Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Characterization of high energy Xe ion irradiation effects in single crystal molybdenum with depth-resolved synchrotron microbeam diffraction

Microbeam X-ray diffraction experiments were conducted at beam line 34-ID of the Advanced Photon Source (APS) on fission fragment energy Xe heavy ion irradiated single crystal Molybdenum (Mo). Lattice strain measurements were obtained with a depth resolution of 0.7 mu m, which is critical in resolving the peculiar heterogeneity of irradiation damage associated with heavy ion irradiation. Q-space diffraction peak shift measurements were correlated with lattice strain induced by the ion irradiations. Transmission electron microscopy (TEM) characterizations were performed on the as-irradiated materials as well. Nanometer sized Xe bubble microstructures were observed via TEM. Molecular Dynamics (MD) simulations were performed to help interpret the lattice strain measurement results from the experiment. This study showed that the irradiation effects by fission fragment energy Xe ion irradiations can be collaboratively understood with the depth resolved X-ray diffraction and TEM measurements under the assistance of MD simulations. (c) 2015 Elsevier B.V. All rights reserved.

Yun, Di (ORCID:0000000297673214)↗

MeV per Nucleon Ion Irradiation of Nuclear Materials with High Energy Synchrotron X-ray Characterization

The combination of MeV/Nucleon ion irradiation (e.g. 133 MeV Xe) and high energy synchrotron x-ray characterization (e.g. at the Argonne Advanced Photon Source, APS) provides a powerful characterization method to understand radiation effects and to rapidly screen materials for the nuclear reactor environment. Ions in this energy range penetrate ~10 μm into materials. Over this range, the physical interactions vary (electronic stopping, nuclear stopping and added interstitials). Spatially specific x-ray (and TEM and nanoindentation) analysis allow individual quantification of these various effects. Hard x-rays provide the penetration depth needed to analyze even nuclear fuels. Here, this combination of synchrotron x-ray and MeV/Nucleon ion irradiation is demonstrated on U-Mo fuels. A preliminary look at HT-9 steels is also presented. We suggest that a hard x-ray facility with in situ MeV/nucleon irradiation capability would substantially accelerate the rate of discovery for extreme materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystallographic texture and microstructural changes in fusion welds of recrystallized Zry-4 rolled plates

This study presents a detailed characterization of the microstructural and crystallographic texture changes observed in the transition region in a weld between two Zircaloy-4 cold rolled and recrystallized plates. The microstructural study was performed by optical microscopy under polarized light and scanning electron microscopy (SEM). Texture changes were characterized at different lengthscales: in the micrometric size, orientation imaging maps (OIM) were constructed by electron backscatter diffraction (EBSD), in the millimetre scale, high energy XRD experiments were done at the Advanced Photon Source (USA) and compared to neutron diffraction texture determinations performed in the HIPPO instrument at Los Alamos National Laboratory. In the heat affected zone (HAZ) we observed the development of Widmanstätten microstructures, typical of the α( hcp ) to β( bcc ) phase transformation. Associated with these changes a rotation of the c-poles is found in the HAZ and fusion zone. While the base material shows the typical texture of a cold rolled plate, with their c-poles pointing 35° apart from the normal direction of the plate in the normal-transversal line, in the HAZ, c-poles align along the transversal direction of the plate and then re-orient along different directions, all of these changes occurring within a lengthscale in the order of mm. The evolution of texture in this narrow region was captured by both OIM and XRD, and is consistent with previous measurements done by Neutron Diffraction in the HIPPO diffractometer at Los Alamos National Laboratory, USA. The microstructural and texture changes along the HAZ were interpreted as arising due to the effect of differences in the cooling rate and β grain size on the progress of the different α variants during transformation. Fast cooling rates and large β grains are associated to weak variant selection during the β–>α transformation, while slow cooling rates and fine β grains result in strong variant selection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microbeam synchrotron radiation diffraction and fluorescence of oxide layers formed on zirconium alloys at different corrosion temperatures

Autoclave corrosion tests of Zircaloy-4 were performed at temperatures ranging from 274°C to 427 °C to determine how the characteristics of the oxide layer changed with corrosion temperature. Corroded samples were prepared in cross-section and examined at the Advanced Photon Source using x-ray diffraction and fluorescence with sub-micron spatial resolution. These measurements provide high fidelity data for characterization of the oxide layer grown on zirconium alloys over a range of temperatures to better understand the fundamental mechanisms of corrosion. It was found that the size of the monoclinic oxide grains increases with distance from the metal-oxide interface, while the average grain size of the tetragonal oxide phase decreases. This is consistent with the continuous nucleation of a mixture of equiaxed tetragonal and monoclinic grains at the metal-oxide interface, of which only the monoclinic oxide grains that are properly aligned to minimize stresses grow into long columnar oxide grains. The tetragonal phase oxide grains transform to monoclinic oxide once a critical size is reached. While the monoclinic oxide grain size increases with corrosion temperature, the tetragonal phase grain size remains below a maximum value. Evolution of the tetragonal fraction, calculated with the Garvie-Nicholson formula, was observed, with local maxima seen just before transition and local minima seen at oxide locations corresponding to the oxide kinetic transition. No difference was observed in the tetragonal phase fraction in the oxide layers formed at different corrosion temperatures. Detailed fluorescence and diffraction mapping of one sample showed the evolution of the diffraction intensity over a short range in the oxide. In conclusion, this work provides a systematic study revealing fundamental characteristics of the microstructure of Zircaloy-4 oxide layers to further understanding of corrosion resistance of these materials.

36 MATERIALS SCIENCE↗

In situ synchrotron tensile investigations on ultrasonic additive manufactured (UAM) zirconium

The microstructure evolution during room temperature uniaxial tensile straining of ultrasonic additive manufactured (UAM) zirconium was evaluated using the Advanced Photon Source (APS) facility. Miniature dog-bone tensile specimens of two orientations were cut from a UAM-fabricated zirconium bar for in situ synchrotron tensile tests. Wide-angle X-ray scattering (WAXS) scanning was used to unveil the changes in microstructure of the entire gauge regions throughout the straining. A series of WAXS data analysis methods were utilized to quantify both elastic and plastic deformation mechanisms within the strained specimens. Stress concentrations were identified during early stages of plastic deformation, which become candidate necking positions and eventually lead to failure. Additionally, fracture surface analysis implied that these stress concentration locations may be correlated to the fabrication defects, providing insightful guidance for future improvements of the UAM zirconium fabrication process.

36 MATERIALS SCIENCE↗

Irradiation of UC1+x kernels using the MiniFuel vehicle: Microstructure, phase analysis, and initial post-irradiation examination

Uranium carbide is a candidate fuel form for a wide range of advanced reactors, including larger Generation IV reactors as well as small modular reactors and microreactors. However, its commercial deployment timeline faces challenges via traditional qualification approaches. To address this issue, an accelerated fission rate irradiation test was performed to collect basic fuel performance data to inform fuel performance models and potential future integral tests. Hyperstoichiometric UC (UC1+x) kernels were irradiated in the High Flux Isotope Reactor using the MiniFuel irradiation vehicle. The test matrix spanned two temperature regimes (700 °C and 800 °C) and burnup levels (1.8 % FIMA and 2.8 % FIMA). Between 21 and 63 kernels were tested at each unique temperature and burnup condition. As-fabricated microstructural analysis revealed a multiphase composition with UC, UC2, UC2−y, and U-C-O bearing phases for the irradiated kernels. Following irradiation, fission gas release, swelling, and microstructures were analyzed. Measured fission gas release was below 5 % for all irradiation conditions, reaching a maximum at the highest temperature and burnup condition. A binary swelling response was observed; the lower burnup and temperature conditions resulted in negligible swelling, but the higher burnup and temperature conditions produced significant anisotropic swelling and densification in a subset of kernels. The basic microstructural exams of kernels following irradiation were not capable of showing a correlation between kernels that exhibited excessive swelling and those that did not. Characterization of a subset of samples using the Advanced Photon Source and more detailed microstructural examination of unirradiated kernels revealed that a subset of kernels contained very high UC2 phase fractions. The anomalous swelling response is hypothesized to have been driven by this chemical variation. The results of this irradiation highlight the potential of accelerated fission rate irradiation testing to explore such behaviors and inform the development of fuel specifications.

Adorno Lopes, Denise [ORNL] (ORCID:000900023705987↗

Analysis of geometric and electrochemical characteristics of lithium cobalt oxide electrode with different packing densities

In order to investigate geometric and electrochemical characteristics of Li ion battery electrode with different packing densities, lithium cobalt oxide (LiCoO 2 ) cathode electrodes were fabricated from a 94:3:3 (wt%) mixture of LiCoO 2 , polymeric binder, and super-P carbon black and calendered to different densities. A synchrotron X-ray nano-computed tomography system with a spatial resolution of 58.2 nm at the Advanced Photon Source of the Argonne National Laboratory was employed to obtain three dimensional morphology data of the electrodes. The morphology data were then quantitatively analyzed to characterize their geometric properties, such as porosity, tortuosity, specific surface area, and pore size distribution. The geometric and electrochemical analysis reveal that high packing density electrodes have smaller average pore size and narrower pore size distribution, which improves the electrical contact between carbon-binder matrix and LiCoO 2 particles. The better contact improves the capacity and rate capability by reducing the possibility of electrically isolated LiCoO 2 particles and increasing the electrochemically active area. The results show that increase of packing density results in higher tortuosity, but electrochemically active area is more crucial to cell performance than tortuosity at up to 3.6 g/cm 3 packing density and 4 C rate.

25 ENERGY STORAGE↗

Spatial heterogeneity analyses of pore structure and mineral composition of Barnett Shale using X-ray scattering techniques

The spatial heterogeneity of pore structure and mineral composition at mu m to mm scales in mm to cm-sized shale samples complicates the laboratory measurements of porosity & pore size distribution and consequently reservoir quality evaluation. Traditional fluid invasion characterization methods typically take hours to days to get data and can only test relatively small samples (usually 2.54 cm diameter core plugs and mm-sized rock chips). Furthermore, the Xray scattering techniques at the Advanced Photon Source of the Argonne National Laboratory have the capability to non-destructively determine the pore structure and mineral composition of mm x mm area in a short time of seconds and to hold several to hundreds of mm 2 sized sample to conduct large area heterogeneity analysis in the short duration of hours. With the use of ultra-small angle X-ray scattering (USAXS), small-angle X-ray scattering (SAXS), and wide-angle X-ray scattering (WAXS), the porosity, surface area and pore size distribution of two Barnett Shale samples have been mapped out and the mineral compositions are determined qualitatively. Overall, the porosity and pore surface area of the Barnett Shale Sample A over a 36 cm2 area ranges from 1.70 % to 8.13 % and 8.87 m 2 /g to 40.2 m 2 /g respectively. The porosity and surface area of Sample B over a 24 cm 2 area varies from 3.15 % to 11.7 % and 18.3 m 2 /g to 60.2 m 2 /g. In Sample A, the mineral composition shows a shift from carbonate-rich to siliciclastic-rich over a distance of several millimeters. For Sample B, the mineral compositions are mainly siliciclastic and do not show an obvious lithological change. The direct observations of high spatial heterogeneity of pore structure and mineral composition in shale illustrate the utility of integrated X-ray scattering techniques to provide valuable insights into shale studies and reservoir evaluation.

58 GEOSCIENCES↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

Exploring the structure of high temperature, iron-bearing liquids

This paper describes the direct measurements of the structure of iron-bearing liquids using a combination of containerless techniques and in–situ high energy x-ray diffraction. These capabilities provide data that is important to help model and optimize processes such as smelting, steel making, and controlling slag chemistry. A successful programme of liquid studies has been undertaken and the Advanced Photon Source using these combined techniques which include the provision of gas mixing and the control of pO₂ and the changing influence of mixed valance elements. It is possible to combine rapid image acquisition with quenching of liquids to obtain the full diffraction patterns of deeply supercooled liquids and the metastable supercooled liquid regime, where the liquid structures and viscosity change most dramatically, can also be explored.

36 MATERIALS SCIENCE↗

Shock compression of additively manufactured high solids loaded polymer composites with aligned porosity

The effects of aligned porosity on the shock-compression response of additively manufactured (AM) composite structures with collinear and log-cabin geometries are investigated. The composites contain two inorganic and two organic particle populations and a UV-curable polymer binder. X-ray phase contrast imaging (X-PCI) is used as an in-material diagnostic in plate-impact experiments performed at the Dynamic Compression Sector of the Advanced Photon Source at the Argonne National Laboratory. Macroscale shock and particle velocities and microscale pore collapse velocities are measured from X-PCI images obtained from samples impacted in various orientations relative to the AM build directions. The linear shock and particle velocity relation for the structures with collinear build geometry shows directional differences, with the build direction exhibiting the highest slope and the filament print direction having the shallowest slope. Composites with log-cabin geometry, due to their slightly lower porosity and smaller sized pores, show higher shock velocities than the collinear structures at the same particle velocity. Microscale directionality effects are also observed, with the pore collapse velocity dependent on the pore configuration. Specifically, the pore collapse velocity is highest for pores elongated along the impact direction which is the case for the colinear structures impacted in the filament print direction, which is consistent with the directionality trend observed in the data for the shock and particle velocity equation of state. The pore collapse velocity approaches ∼80 % of the shock velocity and is several times the average bulk particle velocity, suggesting a highly hydrodynamic mechanism of pore collapse. Overall, both the macroscale response as measured by the shock and particle velocity relationship, and the microscale response as measured by the pore collapse velocity, are found to be anisotropic and dependent on the AM composite structure.

Wagner, K. B. [Georgia Institute of Technology, At↗

On the influence of monochromator thermal deformations on X-ray focusing

A cooled double crystal monochromator system is used on many high heat load X-ray synchrotron radiation beamlines in order to select, by diffraction, a narrow spectrum of the beam. Thermal deformation of the first crystal monochromator – and the potential loss of beam brightness – is often a concern. However, if downstream beam focusing is planned, the lensing effect of the monochromator must be considered even if thermal deformations are small. In this paper we report on recent experiments at an Advanced Photon Source (APS) beamline that focuses the X-ray beam using compound refractive lenses downstream of an X-ray monochromator system. Increasing the X-ray beam power by increasing the storage ring current from 100 mA to 130 mA resulted in an effective doubling of the focal distance. We show quantitatively that this is due to a lensing effect of the distorted monochromator that results in the creation of a virtual source downstream of the actual source. Lastly, an analysis of the defocusing and options to mitigate this effect are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

In this paper, a four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm 2 and an absorption layer thickness of 110 μ m. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. Finally, for the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A concept for canceling the leakage field inside the stored beam chamber of a septum magnet

Here, the Advanced Photon Source is in the process of upgrading its storage ring from a double-bend to a multi-bend lattice as part of the APS Upgrade Project (APS-U). A swap-out injection scheme is planned for the APS-U to keep a constant beam current and to enable a small dynamic aperture. A novel concept that cancels out the effect of leakage field inside the stored beam chamber was introduced in the design of the septum magnet. As a result, the horizontal deflecting angle of the stored beam was reduced to below 1 µrad with a 2 mm septum thickness and 1.06 T normal injection field. The concept helped to minimize the integrated skew quadrupole field and normal sextupole fields inside stored beam chamber as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast inorganic scintillator-based front imager for Gigahertz Hard X-ray imaging

State-of-the art X-ray imaging cameras using silicon sensors for X-ray detection have demonstrated a frame-rate of 10 MHz and excellent performance for X-ray energies below 20 keV. We proposed a pixelated ultrafast inorganic scintillator-based front imager for GHz hard X-ray imaging. Here, the proposed imager is featured with a total absorption for hard X-ray photons, and provides sub-ns scintillation pulse width crucial for X-ray bunches of a few ns spacing foreseen at the proposed MaRIE facility. We measured temporal response of a dozen ultrafast and fast inorganic scintillators at the 10-ID-B site of the Advanced Photon Source (APS) of ANL. Crystal's response to hybrid X-ray beam of 30 keV, consisting of singlet bunches of 50 ps width and septuplet bunches of 27 ps width with 2.83 ns bunch spacing, was measured. Ultrafast inorganic scintillators, such as BaF 2 :Y and ZnO:Ga, show clearly resolved X-ray bunches for septuplets, as well as no degradation of amplitude for continuous eight septuplets, providing a proof of principle for the ultrafast inorganic scintillator-based total absorption front imager for the proposed MaRIE project.

47 OTHER INSTRUMENTATION↗

Volumetric properties of magnesium silicate glasses and supercooled liquid at high pressure by X-ray microtomography

The volumetric properties of silicate glasses and supercooled liquid are examined at high pressures and temperatures using X-ray computed tomography (CT) and absorption. The high pressure X-ray microtomography (HPXMT) system at the Advanced Photon Source, Argonne National Laboratory (GeoSoilEnvironCARS 13-BM-D beamline) consists of two opposing anvils compressed within an X-ray-transparent containment ring supported by thrust bearings and loaded using a 250-ton hydraulic press. This system permits the pressure cell to rotate under the load, while collecting radiographs through at least 180{sup o} of rotation. The 13-BM-D beamline permits convenient switching between monochromatic radiation required for radiography and polychromatic radiation for pressure determination by energy dispersive diffraction. We report initial results on several refractory magnesium silicate glasses synthesized by levitation laser heating. Volume changes during room temperature compression of Mg-silicate glasses with 33 mol% and 38 mol% SiO2 up to 11.5 GPa give an isothermal bulk moduli of 93--100 GPa for a K' of 1. These values are consistent with ultrasonic measurements of more silica-rich glasses. The volumetric properties of amorphous MgSiO{sub 3} at 2 GPa were examined during annealing up to 1000 C. We consider the consequences of heating through the glass transition and the implications for thermal expansivity of supercooled liquids at high pressure. Our results illustrate the capabilities of HPXMT for studies of refractory glasses and liquids at high pressure and offer strategies for future studies of liquid densities within the melting interval for magmas in planet interiors.

36 MATERIALS SCIENCE↗

Toward comprehensive studies of liquids at high pressures and high temperatures: Combined structure, elastic wave velocity, and viscosity measurements in the Paris-Edinburgh cell

Techniques for measuring liquid structure, elastic wave velocity, and viscosity under high pressure have been integrated using a Paris–Edinburgh cell at Beamline 16-BM-B, HPCAT of the Advanced Photon Source. The Paris–Edinburgh press allows for compressing large volume samples (up to 2 mm in both diameter and length) up to ~7 GPa and 2000 °C. Multi-angle energy dispersive X-ray diffraction provides structure factors of liquid to a large Q of ~19 Å. Ultrasonic techniques have been developed to investigate elastic wave velocity of liquids combined with the X-ray imaging. Falling sphere viscometry, using high-speed X-ray radiography (>1000 frames/s), enables us to investigate a wide range of viscosity, from those of high viscosity silicates or oxides melts to low viscosity (<1 mPa s) liquids and fluids such as liquid metals or salts. The integration of these multiple techniques has promoted comprehensive studies of structure and physical properties of liquids as well as amorphous materials at high pressures and high temperatures, making it possible to investigate correlations between structure and physical properties of liquids in situ.

Kono, Yoshio↗

Determining the influence of temperature and pressure on the structural stability in a polyurea elastomer

The structural response of amorphous elastomers to applied pressure and temperature is of significant interest given their potential for blast and impact protection applications. While understanding disordered structures is often challenging, this study focuses on the ordered correlations that are present at the atomic level even in amorphous materials. This local order was characterized in polyurea elastomers with two molecular weights up to 6 GPa and ~280 °C using in situ energy dispersive X-ray diffraction at the Advanced Photon Source via total scattering techniques. The resulting structure factors and pair distribution functions indicate that the applied pressure reduced the free volume but had little effect on covalent bonds for both molecular weights. Temperature-induced order-disorder transitions that occur readily at ambient pressures within the temperature range studied here were not observed, their onset likely delayed by the limited chain mobility associated with the free volume reduction. In conclusion, this study demonstrates that total scattering offers insights into the high-pressure structure of disordered polymers that are otherwise inaccessible using more conventional X-ray scattering techniques.

42 ENGINEERING↗