Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Feasibility of an image planning system for kilovoltage image-guided radiation therapy

Purpose: Image guidance has become a standard of care for many treatment scenarios in radiation therapy. This is most typically accomplished by use of kV x-ray devices mounted onto the linear accelerator (Linac) gantry that yield planar, fluoroscopic, and cone-beam computed tomography (CBCT) images. Image acquisition parameters are chosen via preset techniques that rely on broad categorizations in patient anatomy and imaging goal. However, the optimal imaging technique results in detectability of the features of interest while exposing the patient to minimum dose. Herein, the authors present an investigation into the feasibility of developing an image planning system (IPS) for radiotherapy.Methods: In this first phase, the authors focused on developing an algorithm to predict tissue contrast produced by a common radiotherapy planar imaging chain. Input parameters include a CT dataset and simulated planar imaging technique settings that include kV and mAs. Energy-specific attenuation through each voxel of the CT dataset was calculated in the algorithm to derive a net transmitted intensity. The response of the flat panel detector was integrated into the image simulation algorithm. Verification was conducted by comparing simulated and measured images using four phantoms. Comparisons were made in both high and low contrast settings, as well as changes in the geometric appearance due to image saturation. Results: The authors studied a lung nodule test object to assess the planning system's ability to predict object contrast and detectability. Verification demonstrated that the slope of the pixel intensities is similar, the presence of the nodule is evident, and image saturation at high mAs values is evident in both images. The appearance of the lung nodule is a function of the image detector saturation. The authors assessed the dimensions of the lung nodule in measured and simulated images. Good quantitative agreement affirmed the algorithm's predictive capabilities. The invariance of contrast with kVp and mAs prior to saturation was predicted, as well as the gradual loss of object detectability as saturation was approached. Small changes in soft tissue density were studied using a mammography step wedge phantom. Data were acquired at beam qualities of 80 and 120 kVp and over exposure values ranging from 0.04 to 500 mAs. The data showed good agreement in terms of the absolute value of pixel intensities predicted, as well as small variations across the step wedge pattern. The saturation pixel intensity was consistent between the two beam qualities studied. Boney tissue contrast was assessed using two abdominal phantoms. Measured and calculated values agree in terms of predicting the mAs value at which detector saturation, and subsequent loss of contrast occurs. The lack of variation in contrast over mAs values lower than 10 suggests that there is wide latitude for minimizing patient dose. Conclusions: The authors developed and tested an algorithm that can be used to assist in kV imaging technique selection during localization for radiotherapy. Phantom testing demonstrated the algorithm's predictive accuracy for both low and high contrast imaging scenarios. Detector saturation with subsequent loss of imaging detail, both in terms of object size and contrast were accurately predicted by the algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test

Astrophysical observations indicate that approximately 85% of the matter in the universe is nonluminous, nonbaryonic, and nonrelativistic (cold) dark matter. Weakly Interacting Massive Particles (WIMPs) are a particularly well motivated dark matter particle candidate. They would be thermally produced in the early universe and their relics account for the current dark matter abundance. WIMP candidate particles are naturally provided by extensions to the Standard Model of particle physics, such as supersymmetry. The Cryogenic Dark Matter Search (CDMS) experiment operates cryogenic germanium and silicon particle detectors in the low-background environment of the Soudan Underground Laboratory in northern Minnesota to search for WIMP-nucleus scatters while rejecting electron-recoil background. The detectors simultaneously measure the ionization and phonon energies of each scattering event. The difference in ionization yield (ratio of ionization energy to recoil energy) discriminates nuclear recoils from the electron-recoil background efficiently.More sensitive detectors are required to probe the WIMP parameter space with lower WIMP-nucleon scattering cross sections. To support the R&D effort especially the detector R&D and characterization of the SuperCDMS experiment, a new CDMS test facility has been developed on the University of Minnesota campus. This thesis documents the test facility and the work involved in its development. In the test facility, we performed the first ionization collection efficiency measurements of the ionization test devices. The test devices are fabricated with detector-grade germanium crystals that are 100 mm in diameter, which is the largest available, and 33 mm in thickness. The measured efficiencies are consistent with the earlier measurements conducted with smaller Ge crystals, demonstrating that these 100 mm crystals can be used for development of the next generation dark matter detectors.Improvements of data analysis methods can also potentially improve the sensitivity of an experiment. The data taken during the last four runs of CDMS II with total raw exposure 612 kg-day were reprocessed with improved ionization pulse reconstruction algorithm. We present the classic timing analysis with the reprocessed data in this thesis. For the four runs combined, this analysis resulted in a new WIMP-nucleon cross section 4.4×10 -44 cm 2 for a WIMP mass of 70 GeV, which is a factor of 1.6 improvement compared to the original c58 classic timing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

A variable-order time-dependent neutron transport method for nuclear reactor kinetics using analytically-integrated space-time characteristics

A new time-dependent neutron transport method based on the method of characteristics (MOC) has been developed. Whereas most spatial kinetics methods treat time dependence through temporal discretization, this new method treats time dependence by defining the characteristics to span space and time. In this implementation regions are defined in space-time where the thickness of the region in time fulfills an analogous role to the time step in discretized methods. The time dependence of the local source is approximated using a truncated Taylor series expansion with high order derivatives approximated using backward differences, permitting the solution of the resulting space-time characteristic equation. To avoid a drastic increase in computational expense and memory requirements due to solving many discrete characteristics in the space-time planes, the temporal variation of the boundary source is similarly approximated. This allows the characteristics in the space-time plane to be represented analytically rather than discretely, resulting in an algorithm comparable in implementation and expense to one that arises from conventional time integration techniques. Furthermore, by defining the boundary flux time derivative in terms of the preceding local source time derivative and boundary flux time derivative, the need to store angularly-dependent data is avoided without approximating the angular dependence of the angular flux time derivative. The accuracy of this method is assessed through implementation in the neutron transport code DeCART. The method is employed with variable-order local source representation to model a TWIGL transient. The results demonstrate that this method is accurate and more efficient than the discretized method. (authors)

97 MATHEMATICS AND COMPUTING↗

MAR ASSESSMENTS OF THE HIGH LEVEL WASTE SYSTEM PLAN REVISION 16

High-level waste (HLW) throughput (i.e., the amount of waste processed per unit of time) is primarily a function of two critical parameters: waste loading (WL) and melt rate. For the Defense Waste Processing Facility (DWPF), increasing HLW throughput would significantly reduce the overall mission life cycle costs for the Department of Energy (DOE). Significant increases in waste throughput have been achieved at DWPF since initial radioactive operations began in 1996. Key technical and operational initiatives that supported increased waste throughput included improvements in facility attainment, the Chemical Processing Cell (CPC) flowsheet, process control models and frit formulations. As a result of these key initiatives, DWPF increased WLs from a nominal 28% for Sludge Batch 2 (SB2) to {approx}34 to 38% for SB3 through SB6 while maintaining or slightly improving canister fill times. Although considerable improvements in waste throughput have been obtained, future contractual waste loading targets are nominally 40%, while canister production rates are also expected to increase (to a rate of 325 to 400 canisters per year). Although implementation of bubblers have made a positive impact on increasing melt rate for recent sludge batches targeting WLs in the mid30s, higher WLs will ultimately make the feeds to DWPF more challenging to process. Savannah River Remediation (SRR) recently requested the Savannah River National Laboratory (SRNL) to perform a paper study assessment using future sludge projections to evaluate whether the current Process Composition Control System (PCCS) algorithms would provide projected operating windows to allow future contractual WL targets to be met. More specifically, the objective of this study was to evaluate future sludge batch projections (based on Revision 16 of the HLW Systems Plan) with respect to projected operating windows using current PCCS models and associated constraints. Based on the assessments, the waste loading interval over which a glass system (i.e., a projected sludge composition with a candidate frit) is predicted to be acceptable can be defined (i.e., the projected operating window) which will provide insight into the ability to meet future contractual WL obligations. In this study, future contractual WL obligations are assumed to be 40%, which is the goal after all flowsheet enhancements have been implemented to support DWPF operations. For a system to be considered acceptable, candidate frits must be identified that provide access to at least 40% WL while accounting for potential variation in the sludge resulting from differences in batch-to-batch transfers into the Sludge Receipt and Adjustment Tank (SRAT) and/or analytical uncertainties. In more general terms, this study will assess whether or not the current glass formulation strategy (based on the use of the Nominal and Variation Stage assessments) and current PCCS models will allow access to compositional regions required to targeted higher WLs for future operations. Some of the key questions to be considered in this study include: (1) If higher WLs are attainable with current process control models, are the models valid in these compositional regions? If the higher WL glass regions are outside current model development or validation ranges, is there existing data that could be used to demonstrate model applicability (or lack thereof)? If not, experimental data may be required to revise current models or serve as validation data with the existing models. (2) Are there compositional trends in frit space that are required by the PCCS models to obtain access to these higher WLs? If so, are there potential issues with the compositions of the associated frits (e.g., limitations on the B{sub 2}O{sub 3} and/or Li{sub 2}O concentrations) as they are compared to model development/validation ranges or to the term 'borosilicate' glass? If limitations on the frit compositional range are realized, what is the impact of these restrictions on other glass properties such as the ability to suppress nepheline formation or influence melt rate? The model based assessments being performed make the assumption that the process control models are applicable over the glass compositional regions being evaluated. Although the glass compositional region of interest is ultimately defined by the specific frit, sludge, and WL interval used, there is no prescreening of these compositional regions with respect to the model development or validation ranges which is consistent with current DWPF operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotic reconnaissance platform. I. Spectroscopic instruments with rangefinders

In this paper, basic principles of the design and implementation of a portable, multi-functional scientific instrument, operating from a robotic reconnaissance mobile platform are discussed. The current version of the instrument includes a multi-gas laser sensor, multi-functional spectrometer, isotopes identifier, cameras, and rangefinder. An additional set of sensors monitors temperature, pressure, humidity, and background radiation. All components are installed on a mini-robotic platform, which provides data acquisition, processing, and transmittance. The design focuses on the development of calibration-free, reliable, low power-consumption devices. To create a highly survivable, accurate, and reliable instrument, a concept of an inhomogeneous sensory network has been developed. Such a network combines non-identical sensors and provides cross-use of information received from different sensors to describe environmental conditions, to choose appropriate algorithms of data processing, and to achieve high accuracy gas-concentration measurements. The system uses the same lasers to operate different optical devices such as sensors, rangefinders, spectrometers, and isotopes identifiers. Among the innovative elements described in this paper, are a calibration-free, laser multi-gas sensor with range-finding option; a high signal/noise ratio transmittance spectrometer; a single-frequency laser with nano-selector; and low repetition-rate femtosecond fiber lasers operating in near- and middle- infrared spectral ranges. New detailed analyses of absorption spectroscopy theoretical approximations made it possible to achieve high-accuracy gas-concentration measurements with miniature optical sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending a Tandem Mass Spectral Library to Include MS{sup 2} Spectra of Fragment Ions Produced In-Source and MS{sup n} Spectra

Tandem mass spectral library searching is finding increased use as an effective means of determining chemical identity in mass spectrometry-based omics studies. We previously reported on constructing a tandem mass spectral library that includes spectra for multiple precursor ions for each analyte. Here we report our method for expanding this library to include MS{sup 2} spectra of fragment ions generated during the ionization process (in-source fragment ions) as well as MS{sup 3} and MS{sup 4} spectra. These can assist the chemical identification process. A simple density-based clustering algorithm was used to cluster all significant precursor ions from MS{sup 1} scans for an analyte acquired during an infusion experiment. The MS{sup 2} spectra associated with these precursor ions were grouped into the same precursor clusters. Subsequently, a new top-down hierarchical divisive clustering algorithm was developed for clustering the spectra from fragmentation of ions in each precursor cluster, including the MS{sup 2} spectra of the original precursors and of the in-source fragments as well as the MS{sup n} spectra. This algorithm starts with all the spectra of one precursor in one cluster and then separates them into sub-clusters of similar spectra based on the fragment patterns. Herein, we describe the algorithms and spectral evaluation methods for extending the library. The new library features were demonstrated by searching the high resolution spectra of E. coli extracts against the extended library, allowing identification of compounds and their in-source fragment ions in a manner that was not possible before. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DES science portal: Computing photometric redshifts

We present the Dark Energy Survey (DES) Science Portal, an integratedweb-based data interface designed to facilitate scientific analysis. Wedemonstrate how the Portal can provide a reliable environment to accesscomplete data sets, provide validation algorithms and metrics in the case ofmultiple methods and training configurations, and maintain the provenancebetween the different steps of a complex calculation, while ensuringreproducibility of the results. We use the estimation of DES photometricredshifts (photo-$z$s) as an example. A significant challenge facingphotometric surveys for cosmological purposes, such as DES, is the need toproduce reliable redshift estimates. The choice between competing algorithmsand configurations and the maintenance of an up-to-date spectroscopic databaseto build training sets, for example, are complex tasks when dealing with largeamounts of data that are regularly updated and constantly growing. We show howthe DES Science Portal can be used to train and validate several photo-$z$algorithms using the DES first year (Y1A1) data. The photo-$z$s estimated inthe Portal are used to feed the creation of catalogs for scientific workflows.While the DES collaboration is still developing techniques to obtain precisephoto-$z$s, having a structured framework like the one presented here iscritical for the systematic vetting of DES algorithmic improvements and theconsistent production of photo-$z$s in future DES releases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of the Two Track Charged Current Quasi-Elastic Cross Section with the MINER$\nu$A Detector

The MINER$\nu$A detector collected 1.2 × 10 20 POT of $\nu$ μ data with the NuMI beam at Fermi National Laboratory from 03/2010 to 07/2010. I will describe an analysis to identify two track charged current muon neutrino quasi-elastic interactions using this data set. The final state muon was identified by curvature using the MINOS detector. The final state contained proton was identified by the energy deposited per unit length at the end of the track. Two additional cuts were applied to separate signal from background: a cut on the extra energy in the event and a cut on a proton energy dependent variable. The dσ/dQ2 using this selection is presented. An initial list of systematic errors is introduced and calculated. In addition to this analysis work, I also developed both pattern recognition schemes used by the experiment, wrote MINOS muon track matching algorithms, implemented a Kalman Filter track fitting algorithm and contributed to various other tasks to the MINER$\nu$A experiment; I will provide an explanation of these. I will also give a brief overview of neutrino physics, the NuMI beam, and the MINER$\nu$A detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance analysis of distributed symmetric sparse matrix vector multiplication algorithm for multi-core architectures

In this article, sparse matrix vector multiply (SpMVM) is an important kernel that frequently arises in high performance computing applications. Due to its low arithmetic intensity, several approaches have been proposed in literature to improve its scalability and efficiency in large scale computations. In this paper, our target systems are high end multi-core architectures and we use messaging passing interface + open multiprocessing hybrid programming model for parallelism. We analyze the performance of recently proposed implementation of the distributed symmetric SpMVM, originally developed for large sparse symmetric matrices arising in ab initio nuclear structure calculations. We also study important features of this implementation and compare with previously reported implementations that do not exploit underlying symmetry. Our SpMVM implementations leverage the hybrid paradigm to efficiently overlap expensive communications with computations. Our main comparison criterion is the "CPU core hours" metric, which is the main measure of resource usage on supercomputers. We analyze the effects of topology-aware mapping heuristic using simplified network load model. Furthermore, we have tested the different SpMVM implementations on two large clusters with 3D Torus and Dragonfly topology. Our results show that the distributed SpMVM implementation that exploits matrix symmetry and hides communication yields the best value for the "CPU core hours" metric and significantly reduces data movement overheads.

97 MATHEMATICS AND COMPUTING↗

Optimization of a parallel hole collimator/CdZnTe gamma-camera architecture for scintimammography

Purpose: Small field-of-view CdZnTe (CZT) gamma cameras are increasingly studied for breast lesion detection to complement mammography or ultrasonographic findings. However, in classical collimation configurations, they remain limited by the trade-off between spatial resolution and sensitivity. The HiSens architecture was proposed to overcome these limitations. Using an accurate 3D localization of the interactions inside the detector, this architecture leads to a gain in sensitivity without loss in spatial resolution. In this article, the relevance of the HiSens architecture for planar scintimammography is studied. Methods: A detective quantum efficiency (DQE) computation method is developed and used to optimize the dimensioning of a parallel hole collimator dedicated to scintimammography. Based on the DQE curves, the impact of the collimator-to-detector distance is studied. Two algorithms are proposed to combine data acquired with different collimator-to-detector distances. Results: It is shown that CZT detector virtual pixelization increases system sensitivity by 3.3 while preserving a standard LEHR spatial resolution. The introduction of a gap between the CZT detector and the collimator is useful to modulate the DQE curve shape. The combination of data acquired using different gaps in the image formation process leads to enhanced restoration of the frequency content of the images, resulting in image contrast and spatial resolution improvements. Conclusions: Acquisition duration or injected activity could be markedly reduced if the HiSens architecture with an appropriate collimator-detector gap were used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a transportable high efficiency fast neutron spectrometer

A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV and a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2 . For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2 . As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed modeling of fission with F R E Y A

For many years, the state of the art for treating fission in radiation transport codes has involved sampling from average distributions. However, such “average” fission models have limited interaction-by-interaction capabilities. Energy is not explicitly conserved and no correlations are available because all particles are emitted isotropically and independently. However, in a true fission event, the energies, momenta and multiplicities of emitted particles are correlated. Such correlations are interesting for many modern applications, including detector development and detection of small amounts of special material. Recently, several Monte Carlo codes have become available that calculate complete fission events. Event-by-event techniques are particularly useful because it is possible to obtain the fission products as well as the prompt neutrons and photons emitted during an individual fission process, all with complete kinematic information. It is therefore possible to extract any desired correlation observables. Such codes, when included in broader Monte Carlo transport codes, such as MCNP, can be made broadly available to the community. One such code, FREYA (Fission Reaction Event Yield Algorithm), is particularly fast and can readily generate large samples of complete fission events. We briefly describe here the physics in FREYA and compare our results with relevant available data on prompt neutron and photon emission. We discuss correlated measurements in particular for validation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Se-SAD serial femtosecond crystallography datasets from selenobiotinyl-streptavidin

We provide a detailed description of selenobiotinyl-streptavidin (Se-B SA) co-crystal datasets recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS) for selenium single-wavelength anomalous diffraction (Se-SAD) structure determination. Se-B SA was chosen as the model system for its high affinity between biotin and streptavidin where the sulfur atom in the biotin molecule (C 10 H 16 N 2 O 3 S) is substituted with selenium. The dataset was collected at three different transmissions (100, 50, and 10%) using a serial sample chamber setup which allows for two sample chambers, a front chamber and a back chamber, to operate simultaneously. Diffraction patterns from Se-B SA were recorded to a resolution of 1.9 Å. The dataset is publicly available through the Coherent X-ray Imaging Data Bank (CXIDB) and also on LCLS compute nodes as a resource for research and algorithm development.

36 MATERIALS SCIENCE↗

Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source

Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65–70 nm, which is considerably smaller than the previously reported ~600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. As a result, the data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilizing the Dynamic Networks Data Processing and Analysis Experiment (DNE18) to Establish Methodologies for the Comparison of Automatic Infrasonic Signal Detectors

The Dynamic Networks Experiment 2018 (DNE18) was a collaborative effort between Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), Lawrence Livermore National Laboratory (LLNL) and Pacific Northwest National Laboratory (PNNL) designed to evaluate methodologies for multi-modal data ingestion and processing. One component of this virtual experiment was a quantitative assessment of current capabilities for infrasound data processing, beginning with the establishment of a baseline for infrasound signal detection. To produce such baselines, SNL and LANL exploited a common dataset of infrasound data recorded across a regional network in Utah from December 2010 through February 2011. We utilize two automated signal detectors, the Adaptive F-Detector (AFD) and the Multivariate Adaptive Learning Detector (MALD) to produce automated signal detection catalogs and an analyst-produced catalog. Comparisons indicate that automatic detectors may be able to identify small amplitude, low SNR events that cannot be identified by analyst review. We document detector performance in terms of precision and recall, demonstrating that the AFD is more precise, but the MALD has higher recall. We use a synthetic dataset of signals embedded in pink noise in order to highlight shortcomings in assessing detection algorithms for low signal to noise ratio signals which are commonly of interest to the nuclear monitoring community. For comparisons utilizing the synthetic dataset, the AFD has higher recall while precision is equal for both detectors. These results indicate that both detectors perform well across a variety of background noise environments; however, both detectors fail to identify repetitive, short duration signals arriving from similar backazimuths. These failures represent specific scenarios that could be targeted for further detector development.

97 MATHEMATICS AND COMPUTING↗

OpenCV and TYZX : video surveillance for tracking.

As part of the National Security Engineering Institute (NSEI) project, several sensors were developed in conjunction with an assessment algorithm. A camera system was developed in-house to track the locations of personnel within a secure room. In addition, a commercial, off-the-shelf (COTS) tracking system developed by TYZX was examined. TYZX is a Bay Area start-up that has developed its own tracking hardware and software which we use as COTS support for robust tracking. This report discusses the pros and cons of each camera system, how they work, a proposed data fusion method, and some visual results. Distributed, embedded image processing solutions show the most promise in their ability to track multiple targets in complex environments and in real-time. Future work on the camera system may include three-dimensional volumetric tracking by using multiple simple cameras, Kalman or particle filtering, automated camera calibration and registration, and gesture or path recognition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

LDRD Abbreviated report: High-Order General-Discrete-Ordinates Method Enabling Efficient Deterministic Transport in Hydrodynamic Simulations

Deterministic transport simulations for national-security and energy applications often operate in high-dimensional phase-space, where accuracy and cost both become major challenges. A common numerical artifact in such problems is the “ray-effect,” which appears as unphysical streaks. Beyond misinterpretation, these artifacts can contaminate tightly coupled physics, such as fluid dynamics, radiation-hydrodynamics, and laser-plasma interactions, eroding the predictive capability of entire multiphysics workflows. Our objective was to make high-dimension studies practical on modern hardware while mitigating the ray-effect without relying on prohibitively expensive sampling approaches such as Monte Carlo methods. We developed the Generic Discretization Library (GenDiL), a Graphics Processing Unit (GPU)-first framework that uses high-order Discontinuous Galerkin (DG) methods and matrix-free algorithms to reduce memory usage and improve computational efficiency, critical for phase-space simulations. GenDiL supports phase-space adaptivity in both mesh size and polynomial order (hp-adaptivity) to place resolution only where it is needed. A central capability is Local Dimensional Refinement (LDR), which couples lower-dimension continuum models to higher-dimension kinetic models through stable and conservative interfaces, so that high-fidelity physics is applied only in regions where it is essential. Building on the GenDiL framework, we developed the General SN (GSN) family of algorithms as a true generalization of the polar SN approach (discrete ordinates, often denoted SN). Rather than tying discrete ordinates to a specific polar change of coordinates, GSN formulates transport on an arbitrary change of coordinates chosen to reduce ray-effect. We studied two complementary variants: an analytic variant, where the coordinate map is prescribed in advance by a closed-form function; and a data-driven variant, where a quantity of interest, such as the net flux, guides the coordinate system. GenDiL provides the library infrastructure for efficient GPU execution, but the GSN concept is algorithmic and independent of any one library. Across representative high-dimension tests, including non-symmetric solutions, both variants delivered strong ray-effect mitigation at practical cost, moving four- to six-dimensional analysis toward repeatable, routine studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Long-term Monitoring of Radiation Air Dose Rates - 19169

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (NPP) have been steadily decreasing over the past seven years since the accident in March 2011. After seven years, the radiation monitoring program is expected to transition from short-term emergency responses to long-term monitoring. The objectives of long-term monitoring are often different from early emergency responses, since extensive data accumulation has led to an understanding of contaminant distributions and mobility. The main long-term monitoring objectives are (1) to confirm system stability and the continuing reduction of contaminant and hazard levels, (2) to provide assurance for the public, (3) to accumulate the basic datasets for scientific knowledge and future preparation, and (4) to detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the sampling locations of radiation air dose-rate monitoring. Three steps are taken in order to determine sampling locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations across the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air dose rates across the domain. In the second step, we use a Gaussian mixture model to identify the representative locations in multiple environmental variables, such as elevation and land-cover types. In the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air dose rates across the domain. We use the integrated dose-rate map from the Bayesian geostatistical method as the reference map and distribute the sampling in such a way as to capture the heterogeneity of the reference map. Although we assume hypothetical sets of measurement locations to evaluate the performance of the methodology and algorithms, we have demonstrated this approach using real, spatially extensive datasets, including the integrated air-dose-rate map of 2016. Our results have shown that this approach allows us to add sampling locations in a systematic manner. Increasing the number of sampling locations can better capture the heterogeneity of dose rates, although the estimation error does not decrease further after a certain number of samples. We have also found that when there are restrictions such as pre-existing monitoring locations or the ones along roads, the spatial estimation becomes poor even with the same number of monitoring locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗