Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

CRM Assessment: Determining the Generalization of Rater Calibration Training. Summary of Research Report: Gold Standards Training

The extent to which pilot instructors are trained to assess crew resource management (CRM) skills accurately during Line-Oriented Flight Training (LOFT) and Line Operational Evaluation (LOE) scenarios is critical. Pilot instructors must make accurate performance ratings to ensure that proper feedback is provided to flight crews and appropriate decisions are made regarding certification to fly the line. Furthermore, the Federal Aviation Administration's (FAA) Advanced Qualification Program (AQP) requires that instructors be trained explicitly to evaluate both technical and CRM performance (i.e., rater training) and also requires that proficiency and standardization of instructors be verified periodically. To address the critical need for effective pilot instructor training, the American Institutes for Research (AIR) reviewed the relevant research on rater training and, based on "best practices" from this research, developed a new strategy for training pilot instructors to assess crew performance. In addition, we explored new statistical techniques for assessing the effectiveness of pilot instructor training. The results of our research are briefly summarized below. This summary is followed by abstracts of articles and book chapters published under this grant.

Baker, David P.↗

Accuracy Evaluation of Electron-Probe Microanalysis as Applied to Semiconductors and Silicates

An evaluation of precision and accuracy will be presented for representative semiconductor and silicate compositions. The accuracy of electron-probe analysis depends on high precision measurements and instrumental calibration, as well as correction algorithms and fundamental parameter data sets. A critical assessment of correction algorithms and mass absorption coefficient data sets can be made using the alpha factor technique. Alpha factor analysis can be used to identify systematic errors in data sets and also of microprobe standards used for calibration.

Carpenter, Paul↗

Evaluation of Envelope Energy in a High-Performance Manufactured Home in California

There are important applications for a robust energy model for new construction manufactured homes that can characterize the individual performance of the opaque wall and ceiling components of the building envelope. The efficacy of different insulation materials can be assessed with the confidence that modeled performance will closely predict installed performance. This study uses careful calibration of a standard energy model with a short-term co-heating test in an installed manufactured home to de-aggregate the contributions of planar wall sections from overall building envelope thermal resistance. The methodology takes into account thermal mass effects, solar gains, and physical adjustments to the structure to achieve successful calibration and to inform adjustments to the test procedure for future study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Photovoltaic Engineering

The Ohio Aerospace Institute through David Scheiman and Phillip Jenkins provided the Photovoltaics Branch at the NASA Glenn Research Center (GRC) with expertise in photovoltaic (PV) research, flight experiments and solar cell calibration. NASA GRC maintains the only world-class solar cell calibration and measurement facility within NASA. GRC also has a leadership role within the solar cell calibration community, and is leading the effort to develop ISO standards for solar cell calibration. OAI scientists working under this grant provided much of the expertise and leadership in this area.

Source record↗

Results from the first international AM0

AM0 solar cell calibration laboratories throughout the world are working together to create standard methods for AM0 calibration. In an effort to compare the results of different calibration methods, five different laboratories calibrated GaAs and Si solar cells. The results of this inter-comparison are presented herein.

round robin solar cells AM0 silicon GaAs internati↗

Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

SERTS-95 Measurements of Wavelength Shifts in Coronal Emission Lines Across a Solar Active Region

We used slit spectra from the 1995 flight of Goddard Space Flight Center's Solar EUV Rocket Telescope and Spectrograph (SERTS-95) to measure wavelength shifts of coronal emission lines in the core of NOAA active region 7870 relative to its immediate surroundings (its "edge"). This method circumvents the unavailability of reliable laboratory rest wavelengths for the observed lines by using wavelengths from the edge spectrum as references. We derived the, SERTS-95 wavelength calibration from measurements of a post-flight laboratory spectrum containing 28 He II and Ne II EUV standard wavelengths known to high accuracy. Wavelength measurements for lines of He I, Ne III, and additional lines of Ne II in the laboratory calibration spectrum provide more accurate values than were previously available, enabling these lines also to serve as future calibration standards. Six solar lines were chosen for this study, namely, He II at 303.78 A, Fe XII at 193.51 A, Fe XIII at 202.05 A, Fe XIV at 211.33 A, Fe XV at 284.15 A, and Fe XVI at 335.41 A. Because these lines are free from known blends in the SERTS-95 spectra and are either intrinsically strong or near the SERTS-95 peak sensitivity, they are our most reliable lines for measuring relative wavelength shifts in the spatially resolved active region core spectra. The iron ions are the hottest ions ever used for this type of analysis. All six lines reveal statistically significant spatial variations in their measured relative wavelength shifts in the active region core, including mixtures of blueshifts and redshifts (each with maximum values corresponding to relative Doppler velocities approximately 15 km/s), indicating a dynamic, turbulent corona. For each of these lines we calculated weighted-average relative Doppler velocities from the wavelength shifts in the spatially resolved core spectra by weighting the shifts in the individual spatial pixels with their respective measurement uncertainties.

Brosius, Jeffery W.↗

The Geoscience Spaceborne Imaging Spectroscopy Technical Committees Calibration and Validation Workshop

Calibration is the process of quantitatively defining a system's responses to known, controlled signal inputs, and validation is the process of assessing, by independent means, the quality of the data products derived from those system outputs [1]. Similar to other Earth observation (EO) sensors, the calibration and validation of spaceborne imaging spectroscopy sensors is a fundamental underpinning activity. Calibration and validation determine the quality and integrity of the data provided by spaceborne imaging spectroscopy sensors and have enormous downstream impacts on the accuracy and reliability of products generated from these sensors. At least five imaging spectroscopy satellites are planned to be launched within the next five years, with the two most advanced scheduled to be launched in the next two years [2]. The launch of these sensors requires the establishment of suitable, standardized, and harmonized calibration and validation strategies to ensure that high-quality data are acquired and comparable between these sensor systems. Such activities are extremely important for the community of imaging spectroscopy users. Recognizing the need to focus on this underpinning topic, the Geoscience Spaceborne Imaging Spectroscopy (previously, the International Spaceborne Imaging Spectroscopy) Technical Committee launched a calibration and validation initiative at the 2013 International Geoscience and Remote Sensing Symposium (IGARSS) in Melbourne, Australia, and a post-conference activity of a vicarious calibration field trip at Lake Lefroy in Western Australia.

Ong, Cindy↗

Absolute calibration of a hydrogen discharge lamp in the vacuum ultraviolet

A low-pressure hydrogen discharge lamp was calibrated for radiant intensity in the vacuum ultraviolet spectral region on an absolute basis and was employed as a laboratory standard source in spectrograph calibrations. This calibration was accomplished through the use of a standard photodiode detector obtained from the National Bureau of Standards together with onsite measurements of spectral properties of optical components used. The stability of the light source for use in the calibration of vacuum ultraviolet spectrographs and optical systems was investigated and found to be amenable to laboratory applications. The lamp was studied for a range of operating parameters; the results indicate that with appropriate peripheral instrumentation, the light source can be used as a secondary laboratory standard source when operated under preset controlled conditions. Absolute intensity measurements were recorded for the wavelengths 127.7, 158.0, 177.5, and 195.0 nm for a time period of over 1 month, and the measurements were found to be repeatable to within 11 percent.

Nealy, J. E.↗

NPP Clouds and the Earth's Radiant Energy System (CERES) Predicted Sensor Performance Calibration and Preliminary Data Product Performance

Continuation of the Earth Radiation Budget (ERB) Climate Data Record (CDR) has been identified as critical in the 2007 NRC Decadal Survey, the Global Climate Observing System WCRP report, and in an assessment titled Impacts of NPOESS Nunn-McCurdy Certification on Joint NASA-NOAA Climate Goals. In response, NASA, NOAA and NPOESS agreed in early 2008 to fly the final existing CERES Flight Model (FM-5) on the NPP spacecraft for launch in 2010. Future opportunities for ERB CDR continuity consist of procuring an additional CERES Sensor with modest performance upgrades for flight on the NPOESS C1 spacecraft in 2013, followed by a new CERES follow-on sensor for flight in 2018 on the NPOESS C3 spacecraft. While science goals remain unchanged for the long-term ERB Climate Data Record, it is now understood that the task of achieving these goals is more difficult for two reasons. The first is an increased understanding of the dynamics of the Earth/atmosphere system which demonstrates that rigorous separation of natural variability from anthropogenic change on decadal time scales requires higher accuracy and stability than originally envisioned. Secondly, future implementation scenarios involve less redundancy in flight hardware (1 vs. 2 orbits and operational sensors) resulting in higher risk of loss of continuity and reduced number of independent observations to characterize performance of individual sensors. Although EOS CERES CDR's realize a factor of 2 to 4 improvement in accuracy and stability over previous ERBE CDR's, future sensors will require an additional factor of 2 improvement to answer rigorously the science questions moving forward. Modest investments, defined through the CERES Science Team s 30-year operational history of the EOS CERES sensors, in onboard calibration hardware and pre-flight calibration and test program will ensure meeting these goals while reducing costs in re-processing scientific datasets. The CERES FM-5 pre-flight radiometric characterization program benefited from the 30-year operational experience of the CERES EOS sensors, as well as a stronger emphasis of radiometric characterization in the Statement of Work with the sensor provider. Improvements to the pre-flight program included increased spectral, spatial, and temporal sampling under vacuum conditions as well as additional tests to characterize the primary and transfer standards in the calibration facility. Future work will include collaboration with NIST to further enhance the understanding of the radiometric performance of this equipment prior to flight. The current effort summarizes these improvements to the CERES FM-5 pre-flight sensor characterization program, as well as modifications to inflight calibration procedures and operational tasking. In addition, an estimate of the impacts to the system level accuracy and traceability is presented.

Priestly, Kory↗

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

Purpose: To evaluate a prototype densitometer traceable to primary optical standards and compare its performance to an EPSON Expression{sup ®} 10000XL flatbed scanner (the Epson) for quantitative radiochromic film (RCF) dosimetry. Methods: A prototype traceable laser densitometry system (LDS) was developed to mitigate common film scanning artifacts, such as positional scan dependence and high noise in low-dose regions, by performing point-based measurements of RCF suspended in free-space using coherent light. The LDS and the Epson optical absorbance scales were calibrated up to 3 AU, using reference materials calibrated at a primary standards laboratory and a scanner calibration factor (SCF). Calibrated optical density (OD) was determined for 96 Gafchromic{sup ®} EBT3 film segments before and after irradiation to one of 16 dose levels between 0 and 10 Gy, exposed to {sup 60}Co in a polymethyl-methacrylate (PMMA) phantom. The sensitivity was determined at each dose level and at two rotationally orthogonal readout orientations to obtain the sensitometric response of each RCF dosimetry system. LDS rotational scanning dependence was measured at nine angles between 0°and 180°, due to the expected interference between coherent light and polarizing EBT3 material. The response curves were fit to the analytic functions predicted by two physical response models: the two-parameter single-hit model and the four-parameter percolation model. Results: The LDS and the Epson absorbance measurements were linear to primary optical standards to within 0.2% and 0.3% up to 2 and 1 AU, respectively. At higher densities, the LDS had an over-response (2.5% at 3 AU) and the Epson an under-response (3.1% and 9.8% at 2 and 3 AU, respectively). The LDS and the Epson SCF over the applicable range were 0.968% ± 0.2% and 1.561% ± 0.3%, respectively. The positional scan dependence was evaluated on each digitizer and shown to be mitigated on the LDS, as compared to the Epson. Maximum EBT3 rotational dependence was found to have a strong dependence on dose (0.1% and 34% at 30 mGy and 5 Gy, respectively). The preferred EBT3 polymerization axis angle was constant within experimental uncertainties. In its most sensitive orientation, the LDS-measured EBT3 sensitivity was 7.13 × 10{sup −4} ± 9.2 × 10{sup −6} AU/mGy, which represented a 4.5 fold increase over the Epson of 1.58 × 10{sup −4} ± 9.8 × 10{sup −6} AU/mGy. To first order approximations, EBT3 response was linear up to 500 mGy to within 0.80% and to within 7.5% for the most sensitive LDS and the Epson orientations, respectively. The corresponding single-hit and percolation model relative residual norms were 0.082 and 0.074 for LDS as compared to 0.29 and 0.18 for the Epson, which represented a significant increase in LDS-measured agreement with the simple physical model. Less sensitive LDS and the Epson orientations showed a marked decrease in the physical model agreement, which suggested that suboptimal readout device characteristics may be the origin of the complex sensitometric functional forms currently required for accurate RCF dosimetry. Conclusions: The prototype densitometer was shown to be superior to a conventional scanner for quantitative RCF dosimetry based on physical models of film response. The Epson was shown to be a reliable tool for routine RCF dosimetry in a clinical setting, yet calibration to primary optical standards did not mitigate the necessity for complex, empirical functional form fitting.

60 APPLIED LIFE SCIENCES↗

Analysis and Evaluation of NASA's MK40B Six-Component TASK Balance

The paper discusses the physical characteristics NASA's MK40B TASK balance. It is NASA's newest TASK balance that was optimized for the testing of wind tunnel models in the NASA Ames 11-ft Transonic Wind Tunnel. The calibration data of the MK40B balance was obtained in Calspan's Automatic Balance Calibration System. A machine load schedule design was used for the calibration that was developed at the NASA Ames Balance Calibration Laboratory. The calibration data was analyzed using both the Non-Iterative Method and the Iterative Method. Then, the chosen regression models of the calibration data were assessed and compared using the percent contribution, the variance inflation factor, and the calibration load residuals. Interactions of single-component loads were also quantified. In addition, the bi-directional characteristics of the six gage outputs of the balance were assessed by applying a semi-empirical test that was developed at the Ames Balance Calibration Laboratory. It was concluded that four of the six gages of the balance have bi-directional characteristics. Finally, the accuracy of the load prediction equations of the balance was tested by applying the equations to independent check load data that was obtained at the NASA Ames Balance Calibration Laboratory. The standard deviation of the check load residuals met expectations. The check load data also confirmed that the interactions of the forward and aft normal forces on the axial force gage output are very small. - This paper is to be presented in the invited special session titled: "65 Years of TASK Wind Tunnel Balances - Past, Present, and Future".

wind tunnel balance↗

Online, Absolute Quantitation of Propranolol from Spatially Distinct 20- and 40-μm Dissections of Brain, Liver, and Kidney Thin Tissue Sections by Laser Microdissection–Liquid Vortex Capture–Mass Spectrometry

Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20 μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d 7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d 7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

A Gold Standards Approach to Training Instructors to Evaluate Crew Performance

The Advanced Qualification Program requires that airlines evaluate crew performance in Line Oriented Simulation. For this evaluation to be meaningful, instructors must observe relevant crew behaviors and evaluate those behaviors consistently and accurately against standards established by the airline. The airline industry has largely settled on an approach in which instructors evaluate crew performance on a series of event sets, using standardized grade sheets on which behaviors specific to event set are listed. Typically, new instructors are given a class in which they learn to use the grade sheets and practice evaluating crew performance observed on videotapes. These classes emphasize reliability, providing detailed instruction and practice in scoring so that all instructors within a given class will give similar scores to similar performance. This approach has value but also has important limitations; (1) ratings within one class of new instructors may differ from those of other classes; (2) ratings may not be driven primarily by the specific behaviors on which the company wanted the crews to be scored; and (3) ratings may not be calibrated to company standards for level of performance skill required. In this paper we provide a method to extend the existing method of training instructors to address these three limitations. We call this method the "gold standards" approach because it uses ratings from the company's most experienced instructors as the basis for training rater accuracy. This approach ties the training to the specific behaviors on which the experienced instructors based their ratings.

Baker, David P.↗

Precipitation Estimation Using Combined Radar/Radiometer Measurements Within the GPM Framework

The Global Precipitation Measurement (GPM) Mission is an international satellite mission specifically designed to unify and advance precipitation measurements from a constellation of research and operational microwave sensors. The GPM mission centers upon the deployment of a Core Observatory in a 65o non-Sun-synchronous orbit to serve as a physics observatory and a transfer standard for intersatellite calibration of constellation radiometers. The GPM Core Observatory will carry a Ku/Ka-band Dual-frequency Precipitation Radar (DPR) and a conical-scanning multi-channel (10-183 GHz) GPM Microwave Radiometer (GMI). The DPR will be the first dual-frequency radar in space to provide not only measurements of 3-D precipitation structures but also quantitative information on microphysical properties of precipitating particles needed for improving precipitation retrievals from microwave sensors. The DPR and GMI measurements will together provide a database that relates vertical hydrometeor profiles to multi-frequency microwave radiances over a variety of environmental conditions across the globe. This combined database will be used as a common transfer standard for improving the accuracy and consistency of precipitation retrievals from all constellation radiometers. For global coverage, GPM relies on existing satellite programs and new mission opportunities from a consortium of partners through bilateral agreements with either NASA or JAXA. Each constellation member may have its unique scientific or operational objectives but contributes microwave observations to GPM for the generation and dissemination of unified global precipitation data products. In addition to the DPR and GMI on the Core Observatory, the baseline GPM constellation consists of the following sensors: (1) Special Sensor Microwave Imager/Sounder (SSMIS) instruments on the U.S. Defense Meteorological Satellite Program (DMSP) satellites, (2) the Advanced Microwave Scanning Radiometer-2 (AMSR-2) on the GCOM-W1 satellite of JAXA, (3) the Multi-Frequency Microwave Scanning Radiometer (MADRAS) and the multi-channel microwave humidity sounder (SAPHIR) on the French-Indian Megha- Tropiques satellite, (4) the Microwave Humidity Sounder (MHS) on the National Oceanic and Atmospheric Administration (NOAA)-19, (5) MHS instruments on MetOp satellites launched by the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT), (6) the Advanced Technology Microwave Sounder (ATMS) on the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP), and (7) ATMS instruments on the NOAA-NASA Joint Polar Satellite System (JPSS) satellites. Data from Chinese and Russian microwave radiometers may also become available through international collaboration under the auspices of the Committee on Earth Observation Satellites (CEOS) and Group on Earth Observations (GEO). The current generation of global rainfall products combines observations from a network of uncoordinated satellite missions using a variety of merging techniques. GPM will provide next-generation precipitation products characterized by: (1) more accurate instantaneous precipitation estimate (especially for light rain and cold-season solid precipitation), (2) intercalibrated microwave brightness temperatures from constellation radiometers within a consistent framework, and (3) unified precipitation retrievals from constellation radiometers using a common a priori hydrometeor database constrained by combined radar/radiometer measurements provided by the GPM Core Observatory.

Hou, Arthur↗

Pressure-Application Device for Testing Pressure Sensors

A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

Source record↗