Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONNECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

A small protein inhibits proliferating cell nuclear antigen by breaking the DNA clamp

Proliferating cell nuclear antigen (PCNA) forms a trimeric ring that encircles duplex DNA and acts as an anchor for a number of proteins involved in DNA metabolic processes. PCNA has two structurally similar domains (I and II) linked by a long loop (inter-domain connector loop, IDCL) on the outside of each monomer of the trimeric structure that makes up the DNA clamp. All proteins that bind to PCNA do so via a PCNA-interacting peptide (PIP) motif that binds near the IDCL. A small protein, called TIP, binds to PCNA and inhibits PCNA-dependent activities although it does not contain a canonical PIP motif. The X-ray crystal structure of TIP bound to PCNA reveals that TIP binds to the canonical PIP interaction site, but also extends beyond it through a helix that relocates the IDCL. TIP alters the relationship between domains I and II within the PCNA monomer such that the trimeric ring structure is broken, while the individual domains largely retain their native structure. Small angle X-ray scattering (SAXS) confirms the disruption of the PCNA trimer upon addition of the TIP protein in solution and together with the X-ray crystal data, provides a structural basis for the mechanism of PCNA inhibition by TIP.

59 BASIC BIOLOGICAL SCIENCES↗

Fermion WIMPless dark matter at DeepCore and IceCube

We investigate the prospects for indirect detection of fermion WIMPless dark matter at the neutrino telescopes IceCube and DeepCore. The dark matter annihilating in the Sun is a hidden sector Majorana fermion that couples through Yukawa couplings to a connector particle and a visible sector particle, and it exhibits only spin-dependent scattering with nuclei via couplings to first generation quarks. We consider cases where the annihilation products are taus, staus, or sneutrinos of the three generations. To evaluate the muon fluxes incident at the detector, we propagate the neutrino spectra through the solar medium and to the Earth and account for the effects of neutrino oscillations, energy losses due to neutral- and charged-current interactions, and tau regeneration. We find that for the stau and sneutrino channels, a 5 yr 3{sigma} detection of dark matter lighter than about 300 GeV is possible at IceCube for large Yukawa couplings or for dark matter and connector particles with similar masses. The tau channel offers far better detection prospects. However, due to its lower energy threshold and better muon background rejection capability, DeepCore is able to detect signals in all annihilation channels and for a wider range of dark matter masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rice Cellulose SynthaseA8 Plant-Conserved Region Is a Coiled-Coil at the Catalytic Core Entrance

The crystallographic structure of a rice (Oryza sativa) cellulose synthase, OsCesA8, plant-conserved region (P-CR), one of two unique domains in the catalytic domain of plant CesAs, was solved to 2.4 Å resolution. Two antiparallel α-helices form a coiled-coil domain linked by a large extended connector loop containing a conserved trio of aromatic residues. The P-CR structure was fit into a molecular envelope for the P-CR domain derived from small-angle X-ray scattering data. The P-CR structure and molecular envelope, combined with a homology-based chain trace of the CesA8 catalytic core, were modeled into a previously determined CesA8 small-angle X-ray scattering molecular envelope to produce a detailed topological model of the CesA8 catalytic domain. The predicted position for the P-CR domain from the molecular docking models places the P-CR connector loop into a hydrophobic pocket of the catalytic core, with the coiled-coil aligned near the entrance of the substrate UDP-glucose into the active site. In this configuration, the P-CR coiled-coil alone is unlikely to regulate substrate access to the active site, but it could interact with other domains of CesA, accessory proteins, or other CesA catalytic domains to control substrate delivery.

59 BASIC BIOLOGICAL SCIENCES↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Reliability of Open Public Electric Vehicle Direct Current Fast Chargers

The aim was to systematically evaluate the usability of all public electric vehicles (EV) direct current fast chargers (DCFC) in the San Francisco region. To achieve a rapid transition to EVs, a highly reliable and easy to use charging infrastructure is critical to building confidence among consumers. The functionality and usability of all 182 open, public DCFC charging stations with CCS connectors (combined charging system) in the 9 counties of the Bay Area were tested (655 electric vehicle service equipment (EVSE) ports). An EVSE was classified as functional if it charged an EV for 2 minutes. Overall, 73.3% of the 655 EVSEs were functional. The causes of the nonfunctioning EVSEs (23.5%) were blank or unresponsive screens or error messages; payment system failures; charge initiation failures; network failures; or broken connectors. In addition, the cable was too short to reach the EV inlet for 3.2% of the EVSEs. A random sampling of 10% of the EVSEs, approximately 8 days after the first evaluation, found no overall change in functionality. The level of functionality found with field testing conflicts with the 95–98% uptime reported by the EV service providers (EVSPs) who operate the EV charging stations. There is a need for precise and verifiable definitions of uptime, downtime, and excluded time, as applied to public EV chargers. In conclusion, the level of failure of the existing public EV DCFC charge infrastructure highlights the importance of improving the system design and maintenance to improve adoption of EVs.

33 ADVANCED PROPULSION SYSTEMS↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

Assessing the Validity of the Simplified Potential Energy Clock Model for Modeling Glass-Ceramics

Glass-ceramic seals may be the future of hermetic connectors at Sandia National Laboratories. They have been shown capable of surviving higher temperatures and pressures than amorphous glass seals. More advanced finite-element material models are required to enable model-based design and provide evidence that the hermetic connectors can meet design requirements. Glass-ceramics are composite materials with both crystalline and amorphous phases. The latter gives rise to (non-linearly) viscoelastic behavior. Given their complex microstructures, glass-ceramics may be thermorheologically complex, a behavior outside the scope of currently implemented constitutive models at Sandia. However, it was desired to assess if the Simplified Potential Energy Clock (SPEC) model is capable of capturing the material response. Available data for SL 16.8 glass-ceramic was used to calibrate the SPEC model. Model accuracy was assessed by comparing model predictions with shear moduli temperature dependence and high temperature 3-point bend creep data. It is shown that the model can predict the temperature dependence of the shear moduli and 3- point bend creep data. Analysis of the results is presented. Suggestions for future experiments and model development are presented. Though further calibration is likely necessary, SPEC has been shown capable of modeling glass-ceramic behavior in the glass transition region but requires further analysis below the transition region.

36 MATERIALS SCIENCE↗

Validation Assessment of a Glass-to-Metal Seal Finite-Element Model

Sealing glasses are ubiquitous in high pressure and temperature engineering applications, such as hermetic feed-through electrical connectors. A common connector technology are glass-to-metal seals where a metal shell compresses a sealing glass to create a hermetic seal. Though finite-element analysis has been used to understand and design glass-to-metal seals for many years, there has been little validation of these models. An indentation technique was employed to measure the residual stress on the surface of a simple glass-to-metal seal. Recently developed rate- dependent material models of both Schott 8061 and 304L VAR stainless steel have been applied to a finite-element model of the simple glass-to-metal seal. Model predictions of residual stress based on the evolution of material models are shown. These model predictions are compared to measured data. Validity of the finite- element predictions is discussed. It will be shown that the finite-element model of the glass-to-metal seal accurately predicts the mean residual stress in the glass near the glass-to-metal interface and is valid for this quantity of interest.

42 ENGINEERING↗

Revised SNAP III Training Manual

The Shielded Neutron Assay Probe (SNAP) technique was developed to determine the leakage neutron source strength of a radioactive object. The original system consisted of an Eberline TM Mini-scaler and discrete neutron detector. The system was operated by obtaining the count rate with the Eberline TM instrument, determining the absolute efficiency from a graph, and calculating the neutron source strength by hand. In 2003 the SNAP III, shown in Figure 1, was designed and built. It required the operator to position the SNAP, and then measure the source-to-detector and detectorto- reflector distances. Next the operator entered the distance measurements and started the data acquisition. The SNAP acquired the required count rate and then calculated and displayed the leakage neutron source strength (NSS). The original design of the SNAP III is described in SNAP III Training Manual (ER-TRN-PLN-0258, Rev. 0, January 2004, prepared by William Baird) This report describes some changes that have been made to the SNAP III. One important change is the addition of a LEMO connector to provide neutron detection output pulses for input to the MC-15. This feature is useful in active interrogation with a neutron generator because the MC-15 has the capability to only record data when it is not gated off by a pulse from the neutron generator. This avoids recording of a lot of data during the generator pulses that are not useful. Another change was the replacement of the infrared RS-232 serial communication output by a similar output via a 4-pin LEMO connector. The current document includes a more complete explanation of how to estimate the amount of moderation around a neutron-emitting source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Loss Graded Index Polymer Optical Fiber for Local Networking

Here, the objective of this Department of Energy SBIR program has been to develop technology for the advancement of advanced computing systems. NanoSonic worked with two subcontractors, the Polymicro Division of Molex, a U.S.-based manufacturer of specialized optical fiber and fiber components, and Virginia Tech, a research university involved through the Global Environment for Network Innovations (GENI) program in high-speed computer networking research. NanoSonic developed a patented molecular-level self-assembly process to manufacture polymer-based optical fibers in a way similar to the modified chemical vapor deposition (MCVD) approach typically used to make glass optical fibers. Although polymer fiber has a higher attenuation per unit length than glass fiber, short connectorized polymer fiber jumpers offer significant cost savings over their glass counterparts, particularly due to the potential use of low-cost plastic fiber connectors. As part of the SBIR commercialization process, NanoSonic exclusively licensed this technology to a large ($100B+ market cap) U.S.-based manufacturing conglomerate near the end of the first year of the Phase II program. With this base technology developed and licensed, NanoSonic then worked with Polymicro to address secondary program goals of using related but not conflicting production methods to enhance the performance of other specialty optical fiber products and components, and Virginia Tech continued its evaluation of developed polymer fibers in its network infrastructure system on the university campus. We also report our current understanding of the observation during the Phase I program of quantum conductance and partial quantum conductance in metal-insulator-metal (MIM) devices. Such conductance behavior may be modeled as singlemode behavior in one-dimensional electrically conducting waveguides, similar in principle to singlemode optical propagation in dielectric fiber waveguides. Although NanoSonic has not licensed any of the additional technology developed during the second year of the program, several proprietary discussions with major materials companies are underway as of the conclusion of Phase II.

36 MATERIALS SCIENCE↗

Integrated Component-Specific Measurements to Develop Emission Factors for Compressors and Gas Gathering Lines

The Department of Energy (DOE) National Energy Technology Laboratory (NETL) and other critical stakeholders (e.g., U.S. Environmental Protection Agency (USEPA), state regulators, and industry) seek to more accurately characterize and quantify methane emissions from compressors and gathering lines within the Gathering and Boosting (G&B) segment of the natural gas system network. These efforts will reduce uncertainties in emissions estimates in USEPA’s current Green House Gas Inventory (GHGI) under their Greenhouse Gas Reporting Program (GHGRP). For this study, four G&B stations in the Gulf Coast Area were visited four times over the course of one year. Components were classified according to equipment and component type and emissions from select components were measured using multiple measurement technologies. The following major equipment types were considered: i) compressors, ii) separators, iii) dehydrators, iv) coalescers, v) slug catchers, vi) yard piping, vii) tanks, and viii) gathering lines. Individual components on each equipment type were further divided into the following main categories: i) connectors, ii) valves, iii) pressure relief valves (PRV), iv) meters, v) gauges, vi) regulators, vii) pneumatic device vents, and viii) compressor vents (e.g., distance piece vents [DPVs] and rod packing vents [RPVs]). Components were screened for the presence of leaks and venting emissions with an optical gas imaging (OGI) camera, and methane emission rates were measured using a microdilution high volume sampler. Downwind emissions were measured using an Open Path Fourier Transform Infrared (OP-FTIR) Spectrometer. Data were evaluated to assess correlation with site, equipment, time, and operational variables. Key findings and recommendations from the study include: A) Different counting methodologies can result in vastly different component counts, thus influencing total emissions calculations using Subpart W population EFs. A standard methodology should be adopted for classifying and counting components in order to minimize inconsistencies across studies and instruct stakeholders responsible for GHGI reporting. B) Results support current component subcategories listed in USEPA Subpart W, including the subdivision of connectors (flanged and “other”) and pneumatic device vents (intermittent, continuous low bleed, and continuous high bleed). C) Emission rates vary across sites and a relationship between higher emissions and compressor age was observed for some components. D) Component emission rates varied between field campaigns. The type of components contributing to overall measured emissions also varied among field campaigns. However, the emission rate variability was larger between different components (of the same category) than the variability in one component over the four field campaigns. Therefore, when calculating emission factors, it is not necessary to take repeat measurements to capture component variability. E) Measuring the emission rate of a sample for an extended period of time is not necessary to capture the average component emission rate. F) For reporting purposes, excluding liquid lines from site-wide screening may have a negligible effect on component-related emissions. However, from a site management perspective, malfunctioning components were not uncommon on liquid lines and contributed substantially to fugitive emissions at some sites. G) Population EFs, whether including or excluding liquid lines, were a conservative estimate of fugitive emissions. Leaker EFs consistently underestimated emissions at the field sites. Measurements at more sites, particularity sites in other areas of the country, need to be completed before determining the accuracy of EFs.

03 NATURAL GAS↗

20 Channel Quench Detector

A multi-channel quench detector is useful for troubleshooting of prototype HTC superconducting magnets with current lead connections and imbedded splices. There are commercially available quench detectors, but not with as many channels, or with the particular functionality of this unit. This unit was designed specifically for cold testing of a superconducting sextupole prototype, which is wound with many turns of HTC ribbon. Associated with the current lead connections and the imbedded splices are 18 voltage taps, thus 17 quench detection channels are required to monitor the condition of the magnet. Of the 20 differential input channels in this quench detection unit, 19 are configured in a ladder network. The 20th channel is isolated and can be connected across any pair of voltage taps. This quench detector is designed to be used to monitor the condition of a series-connected superconducting magnet powered by a unipolar supply, and therefore the polarity and sequence of the voltage taps must be observed. There are 20 toggle switches and 20 red LEDs on the front panel of the unit which are associated with the 20 quench detection channels. There are also 2 green LEDs to indicate the state of the +5 V and +25 V internal supplies. Channel input impedance is ~10 kΩ. The input lines are diode protected against negative voltage transients and can tolerate up to +25 V, which is greater than the compliance of supplies typically used to power superconducting magnets. The front panel switches are used to enable or disable individual channels. If a channel is not used it is disabled. There are 20 pots on the quench detector PCB. They provide adjustment for the sensitivity of each of the 20 channels. There is an onboard reference to facilitate channel sensitivity calibration. The detection sensitivity range is from ~27 mV to ~700 mV. Typically all channels are set for the same sensitivity. The response time is ~20 μs, but the time constant can be increased if desired by adding a single capacitor to each channel. When the magnet under test is cooled to the superconducting state and the supply current to the windings is slowly ramped up to the set point, if there is a voltage rise across a pair of voltage taps which exceeds the quench detection limit of a given channel, then the front panel LED for that channel illuminates and all other channels are disabled within ~25 ns. Thus only the first quench is detected for the channels which are enabled. A pushbutton switch on the front panel is used to reset a quench detection. A 25 pin D-subminiature connector on the back of the unit is used for the channel inputs. TTL level ‘quench’ and ‘quench-not’ signals, and DPDT relay contacts, are provided through a 9 pin D-subminiature connector on the back to indicate a detected quench condition, which could be used to disable the power supply and engage an energy absorber.

47 OTHER INSTRUMENTATION↗

A Low Cost SIPM Evaluation and Control Prototyping System including accurate bias voltage generation, leakage current measurement, and temperature control using Peltier cooling

We describe an electronics system to operate SIPMs in the laboratory. The system is comprised of a single channel amplifier board (SIPM Amp) and a 4-channel control board to which up to 4 SIPM Amp boards can be connected. The control board supplies a common low voltage power for the amplifiers. All channels feature individually regulated bias and Peltier power voltages, along withPt10K RTD readout. A graphical user interface allows control of the bias voltages, amplifier voltage, Peltier voltages, and also provides for readback of leakage currents and other voltages. The GUI app has a feedback loop to measure the SIPM temperature (with the PT10K) and generate correction voltages to the Peltier to regulate the temperature. The temperatures, which can be achieved by Peltier cooling depend on the thermal design of the setup, the practical limit being about 50C below ambient. The SIPM Amp. board is a small (3x5cm) PCB that has a single SIPM readout channel. The SIPM scan be surface mounted on the pcb or connected to a 2-pin 0.100" socket. The area around the SIPM footprint is thermally isolated by perforations in the PCB. The RTD is located inside the thermal break. Onboard is BV and LV filtering. The 10X amplifier is based on MiniCircuits' GALI-S66+ integrated circuit, tweaked for a 6V power. The amplifier was selected for a combination of high bandwidth, low noise, and low power. An accoupled amplifier output is connected to an SMA connector. For best operation of this inverting amplifier the output signal should be in the range of 0 to -1V.The Amplifier board is connected to the Control board with a 10-conductor 0.025" pitch ribbon cable, carrying all the services. Peltier power for currents more than 1A should use a separate 2-contact connector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RG217 V2-V2 Coaxial Cable Acceptance Test

The ECSE Solid State Pulsed Power unit is a high current, high power solid-state pulse modulator. The RG217 V2-V2 Coaxial Cable Assembly is the interface cable between the Solid State Pulser and the load. This document covers the testing procedure for the RG217 V2-V2 Coaxial Cable Assembly. This assembly is comprised of RG217 Coaxial Cable with a LRU Connector on either end. This test procedure verifies the cable is undamaged and assembled correctly, the correct cable connectors are installed properly onto the cable, and that the entire assembly meets conductivity and holdoff voltage requirements. This procedure will verify that the RG217 Coaxial Cable Assembly meets all assembly and functional requirements. In particular, this procedure verifies the Cable Shield and Center Conductor meet conductivity requirements by testing their resistances. Additionally, this procedure ensures the RG217 Coaxial Cable Assembly meets holdoff voltage requirements by applying high voltage and verifying the RG217 Coaxial Cable Assembly does not experience any breakdowns or arcing.

42 ENGINEERING↗

RG217 V2-V2 Coaxial Cable Assembly Procedure

The ECSE Solid State Pulsed Power unit is a high-current, high power solid-state pulse modulator. The RG217 V2-V2 Coaxial Cable Assembly is the interface cable between the Solid State Pulser and the load. This document covers the assembly procedure for the RG217 V2-V2 Coaxial Cable Assembly. This assembly is comprised of RG217 Coaxial Cable with a LRU Connector on either end. This assembly procedure describes the process used to install cable connectors properly onto the cable.

42 ENGINEERING↗