Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Monitoring and Control of the Hybrid Laser-Gas Metal-Arc Welding Process

Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

36 MATERIALS SCIENCE↗

Key Learnings from Hydraulic Fracturing Test Site - 2 (HFTS-2), Delaware Basin

Hydraulic fractures (HF) play a dominant role in oil and gas production from unconventional reservoirs, fracture characteristics, geometry, and extent are generally not well known and are typically inferred from various monitoring methods or subsurface models. The Hydraulic Fracturing Test Site-2 (HFTS-2) is a field-based research experiment performed in the Wolfcamp formation of the Permian (Delaware) Basin. HFTS-2, a unique joint industry program (JIP) that brings together government, academia, and industry, focused on field data acquisition and interpretation. The project has built a comprehensive HF research dataset that includes microseismic (MS), 1,500 ft of core, diagnostic formation injection tests (DFIT), fluid characterization, advanced logs, geochemistry, downhole gauges, varying completions, and permanent fiber optic (FO) cable in vertical and horizontal wells. These data were integrated and used to characterize HF geometry/dimensions and resulting depletion profiles, gain insights for completion design, and achieve a better understanding of parent well depletion effects on child well performance. The analysis and integration of the comprehensive HFTS-2 diagnostics dataset provide insights for optimal well placement and completions and improves understanding about the effects of parent well depletion. Furthermore, this dataset can be used to blind test and develop subsurface workflows for unconventional resources. Key learnings from HFTS-2 and the new technologies tested can easily be transferred to other unconventional plays.

58 GEOSCIENCES↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Synthesis of SHAL and SHAL Precursor Standard, CRADA No. TC02174.0

The purpose of this CRADA was to establish a collaborative effort between SHAL Technologies and Lawrence Livermore National Laboratory that would advance the development and testing of a family of small molecule oncology drugs and companion diagnostics called selective high affinity ligands (SHALs) for the treatment of advanced non-Hodgkin’s lymphoma. These compounds were first synthesized by the LLNL chemist participating in this CRADA when the compounds were first developed (2004-2008) by the founders of SHAL Technologies (while they were employed at LLNL). This CRADA initially had five deliverables. Deliverables 1-3 involved LLNL’s synthesis of 10-50 mg of the SHALs SH7133 and SH7139 using the same bench-scale conditions used previously, their purification, and obtaining data needed to demonstrate the mass and purity of the compounds. Deliverable 4, which was to be completed by SHAL Technologies, was the comparison of the bench-scale synthetic products to the same compounds manufactured on the multigram to kilogram scale by the contract research organization (CRO) AmbioPharm Inc. The fifth deliverable was this final report. An amendment was made to add the additional tasks and deliverables needed to synthesize the third SHAL standard SH7129 (the diagnostic) and compare it to product manufactured by AmbioPharm. During the testing of the three standards synthesized by LLNL, the SHAL compounds were found to lack biological activity. When we discovered that a commercial chemical supplier provided both LLNL and our CRO AmbioPharm with a SHAL precursor that had the wrong structure, two amendments to the CRADA were made to add additional tasks and deliverables to enable us to repeat all the syntheses and conduct more extensive testing of the bench scale and manufactured products. Once the final correct products were synthesized and confirmed to have the right structures, a third amendment was added to the CRADA to enable the synthesis of two fragments of the SHALs to determine if these compounds are produced when the SHALs are metabolized. This last synthesis was included to provide the information needed to establish a second, new CRADA between SHAL Technologies and LLNL that would focus on the identifying how the SHALs are metabolized and how their metabolic products may be responsible for the selective killing of tumor cells over-expressing the protein targeted by the SHALs, HLA-DR10.

60 APPLIED LIFE SCIENCES↗

The NASA CSTI high capacity power project

The SP-100 Space Nuclear Power Program was established in 1983 by DOD, DOE, and NASA as a joint program to develop technology for military and civil applications. Starting in 1986, NASA has funded a technology program to maintain the momentum of promising aerospace technology advancement started during Phase 1 of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for a wide range of future space applications. The elements of the Civilian Space Technology Initiative (CSTI) High Capacity Power Project include Systems Analysis, Stirling Power Conversion, Thermoelectric Power Conversion, Thermal Management, Power Management, Systems Diagnostics, Environmental Interactions, and Material/Structural Development. Technology advancement in all elements is required to provide the growth capability, high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall project will develop and demonstrate the technology base required to provide a wide range of modular power systems compatible with the SP-100 reactor which facilitates operation during lunar and planetary day/night cycles as well as allowing spacecraft operation at any attitude or distance from the sun. Significant accomplishments in all of the project elements will be presented, along with revised goals and project timelines recently developed.

Winter, J.↗

ADVANCES IN DUST DETECTION AND REMOVAL FOR TOKAMAKS

Dust diagnostics and removal techniques are vital for the safe operation of next step fusion devices such as ITER. In the tokamak environment, large particles or fi bers can fall on the electrostatic detector potentially causing a permanent short. An electrostatic dust detector developed in the laboratory is being applied to the National Spherical Torus Experiment (NSTX). We report on the development of a gas puff system that uses helium to clear such particles from the detector. Experiments at atmospheric pressure with varying nozzle designs, backing pressures, puff durations and exit fl ow orientations have given an optimal confi guration that effectively removes particles from a 25 cm² area. Similar removal effi ciencies were observed under a vacuum base pressure of 1 mTorr. Dust removal from next step tokamaks will be required to meet regulatory dust limits. A tri-polar grid of fi ne interdigitated traces has been designed that generates an electrostatic traveling wave for conveying dust particles to a “drain.” First trials with only two working electrodes have shown particle motion in optical microscope images.

Campos, A↗

AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF

Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medical care capabilities for Space Station Freedom: A phase approach

As a result of Congressional mandate Space Station Freedom (SSF) was restructured. This restructuring activity has affected the capabilities for providing medical care on board the station. This presentation addresses the health care facility to be built and used on the orbiting space station. This unit, named the Health Maintenance Facility (HMF) is based on and modeled after remote, terrestrial medical facilities. It will provide a phased approach to health care for the crews of SSF. Beginning with a stabilization and transport phase, HMF will expand to provide the most advanced state of the art therapeutic and diagnostic capabilities. This presentation details the capabilities of such a phased HMF. As Freedom takes form over the next decade there will be ever-increasing engineering and scientific developmental activities. The HMF will evolve with this process until it eventually reaches a mature, complete stand-alone health care facility that provides a foundation to support interplanetary travel. As man's experience in space continues to grow so will the ability to provide advanced health care for Earth-orbital and exploratory missions as well.

Doarn, C. R.↗

Characterization of a linear device developed for research on advanced plasma imaging and dynamics

Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 deg. C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5x10{sup -8} Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer model for estimating electrochemical cell kinetic performance

The effective rates or "kinetics" of electrochemical reactions at electrode surfaces is an abiding area of interest for diagnostic analysis of new materials in energy storage devices such as lithium-ion cells. It is generally understood that kinetic limitations can dominate performance during power pulses and stem from interfacial impedance sources. Yet, kinetic limitations are poorly understood in contemporary electrochemical energy storage devices, and antiquated modeling techniques are often incorrectly applied to lithium-ion cell systems, for example, the classical Butler-Volmer (BV) expression. The referenced invention provides an advanced modeling technique of exceptional accuracy that allows diagnostic analysis of kinetic parameters over current, temperature, device aging, and pulse time domains. This invention represents an advanced approach that accounts for the effects of surface availability and thermodynamic constraints on kinetic rates, based on common cell data (e.g., direct-current (DC) pulse analysis under constant-current conditions). The model yields highly accurate predictions of voltage drop for a given device at arbitrary conditions. This capability satisfies a clear need for knowledge regarding mechanistic constraints of electrochemical energy storage devices under arbitrary conditions, and can be integrated into diagnostic software embedded into device applications. The methodology allows diagnostic analysis to be performed, providing key quantities central to understanding kinetic limitations in electrochemical devices, such as the (1) exchange current density, (2) the effective electrode surface availability, (3) the thermodynamic interfacial energy barrier, (4) as well as various overpotential and impedance terms dealing with the intrinsic charge transfer, mass-transport limitations, ohmic contributions, and total impedance, all given as a function of temperature, pulse time, and cell aging. The present form of CellSage-Kinetics is programmable FORTRAN code, a form that supports theoretical/mathematical development activities and single-user applications. A GUI-based software version could be released if requested under a license agreement.

Gering, KevinL.↗

Containment Chamber Systems Engineering Project

Lawrence Livermore National Laboratory (LLNL) is a leading research laboratory in material properties. The most notable facility at LLNL capable of determining equation of state data for hazardous materials is the National Ignition Facility (NIF). NIF is the most energetic laser in the world and is a very versatile system that allows for a variety of laser configurations and diagnostics. The flexibility that NIF offers makes it an attractive tool for high budget programs researching specific areas of interest. Some programs require many tests to be performed, and although NIF could be an option for performing these tests, the cost and time to perform the tests would not be feasible. Also, many of these tests would underutilize the full capacity of NIF’s lasers, and NIF does not have a dedicated light source suitable for the diagnostic requirement. The needs of these tests do not align with NIF’s capabilities. The physicists are the main stakeholders for the tests, and they require a third-generation light source to meet the desired diagnostic performance. The Dynamic Compression Sector (DCS) within the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is the facility that will meet necessary laser performance and the X-ray diagnostic performance in order to obtain the desired data. DCS does not have the capability to test hazardous material, and therefore DCS requires a method and hardware for ensuring that no hazardous material is exposed before, during, or after the test. After taking a system engineering evaluation of the need for a solution to perform laser shock experiments on hazardous materials with certain laser and X-ray characteristics, a solution is proposed that meets the requirements of each involved stakeholder. The proposed solution is to contain the targets within sealed vacuum chamber that will meet the protection requirements of each facility. The chamber would be assembled and pumped down at LLNL in facilities that can handle hazardous material. Then, the chamber would be shipped under vacuum to DCS, where the chamber will be inserted into the beam paths. DCS’s laser will enter the sealed chamber and impart a shock into the target of hazardous material while the X-ray will simultaneously image the material. Once each target has been fired, the chamber will be removed from the beam path and shipped to the proper disposal facility.

42 ENGINEERING↗

Accelerating the rate of discovery: toward high-repetition-rate HED science

As high-intensity short-pulse lasers that can operate at high-repetition-rate (HRR) (>10 H z ) come online around the world, the high energy density (HED) science they enable will experience a radical paradigm shift. The >10 3 increase in shot rate over today's shot-per-hour drivers translates into dramatically faster data acquisition, more experiments, and the ability to exploit machine learning, and thus the potential to significantly accelerate the advancement of HED science. A wide range of HED experiments, from opacity investigations to secondary source generation to plasma nuclear physics, will benefit from the increased statistics, precision, and exploration of phase space. Besides increasing the rate at which scientific experiments can be performed, HRR also allows for the rapid delivery of optimal experiments supported by simulations and modeling augmented by close coupling to empirical data. To fully realize such an HRR framework, numerous subsystems must be developed and brought together, including feedback laser control loops, high-throughput targetry and diagnostics, cognitive simulation, enhanced HED codes, and advanced data analytics. This paper describes the vision for an integrated HRR laser experimental HED system and outlines some of the major considerations and challenges for realizing it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of the optical design of the ITER MSE diagnostic

The motional Stark effect (MSE) diagnostic will be essential for the study of advanced scenarios on ITER and its design is currently underway with initial emphasis on the optical design. Optical performance, as measured by photon throughput and minimization of polarization aberrations, will be critical to the success of the diagnostic. Consequently, the initial design work has been focused heavily on this area. In order meet the ITER MSE diagnostic design requirements, two approaches for the measurement are under consideration. The first is based on standard polarimeter techniques to measure the polarization of the emitted light, whereas the second measures the Stark splitting from which |B| can be inferred, where |B| is the magnitude of the total magnetic field. The base line design of the optical system is centered on the first approach. Emphasis in this case is placed on minimizing the polarization aberrations of the optical relay system. Motivation for the second method results from concern that the optical properties of the plasma-facing mirror, particularly its diattenuation and retardance, will degrade with plasma exposure. The second approach, while less sensitive to aberrations induced by plasma exposure effects, requires greater optical throughput in order to measure the complete Stark spectrum. We have developed an optimized optical design applicable to both measurement techniques. A summary of the design is presented and design issues are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic for Verifying the Thrust Vector Requirement of the AEPS Hall-Effect Thruster and Comparison to the NEXT-C Thrust Vector Diagnostic

A diagnostic has been designed and fabricated to verify the thrust vector requirement for the Advanced Electric Propulsion System (AEPS) Hall Effect Rocket with Magnetic Shielding (HERMeS) thruster. This diagnostic will be used to verify that the propulsion system thrust vector offset from the mounting surface normal vector does not exceed 1.5 degrees over the entire throttling range and over the course of 23,000 hours of thruster testing. The diagnostic will also not violate the thruster's required voltage standoff capability in the presence of carbon backsputter by being minimally intrusive and not significantly adding to the facility backsputtered rate. Based on these requirements, an appropriate diagnostic design was determined to comprise of an array of 23 Faraday probes swept through the plume in an arc 1m from the thruster to map the beam current density. The beam current density centroid of the plume is assumed to track the thrust vector within an acceptable level of uncertainty. Additionally, a reference system, including optical alignment to the mounting surface normal vector and tilt sensors, was devised to periodically calibrate the probe position and motion throughout the long duration wear test campaign. Initial measurements of the thruster plume have been acquired to demonstrate the diagnostics functionality, verify procedures, and assess any necessary improvements prior to implementation of the diagnostic during the AEPS Engineering Development Unit (EDU) long duration wear test. To illustrate the merits of differing approaches to thrust vector determination for different classes of electric propulsion thrusters, NASA's Evolutionary Xenon Thruster-Commercial (NEXT-C) thrust vector diagnostic design details and recent data are also discussed (Appendix A).

Advanced Electric Propulsion System (AEPS)↗

Performance test of the integrator system for magnetic diagnostics in KSTAR

Ten modules of the integrator system of the initial magnetic diagnostics for the first plasma operation have been simultaneously tested in the Korea superconducting tokamak advanced research device by measuring the magnetic flux density from various magnetic diagnostics sensors when a small current was applied to the superconducting poloidal field coils. The measured drifts from the integrators show between 1x10{sup -6} and 1x10{sup -5} Wb/s. The results from the field tests before the first plasma generation are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions

We present results from the grant entitled, Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions. The research significantly advanced the understanding of basic high-energy density science (HEDS) on ultra intense laser and particle beam plasma interactions. This advancement in understanding was then used to to aid in the quest to make 1 GeV to 500 GeV plasma based accelerator stages. The work blended basic research with three-dimensions fully nonlinear and fully kinetic simulations including full-scale modeling of ongoing or planned experiments. The primary tool was three-dimensional particle-in-cell simulations. The simulations provided a test bed for theoretical ideas and models as well as a method to guide experiments. The research also included careful benchmarking of codes against experiment. High-fidelity full-scale modeling provided a means to extrapolate parameters into regimes that were not accessible to current or near term experiments, thereby allowing concepts to be tested with confidence before tens to hundreds of millions of dollars were spent building facilities. The research allowed the development of a hierarchy of PIC codes and diagnostics that is one of the most advanced in the world.

43 PARTICLE ACCELERATORS↗

Optical diagnostic design for measuring the radiation front with a mid-leg pumped divertor on DIII-D

The design of an optical diagnostic system to localize the radiation front in a mid-leg pumped divertor configuration on DIII-D is presented. Divertor detachment is a key mechanism for handling power exhaust in tokamaks, and mid-leg pumping offers a promising approach to radiatively dissipate power while maintaining acceptable core performance. To predict the location of the radiation front and design a spectroscopic diagnostic to measure its position, a database of SOLPS-ITER simulations across a range of input powers and gas puffing rates representative of DIII-D operation was employed. These simulations provide self-consistent plasma backgrounds for a Cherab-Raysect synthetic diagnostic framework, which incorporates detailed tokamak geometry and physically accurate ray-tracing. Synthetic simulations of optical sightlines and viewing cone geometry were used to calculate line-integrated emission from the plasma, particularly of the C III 465 nm line, to serve as a proxy for the T e ≈ 7 − 10 eV temperature region associated with the onset and evolution of divertor detachment. Neutral deuterium emission is also evaluated for comparison. The synthetic diagnostic is used to assess the performance of existing DIII-D optical systems, including filterscopes and the Multichord Divertor Spectrometer, and to optimize line-of-sight placement within mechanical and installation constraints. The results provide quantitative guidance for diagnostic implementation on DIII-D and demonstrate the advantage of integrated synthetic diagnostics for divertor design studies and future advanced divertor concepts.

Cherab↗