Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

A modeling framework for designing and evaluating curbside traffic management policies at Dallas-Fort Worth International Airport

Emerging mobility technologies are changing the transportation system landscape. This is especially evident at airports, such as the Dallas-Fort Worth International Airport (DFW). Without careful analysis, these changes could lead to inefficient and costly airport operations. This paper presents a modeling framework that integrates travel mode encoding, demand projection, and microsimulation to enable airports to develop, simulate, and evaluate curbside traffic managements policies and measure their impact. Here, the framework is utilized to analyze several traffic scenarios and policies for DFW: a baseline scenario which represents DFW traffic pattern as observed in 2018 and projected to 2045, a transit network company (TNC) electrification policy, a TNC queuing policy, a policy that increased transit ridership, a bus-only policy which considers the use of only buses inside DFW, an autonomous vehicle (AV) policy which investigates the impact of autonomous vehicle (AV) adoption on airport operations, and an example COVID-19 scenario which models the impact of the COVID19 pandemic. The simulations’ results demonstrate that: increasing the DFW transit ridership postpones the need for airport curbside expansion the most; encouraging shared-mobility with the bus-only policy produces the most savings in curbside congestion delays; automation and electrification for all passenger vehicle trips to/from DFW generates the most saving in fuel consumption and emissions; and uncontrolled AV adoption incurs the highest increase in fuel consumption, delay, and emissions and could require immediate airport capacity extension. Without policy intervention or investment in additional infrastructure capacity, these results predict the current operations would face significant congestion on high demand days starting as early as 2028. While derived in close partnership with DFW, the methodology presented here can be generalized to any airport.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The LSBmax algorithm for boosting resilience of electric grids post (N‐2) contingencies

Abstract A computationally improved algorithm is presented to find the best transmission switching (TS) candidate for boosting resilience of electricity grids subject to ( N ‐2) contingencies. Here, resilience is computed as the reduction in load shed after the above‐mentioned ( N‐ ) contingencies. TS is a planned line outage, and past research shows that changing the transmission system's topology changes the power flow and removes post contingency violations. Finding the best TS candidate in a computationally suitable time for effectively boosting resilience is a challenge. The best TS candidate is found using a novel heuristic method by decreasing the search space based on proximity to the bus with the maximum load shedding (LSB). The LSB algorithm is faster than existing algorithms in the literature; and, it is compatible with both the AC and DC optimal power flow formulations. To validate the authors' claims of speedup and accuracy, two metrics are used to analyze the results from the IEEE 39‐bus and 118‐bus systems. Finally, the inherent parallelism of the LSB algorithm is leveraged on a high‐performance computing platform and applied to the large‐scale Polish 2383‐bus test system to validate scalability in both size and speedup in computation time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduce, reuse, recycle for robust cluster-state generation

Efficient generation of cluster states is crucial for engineering large-scale measurement-based quantum computers. Hybrid matter-optical systems offer a robust, scalable path to this goal. Such systems have an ancilla which acts as a bus connecting the qubits. We show that by generating the cluster in smaller sections of interlocking bricks, reusing one ancilla per brick, the cluster can be produced with maximal efficiency, requiring fewer than half the operations compared with no bus reuse. By reducing the time required to prepare sections of the cluster, bus reuse more than doubles the size of the computational workspace that can be used before decoherence effects dominate. A row of buses in parallel provides fully scalable cluster-state generation requiring only 20 controlled-phase gates per bus use.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Control Strategy of Grid Interface for EV High-Power Dynamic Wireless Charging

This paper proposes a control strategy for the grid interface converter in high-power dynamic wireless charging system (DWCS) to address two issues on distribution network integration. Due to the unique pulsating load profile of DWCS, load transient response capability is critical for the grid interface to maintain the dc-bus voltage stable. Besides, the inherent unbalanced situation of distribution network would lead to 2nd-order oscillations on the dc-bus voltage, which would further affect the stable operation of the entire system. In this paper, the DWCS model is developed, and the relationship between the dc-bus voltage and the input/output power is analyzed. Based on the developed model, a control strategy based on direct power control is presented. Both simulation results and hardware-in-the-loop (HIL) results demonstrate that the proposed control strategy not only improves load transient response capability, but also eliminates the 2nd-order oscillations on the dc-bus voltage under imbalanced distribution network conditions.

Zeng, Rong↗

Enhanced Large-Signal Stability Method for Grid-Forming Inverters During Current Limiting: Preprint

Grid-forming (GFM) inverters are a promising technology for the widespread integration of renewable energy sources in future power systems. As a key element of GFM inverter control, the primary controller governs the internal reference voltage and angle. During contingencies in the grid---such as faults, voltage drops, or frequency and phase jumps---an inverter can be forced into a current-limiting mode of operation modulating inverter dynamics, and, as a result, it is prone to losing synchronism with the grid. In this paper, we propose a novel GFM primary control method with an additional synchronization term that naturally activates during contingencies to improve the dynamic response. The method allows the inverter to remain synchronized with the grid, which improves the inverter's dynamic behavior both during and after current-limiting grid conditions and enhances grid support, including voltage support using full current capacity. The method is demonstrated for voltage, frequency, and phase jumps both in a single-machine-to-infinite-bus and a network-wide electromagnetic transient simulation of the IEEE 14-bus system with 5 GFM inverters. The simulations provide insights into the proposed synchronization method and confirm the high potential of the method, which robustly secures synchronism under severe contingencies.

current limiting↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighbouring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchains↗

Accelerating the Gauss-Seidel Power Flow Solver on a High Performance Reconfigurable Computer

The computationally intensive power flow problem determines the voltage magnitude and phase angle at each bus in a power system for hundreds of thousands of buses under balanced three-phase steady-state conditions. We report an FPGA acceleration of the Gauss-Seidel based power flow solver employed in the transmission module of the GridLAB-D power distribution simulator and analysis tool. The prototype hardware is implemented on an SGI Altix-RASC system equipped with a Xilinx Virtex II 6000 FPGA. Due to capacity limitations of the FPGA, only the bus voltage calculations of the power network are implemented on hardware while the branch current calculations are implemented in software. For a 200,000 bus system, the bus voltage calculation on the FPGA achieves a 48x speed-up with PQ buses and a 62 times for PV over an equivalent sequential software implementation. The average overall speed up of the FPGA-CPU implementation with 100 iterations of the Gauss-Seidel power solver is 2.6x over a software implementation, with the branch calculations on the CPU accounting for 85% of the total execution time. The FPGA-CPU implementation also shows linear scaling with increase in the size of the input power network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Embedding spatial decomposition in parareal in time power system simulation

We propose an approach for combining two decompositions in power system simulation, temporal and spatial, with a goal to achieve faster simulation time than utilizing either one of them alone. The proposed approach builds upon the structure of the Parareal algorithm for temporal decomposition and explores an efficient way of embedding the spatial decomposition into its coarse and fine solutions. This introduces two types of simultaneous parallelism in power system simulations - parallelism between system areas and between coarse integration intervals for time integration. The results from the application of the proposed approach are shown on a two-area system comprised of the IEEE 16-machine, 68-bus, and the IEEE 50-machine, 145-bus system.

Duan, Nan↗

Practical Implementation of Synchrophasor Based Real-Time Contingency Analysis

Synchrophasor technology is increasingly accepted and adopted by the power industry. Linear State Estimator (LSE) is a recent development in the synchrophasor industry, and has been integrated and deployed at control centers, providing improved coverage and greater reliability from synchrophasor systems. This paper describes a first-of-a-kind synchrophasor based real-time contingency analysis (RTCA), which takes the LSE solved case as input, and then solves the what-if cases to provide timely information about impending grid problems to system operators. Test results on IEEE 39 bus and 300 bus system demonstrate the accuracy of the method for solving the RTCA problem using synchrophasor data. With this the synchrophasor measurement system provides an independent real-time monitoring and operation system which utilizes PMU data alone.

Nayak, Neeraj↗

Coherency-Constrained Spectral Clustering for Power Network Reduction

This paper presents a methodology for reducing the complexity of large-scale power network models using spectral clustering, aggregation of electrical components, and cost function approximation. Two approaches are explored using unconstrained and constrained spectral clustering to determine areas for effective system reduction. Once the system areas are determined, both loads and generators by type are aggregated, and their new cost function is approximated through polynomial curve-fitting or statistical methods. The performance of reduced networks is evaluated in terms of their ability to follow the true daily cost of the original system over a 24-hour period considering a set of several days. Two test systems are taken as test beds. Application of the methodology to a modified version of the IEEE 39-bus system reduces it from 17 generators to a 4-bus system and 9 generators with about 93% of accuracy. Similarly, the IEEE 118-bus system is reduced from 19 generators to a 3-bus system with three aggregated units achieving over 99% of accuracy. These findings address scalability challenges and enhance accuracy for high and mid-loading level conditions, and by aggregating thermal units with similar cost functions.

42 ENGINEERING↗

A Benchmark Case for the Grid Survivability Analysis

Among current priorities of the power system analysis is the development of metrics and computational tools for the resilience analysis during catastrophic events. New methods and tools are required for such an analysis and they have to be validated prior application to real systems. However, benchmark problems are not readily available due to the analysis novelty. The current paper presents a case based on the IEEE 14-bus system for this purpose. The grid is simplified to a graph with nodes representing generators, loads, and buses. Power inputs are imported from real-time simulations of the IEEE 14-bus system. Outcomes of all possible combinations of failed elements are presented in terms of probabilities for the grid to survive, partially survive, or fail. Only the power grid's ability to withstand adverse events (survivability) is analyzed. The grid's recoverability, the other part of the resilience analysis, is not considered.

power system↗

Exact Optimal Power Dispatch in Unbalanced Distribution Systems With High PV Penetration

Smart inverters provide additional control capability to help optimize the operation of distribution systems. This paper proposes a framework for exact optimal active and reactive power dispatch of distributed photovoltaic (PV) generation, switched capacitors, and tap changers in large multi-phase unbalanced distribution systems. The objectives of the optimal dispatch are minimization of the energy loss, PV active power curtailment, and capacitor and tap changer switching operations, in addition to elimination of voltage violations and reverse power flow. The optimization problem is formulated in rectangular coordinates as a nonlinear, nonconvex problem. Effective computational strategies are proposed to allow the application of predictorcorrector primal-dual interior point method to solve optimization problems in real-time with a large number of constraints and variables, including discrete variables corresponding to switched capacitors and tap changers. The accuracy of the numerical solution and the ability to implement the proposed framework are validated using the unbalanced multi-phase IEEE 34-bus and EPRI 2,998-bus distribution systems with 15-minute load and PV data. The results show a significant loss reduction and complete removal of both voltage violations and reverse power flow.

Nguyen, Quan (ORCID:0000000347769557)↗

Power System Recovery from Momentary Cessation with Transient Stability Improvement

Power system dynamics will be significantly changed by integrating wind farms and solar photovoltaic plants into power systems. This study investigates the effect of momentary cessation of inverter-based resources (IBRs) on transient stability and provides a recovery strategy for bulk IBRs in power systems. The theoretical analysis was initially carried out on a one-machine infinite-bus system, demonstrating the IBR impact in a critical group. The analysis was then expanded to a multimachine power system with IBRs using the single-machine equivalent method. The study found that IBRs in critical and noncritical groups exert contrasting effects on transient stability. Finally, a strategy for enhancing transient stability is proposed by controlling IBRs during power system recovery. The proposed strategy was verified by simulation on IEEE 9-bus and IEEE 39-bus power systems with the addition of IBRs. A 39-bus power system simulation demonstrates the scalability of the proposed method. Here, the proposed strategy provides effective and executable measures for improving system security in the presence of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Supportive Loads - A New Approach to Increasing Renewable Energy in Power Systems

This paper demonstrates the potential of inverter-based loads to support grid reliability during power system transients thereby enabling reliable integration of renewable energy in power systems. Such loads are referred to in this paper as grid-supportive loads (GSLs). A new GSL model is developed that simulates the transient response capabilities that can be programmed in electronic loads. The model’s design enables it to be easily integrated in widely used commercial power system transient analysis software. Theoretical expressions are derived that explain the workings of the GSL model. The performance, numerical stability, and impact of the GSL model is validated on 9-bus and 2000-bus synthetic power system models using generator tripping and bus fault disturbances. Results on the 2000 bus system show that in the absence of frequency support from wind/solar generation resources, just 20% of loads with grid-supportive capabilities can improve frequency response by up to 2000 MW/0.1 Hz and reduce deviation in frequency at nadir by up to 60% compared to the situation when GSLs are absent. Power system reliability also improves under fault events. Here, it is further shown that GSLs can aid in integrating more renewable generation without degrading the overall transient response of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reevaluating Contour Visualizations for Power Systems Data

Effective visual analytics tools are needed now more than ever as emerging energy systems data and models are rapidly growing in scale and complexity. Here we examined the suitability of colored contour maps to visually represent bus values in two different power system models: a dense 24k-bus distribution system and a 240-bus transmission system. In a quantitative analysis, we found that contour maps misrepresent power systems data, changing the statistical dispersion of the bus values, including the loss of extreme values. In a controlled empirical study with thirty professional power system research engineers, we found that these distortions significantly impact excursion identification tasks. Additionally, the engineers were less confident in their assessments using contour-based visualizations than glyph-based visualizations.

24 POWER TRANSMISSION AND DISTRIBUTION↗