Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Two-dimensional electromagnetic Child-Langmuir law of a short-pulse electron flow

Two-dimensional electromagnetic particle-in-cell simulations were performed to study the effect of the displacement current and the self-magnetic field on the space charge limited current density or the Child-Langmuir law of a short-pulse electron flow with a propagation distance of {zeta} and an emitting width of W from the classical regime to the relativistic regime. Numerical scaling of the two-dimensional electromagnetic Child-Langmuir law was constructed and it scales with ({zeta}/W) and ({zeta}/W){sup 2} at the classical and relativistic regimes, respectively. Our findings reveal that the displacement current can considerably enhance the space charge limited current density as compared to the well-known two-dimensional electrostatic Child-Langmuir law even at the classical regime.

43 PARTICLE ACCELERATORS↗

A Mott polarimeter operating at MeV electron beam energies

We have developed a Mott electron polarimeter for the Mainzer microtron (MAMI) accelerator in Mainz, Germany. At beam energies ranging between 1.0 and 3.5 MeV two double focusing magnet spectrometers collect elastically backscattered electrons from gold targets. In spite of the small spectrometer acceptance, a sufficient statistical efficiency is achieved to provide very fast measurements if beam currents typical for experiments at MAMI are being used. High reproducibility is achieved, demonstrating that the results of asymmetry measurements are independent of the primary beam current in a range from 0.004 to 45 {mu}A at a level of <1% relative variation. Compared to low energy polarimeters of similar construction an improvement of a factor 2-3 in absolute accuracy seems possible.

43 PARTICLE ACCELERATORS↗

Low power high-performance radio frequency oscillator for driving ion traps

We report a simple, efficient, high voltage radio frequency (RF) generator powered by a single voltage source (1.5-7 V) to resonantly drive ion traps or other capacitive loads. Our circuit is able to deliver RF voltages > 500 V{sub p-p} at frequencies ranging from 0.1 to 10 MHz. This RF oscillator uses low-cost, commercially available components, and can be easily assembled onto a circuit board of a few cm{sup 2}. Because of its simplicity and good efficiency, this circuit is useful in applications requiring small size and low power consumption such as portable ion trap systems where the duration of operation under battery power is of concern.

43 PARTICLE ACCELERATORS↗

Relativistic Bursian diode equilibria

A comprehensive study of steady-states of a planar vacuum diode driven by a cold relativistic electron beam is presented. The emitter electric field as a characteristic function for their existence is evaluated in dependence of the diode length, the applied potential V, and the relativistic beam factor at injection {gamma}{sub 0}. It is used to classify the different branches of possible solutions, which encompass electron flows that are (i) transmitted through the diode completely, (ii) partially reflected from a virtual cathode (VC) either within the diode region or at the collector side, and (iii) reflected totally. As a byproduct, the V and {gamma}{sub 0} dependences of both bifurcation points of the minimum potential and of the transmitted current are obtained and the ultrarelativistic limit, {gamma}{sub 0}>>1, is performed. In this highly relativistic regime, the density of electrons appears to be constant across the diode region except for a small area around the VC.

43 PARTICLE ACCELERATORS↗

Virtual boundary element method for multistage depressed collector of traveling-wave tubes

In this study, virtual boundary element (VBE) method has been employed in multistage depressed collector (MDC) simulation for high efficiency traveling-wave tubes (TWTs). The basic idea of this method is establishing a mapping relation between the source on the real and virtual boundaries. When calculating the potential of the problem field, the virtual source on virtual boundary is only used, instead of the source on real boundary. We discussed the distance between the virtual and real boundaries and the discrete density of virtual boundary, which are closely related to the calculation accuracy. Based on the VBE method, a new computer aided design code CCAD is developed for the MDC system of high efficiency TWT. The results of simulations performed on an axisymmetric four-stage depressed collector are reported. The advantages of VBE method mainly lie in fast calculation and accurate solution. This is of benefit to designing high efficiency MDC thus developing high efficiency TWT, especially for space TWT.

43 PARTICLE ACCELERATORS↗

Epid Dosimetry

Electronic portal imaging devices (EPIDs) were introduced originally for patient position verification. The idea of using EPIDs for dosimetry was realised in the 1980s. Little was published on the topic until the mid 1990's, when the interest in EPIDs for dosimetry increased rapidly and continues to grow. The increasing research on EPID dosimetry coincided with the introduction of intensity modulated radiation therapy (IMRT). EPIDs are well suited to IMRT dosimetry because they are high resolution, two-dimensional (2D) digital detectors. They are also pre-existing on almost all modern linear accelerators. They generally show a linear response to increasing dose. Different types of EPIDs have been clinically implemented, and these have been described in several review papers. The current generation of commercially available EPIDs are indirect detection active matrix flat panel imagers, also known as amorphous silicon (a-Si) EPIDs. Disadvantages of a-Si EPIDs for dosimetry include non-water equivalent construction materials, and the energy sensitivity and optical scatter of the phosphor scintillators used to create optical signal from the megavoltage beam. This report discusses current knowledge regarding a-Si EPIDs for dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multipurpose modular experimental station for the DiProI beamline of Fermi-Elettra free electron laser

We present a compact modular apparatus with a flexible design that will be operated at the DiProI beamline of the Fermi-Elettra free electron laser (FEL) for performing static and time-resolved coherent diffraction imaging experiments, taking advantage of the full coherence and variable polarization of the short seeded FEL pulses. The apparatus has been assembled and the potential of the experimental setup is demonstrated by commissioning tests with coherent synchrotron radiation. This multipurpose experimental station will be open to general users after installation at the Fermi-Elettra free electron laser in 2011.

43 PARTICLE ACCELERATORS↗

Actinide Neutron-Induced Fission Cross Section Measurements At LANSCE

Fission cross sections of a range of actinides have been measured at the Los Alamos Neutron Science Center (LANSCE) in support of nuclear energy applications in a wide energy range from sub thermal energies up to 200 MeV. Parallel-plate ionization chambers are used to measure fission cross sections ratios relative to the {sup 235}U standard while incident neutron energies are determined using the time-of-flight method. Recent measurements include the {sup 233,238}U, {sup 239-242}Pu and {sup 243}Am neutron-induced fission cross sections. Obtained data are presented in comparison with existing evaluations and previous data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of a symmetrical Cockcroft-Walton power supply of 50 Hz 1.2 MV/50 mA

A 1.2 MV/50 mA symmetrical Cockcroft-Walton (SCW) power supply of over 83% power efficiency, driven by 50 Hz frequency, was developed for an industrial electron beam irradiator. It is constructed by capacitors of 45 nF and 28.13 nF in the coupling column and capacitors of 18.75 nF in the smoothing column. Working status of the rectifier in high power output condition was analyzed, and the conduction angle of the rectifier was calculated. The power factor (PF) of the SCW circuit has been studied, and the equivalent condensance of the circuit has been derived. Measurements were done for the PF compensation. The surge impact during the short circuit transient process was considered in choosing the protection resistance. Test results showed that design specifications of the power supply were achieved, with the non-load voltage being up to 1.32 MV and the ratio of ripple voltage to output voltage as 9.4%.

43 PARTICLE ACCELERATORS↗

On the implementation of computed laminography using synchrotron radiation

Hard x rays from a synchrotron source are used in this implementation of computed laminography for three-dimensional (3D) imaging of flat, laterally extended objects. Due to outstanding properties of synchrotron light, high spatial resolution down to the micrometer scale can be attained, even for specimens having lateral dimensions of several decimeters. Operating either with a monochromatic or with a white synchrotron beam, the method can be optimized to attain high sensitivity or considerable inspection throughput in synchrotron user and small-batch industrial experiments. The article describes the details of experimental setups, alignment procedures, and the underlying reconstruction principles. Imaging of interconnections in flip-chip and wire-bonded devices illustrates the peculiarities of the method compared to its alternatives and demonstrates the wide application potential for the 3D inspection and quality assessment in microsystem technology.

43 PARTICLE ACCELERATORS↗

Five-element Johann-type x-ray emission spectrometer with a single-photon-counting pixel detector

A Johann-type spectrometer with five spherically bent crystals and a pixel detector was constructed for a range of hard x-ray photon-in photon-out synchrotron techniques, covering a Bragg-angle range of 60 deg. - 88 deg. The spectrometer provides a sub emission line width energy resolution from sub-eV to a few eV and precise energy calibration, better than 1.5 eV for the full range of Bragg angles. The use of a pixel detector allows fast and easy optimization of the signal-to-background ratio. A concentration detection limit below 0.4 wt% was reached at the Cu K{alpha}{sub 1} line. The spectrometer is designed as a modular mobile device for easy integration in a multi-purpose hard x-ray synchrotron beamline, such as the SuperXAS beamline at the Swiss Light Source.

43 PARTICLE ACCELERATORS↗

The double electrostatic ion ring experiment: A unique cryogenic electrostatic storage ring for merged ion-beams studies

We describe the design of a novel type of storage device currently under construction at Stockholm University, Sweden, using purely electrostatic focussing and deflection elements, in which ion beams of opposite charges are confined under extreme high vacuum cryogenic conditions in separate ''rings'' and merged over a common straight section. The construction of this double electrostatic ion ring experiment uniquely allows for studies of interactions between cations and anions at low and well-defined internal temperatures and centre-of-mass collision energies down to about 10 K and 10 meV, respectively. Position sensitive multi-hit detector systems have been extensively tested and proven to work in cryogenic environments and these will be used to measure correlations between reaction products in, for example, electron-transfer processes. The technical advantages of using purely electrostatic ion storage devices over magnetic ones are many, but the most relevant are: electrostatic elements which are more compact and easier to construct; remanent fields, hysteresis, and eddy-currents, which are of concern in magnetic devices, are no longer relevant; and electrical fields required to control the orbit of the ions are not only much easier to create and control than the corresponding magnetic fields, they also set no upper mass limit on the ions that can be stored. These technical differences are a boon to new areas of fundamental experimental research, not only in atomic and molecular physics but also in the boundaries of these fields with chemistry and biology. For examples, studies of interactions with internally cold molecular ions will be particular useful for applications in astrophysics, while studies of solvated ionic clusters will be of relevance to aeronomy and biology.

43 PARTICLE ACCELERATORS↗

Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 {Omega} characteristic impedance to match with 50 {Omega} standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

43 PARTICLE ACCELERATORS↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗

A time-of-flight backscattering spectrometer at the Spallation Neutron Source, BASIS

We describe the design and current performance of the backscattering silicon spectrometer (BASIS), a time-of-flight backscattering spectrometer built at the spallation neutron source (SNS) of the Oak Ridge National Laboratory (ORNL). BASIS is the first silicon-based backscattering spectrometer installed at a spallation neutron source. In addition to high intensity, it offers a high-energy resolution of about 3.5 {mu}eV and a large and variable energy transfer range. These ensure an excellent overlap with the dynamic ranges accessible at other inelastic spectrometers at the SNS.

43 PARTICLE ACCELERATORS↗

A solid-state Marx generator driven Einzel lens chopper

A new type of pulse chopper called an Einzel lens chopper is described. An Einzel lens placed immediately after an electron cyclotron resonance ion source is driven by high-voltage pulses generated by a newly developed solid-state Marx generator. A rectangular negative barrier pulse-voltage is controlled in time, and the barrier pulse is turned on only when a beam pulse is required. The results of successful experiments are reported herein.

43 PARTICLE ACCELERATORS↗

Imaging single electrons to enable the generation of ultrashort beams for single-shot femtosecond relativistic electron diffraction

The generation and control of relativistic electron beams well suited for ultrafast electron diffraction application has rapidly advanced, greatly benefiting from the overlap in techniques and expertise with the accelerator community. However, imaging the diffracted MeV electrons with high detection efficiency has remained an under-explored area. In this paper, we report on a quantitative study of the imaging of MeV electrons using a detection system consisting of a phosphor screen, a lens-coupling optics, and a charge-coupled device camera. It is shown that every MeV electron in the beam yields a signal well above the camera noise. With this detection efficiency, only {approx}10{sup 5} electrons per pulse are needed to obtain a high quality single-shot diffraction pattern from a crystalline sample. We measured that such a low charge beam can be as short as 30 fs rms. Further, we discuss the possibility of compressing these electron beams to sub-5 fs rms bunch length by velocity bunching using a short high gradient rf accelerating structure scheduled to be installed next year at the UCLA Pegasus Laboratory. This opens the possibility of single-shot determinations of structural changes in many ultrafast physical processes like nonequilibrium phonon dynamics or relaxation pathways in systems with strong electron-phonon coupling.

43 PARTICLE ACCELERATORS↗

Extraction of the Compton Form Factor H from DVCS Measurements in the Quark Sector

Working at twist 2 accuracy and assuming the dominance of the Generalized Parton Distribution H we study the helicity-dependent and independent cross sections measured in Hall A, the beam spin asymmetries measured in Hall B at Jefferson Laboratory and beam charge, beam spin and target spin asymmetries measured by Hermes. We extract the real and imaginary parts of the Compton Form Factor H, the latter being obtained with a 20-50 % uncertainty. We pay extra attention to the estimation of systematic errors on the extraction of H. We discuss our results and compare to other extractions as well as to the popular VGG model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗