Search NASA⌕ Search

SEARCH · Search NASA

Results for “BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

Search for Majorana Neutrinos with the Complete KamLAND-Zen Dataset

We present a search for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay of 136 Xe using the full KamLAND-Zen 800 dataset with 745 kg of enriched xenon, corresponding to an exposure of 2.1 ton yr of 136 Xe. This updated search benefits from a more than twofold increase in exposure, recovery of photo-sensor gain, and reduced background from muon-induced spallation of xenon. Combining with the search in the previous KamLAND-Zen phase, we obtain a lower limit for the 0⁢𝜈⁢𝛽⁢𝛽 decay halflife of 𝑇$^{0⁢𝜈}_{1/2}$ >3.8 ×10 26 yr at 90% CL, a factor of 1.7 improvement over the previous limit. The corresponding upper limits on the effective Majorana neutrino mass are in the range 28–122 meV using phenomenological nuclear matrix element calculations.

Abe, S. [Tohoku University] (ORCID:000000022110513↗

State-of-the-art γ-ray assay of 86 Y for medical imaging

An emerging direction in nuclear medicine is the coupling of a therapeutic isotope with an imaging isotope to form a so-called theranostic pair, which allows one to quantitatively track and image the delivery of the therapeutic isotope. 90 Y is used in several therapy applications and a convenient candidate imaging partner is the positron emitter 86 Y. A 27.6 MBq source of 86 Y was produced at the University of Wisconsin and assayed with the Gammasphere array at Argonne National Laboratory. Over 200 γ-ray transitions were identified, more than double that which was previously known. In conclusion, the positron emission probability inferred from the present level scheme leads to 27.9(12)%, an important (≈14%) reduction with respect to the previously recommended value.

59 ≤ A ≤ 89↗

Isospin mixing and the cubic isobaric multiplet mass equation in the lowest T=2, A=32 quintet

The isobaric multiplet mass equation (IMME) is known to break down in the first T=2,A=32 isospin quintet. In this work we combine high-resolution experimental data with state-of-the-art shell-model calculations to investigate isospin mixing as a possible cause for this violation. The experimental data are used to validate isospin-mixing matrix elements calculated with newly developed shell-model Hamiltonians. Our analysis shows that isospin mixing with nonanalog T=1 states contributes to the IMME breakdown, making the requirement of an anomalous cubic term inevitable for the multiplet.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Establishing the ground-state spin of 71 Kr

Nuclei in the vicinity of the N=Z line provide many sensitive probes of isospin symmetry. One example concerns the character and sequence of low-lying states of the T=1/2 mirror pair 71 Kr and 71 Br which has been under debate for several decades. In this paper we report a new measurement of the absolute β-branching to ground and excited states which, taken with our precise lifetime of T 1/2 =94.9(4) ms , gives a superallowed ground state–to–ground state log (ft) value of 3.64(4). This is only consistent with both 71 Br and 71 Kr having the same spin and parity, J π =5/2 – , as expected from mirror symmetry. The β-delayed proton emission to the first-excited state in 70 Se was observed for the first time which also strongly supports this assignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Muon capture on Li 6 , C 12 , and O 16 from ab initio nuclear theory

Muon capture on nuclei is one of the most promising probes of the nuclear electroweak current driving the yet-hypothetical neutrinoless double-beta (0νββ) decay. Both processes involve vector and axial-vector currents at finite momentum transfer, q ~ 100 MeV, as well as the induced pseu doscalar and weak-magnetism currents. Comparing measured muon-capture rates with reliable ab initio nuclear-theory predictions could help us validate these currents. To this end, we compute partial muon-capture rates for 6 Li, 12 C and 16 O, feeding the ground and excited states in 6 He, 12 B and 16 N, using ab initio no-core shell model with two- and three-nucleon chiral interactions. Here, we remove the spurious center-of-mass motion by introducing translationally invariant operators and approximate the effect of hadronic two-body currents by Fermi-gas model. We solve the bound-muon wave function from the Dirac wave equations in the Coulomb field created by a finite nucleus. We find that the computed rates to the low-lying states in the final nuclei are in good agreement with the measured counterparts. We highlight sensitivity of some of the transitions to the sub-leading three-nucleon interaction terms. We also compare summed rates to several tens of final states with the measured total capture rates and note that we slightly underestimate the total rate with this simple approach due to limited range of excitation energies

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the free neutron lifetime in a magneto-gravitational trap with in situ detection

Here, in this study, we publish three years of data from the UCNτ experiment performed at the Los Alamos Ultracold Neutron Facility at the Los Alamos Neutron Science Center. These data are in addition to our previously published data. Our goals in this paper are to better understand and quantify systematic uncertainties and to improve the lifetime statistical precision. We previously reported a value from our 2017–2018 data for the neutron lifetime of 877.75 ± 0.28 (statistical) +0.22–0.16 (systematic) s. We have collected an additional three years of data reported here for the first time. When all the data from UCNτ are averaged for 2017, 2018, 2020, 2021, and 2022, we report an updated value for the lifetime of 877.83 ± 0.22 (statistical)+0.20–0.17 (systematic) s. We utilized improved monitor detectors, reduced our correction due to UCN upscattering on residual gas, and employed four different UCN detector geometries both to reduce the correction required for rate dependence and to explore potential contributions due to phase space evolution.

Cabibbo-Kobayashi-Maskawa matrix↗