Search NASA⌕ Search

SEARCH · Search NASA

Results for “vanadium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Thermoelasticity Model for Vanadium

Vanadium is a polymorphic (multi-phase) material. Its phase diagram contains two experimentally confirmed solid phases, body-centered cubic (bcc) and rhombohedral (R-3m).

36 MATERIALS SCIENCE↗

Ab initio equation of state for vanadium

Accurate materials’ equations of state (EOS) are essential for understanding materials properties as well as for use in multiphysics simulations. In particular, hydrodynamics simulations are based on three fundamental conservation laws (mass, momentum and energy) that form an under-determined system of equations. The equation of state serves as an additional closure relation between thermodynamic variables for a given material that enables numerical hydrodynamics simulation. In this report, we focus on the development of an ab initio EOS for the body centered cubic (BCC) phase of Vanadium (V) for eventual integration into a multiphase EOS in the OpenSesame EOS database.

36 MATERIALS SCIENCE↗

Titanium Nitride as an Intermetallic Diffusion Barrier for Hydrogen Permeation in Palladium–Vanadium Composite Membranes

Hydrogen purification is a critical industrial process, and there are ongoing efforts to develop low-cost alternatives to palladium foil membranes. Titanium nitride (TiN) is studied as an interdiffusion barrier to enable hydrogen permeation in composite palladium–vanadium membranes. TiN was deposited via reactive sputtering, and films with the desired (200) orientation were obtained in the metallic regime at 400 °C under a 200 V bias to the substrate. The permeability of thin-film TiN was determined with palladium-based sandwich structures. TiN layers up to 10 nm resulted in a minimal decrease in flux (~20%) relative to a freestanding PdCu foil, which was attributed to the interfacial resistance. At greater thicknesses, the TiN layer was rate-limiting, and it was found that the effective permeability of the sputtered TiN thin films was ~6 × 10−12 mol s−1 m−1 Pa−0.5. Composite Pd|TiN|V|TiN|Pd membranes exhibited permeability values up to three times greater than pure palladium, exhibiting stability at 450 °C for over 100 h, with the lack of intermetallic diffusion and alloy formation being confirmed with XRD. The membranes were unstable at 500 °C, which was attributed to the instability of the thin Pd layer and loss of catalytic activity.

Biochemistry & Molecular Biology↗

Irradiation effects on 17-7 PH stainless steel, A-201 carbon steel, and titanium-6-percent-aluminum-4-percent-vanadium alloy

Irradiation effects on three materials from the NASA Plum Brook Reactor Surveillance Program were determined. An increase of 105 K in the nil-ductility temperature for A-201 steel was observed at a fluence of approximately 3.1 x 10 to the 18th power neutrons/sq cm (neutron energy E sub n greater than 1.0 MeV). Only minor changes in the mechanical properties of 17-7 PH stainless steel were observed up to a fluence of 2 x 10 to the 21st power neutrons/sq cm (E sub n greater than 1.0 MeV). The titanium-6-percent-aluminum-4-percent-vanadium alloy maintained its notch toughness up to a fluence of 1 x 10 to the 21st power neutrons/sq cm (E sub n greater than 1.0 MeV).

Hasse, R. A.↗

Vanadium isotopic composition and concentrations of ferromagnesian elements in returned lunar samples

The effects are sought of an energetic charged particle irradiation of solar system material which is postulated as having taken place early in its history. A similar irradiation took place much more recently in the history of lunar samples and meteorites and this process is studied by means of a variety of monitors including highly sensitive noble gas nuclides, radionuclides, and tracks. Such monitors cannot be used to study the postulated early irradiation since it could have taken place under conditions such that these monitors were not retained or were subsequently lost. Accordingly, it is necessary that a nongaseous element be used to search for the effects of this irradiation, and one of the most sensitive of these is the vanadium isotopic composition. A comparative study is made of the 50 sub V/51 sub V ratios in 15 meteoritic, 5 terrestrial, and 11 lunar samples.

Lipschutz, M. E.↗

Selected fretting-wear-resistant coatings for titanium - 6-percent-aluminum - 4-percent-vanadium alloy

A titanium - 6-percent-aluminum - 4-percent-vanadium alloy (Ti-6Al-4V) was subjected to fretting-wear exposures against uncoated Ti-6Al-4V as a baseline and against various coatings and surface treatments applied to Ti-6Al-4V. The coatings evaluated included plasma-sprayed tungsten carbide with 12 percent cobalt, aluminum oxide with 13 percent titanium oxide, chromium oxide, and aluminum bronze with 10 percent aromatic polyester; polymer-bonded polyimide, polyimide with graphite fluoride, polyimide with molybdenum disulfide (MoS2), and methyl phenyl silicone bonded MoS2, preoxidation surface treatment, a nitride surface treatment, and a sputtered MoS2 coating. Results of wear measurements on both the coated and uncoated surfaces after 300,000 fretting cycles indicated that the polyimide coating was the most wear resistant and caused the least wear to the uncoated mating surface.

Bill, R. C.↗

Friction and wear of titanium alloys and copper alloys sliding against titanium 6-percent-aluminum - 4-percent-vanadium alloy in air at 430 C

Experiments were conducted to determine the friction and wear characteristics of aluminum bronzes and copper-tin, titanium-tin, and copper-silver alloys sliding against a titanium-6% aluminum-4% vanadium alloy (Ti-6Al-4V). Hemispherically tipped riders of aluminum bronze and the titanium and copper alloys were run against Ti-6Al-4V disks in air at 430 C. The sliding velocity was 13 cm/sec, and the load was 250 g. Results revealed that high tin content titanium and copper alloys underwent significantly less wear and galling than commonly used aluminum bronzes. Also friction force was less erratic than with the aluminum bronzes.

Wisander, D. W.↗