Search NASA⌕ Search

SEARCH · Search NASA

Results for “water supply systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Life support approaches for Mars missions

Life support approaches for Mars missions are evaluated using an equivalent system mass (ESM) approach, in which all significant costs are converted into mass units. The best approach, as defined by the lowest mission ESM, depends on several mission parameters, notably duration, environment and consequent infrastructure costs, and crew size, as well as the characteristics of the technologies which are available. Generally, for the missions under consideration, physicochemical regeneration is most cost effective. However, bioregeneration is likely to be of use for producing salad crops for any mission, for producing staple crops for medium duration missions, and for most food, air and water regeneration for long missions (durations of a decade). Potential applications of in situ resource utilization need to be considered further. c2002 Published by Elsevier Science Ltd on behalf of COSPAR.

NASA Discipline Life Support Systems↗

Spatial distribution of total, ammonia-oxidizing, and denitrifying bacteria in biological wastewater treatment reactors for bioregenerative life support

Bioregenerative life support systems may be necessary for long-term space missions due to the high cost of lifting supplies and equipment into orbit. In this study, we investigated two biological wastewater treatment reactors designed to recover potable water for a spacefaring crew being tested at Johnson Space Center. The experiment (Lunar-Mars Life Support Test Project-Phase III) consisted of four crew members confined in a test chamber for 91 days. In order to recycle all water during the experiment, an immobilized cell bioreactor (ICB) was employed for organic carbon removal and a trickling filter bioreactor (TFB) was utilized for ammonia removal, followed by physical-chemical treatment. In this study, the spatial distribution of various microorganisms within each bioreactor was analyzed by using biofilm samples taken from four locations in the ICB and three locations in the TFB. Three target genes were used for characterization of bacteria: the 16S rRNA gene for the total bacterial community, the ammonia monooxygenase (amoA) gene for ammonia-oxidizing bacteria, and the nitrous oxide reductase (nosZ) gene for denitrifying bacteria. A combination of terminal restriction fragment length polymorphism (T-RFLP), sequence, and phylogenetic analyses indicated that the microbial community composition in the ICB and the TFB consisted mainly of Proteobacteria, low-G+C gram-positive bacteria, and a Cytophaga-Flexibacter-Bacteroides group. Fifty-seven novel 16S rRNA genes, 8 novel amoA genes, and 12 new nosZ genes were identified in this study. Temporal shifts in the species composition of total bacteria in both the ICB and the TFB and ammonia-oxidizing and denitrifying bacteria in the TFB were also detected when the biofilms were compared with the inocula after 91 days. This result suggests that specific microbial populations were either brought in by the crew or enriched in the reactors during the course of operation.

NASA Discipline Life Support Systems↗

Decision making for implementing non-traditional water sources: a review of challenges and potential solutions

Abstract The effects of climate change, population growth, and future hydrologic uncertainties necessitate increased water conservation, new water resources, and a shift towards sustainable urban water supply portfolios. Diversifying water portfolios with non-traditional water sources can play a key role. Rooftop harvested rainwater (RHRW), atmospheric and condensate harvesting, stormwater, recycled wastewater and greywater, and desalinated seawater and brackish water are all currently utilized and rapidly emerging non-traditional water sources. This review explores the status and trends around these non-traditional water sources, and reviews approaches and models for prioritizing, predicting, and quantifying metrics of concern. The analysis presented here suggests that understanding the challenges of location specific scenarios, socioeconomic knowledge gaps, water supply technologies, and/or water management structure is the crucial first step in establishing a model or framework approach to provide a strategy for improvement going forward. The findings of this study also suggest that clear policy guidance and onsite maintenance is necessary for variable water quality concerns of non-traditional sources like harvested rainwater and greywater. In addition, use of stormwater or reuse of wastewater raises public health concerns due to unknown risks and pathogen levels, thus rapid monitoring technologies and transparent reporting systems can facilitate their adoption. Finally, cost structure of desalination varies significantly around the world, largely due to regulatory requirements and local policies. Further reduction of its capital cost and energy consumption is identified as a hurdle for implementation. Overall, models and process analyses highlight the strength of comparative assessments across scenarios and water supply options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of an algae-based CELSS. Part 1: model development

A steady state chemical model and computer program have been developed for a life support system and applied to trade-off studies. The model is based on human demand for food and oxygen determined from crew metabolic needs. The model includes modules for water recycle, waste treatment, CO2 removal and treatment, and food production. The computer program calculates rates of use and material balance for food. O2, the recycle of human waste and trash, H2O, N2, and food production supply. A simple non-iterative solution for the model has been developed using the steady state rate equations for the chemical reactions. The model and program have been used in system sizing and subsystem trade-off studies of a partially closed life support system.

Models, Chemical↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

Bahar, Bamdad↗

Membrane-Based Air Dehumidification Using Organic Ionic Liquid Desiccant

Membrane Ionic Liquid Desiccant Air Dehumidification (MILDAD) is a promising alternative to conventional dehumidification systems that employ mechanical compressors and refrigerant-based cooling with evaporator and condensing coils. However, its application has been limited due to high manufacturing and installation cost, durability issues, concerns with corrosion due to leakage and salt carry over into the downstream air and onto surfaces. This paper reviews substantial progress made with new systems based on combining advanced ionic membranes that are pressure resistant, thin walled with high water permeability, and non-porous with synthetic organic, non-crystalline ionic liquid desiccants. Alternative design configurations are discussed comparing cross flow shell-and-tube membrane contactors employing ionic membrane tubes through which ionic liquid desiccant air flows. Performance data for MILDAD prototypes is provided. Dehumidification of the incoming supply airstream and regeneration into exhausted building air is demonstrated. The latent effectiveness of the MILDAD system will be discussed along with some future steps to improve performance of the system.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Late quaternary time series of Arabian Sea productivity: Global and regional signals

Modern annual floral and faunal production in the northwest Arabian Sea derives primarily from upwelling induced by strong southwest winds during June, July, and August. Indian Ocean summer monsoon winds are, in turn, driven by differential heating between the Asian continent and the Indian ocean to the south. This differential heating produces a strong pressure gradient resulting in southwest monsoon winds and both coastal and divergent upwelling off the Arabian Peninsula. Over geologic time scales (10(exp 4) to 10(exp 6) years), monsoon wind strength is sensitive to changes in boundary conditions which influence this pressure gradient. Important boundary conditions include the seasonal distribution of solar radiation, global ice volume, Indian Ocean sea surface temperature, and the elevation and albedo of the Asian continent. To the extent that these factors influence monsoon wind strength, they also influence upwelling and productivity. In addition, however, productivity associated with upwelling can be decoupled from the strength of the summer monsoon winds via ocean mechanisms which serve to inhibit or enhance the nutrient supply in the intermediate waters of the Indian Ocean, the source for upwelled waters in the Arabian Sea. To differentiate productivity associated with wind-induced upwelling from that associated with other components of the system such as nutrient sequestering in glacial-age deep waters, we employ a strategy which monitors independent components of the oceanic and atmospheric subsystems. Using sediment records from the Owen Ridge, northwest Arabian Sea, we monitor the strength of upwelling and productivity using two independent indicators, percent G. bulloides and opal accumulation. We monitor the strength of southwest monsoon winds by measuring the grain-size of lithogenic dust particles blown into the Arabian Sea from the surrounding deserts of the Somali and Arabian Peninsulas. Our current hypothesis is that the variability associated with the 41 kyr power in the G. bulloides and opal accumulation records derive from nutrient availability in the intermediate waters which are upwelled via monsoon winds. This hypothesis is testable by comparison with Cd records of intermediate and deep waters of the Atlantic and Indian Ocean.

Clemens, Steven C.↗

Assembly and integration of the Space Station Freedom ECLSS

The assembly and integration of the SSF elements and systems throughout the build-up sequence are addressed focusing on ECLSS hardware interfaces and stage performance. The ECLSS encompasses six subsystems which provide temperature and humidity control, atmospheric control and supply, atmospheric revitalization, water recovery and management, waste management, and the fire detection and protection.

Gould, M. J.↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Design, fabrication and systems integration of a satellite tracked, free-drifting ocean data buoy

Engineering details are presented of a small free-drifting buoy configuration designed for use in the study of continental shelf water circulation patterns in the Chesapeake Bight of the Western North Atlantic Ocean. The buoy incoporated French instrumentation and was interrogated by the French EOLE satellite to provide position and four channels of temperature data. The buoy design included a variable depth drogue and a power supply sufficient for six weeks of continuous operations. Proof tests of the configuration indicated an adequate design and subsequent field experiments verified the proper functioning of the system.

Wallace, J. W.↗

Weightlessness simulation system and process

A weightlessness simulator has a chamber and a suit in the chamber. O-rings and valves hermetically seal the chamber. A vacuum pump connected to the chamber establishes a pressure in the chamber less than atmospheric pressure. A water supply tank and water supply line supply a body of water to the chamber as a result of partial vacuum created in the chamber. In use, an astronaut enters the pressure suit through a port, which remains open to ambient atmosphere, thus supplying air to the astronaut during use. The pressure less than atmospheric pressure in the chamber is chosen so that the pressure differential from the inside to the outside of the suit corresponds to the pressure differential with the suit in outer space.

Vykukal, Hubert C.↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

The Modeling of Synfuel Production Process: ASPEN Model of FT production with electricity demand provided at LWR scale

Synfuels, or electro-fuels (e-fuels) have the unique potential to significantly reduce greenhouse gas (GHG) emissions across the transportation sector. This is especially true for applications with substantial payloads and daily miles traveled, such as long-haul heavy-duty vehicles, rail locomotives, marine vessels and aviation aircrafts that are challenging to directly electrify via battery or fuel cell powertrain technologies. Synfuels, or electro-diesel/electro-jet fuels, have similar properties with the incumbent petroleum fuels, compatible with current infrastructure but have much lower GHG emissions relative to the petroleum counterpart, because they utilize waste carbon dioxide (CO2) streams and green hydrogen (H2) sourced from electrolysis. To achieve substantial reductions in GHG emissions, electricity sources must be zero carbon or near-zero carbon, which is the case with solar, wind, hydro and nuclear power. Compared to the intermittency of solar, wind and hydro, nuclear energy provides a steady energy source. In addition, it’s advantageous for nuclear power to produce synfuels because it provides not only near-zero carbon electricity to displace grid electricity, but also near-zero carbon steam to displace carbon-intensive natural gas combustion for steam generation. The availability of electricity and steam also enables more efficient green hydrogen production by using high-temperature electrolysis. In this work, Argonne National Laboratory (ANL) models a synfuel production process via the Fischer- Tropsch (FT) reaction by using nuclear power to provide electricity and steam. In 2021, using ASPEN Plus software, ANL established a detailed process model of a stand-alone FT production facility, assuming feedstocks of pure CO2 and H2. This stand-alone model can be expanded to integrate H2 production from nuclear power via low-temperature and high-temperature electrolysis at light-water reactor (LWR) scale. This report summarizes the stand-alone ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 351 MT/day (130,000 gal/day) of FT fuel (a mixture of naphtha, jet fuel, and diesel) by converting 223 MT/day of H2 and 2,387 MT/day of CO2. The FT fuel production energy efficiency is 58% and the carbon conversion efficiency (from CO2 to FT fuel) is 46%. The production of green hydrogen requires 390–470 MWe of electricity, which is compared with the capacity of an LWR plant. For the stand-alone FT process, the detailed energy demand (electricity and heat) is summarized in the table below. Based on the energy supply source and the required temperature, potential insertion points of nuclear energy are identified. Based on the potential nuclear energy utilization, this report discusses potential modification options for expanding the system boundary to integrate nuclear power use, for example on-site hydrogen production via water electrolysis. Modeling of the integrated system is conducted by closely working with ANL and Idaho National Laboratory (INL) collaborators to harmonize design parameters of nuclear plants and the FT production process.

Zang, Guiyan↗

Ecological considerations for possible Martian biota

Current climatic and geological evidence suggests that, like early Earth, conditions on ancient Mars may also have been favorable for the origin and evolution of life. The primordial atmospheres of the two planets were quite similar, composed primarily of CO2, N2, and water vapor at a total atmospheric pressure of approximately 1 bar. Each of these gases are important for the evolution of biological systems. With the exception of nitrogen, there seems to have been a sufficient supply of the biogenic elements C, H, O, P, and S (CHOPS) on early Mars for life to have evolved. It was postulated that primordial Mars contained only 18 mb of nitrogen in the form of N2 given that only fixed nitrogen is utilized by living systems. Laboratory tests performed at a total pressure of 1 bar and various partial pressures of dinitrogen (pN2 1-780 mb) show that nitrogen fixing organisms grow at pN2's of 18 mb or less, although the biomass and growth rates are decreased. The calcualted in vivo Km's ranged from 46 mb to 130 mb. If organisms adapted on Earth to a pH2 of 780 mb are capable of growing at these low partial pressures, it is conceivable that nitrogen was not the limiting factor in the evolution of life on early Mars.

Klingler, June M.↗

Status of the US Space Station ECLSS and internal TCS

The U.S. Space Station includes many elements and systems. Responsibility for these have been delegated to four NASA centers via a work packaging concept. Marshall Space Flight Center (MSFC) is responsible for work package one (WPOI) which includes the habitation, laboratory modules, the logistic carrier elements, as well as the environmental control and life support system (ECLSS), the internal thermal control system (ITCS), and the internal audio and video systems. Current status of the ECLSS and internal thermal are the subjects of this paper. The ECLSS is composed of six subsystem groups: the temperature humidity control, the atmosphere control and supply, the air revitalization, water reclamation and management, fecal waste management, and the fire detection and suppression subsystems. The internal TCS consists of all WP01 elements of passive and active thermal measures. The ECLSS and ITCS provide services for the permanently orbiting pressurized modules as well as the pressurized and unpressurized logistics carriers. The logistics carriers are used as ground-to-station ferries for both resupply and initial delivery of selected new equipment and later replacement items. Equipment, which cannot be subjected to the rigors of the space environment, will be carried in the pressurized logistic carrier; while an unpressurized carrier is used to resupply other commodities, such as external fluid consumables. The laboratory module houses the equipment for both payloads and subsystem maintenance and repair. The habitation module is dedicated to providing living and sleeping quarters including a galley, sleeping provisions, hygiene facilities, medical services as well as services for exercise and relaxation. The four nodes that join the two modules at their ends also house electronics as well as work stations and outside viewing cupolas. The airlocks, one providing an emergency hyperbaric chamber capability, are also attached. This assembly constitutes the U.S. provided portion of the initial station. Additional international modules and docking provisions for future attached pressurized payload as well as dual logistic module and growth capabilities are also provided. The primary heat rejection mechanism is achieved via a central set of radiators provided by another work package. The interface with the central TCS at the module heat exchangers defines the active control interface boundary of the ITCS with the central TCS. All internal cooling of the permanent orbital elements are provided via internal active fluid loops within the elements utilizing water as the transport media. Cabin and equipment cooling are provided by forced air flow and cold plate heat sinks. A special active cooling loop is provided in the laboratory module to accommodate experiments and other payloads. Coatings and insulation are used in conjunction with the active components to passively limit heat losses/gains. The most challenging ECLSS new technology issues relate to oxygen and water recovery. Closure of the oxygen loop requires the use of new regenerative CO 2 removal and concentration techniques, CO 2 reduction to convert the CO 2 to water with a waste by-product, and the electrolysis of water to produce breathing oxygen for water recovery. For water recovery three separate loops are currently planned. One loop provides potable water by utilizing a combination of recovered condensate and CO 2 reduction water. A second loop purifies hygiene water from waste from the showers, clothes washer, hygiene/hand wash stations and a dishwasher. The third loop provides hygiene water by the reclamation and purification of urine water. This paper outlines the basic services provided by the ECLSS and ITCS and describes the ECLSS functional distribution throughout the pressurized assembly.

R. Humphries↗

Germination and elongation of flax in microgravity

This experiment was conducted as part of a risk mitigation payload aboard the Space Shuttle Atlantis on STS-101. The objectives were to test a newly developed water delivery system, and to determine the optimal combination of water volume and substrate for the imbibition and germination of flax (Linum usitatissimum) seeds in space. Two different combinations of germination paper were tested for their ability to absorb, distribute, and retain water in microgravity. A single layer of thick germination paper was compared with one layer of thin germination paper under a layer of thick paper. Paper strips were cut to fit snugly into seed cassettes, and seeds were glued to them with the micropyle ends pointing outward. Water was delivered in small increments that traveled through the paper via capillary action. Three water delivery volumes were tested, with the largest (480 microliters) outperforming the 400 microliters and 320 microliters volumes for percent germination (90.6%) and root growth (mean=4.1 mm) during the 34-hour spaceflight experiment. The ground control experiment yielded similar results, but with lower rates of germination (84.4%) and shorter root lengths (mean=2.8 mm). It is not clear if the roots emerged more quickly in microgravity and/or grew faster than the ground controls. The single layer of thick germination paper generally exhibited better overall growth than the two layered option. Significant seed position effects were observed in both the flight and ground control experiments. Overall, the design of the water delivery system, seed cassettes and the germination paper strip concept was validated as an effective method for promoting seed germination and root growth under microgravity conditions. c2003 COSPAR. Published by Elsevier Ltd. All rights reserved.

Non-NASA Center↗

Carbonate petrography, kerogen distribution, and carbon and oxygen isotope variations in an early Proterozoic transition from limestone to iron-formation deposition, Transvaal Supergroup, South Africa

The transition zone comprises Campbellrand microbialaminated (replacing "cryptalgalaminate") limestone and shale, with minor dolomite, conformably overlain by the Kuruman Iron Formation of which the basal part is characterized by siderite-rich microbanded iron-formation with minor magnetite and some hematite-containing units. The iron-formation contains subordinate intraclastic and microbialaminated siderite mesobands and was deposited in deeper water than the limestones. The sequence is virtually unaltered with diagenetic mineral assemblages reflecting a temperature interval of about 110 degrees to 170 degrees C and pressures of 2 kbars. Carbonate minerals in the different rock types are represented by primary micritic precipitates (now recrystallized to microsparite), early precompactional sparry cements and concretions, deep burial limpid euhedral sparites, and spar cements precipitated from metamorphic fluids in close contact with diabase sills. Paragenetic pathways of the carbonate minerals are broadly similar in all lithofacies with kerogen intimately associated with them. Kerogen occurs as pigmentation in carbonate crystals, as reworked organic detritus in clastic-textured carbonate units, and as segregations of kerogen pigment around late diagenetic carbonate crystals. Locally kerogen may also be replaced by carbonate spar. Carbon isotope compositions of the carbonate minerals and kerogen are dependent on their mode of occurrence and on the composition of the dominant carbonate species in a specific lithofacies. Integration of sedimentary, petrographic, geochemical, and isotopic results makes it possible to distinguish between depositional, early diagenetic, deep burial, and metamorphic effects on the isotopic compositions of the carbonate minerals and the kerogen in the sequence. Major conclusions are that deep burial thermal decarboxylation led to 13C depletion in euhedral ferroan sparites and 13C enrichment in kerogen (organic carbon). Metamorphic sparites are most depleted in 13C. Carbonates in oxide-rich iron-formations are more depleted in 13C than those in siderite-rich iron-formation whereas the kerogens in oxide banded iron-formations (BIF) are more enriched. This implies that the siderite-rich iron-formations were not derived from oxide-rich iron-formation through reduction of ferric iron by organic matter. Organic matter oxidation by ferric iron did, however, decrease the abundance of kerogen in oxide-rich iron-formation and led to the formation of isotopically very light sparry carbonates. Siderite and calcmicrosparite both represent recrystallized primary micritic precipitates but differ in their 13C composition, with the siderites depleted in 13C by 4.6 per mil on average relative to calcmicrosparite. This means that the siderites were precipitated from water with dissolved inorganic carbon depleted in 13C by about 9 per mil relative to that from which the limestones precipitated. This implies an ocean system stratified with regard to total carbonate, with the deeper water, from which siderite-rich iron-formation formed, depleted in 13C. Iron-formations were deposited in areas of very low organic matter supply. Depletion of 13C may, therefore, derive not from degradation of organic matter but from hydrothermal activity, a conclusion which is supported by 18O composition of the carbonate minerals and trace element and rare earth element (REE) compositions of the iron-formations.

NASA Discipline Number 52-30↗