualitative understanding on how spin diffusion lengthens τ{sub s} in micro-PL measurements.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

New method for measuring time-resolved spectra of lanthanide emission using square-wave excitation

A method using modulated continuous wave (CW) visible laser to measure time-resolved fluorescence spectra of trivalent rare-earth ions has been developed. Electro-optic modulator was used to modulate the CW pumping laser with a rise time of 2 μs. CW Nd{sup 3+} lasers were used as examples to present the method. Upconversion dynamic process of Ho{sup 3+} was studied utilizing a 532 nm CW laser. Quantum cutting dynamic process from Tb{sup 3+} to Yb{sup 3+} was analyzed by a 473 nm CW laser. This method can be applied to any CW laser such as He-Ne laser, Ar{sup +} laser, Kr{sup +} laser, Ti:sapphire laser, etc.

36 MATERIALS SCIENCE↗

Scintillation Properties and Time-Resolved Spectroscopy of a Novel Scintillator Material:Ce3+- Activated Li3Lu(PO4)2 Crystals - Corrected Proof

The scintillation properties and time-resolved spectroscopy results for Li3Lu(PO4)2:Ce - a new Ce3+-activated crystalline scintillator have been determined. This material contains stoichiometric amounts of Li, and can be synthesized either with the use of 6Li-enriched or 6Li-depleted isotopes, for achieving thermal neutron sensitivity or X-ray/gamma-ray detection without neutron sensitivity, respectively. The scintillation of Li3Lu(PO4)2:Ce is based on the Ce3+-activator UV (336 and 360 nm) emission, and for a 2 wt. % activation level and gamma ray photon excitation, it exhibits a light yield of about 5300 photons/MeV and a decay time constant of 24.7 ns - with no longer component observed in the time range up to 2 ms. Host emissions, while present for some specific excitations in the region of the bandgap energy, does not appear to play a significant role in the material s scintillation, which is most probably accomplished by the consecutive capture and recombination of free band holes and electrons on the activator ions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charge Carrier Lifetime Determination in Graded Absorber Solar Cells Using Time‐Resolved Photoluminescence Simulations and Measurements

Thin‐film photovoltaic device efficiencies are limited by carrier recombination, thus understanding recombination mechanisms is critical for performance improvements. Bulk minority carrier lifetime ( τ bulk ) is a critical parameter for solar cells but is difficult to determine in P–N junction devices, especially for high doping. As doping ≥10 16 cm −3 is required for efficient drift‐charge‐carrier‐collection devices, a method for τ bulk determination in doped P–N junction devices is necessary. This work utilizes time‐resolved photoluminescence (TRPL) simulations to quantify bulk and interface recombination properties in highly doped, graded absorber CdSeTe structures. The two methods developed here for τ bulk determination include utilization of an instantaneous lifetime representation to guide TRPL fitting and direct comparison between measured and simulated decays. Simulations verified that both methods are valid for state‐of‐the‐art device architectures which include graded bandgap absorbers, graded doping, and graded lifetimes. Shifts in the dominant recombination mechanism are identified for sufficiently long τ bulk , where front and back interface quality plays a more prominent role. Evaluation of surface recombination velocities and conduction band offset illustrate electro‐optical advantages of a positive conduction band offset and highlight the necessity of improved interfaces as bulk quality in photovoltaic devices improves.

14 SOLAR ENERGY↗

Time-resolved x-ray diffraction techniques for bulk polycrystalline materials under dynamic loading

We have developed two techniques for time-resolved x-ray diffraction from bulk polycrystalline materials during dynamic loading. In the first technique, we synchronize a fast detector with loading of samples at strain rates of ∼10{sup 3}–10{sup 4} s{sup −1} in a compression Kolsky bar (split Hopkinson pressure bar) apparatus to obtain in situ diffraction patterns with exposures as short as 70 ns. This approach employs moderate x-ray energies (10–20 keV) and is well suited to weakly absorbing materials such as magnesium alloys. The second technique is useful for more strongly absorbing materials, and uses high-energy x-rays (86 keV) and a fast shutter synchronized with the Kolsky bar to produce short (∼40 μs) pulses timed with the arrival of the strain pulse at the specimen, recording the diffraction pattern on a large-format amorphous silicon detector. For both techniques we present sample data demonstrating the ability of these techniques to characterize elastic strains and polycrystalline texture as a function of time during high-rate deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MONSTIR II: A 32-channel, multispectral, time-resolved optical tomography system for neonatal brain imaging

We detail the design, construction and performance of the second generation UCL time-resolved optical tomography system, known as MONSTIR II. Intended primarily for the study of the newborn brain, the system employs 32 source fibres that sequentially transmit picosecond pulses of light at any four wavelengths between 650 and 900 nm. The 32 detector channels each contain an independent photo-multiplier tube and temporally correlated photon-counting electronics that allow the photon transit time between each source and each detector position to be measured with high temporal resolution. The system's response time, temporal stability, cross-talk, and spectral characteristics are reported. The efficacy of MONSTIR II is demonstrated by performing multi-spectral imaging of a simple phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Changes and Thermal Stability of Charged LiNi1/3Co1/3Mn1/3O2 Cathode Material for Li-ion Batteries Studied by Time-Resolved XRD

Structural changes and their relationship with thermal stability of charged Li0.33Ni1/3Co1/3Mn1/3O2 cathode samples have been studied using time-resolved X-ray diffraction (TR-XRD) in a wide temperature from 25 to 600 C with and without the presence of electrolyte in comparison with Li0.27Ni0.8Co0.15Al0.05O2 cathodes. Unique phase transition behavior during heating is found for the Li0.33Ni1/3Co1/3Mn1/3O2 cathode samples: when no electrolyte is present, the initial layered structure changes first to a LiM2O4-type spinel, and then to a M3O4-type spinel and remains in this structure up to 600 C. For the Li0.33Ni1/3Co1/3Mn1/3O2 cathode sample with electrolyte, additional phase transition from the M3O4-type spinel to the MO-type rock salt phase takes place from about 400 to 441 C together with the formation of metallic phase at about 460 C. The major difference between this type of phase transitions and that for Li0.27Ni0.8Co0.15Al0.05O2 in the presence of electrolyte is the delayed phase transition from the spinel-type to the rock salt-type phase by stretching the temperature range of spinel phases from about 20 to 140 C. This unique behavior is considered as the key factor of the better thermal stability of the Li1-xNi1/3Co1/3Mn1/3O2 cathode materials.

15 GEOTHERMAL ENERGY↗

Time-resolved formation of uranium and silicon oxides subsequent to the laser ablation of U 3 Si 2

The early-time kinetic behavior of species in a plume produced from laser ablation of U 3 Si 2 in an environment containing 2% O 2 is characterized using time-resolved absorption spectroscopy. The UO band around 593.55 nm and the SiO band around 230 nm is observed as well as various atomic and ionic uranium transitions. Temperatures and concentrations of these species are tracked and reported as well.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of the upgraded single-line-of-sight time-resolved x-ray imager using short-pulse visible and UV lasers

The single-line-of-sight time-resolved x-ray imager (SLOS-TRXI), a fast-gated x-ray imager used for capturing x-ray self-emission in inertial confinement fusion experiments on OMEGA, has been upgraded and characterized. SLOS-TRXI combines an electron-dilation imager and a hybrid complementary metal–oxide–semiconductor (hCMOS) sensor to capture multiple gated frames on a single line of sight with a temporal resolution of ~40 ps and a spatial resolution of 10 µm. The original hCMOS sensor with four frames was replaced with a newer-generation hCMOS sensor having eight frames. Gate characterizations of both the sensor and the entire SLOS-TRXI diagnostic were performed using ~10-ps FWHM visible (2ω) and UV (4ω) short-pulse lasers, respectively. A stepped echelon was used to generate a train of five UV laser pulses having an interpulse separation of 30 ± 3 ps. Characterization results of the hCMOS gating (2.28 ± 0.02-ns FWHM on average) and a temporal resolution of the upgraded SLOS-TRXI (34 ± 4-ps FWHM on average) are presented. A temporal magnification for the electron-dilation imager between 40 and 60 was inferred from the characterization results. Furthermore, the spatial resolution of the upgraded SLOS-TRXI remains the same in light of this work.

47 OTHER INSTRUMENTATION↗

DATA-DRIVEN DISCOVERY OF DYNAMICS FROM TIME-RESOLVED COHERENT SCATTERING

This software implements a data-driven framework to uncover mechanistic models of dynamics directly from time-resolved coherent X-ray scattering measurements. It employs neural differential equations to parameterize unknown real-space dynamics and incorporates a computational scattering forward model to relate real-space predictions to reciprocal-space observations.

Zhou, Tao↗