Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Low-cost tape system measures velocity of acceleration

By affixing perforated magnetic recording tape to the falling end of a body, acceleration and velocity were measured. The measurement was made by allowing the tape to pass between a light source and a photoelectric sensor. Data was obtained from a readout device.

Hartenstein, R.↗

Exploring the Acceleration Mechanisms for Particle Injection and Power-law Formation during Transrelativistic Magnetic Reconnection

Magnetic reconnection in the relativistic and transrelativistic regimes is able to accelerate particles to hard power-law energy spectra f ∝ γ -p (approaching p = 1). The underlying acceleration mechanism that determines the spectral shape is currently a topic of intense investigation. By means of fully kinetic plasma simulations, we carry out a study of particle acceleration during magnetic reconnection in the transrelativistic regime of a proton–electron plasma. While earlier work in this parameter regime has focused on the effects of electric field parallel to the local magnetic field on the particle injection (from thermal energy to the lower-energy bound of the power-law spectrum), here we examine the roles of both parallel and perpendicular electric fields to gain a more complete understanding on the injection process and further development of a power-law spectrum. We show that the parallel electric field does contribute significantly to particle injection, and is more important in the initial phase of magnetic reconnection. However, as the simulation proceeds, the acceleration by the perpendicular electric field becomes more important for particle injection and completely dominates the acceleration responsible for the high-energy power-law spectrum. This holds robustly, in particular for longer reconnection times and larger systems, i.e., in simulations that are more indicative of the processes in astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

Patterns of Care, Tolerability, and Safety of the First Cohort of Patients Treated on a Novel High-Field MR-Linac Within the MOMENTUM Study: Initial Results From a Prospective Multi-Institutional Registry

High-field magnetic resonance-linear accelerators (MR-Linacs), linear accelerators combined with a diagnostic magnetic resonance imaging (MRI) scanner and online adaptive workflow, potentially give rise to novel online anatomic and response adaptive radiation therapy paradigms. The first high-field (1.5T) MR-Linac received regulatory approval in late 2018, and little is known about clinical use, patient tolerability of daily high-field MRI, and toxicity of treatments. Herein we report the initial experience within the MOMENTUM Study (NCT04075305), a prospective international registry of the MR-Linac Consortium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Channeling acceleration in crystals and nanostructures and studies of solid plasmas: new opportunities

In this study, plasma wakefield acceleration (PWFA) has shown illustrious progress and resulted in an impressive demonstration of tens of GeV particle acceleration in meter-long single structures. To reach even higher energies in the 1 TeV to 10 TeV range, a promising scheme is channeling acceleration in solid-density plasmas within crystals or nanostructures. The E336 experiment studies the beam-nanotarget interaction with the highly compressed electron bunches available at the FACET-II accelerator. These studies furthermore involve an in-depth research on dynamics of beam-plasma instabilities in ultra-dense plasma, its development and suppression in structured media like carbon nanotubes and crystals, and its potential use to transversely modulate the electron bunch.

43 PARTICLE ACCELERATORS↗

Effect of magnetic field inclination on black hole jet power and particle acceleration

Rotating black holes are known to launch relativistic jets and accelerate particles if they accrete a magnetized plasma. It remains unclear, however, how the global magnetic field orientation affects the jet powering efficiency. We propose the first kinetic study of a collisionless plasma around a Kerr black hole embedded in a magnetic field that is inclined with respect to the black hole spin axis. Using three-dimensional general relativistic particle-in-cell simulations, we show that while oblique magnetic field configurations significantly reduce the jet power, particle acceleration still remains highly efficient. This suggests that black holes producing a weak jet might still be bright sources of nonthermal radiation and cosmic rays.

acceleration of particles↗

Model for Generation of Neutrons in a Compact Diode with Laser-Plasma Anode and Suppression of Electron Conduction Using a Permanent Cylindrical Magnet

A model for acceleration of deuterons and generation of neutrons in a compact laser-plasma diode with electron isolation using magnetic field generated by a hollow cylindrical permanent magnet is presented. Experimental and computer-simulated neutron yields are compared for the diode structure under study. An accelerating neutron tube with a relatively high neutron generation efficiency can be constructed using suppression of electron conduction with the aid of a magnet placed in the vacuum volume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tunable Permanent Magnet Quadrupole Operating at Cryogenic Temperatures for Accelerators

The project objective is to develop a compact and tunable quadrupole using Electron Energy Corporation (EEC)’s PM materials for cryogenic accelerator applications. To achieve this objective, EEC and SLAC National Accelerator Laboratory (SLAC) will collaborate to develop a cost-effective quadrupole and optimize the conventional manufacturing process. Based on previous experience, EEC designed an innovative field adjustment capability using tuning magnets which is able to achieve all the requirements for SLAC’s cold copper collider (C3 ) application. These novel ideas enable us to develop a compact and tunable quadrupole magnet superior to the current designs. Our approach is to leverage EEC's over 50 years of experience in magnet manufacturing and SLAC’s beamline test capabilities.

42 ENGINEERING↗

Variation in Ion Acceleration Characteristics of the HERMeS Hall Thruster During Magnetic Optimization

To reduce design risks for future magnetically shielded Hall thrusters, a test was performed on the HERMeS to obtain data for optimizing the effect of magnetic shielding. As a part of this test, laser-induced fluorescence velocimetry was used to characterize the variations in the ion acceleration with different magnetic configurations. Four magnetic configurations representing varying amounts of magnetic shielding between the high-energy discharge plasma and the discharge channel walls were tested. The ion velocity data points to the possibility that different plasma-wall interaction physics applies to a magnetically shielded thruster than a non-shielded thruster. The transition point is very prominent and can potentially be used to test whether a thruster is fully magnetically shielded.

Hall thrusters↗

Variation in Ion Acceleration Characteristics of the HERMeS Hall Thruster During Magnetic Optimization

To reduce design risks for future magnetically shielded Hall thrusters, a test was performed on the HERMeS to obtain data for optimizing the effect of magnetic shielding. As a part of this test, laser-induced fluorescence velocimetry was used to characterize the variations in the ion acceleration with different magnetic configurations. Four magnetic configurations representing varying amounts of magnetic shielding between the high-energy discharge plasma and the discharge channel walls were tested. The ion velocity data points to the possibility that different plasma-wall interaction physics applies to a magnetically shielded thruster than a non-shielded thruster. The transition point is very prominent and can potentially be used to test whether a thruster is fully magnetically shielded.

HERMeS↗

The acceleration of ions and electrons by electromagnetic ion cyclotron waves

Test particle calculations of the interaction of electrons and ions with obliquely propagating electromagnetic ion cyclotron waves are presented. Such waves have frequencies below the ion cyclotron frequency. The test particle calculations show that field-aligned electrons can be accelerated parallel to the magnetic field by such waves and that ions can be accelerated perpendicular to the magnetic field to form ion conics. Ions can be accelerated much more effectively when the wave frequency is half the ion gyrofrequency. The results are applicable to acceleration of ions and electrons in the low-Beta plasma of the auroral zone.

Temerin, M.↗

Modeling Electron Acceleration and Transport in the Early Impulsive Phase of the 2017 September 10th Solar Flare

The X8.2-class limb flare on 2017 September 10 is among the best studied solar flare events owing to its great similarity to the standard flare model and the broad coverage by multiple spacecraft and ground-based observations. These multiwavelength observations indicate that electron acceleration and transport are efficient in the reconnection and flare looptop regions. However, there lacks a comprehensive model for explaining and interpreting the multi-faceted observations. In this work, we model the electron acceleration and transport in the early impulsive phase of this flare. We solve the Parker transport equation that includes the primary acceleration mechanism during magnetic reconnection in the large-scale flare region modeled by MHD simulations. We find that electrons are accelerated up to several MeV and fill a large volume of the reconnection region, similar to the observations shown in microwaves. The electron spatial distribution and spectral shape in the looptop region agree well with those derived from the microwave and hard X-ray emissions before magnetic islands grow large and dominate the acceleration. Future emission modelings using the electron maps will enable direct comparison with microwave and hard X-ray observations. These results shed new light on the electron acceleration and transport in a broad region of solar flares within a data-constrained realistic flare geometry.

79 ASTRONOMY AND ASTROPHYSICS↗

On the properties of synchrotron-like X-ray emission from laser wakefield accelerated electron beams

The electric and magnetic fields responsible for electron acceleration in a Laser Wakefield Accelerator (LWFA) also cause electrons to radiate x-ray photons. Such x-ray pulses have several desirable properties including short duration and being well collimated with tunable high energy. We measure the scaling of this x-ray source experimentally up to laser powers greater than 100 TW. An increase in laser power allows electron trapping at a lower density as well as with an increased trapped charge. These effects ended in an x-ray fluence that was measured to increase non-linearly with laser power. The fluence of x-rays was also compared with that produced from K-α emission resulting from a solid target interaction for the same energy laser pulse. The flux was demonstrated to be comparable, but the LWFA x-rays had a significantly smaller source size. This indicates that such a source may be useful as a backlighter for probing high energy density plasmas with ultrafast temporal resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of the Room Temperature Field Quality Measurements of HL-LHC MQXFA Magnet Assemblies

As a member of the multi-lab U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), Lawrence Berkeley National Laboratory (LBNL) is assembling high-field Nb3Sn low-beta MQXFA quadrupole magnets for eventual installation at CERN as part of the HL-LHC upgrade. Each magnet undergoes room temperature magnetic measurements at two points during the assembly process: once after completion of the coil pack sub-assembly and once after the magnet is fully assembled and pre-loaded. Beyond its use to verify that each magnet assembly can meet operational requirements, the data from this two-stage measurement process allow for investigation into the impact of the pre-loading operation on field quality. Recent measurements on magnet rebuilds as well as exploratory coil pack reconfigurations also provide an opportunity to see in isolation the effects of changes to a magnet’s coil selection or coil layout. In this work, we present the magnetic measurement results of MQXFA magnets assembled or currently in process, focusing particularly on magnets with data corresponding to multiple builds, and discuss trends and insights which may be beneficial for the remaining MQXFA magnet production or for future Nb3Sn accelerator magnets.

Doyle, Jennifer [LBNL, Berkeley] (ORCID:0009000079↗

Neutron spectra from beam-target reactions in dense Z-pinches

The energy spectrum of neutrons emitted by a range of deuterium and deuterium-tritium Z-pinch devices is investigated computationally using a hybrid kinetic-MHD model. 3D MHD simulations are used to model the implosion, stagnation, and break-up of dense plasma focus devices at currents of 70 kA, 500 kA, and 2 MA and also a 15 MA gas puff. Instabilities in the MHD simulations generate large electric and magnetic fields, which accelerate ions during the stagnation and break-up phases. A kinetic model is used to calculate the trajectories of these ions and the neutron spectra produced due to the interaction of these ions with the background plasma. It is found that these beam-target neutron spectra are sensitive to the electric and magnetic fields at stagnation resulting in significant differences in the spectra emitted by each device. Most notably, magnetization of the accelerated ions causes the beam-target spectra to be isotropic for the gas puff simulations. It is also shown that beam-target spectra can have a peak intensity located at a lower energy than the peak intensity of a thermonuclear spectrum. A number of other differences in the shapes of beam-target and thermonuclear spectra are also observed for each device. Finally, significant differences between the shapes of beam-target DD and DT neutron spectra, due to differences in the reaction cross-sections, are illustrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators

Purpose: The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. Methods: An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7–20 MeV) of an Elekta Infinity radiotherapy accelerator. Results: Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower energies. Energy calibration plots of peak mean energy versus peak mean position of the net mean dose profiles for each of the seven electron beams followed the shape predicted by the Lorentz force law for a uniform z-component of the magnetic field, validating its being modeled as uniform (0.542 ± 0.027 T). Measured Elekta energy spectra and their peak mean energies correlated with the 0.5-cm (7–13 MeV) and the 1.0-cm (13–20 MeV) R{sub 90} spacings of the %DD curves. The full-width-half-maximum of the energy spectra decreased with decreasing peak mean energy with the exception of the 9-MeV beam, which was anomalously wide. Similarly, R{sub 80–20} decreased linearly with peak mean energy with the exception of the 9 MeV beam. Both were attributed to suboptimal tuning of the high power phase shifter for the recycled radiofrequency power reentering the traveling wave accelerator. Conclusions: The apparatus and analysis techniques of the authors demonstrated that an inexpensive, lightweight, permanent magnet electron energy spectrometer can be used for measuring the electron energy distributions of therapeutic electron beams (6–20 MeV). The primary goal of future work is to develop a real-time spectrometer by incorporating a real-time imager, which has potential applications such as beam matching, ongoing beam tune maintenance, and measuring spectra for input into Monte Carlo beam calculations.

60 APPLIED LIFE SCIENCES↗

Measurement of accreted helium ion velocity using Doppler spectroscopy in the CTIX compact-toroid plasma accelerator

A compact-toroid (CT) accelerator is a device for the production of plasma bodies which contain a relatively strong internal magnetic field, which permits the plasma body to withstand large forces of acceleration while retaining its magnetic field structure. Typically, the CT occupies an annular region between inner and outer radii, defined by coaxial inner and outer electrodes, across which a large electric potential is applied. The internal magnetic fields of the CT contain both a toroidal and poloidal component, as shown in Fig. 1(a). These fields are typically of comparable magnitude. Because of the effective rigidity provided by internal magnetic fields, the CT can be accelerated to high velocities in short distances. Since internal fields increase in proportion to accelerating magnetic field, there is no strength at which the accelerating magnetic fields overcome the internal field (blow-by). Because of this, the kinetic energy density of CTs can be made to exceed the energy density of magnetic fields typical of plasma containment devices such as tokamaks. CTs have the potential to be launched into the interior of such devices for either delivering fuel (typically deuterium or hydrogen), or to deliver particles of high atomic number (high-Z). An important application of high-Z CT injection into tokamaks is to aid in plasma quenching by radiation, to mitigate the effects of plasma disruptions and prevent damage to the plasma confinement device. In addition, high-Z CTs may be used as sources of kinetic energy density for plasma-compression experiments. In this case, the use of plasma species of high atomic number is also desirable, since kinetic energy density is proportional to atomic number for given CT velocity and electron density gas puffing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗