Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A semi-Lagrangian direct-interaction closure of the spectra of isotropic variable-density turbulence

A study of variable-density homogeneous stationary isotropic turbulence based on the sparse direct-interaction perturbation (SDIP) and supporting direct numerical simulations (DNS) is presented. The non-solenoidal flow considered here is an example of turbulent mixing of gases with different densities. The spectral statistics of this type of flow are substantially more difficult to understand theoretically than those of the similar solenoidal flows. In the approach described here, the nonlinearly coupled velocity and scalar (which determine the density of the fluid) equations are expanded in terms of a normalised density ratio parameter. A new set of coupled integro-differential SDIP equations are derived and then solved numerically for the first-order correction to the incompressible equations in the variable-density expansion parameter. By adopting a regular expansion approach, one obtains leading-order corrections that are universal and therefore interesting in their own right. The predictions are then compared with DNS of forced variable-density flow with different density contrasts. It is found that the velocity spectrum owing to variable density is indistinguishable from that of constant-density turbulence, as it is supported by a wealth of indirect experimental evidence, but the scalar spectra show significant deviations, and even loss of monotonicity, as a function of the type and strength of the large-scale source of the mixing. Furthermore, the analysis helps clarify what may be the proper approach to interpret the power spectrum of variable-density turbulence.

Mechanics↗

Techno-economic analyses of several redox flow batteries using levelized cost of energy storage

Development of inexpensive long-duration energy storage supports widespread deployment of variable renewable energy resources onto the electricity grid. Flow batteries are a promising class of devices for long-duration energy storage. Techno-economic modeling is needed to evaluate commercial feasibility of existing technologies and to help guide research and development of new technologies. Levelized cost of storage is a useful metric that accounts for capital and operating costs and energy throughput over the life of a project. This metric is used to compare the economic prospects of lithium ion to eight aqueous and two hypothetical nonaqueous flow batteries in four use cases. Finally, flow batteries with inexpensive active materials are favored in long-duration applications.

25 ENERGY STORAGE↗

EXCITATION OF TRAPPED WAVES IN SIMULATIONS OF TILTED BLACK HOLE ACCRETION DISKS WITH MAGNETOROTATIONAL TURBULENCE

We analyze the time dependence of fluid variables in general relativistic, magnetohydrodynamic simulations of accretion flows onto a black hole with dimensionless spin parameter a/M = 0.9. We consider both the cases where the angular momentum of the accretion material is aligned with the black hole spin axis (an untilted flow) and where it is misaligned by 15 deg. (a tilted flow). In comparison to the untilted simulation, the tilted simulation exhibits a clear excess of inertial variability, that is, variability at frequencies below the local radial epicyclic frequency. We further study the radial structure of this inertial-like power by focusing on a radially extended band at 118(M/10 M{sub sun}){sup -1} Hz found in each of the three analyzed fluid variables. The three-dimensional density structure at this frequency suggests that the power is a composite oscillation whose dominant components are an over dense clump corotating with the background flow, a low-order inertial wave, and a low-order inertial-acoustic wave. Our results provide preliminary confirmation of earlier suggestions that disk tilt can be an important excitation mechanism for inertial waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electroosmotic Flow Rectification in Membranes with Asymmetrically Shaped Pores: Effects of Current and Pore Density

We have recently demonstrated a new electrokinetic phenomenon—electroosmotic flow rectification in membranes with asymmetrically shaped pores. Flow rectification means that at constant driving force the flow rate in one direction through the membrane is faster than the flow rate in the opposite direction. EOF rectification could be of practical use in microfluidic devices incorporating porous membranes, but additional research is required. As such, we explore here the effects of two key experimental variables—current density used to drive flow through the membrane and membrane pore density—on EOF rectification. We have found that the extent of EOF rectification, as quantified by the rectification ratio, increases with increasing current density. In contrast, the rectification ratio decreases with increasing membrane pore density. We propose explanations for these results based on simple EOF and membrane-transport theories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees

With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat losses associated with the upward flow of air, water, CO 2 in geothermal production wells

This present work reports on the heat losses associated with the upward flow of hot air, water, and CO 2 in a production well. The heat losses considered here are the frictional heat loss, the gravitational heat loss, the Joule-Thomson effect, and the conduction heat loss to the surrounding rock formation. These heat losses were characterized using the mass flow rate, the operation time as variable parameters while the surrounding formation was assumed to have constant properties with a linear geothermal gradient. The results show that, the frictional heat loss was small while the influences of the others depended on the flow conditions and the operation time. For water, the Joule-Thomson effect was a heating effect and its magnitude was comparable to that due to the gravitational effect. The conduction heat loss was dominant for all situations. For air as well as CO 2 , the Joule-Thomson effects were the cooling effects. For low mass flow rates, the conduction heat loss was the dominant heat loss during the initial stages of the operation and the combined heat losses due to the gravitational and the Joule-Thomson effects became dominant during the later times. For high mass flow rates, throughout the operation life time, the gravitational and the Joule-Thomson effects were the dominant heat losses that control the temperature of air and CO 2 in the production well.

15 GEOTHERMAL ENERGY↗

Ocean Variability Beneath the Filchner-Ronne Ice Shelf Inferred From Basal Melt Rate Time Series

Fourteen phase-sensitive radars (ApRES) were deployed on the Filchner-Ronne Ice Shelf (FRIS) to measure variability in its basal melt rate. Melt rates from sites along the Ronne Depression vary seasonally, consistent with the dynamics of the propagation of seasonal dense water from the western ice front into the cavity. Several sites at the back of the FRIS cavity feature a signal with two seasonal maxima. Sub-ice shelf oceanographic data available from one of the sites indicate that this signal is caused by two different pathways followed by the same source water. Inter-annual variability is strongest along a direct flow pathway between western Ronne Ice Front and western Berkner Island. Highest melting occurred in 1999 and 2018, following anomalously low summer sea-ice concentrations in front of the ice shelf. Inter-annual melt rate variability at the back of the FRIS cavity is limited. If present, it is expressed as a suppression or delay in the arrival of the seasonal melt rate minimum, which can be understood in terms of inter-annual stratification changes and variable inflow pathways toward the sites. Long term mean ApRES melt rates agree with estimates from satellite data over eastern FRIS. However, the satellite estimates overstate the area of active basal freezing in the western part of the ice shelf. Furthermore, the temporal melt rate variability from the satellite estimates exaggerates the range of variability at both seasonal and inter-annual time scales with any correspondence between the in-situ and remotely derived inter-annual variability being limited to a single site.

54 ENVIRONMENTAL SCIENCES↗

Variable-density buoyancy-driven turbulence with asymmetric initial density distribution

The effects of different initial density distributions on the evolution of buoyancy-driven homogeneous variable-density turbulence (HVDT) at low (0.05) and high (0.75) Atwood numbers are studied by using high-resolution direct numerical simulations. HVDT aims to mimic the acceleration-driven Rayleigh–Taylor and shock-driven Richtmyer–Meshkov instabilities and reveals new physics that arise from variable-density effects on the turbulent mixing. Here, the initial amounts of pure light and pure heavy flows are altered primarily to mimic the variable-density turbulence at the different locations of the Rayleigh–Taylor and Richtmyer–Meshkov instabilities’ mixing layers where the amounts of the mixing fluids are not equal. It is found that for the low Atwood number cases, the asymmetric initial density distribution has limited effects on both global and local flow evolution for HVDT. However, at high Atwood number, both global flow evolution and the local flow structures are strongly affected by the initial composition ratio. The flow composed of more light fluid reaches higher turbulent levels and the local statistics reach their fully-developed behavior earlier in the time evolution. In contrast, during the late time decay, where most of the flow is well-mixed, all parameters become independent of the initial composition ratio for both low and high Atwood number cases.

42 ENGINEERING↗

Parsing Weather Variability and Wildfire Effects on the Post-Fire Changes in Daily Stream Flows: A Quantile-Based Statistical Approach and Its Application

Determining wildland fire impacts on streamflow can be problematic as the hydrology in burned watersheds is influenced by post-fire weather conditions. Here, this study presents a quantile-based analytical framework for assessing fire impacts on low and peak daily flow magnitudes, while accounting for post-fire weather influences. This framework entails (a) the bootstrap method to compute the relative change in the post-fire annual flow and weather statistics, (b) double mass analysis to detect if post-fire baseflow and quick-flow yield ratios are significantly altered, and (c) a quantile regression method to parse fire effects on flow at a specific quantile. We illustrate the applicability of this analytical framework using 44 western US streams with at least 5% of their watershed area burned. Results indicate that large, high-severity burns in upland watersheds can raise the streamflow magnitude at the 0. 05 th and 0. 95 th quantiles for at least the five post-fire years. Quantile regression results show that the median fire-related increase in flow for the five post-fire years can be up to 5,000% (Standard Error; S.E. < 2%) at the 0. 05 th E quantile and 161% (S.E. < 10%) at the 0. 95 th quantile. The fire-related increase in flow was often pronounced at the 0. 05 th quantile for streams in the Pacific Northwest and California regions. The difference in fire effects on flow (at both quantiles) across streams was related to post-fire weather, pyrology, physiography, and land cover. The proposed analytical framework can be useful for detecting and quantifying fire effects on the low and peak stream flows in burned watersheds without overlapping disturbances.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Shot-to-Shot In-Nozzle Flow Variations in a Heavy-Duty Diesel Injector Using Real Nozzle Geometry

Cyclic variability in internal combustion engines (ICEs) arises from multiple concurrent sources, many of which remain to be fully understood and controlled. This variability can, in turn, affect the behavior of the engine resulting in undesirable deviations from the expected operating conditions and performance. Shot-to-shot variation during the fuel injection process is strongly suspected of being a source of cyclic variability. This study focuses on the shot-to-shot variability of injector needle motion and its influence on the internal nozzle flow behavior using diesel fuel. High-speed x-ray imaging techniques have been used to extract high-resolution injector geometry images of the sac, orifices, and needle tip that allowed the true dynamics of the needle motion to emerge. These measurements showed high repeatability in the needle lift profile across multiple injection events, while the needle radial displacement was characterized by a much higher degree of randomness. A robust and previously validated computational setup from the authors’ research group using a commercial computational fluid dynamics (CFD) code has been adapted for the eight-hole heavy-duty common-rail diesel injector used for the measurements. The simulation results obtained using the x-ray-scanned geometry have been validated against available experimental data of mass flow rate at the nozzle exit. The fuel mass flow rate has then been analyzed at three different injection pressures that cover the conditions at which the injector typically operates during normal engine operation. Finally, the average off-axis motion of the needle has been perturbed (based on the variability found in the experimental measurements) to generate three new cases that present different amplitude and phasing of the radial displacement with respect to the baseline average motion. Furthermore, this revealed the effects of off-axis motion on shot-to-shot and orifice-to-orifice variations.

42 ENGINEERING↗

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings

A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting Deposition Rate and Closing the Loop on Aerosol Jet Printing with In‐Line Light Scattering Measurements

Aerosol jet printing is a compelling noncontact, digital manufacturing technology for flexible, hybrid, and conformal electronics, but batch‐to‐batch variability and process drift inhibit systematic study and translation to production environments. Emerging measurement techniques for the aerosol volume fraction, a key parameter governing deposition rate, have shown promise for real‐time response, including a recent demonstration of human‐in‐the‐loop control. By integrating improved light scattering measurements with custom software, a robust environment for real‐time monitoring is established and fully automated closed‐loop control over the deposition rate during printing is enabled. The physical basis for scattering measurements as a feedback source is examined and the quantitative insight this provides for ink development and fundamental process studies is highlighted. Three candidate process variables for closed‐loop control, namely the atomizer voltage, carrier gas flow rate, and print speed, are then evaluated. The atomizer voltage demonstrates the best extended duration validity because it addresses atomization variability directly, but carrier gas flow rate and print speed provide faster and more deterministic responses. This methodology is then demonstrated for electrical properties using a silver nanoparticle ink, maintaining 98% of printed patterns within 10% of the mean resistance value over 3 h of printing.

36 MATERIALS SCIENCE↗

The role of electron heating physics in images and variability of the Galactic Centre black hole Sagittarius A*

The accretion flow around the Galactic Centre black hole Sagittarius A* (Sgr A*) is expected to have an electron temperature that is distinct from the ion temperature, due to weak Coulomb coupling in the low-density plasma. We present four two-temperature general relativistic radiative magnetohydrodynamic (GRRMHD) simulations of Sgr A* performed with the code KORAL. These simulations use different electron heating prescriptions, motivated by different models of the underlying plasma microphysics. We compare the Landau-damped turbulent cascade model used in a previous work with a new prescription we introduce based on the results of particle-in-cell simulations of magnetic reconnection. With the turbulent heating model, electrons are preferentially heated in the polar outflow, whereas with the reconnection model electrons are heated by nearly the same fraction everywhere in the accretion flow. The spectra of the two models are similar around the submillimetre synchrotron peak, but the models heated by magnetic reconnection produce variability more consistent with the level observed from Sgr A*. All models produce 230 GHz images with distinct black hole shadows which are consistent with the image size measured by the Event Horizon Telescope, but only the turbulent heating produces an anisotropic ‘disc-jet’ structure where the image is dominated by a polar outflow or jet at frequencies below the synchrotron peak. None of our models can reproduce the observed radio spectral slope, the large near-infrared and X-ray flares, or the near-infrared spectral index, all of which suggest non-thermal electrons are needed to fully explain the emission from Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomaly Detection in Liquid Sodium Cold Trap Operation with Multisensory Data Fusion Using Long Short-Term Memory Autoencoder

Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3-D Unsteady Model for Be-Steam Reaction in Water-Cooled Ceramic Breeder Blanket

Here, the design of the water-cooled ceramic breeder (WCCB) blanket includes beryllium multiplier layers. At elevated temperature, beryllium reacts with steam in an exothermic reaction producing beryllium oxide and hydrogen. Such situation may occur in WCCB in the case of the rupture of one of the cooling pipes in the blanket module. This process occurs locally in a complex 3-D geometry of the blanket containing several different granular levels and a network of cooling pipes and structural supports. The process is also inherently unsteady since reaction rate depends on concentration of steam and pure beryllium which changes in time. In order to perform the detailed analysis of the process, the model of the reacting flowthrough porous media was developed and introduced into 3-D computational fluid dynamics code. In this model, granular beds are introduced as porous solids simplifying the model geometry and reducing typical mesh size to manageable amount of tens of millions of elements. A reaction rate between solid beryllium and steam is obtained from experimental results, and depends on temperature and concentration of the reactants. The differential equation for beryllium oxide fraction is introduced, allowing obtaining distributions of beryllium oxide in space and time. Multicomponent flow consisting of a homogenous mixture of steam and hydrogen is considered flowing through the porous solid with variable properties. Sink and source terms for steam and hydrogen fractions are determined by local beryllium oxide mass fraction source according to the molar ratios of beryllium steam reaction. The conjugated heat transfer approach is applied to calculate heat transfer in support structures as well as coolant flow, simultaneously with the porous medium steam flow in a blanket's granular beds. The model is validated using experimental data on beryllium steam reaction for granular bed samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theory of Intermittent Cutting. 3. Description of Tool Exit from the Blank

Vorontsov’s plastic-flow method permits the derivation of a model of cutting for the region where the tool exits the blank. The stress–strain state of the blank is determined, and the dimensions of the plastic-deformation zone are calculated. The main cutting parameters are shown to be variable.

42 ENGINEERING↗

A logical progression of steps for implementation and testing of the 7-equation, two-phase model into a computational framework

A seven-step progression is given for the implementation of the seven-equation model, employed in the new RELAP-7 thermal hydraulics system analysis code, within the MOOSE-compatible framework. The model is well-posed and treats both phases as compressible flow in a one-dimensional, variable cross-sectional area duct/pipe/component. Some appropriate tests are also outlined to benchmark the model/implementation for each step of the progression. (authors)

97 MATHEMATICS AND COMPUTING↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗