Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Investigation of the Hydrogen Release Incident at the AC Transit Emeryville Facility (Revised)

This report summarizes the investigation of the release of approximately 300kg of hydrogen at the AC Transit Facility in Emeryville, CA. The hydrogen release was avoidable in both the root cause and contributing factors. The report summarizes the findings of the incident investigation and metallurgical analysis of the failed valve. Hydrogen embrittlement, manufacturing quality as well as miscommunication played significant roles in the event. No injuries or fatalities resulted from the incident. This report includes additions and corrections to the initial report, SAND 2012-5170.

08 HYDROGEN↗

Investigation of the hydrogen release incident at the AC Transit Emeryville Facility.

This report summarizes the investigation of the release of approximately 300kg of hydrogen at the AC Transit Facility in Emeryville, CA. The hydrogen release was avoidable in both the root cause and contributing factors. The report highlights the need for communication in all phases of project planning and implementation. Apart from the failed valve, the hydrogen system functioned as designed, venting the hydrogen gas a safe distance above surrounding structures and keeping the subsequent fire away from personnel and equipment. The Emeryville Fire Department responded appropriately given the information provided to the Incident Commander. No injuries or fatalities resulted from the incident.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous Energy Source (120 Volts AC)

On September 25, 2013, a Health Physics Technician (HPT) was performing preparations to support a pneumatic transfer from the HFEF Decon Cell to the Room 130 Glovebox in HFEF, per HFEF OI 3165 section 3.5, Field Preparations. This activity involves an HPT setting up and climbing a portable ladder to remove the 14-C meter probe from above ball valve HBV-7. The HPT source checks the meter and probe and then replaces the probe above HBV-7, which is located above Hood ID# 130 HP. At approximately 13:20, while reaching past the HBV-7 valve position indicator switches in an attempt to place the 14-C meter probe in the desired location, the HPT’s left forearm came in contact with one of the three sets of exposed terminals on the valve position indication switches for HBV 7. This resulted in the HPT receiving an electrical shock from a 120 Volt AC source. Upon moving the arm, following the electrical shock, the HPT noticed two exposed electrical connections on a switch. The HPT then notified the HFEF HPT Supervisor, who in turn notified the MFC Radiological Controls Manager and HFEF Operations Manager of the situation. Work was stopped in the area and the hazard was roped off and posted to prevent access to the hazard. The HPT was escorted by the HPT Supervisor to the MFC Dispensary and then preceded to CFA medical for further evaluation. The individual was evaluated and released without any medical restrictions. Causal Factor (Root Cause) A3B3C01/A5B2C08: - Knowledge based error/Attention was given to wrong issues - Written Communication content LTA, Incomplete/situation not covered The Causal Factor (root cause) was attention being given to the wrong issues during the creation, reviews, verifications, and actual performance of HFEF OI-3165, which covers the need to perform the weekly source check and ensure placement of the probe prior to performing a “rabbit” transfer. This resulted in the hazard not being identified and mitigated in the procedure. Work activities with in HFEF-OI-3165 placed the HPT in proximity of an unmitigated hazard directly resulting in this event. Contributing Factor A3B3C04/A4B5C04: - Knowledge Based Error, LTA Review Based on Assumption That Process Will Not Change - Change Management LTA, Risks/consequences associated with change not adequately reviewed/assessed Prior to the pneumatic system being out of service, the probe and meter were not being source checked together. The source check issue was identified and addressed during the period of time when the system was out of service. The corrective actions for this issue resulted in the requirement that a meter and probe be source checked together as it is intended to be used. This changed the activity and required an HPT to weekly, when in use, remove and install the probe from above HBV-7 to meet the requirement of LRD 15001 Part 5 Article 551.5. Risks and consequences associated with this change were not adequately reviewed or assessed. Failure to identify the hazard associated with this change directly contributed to this event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of the 226 Ra- 230 Th- 234 U and 227 Ac- 231 Pa- 235 U radiochronometers to UF 6 Cylinders

Uranium-series radiometric dating was performed on two well-pedigreed UF 6 cylinder samples containing highly enriched uranium that were in use at the Portsmouth Gaseous Diffusion Plant between the mid-1970s and mid-1980s. Daughter-parent (i.e. 231 Pa- 235 U, 230 Th- 234 U) radiometric ages determined on solid heel materials (e.g. UO 2 F 2 , UF 4 ) recovered from the emptied cylinders resulted in unrealistically old ages due to the preferential sequestration of progeny isotopes within the solid heels. However, limited elemental fractionation amongst the progeny isotopes themselves in the heel material allowed for useful age constraints on the fill dates of the UF6 cylinders to be extracted from the granddaughter-daughter systems (i.e. 226 Ra- 230 Th, 227 Ac- 231 Pa).

07 ISOTOPE AND RADIATION SOURCES↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications – Acquire Nortek Residential AC/HP Units for Evaluation and Model the Units Using HPDM

For the upcoming refrigerant transition from HFCs to minorly flammable HFO refrigerants (A2L), refrigerant charge reduction is important to mitigate the fire hazard. Microchannel heat exchangers (MHXs) are a mature technology, which is effective in reducing system charge while maintaining similar heat transfer performance. MHXs will be applied more widely when the new refrigerants are used. Prior studies of the A2L HFO blends were mostly focused on fin-and-tube coils (FTC). An in-depth study for an air conditioner (AC)/heat pump (HP) system using all microchannel heat exchangers is still lacking. In FY19, a side-to-side comparison will be conducted between two residential split heat pumps, one using all FTCs and the other using all MHXs for drop-in investigation, to identify potential issues for future design. The two heat pumps have similar rated capacity, SEER, HSPF levels, similar fan, blower and compressor, but differ in heat exchangers. Both the HPs use two-stage compressors to facilitate investigating different refrigerant flow rates. We will drop-in HFO refrigerants (replacements for R-410A, e.g. R452B, R447B, R32, etc.). The experiments will reveal the potential of MHXs for charge reduction, and how the two systems using A2L refrigerants operate under standard SEER and HSPF rating conditions. The two units were donated by our partner, i.e. Nortek Global HVAC, an industry leader in making heat pumps using all MHXs as well as FTCs. The units were shipped to ORNL this week, and the product design data were also shared for modeling the two units using HPDM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Circuitry Design for ChIMES AC Drive Coil

This paper describes the technical aspects for development of the function generator and power amplifier components of the AC Drive coil on the ChIMES sensor. This will significantly aid in miniaturization of the entire sensor system. This paper only documents the two components mentioned, however with the design specifications laid out here, the rest of the circuitry can be miniaturized and made to be compatible with these components more easily than could be done previously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide Bandgap Solid State Circuit Breakers for AC and DC Microgrids

The objective of the project is to develop a new class of ultrafast, self-powered, programmable, autonomously operated, bidirectional solid state circuit breakers (SSCBs) using wide band gap (WBG) semiconductors with 1000X reduction in response time and 5X reduction in cost in comparison to commercial mechanical circuit breakers. In particular, we have developed two SSCB prototypes of 380VDC/220VAC/20A and 1000VDC/10A using GaN power switches for common distribution-level AC and DC voltages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Prototyping, Fabrication and Test of the Mu2e AC-Dipole Magnet

Fermilab Magnet Systems is building three High-frequency AC-Dipole Magnets for the Mu2e experiment at Fermilab. These magnets are composed of three single-loop one-meter-long ferrite loaded segments. The excitation consists of a copper tube, which is also used as a means for its cooling with the inherited challenges of Voltage and Frequency uncoupling. These magnets are designed to operate either at 300 kHz or 4.4 MHz via resonance tuning. Following the completion of the design, prototyping, and analysis phases, all ferrites and other components were procured, and the magnets were fabricated to meet vacuum compatibility requirements using strict procedures. Each magnet undergoes thorough baking and testing before being installed in the experiment. This paper discusses the magnets' role in proton background suppression as it represents a unique and essential device for the Mu2e experiment at Fermilab. We present the magnet design choices, modeling approach, and the challenges encountered during fabrication. Additionally, we outline the power supply driving mechanism, the testing that was performed, and our results.

Elementi, Luciano [Fermilab] (ORCID:00000002766372↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LLRF System for the Fermilab Mu2e Project – AC Dipole Extinction

The Mu2e experiment measures the conversion rate of muons into electrons. The experiments requires 53 MHz batches of 8 GeV protons to be re-bunched into 150 ns, 2.5 MHz pulses for extraction to a single RF cavity running at 2.36 MHz. To meet stringent limits on the amount of beam between pulses, an Extinction System is used comprising of 2 AC dipole magnets (4.4MHz, 296Khz) and a collimator.

Guran, M. [Fermilab] (ORCID:0009000235538559)↗

ACS Symposium Support

The funds from this DOE grant were used to help cover the travel costs of five students and postdoctoral fellows who attended a symposium on 'Hydration: From Clusters to Aqueous Solutions' held at the Fall 2007 American Chemical Society Meeting in Boston, MA, August 19-23. The Symposium was sponsored by the Physical Chemistry Division, ACS. The technical program for the meeting is available at http://phys-acs.org/fall2007.html.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human Host Cellular Response to HCoV-229E Infection Proteomics (ACS-JM-DP2)

The purpose of this experiment was to evaluate the human host cellular response to wild-type Human coronavirus strain 229E (HCoV-229E) infection. Sample data was obtained for mock and infected immortalized human lung epithelial cells (A549) (MOI 5) nuclear extracts, immortalized human lung fibroblasts cells (MRC5) (MOI5) nuclear extracts, and primary human airway epithelial (HAE) (MOI 3) cells from lung tissue and processed for proteome analysis. Processed datasets are openly accessible from the download button and contain secondary processed proteomic results files and supporting metadata materials. Experimental proteomics samples were prepared using Limited Proteolysis (LiP) methods for Label-free quantification (LFQ) and global proteomic evaluation. Sample data was acquired using a Q-Exactive HF-X mass spectrometer and was processed and compiled using MaxQuant software (v.1.6.17.0). Processed proteomic data downloads include a sample naming key, processed MaxQuant results/parameters, and protein annotated relative abundance files. See corresponding primary data accessions below and Viral Experiment LiP Analysis source code supporting data transparency and reuse. Experimental transcriptomics samples were collected in parallel and processed for RNA sequencing (RNA-Seq) as summarized under ACS-DP1 (https://data.pnnl.gov/group/nodes/dataset/34069).

59 BASIC BIOLOGICAL SCIENCES↗

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

PowerModel-AI: A First On-the-Fly Machine-Learning Predictor for AC Power Flow Solutions

The real-time creation of machine-learning models via active or on-the-fly learning has attracted considerable interest across various scientific and engineering disciplines. These algorithms enable machines to build models autonomously while remaining operational. Through a series of query strategies, the machine can evaluate whether newly encountered data fall outside the scope of the existing training set. In this study, we introduce PowerModel-AI, an end-to-end machine learning software designed to accurately predict AC power flow solutions. We present detailed justifications for our model design choices and demonstrate that selecting the right input features effectively captures load flow decoupling inherent in power flow equations. Our approach incorporates on-the-fly learning, where power flow calculations are initiated only when the machine detects a need to improve the dataset in regions where the model’s suboptimal performance is based on specific criteria. Otherwise, the existing model is used for power flow predictions. This study includes analyses of five Texas A&M synthetic power grid cases, encompassing the 14-, 30-, 37-, 200-, and 500-bus systems. The training and test datasets were generated using PowerModels.jl, an open-source power flow solver/optimizer developed at Los Alamos National Laboratory, NM, USA.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Response of AC-coupled Low Gain Avalanche Detectors to Ionizing and Non-ionizing Radiation Damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

FOS: Physical sciences↗