Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRYOGENIC TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Conceptual Design and Performance Considerations for Superconducting Magnets in the Material Plasma Exposure eXperiment

An important step toward the advent of nuclear fusion as a future power source is the development of plasmafacing materials that can function as designed for a long period of time. While ITER and other devices including Wendelstein 7-X and the Joint European Torus will provide insight into divertor and first wall performance, a dedicated device to advance the understanding of material performance in the representative plasma environments is needed. The Material Plasma Exposure eXperiment has been proposed as a linear plasma device to generate and to direct fusion reactor-like plasma energy and particle flux at the target materials with electron temperatures of 1-15 eV and electron densities of 10 20 -10 21 m -3 . Given that the requirements for radio frequency (RF) heating on-axis field are no greater than 2.5 T and the warm bore diameters must be between 60 cm and 1.5 m, the conceptual design was developed for the experiments on a set of superconducting magnets carried out using commercially available NbTi superconductors. This conceptual design evaluated the cryogenic heat loads, mechanical loads, and quench protection to ensure that the current design is compatible with current technologies. In addition, an alternative evaluation of this design relative to ReBCO high-temperature superconducting magnets determined the conditions under which these technologies could be advantageous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aggregation of One–Dimensional Wires: The Case of Long Oligoynes

We show an unexpected aggregation phenomenon of a long oligoyne (Py[16]) with 16 contiguous triple bonds and endcapped with bulky 3,5-bi(3,5-bis-tert-butylphenyl)pyridine groups. Aggregation of 1D π-conjugated oligoyne chains is rare given the minimal π–π intermolecular interactions as well as its flexibility that works against self-assembly. In dilute solutions, the reversible aggregation of Py[16] initiates at low temperature in the range of 140–180 K, and is not observed for shorter oligoynes in this series. Cryogenic UV/Vis electronic absorption spectra and vibrational Raman spectra with different laser wavelength lines tuning from in-resonance to off-resonance conditions have been used to extract the vibrational features characterizing the monomer and aggregate species. Theoretical calculations complement the spectroscopic findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanical Engineering Safety Note 1012910313-AA: CEA LTIC Structural Integrity

The LRU Target Insert Cryostat (LTIC) is the end effector of the NIF Cryogenic Target Positioner (CryoTarpos), which houses a cooling system to support cryogenic target experiments at NIF. The LTIC maintains a target at micron level positional stability and millikelvin level temperature stability during a NIF shot and is also subject to a portion of the blast load governed by the solid angle subtended by the blast shield at the front of the system. This MESN evaluates loading of the CEA LTIC, a redesigned LTIC to be fielded at Laser Megajoule (LMJ) in France, which has been designed to lay out requirements agreed upon between LLNL and CEA personnel. The LMJ version of CryoTarpos is referred to as the PCC. A high-level system overview of the LTIC on the PCC is shown.

42 ENGINEERING↗

Cryogenic Instrumentation at ProtoDUNE

The cryogenic instrumentation of ProtoDUNE successfully operated during the first run of the experiment, providing a comprehensive monitoring of the cryostats, the cryogenics system and the detectors. It includes devices to measure the liquid argon level, the electron lifetime, the temperature of the liquid and gas argon, the pressure inside the cryostat and the contamination of the gas argon, as well as cameras to inspect the most critical detector elements. These systems and their performance are reviewed, and a few aspects of their future upgrade discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MuFusE large-volume diamond anvil cell for exploring muon-catalyzed fusion at higher pressures and temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion (μCF) Experiment (MuFusE), enabling the compression and heating of deuterium–tritium (d–t) mixtures to pressures and temperatures needed to advance μCF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm 3 at liquid density, pressures up to 933 MPa and temperatures up to 400 K—benchmarks that significantly exceed previously reported limits for static d–t targets.

Kalow, J. D. [Acceleron Fusion, Inc., Cambridge, M↗

Project Report: High Frequency Axion LDRD - A Multiport Approach to Thermal Noise and Scattering Parameter Simulation of Cryogenic Experiments

In this report, a simple algorithm for detailed system-level thermal noise analysis is developed, demonstrated, and verified. This method uses noise-wave theory and noise covariance matrices to cascade noise and scattering parameters of multiport devices at different temperatures. This method addresses the effects of return loss, multiport isolation/coupling, and static temperature differentials between components, and will work in cases where the noise temperature is at or near the quantum noise limit. An ideal multidevice network will first be demonstrated to show that this method’s results are consistent with the Friis cascade when component parameters such as return loss and isolation are ideal. Following the ideal multidevice example, a cryogenic experiment is conducted to demonstrate that the proposed simulation method is successful when real data are used.

42 ENGINEERING↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Uniaxial compression of [001]-oriented CaFe 2 As 2 single crystals:the effects of microstructure and temperature on superelasticity Part I: Experimental observations

Micropillar compression experiments on [001]-oriented CaFe 2 As 2 single crystals have recently revealed the existence of superelasticity with a remarkably high elastic limit of over 10%. The collapsed tetragonal phase transition, which is a uni-axial contraction process in which As-As bonds are formed across an intervening Ca-plane, is the main mechanism of superelasticity. Usually, superelasticity and the related structural transitions are affected strongly by both the microstructure and the temperature. As such, in this study, we investigated how the microstructure and temperature affect the superelasticity of [001]-oriented CaFe 2 As 2 micropillars cut from solution-grown single crystals, by performing a combination of in-situ cryogenic micromechanical testing and transmission electron microscopy studies. Our results show that the microstructure of CaFe 2 As 2 is influenced strongly by the crystal growth conditions and by subsequent heat treatment. The presence of Ca and As vacancies and FeAs nanoprecipitates affect the mechanical behavior significantly. In addition, the onset stress for the collapsed tetragonal transition decreases gradually as the temperature decreases. These experimental results are discussed primarily in terms of the formation of As-As bonds, which is the essential feature of this mechanism for superelasticity. Our research outcomes provide a more fundamental understanding of the superelasticity exhibited by CaFe 2 As 2 under uni-axial compression.

36 MATERIALS SCIENCE↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Self-generated magnetic fields in the hot spot of direct-drive cryogenic implosions at Omega

This work reports that Biermann self-generated magnetic fields of ≈200 MG and Hall parameters of ≈1.5 are produced in the stagnation phase of direct-drive cryogenic implosions at Omega. The magnetic fields produce a drop of 2.4% in fusion yield and 1% in ion temperature. A quantitative estimate of the effect of self-generated magnetic fields on yield and ion temperature is essential, since direct measurements of these fields are not available. Reconstructed simulations of the 50 Gbar implosions, with all the stagnation measurements reproduced simultaneously by a combination of mid- and low-mode asymmetries as degradation mechanisms [Bose et al., Phys. Plasmas 25, 062701 (2018)], are used to obtain the estimates. The magnetic fields cause a decrease in yield due to the Righi–Leduc heat flow, which exceeds any benefits from heat flow suppression due to magnetization. It is important to note that both direct-drive Omega-scale implosions and indirect-drive National Ignition Facility (NIF)-scale implosions [Walsh et al., Phys. Rev. Lett. 118, 155001 (2017)] produce similar estimates for the magnetic field strength, and both show a decrease in fusion yield, with the Righi–Leduc transport as the loss mechanism. However, the yield degradation at Omega is small and lower by ≈5× compared to the indirect-drive ignition-scale NIF estimate.

Physics↗

RHIC Recovery Review Report [See also: RHIC Recovery Review - Hybrid Meeting (11/28/2023) - Indico.bnl.gov]

Just after 12:30 PM on August 1, 2023, the RHIC superconducting magnet quench system triggered and consequently the energy dump resistors were switched into the blue ring quad and dipole circuits and the interaction region DX dipole heaters were switched on. This was a spurious trip (there was no actual quench) and was not unusual as the outdoor summer temperature often caused the quench detectors to cause such trips. The collider control room notified the on-duty cryogenics technical staff of the quench trip. A short time later building 1004B cryogenic low-helium and valve box insulation vacuum failure alarms were observed. The cryogenics technical staff observed the cryo-relief line from the blue ring valve box was exhausting helium outside the building.

43 PARTICLE ACCELERATORS↗

Minimization of thermal deformation in crystal optics for high repetition-rate FEL

Minimizing thermal deformation in X-ray crystal optics is crucial for preserving coherence and wavefront in high-repetition-rate free-electron lasers (FELs). This study presents two approaches to reduce pulse-by-pulse transient thermal deformation in diamond crystals used in cavity-based X-ray FELs (CBXFELs): (1) cryogenic cooling with liquid nitrogen (LN₂), and (2) second-order correction via focusing optics. We revisit the temperature-dependent thermal-mechanical properties of diamond and silicon, implement a finite-element analysis (FEA) method to accelerate convergence to a quasisteady-state regime. Results show that LN₂-cooled diamond crystals meet the stringent deformation requirement of less than 15 pm RMS for the pulse at mJ scale at 1 MHz repetition frequency, and up to 1.5 mJ for 100 kHz. Second-order correction by using focusing elements within the cavity can reduce the impact of thermal deformation for both liquid nitrogen and water cooling.

free electron laser↗

Bound on hot-spot mix in high-velocity, high-adiabat direct-drive cryogenic implosions based on comparison of absolute x-ray and neutron yields

In laser-driven implosions for laboratory fusion, the comparison of hot-spot x-ray yield to neutron production can serve to infer hot-spot mix. For high-performance direct-drive implosions, this ratio depends sensitively on the degree of equilibration between the ion and electron fluids. A scaling for x-ray yield as a function of neutron yield and characteristic ion and electron hot-spot temperatures is developed on the basis of simulations with varying degrees of equilibration. We apply this model to hot-spot x-ray measurements of direct-drive cryogenic implosions typical of the direct-drive designs with best ignition metrics. Furthermore, the comparison of the measured x-ray and neutron yields indicates that hot-spot mix, if present, is below a sensitivity estimated as ~ 2% by-atom mix of ablator plastic into the hot spot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the PIP-II Cryoplant

The Proton Improvement Plan-II (PIP-II) is an essential upgrade to the Fermilab accelerator complex featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac). The Linac contains 23 SRF cryomodules with the SRF cavities operating at 2 K, a high temperature thermal shield at 40 K and low temperature intercepts at 4.5 K. The PIP-II cryoplant will provide the necessary cooling for the cryomodules and the cryogenic distribution system interconnecting cryoplant and cryomodules. This paper describes the evolution of the PIP-II cryoplant conceptual design and specifications, including the expected heat loads, required cooling features and the integrated design. The cryoplant capacity margin analysis and fast cool-down mode will also be discussed.

43 PARTICLE ACCELERATORS↗

Millimeter-Wave Superconducting Qubit

Manipulating the electromagnetic spectrum at the single-photon level is fundamental for quantum experiments. In the visible and infrared ranges, this can be accomplished with atomic quantum emitters, and with superconducting qubits such control is extended to the microwave range (below 10 GHz). Meanwhile, the region between these two energy ranges presents an unexplored opportunity for innovation. We bridge this gap by scaling up a superconducting qubit to the millimeter-wave range (near 100 GHz). Working in this energy range greatly reduces sensitivity to thermal noise compared to microwave devices, enabling operation at significantly higher temperatures, up to 1 K. This has many advantages by removing the dependence on rare 3⁢ He for refrigeration, simplifying cryogenic systems, and providing orders-of-magnitude higher cooling power, lending the flexibility needed for novel quantum sensing and hybrid experiments. Using low-loss niobium trilayer junctions, we realize a qubit at 72 GHz cooled to 0.87 K using only 4 ⁢He. We perform Rabi oscillations to establish control over the qubit state, and measure relaxation and dephasing times of 15.8 and 17.4 ns, respectively. This demonstration of a millimeter-wave quantum emitter offers exciting prospects for enhanced sensitivity thresholds in high-frequency photon detection, provides new options for quantum transduction and for scaling up and speeding up quantum computing, enables integration of quantum systems where 3 ⁢He refrigeration units are impractical, and, importantly, paves the way for quantum experiments exploring a novel energy range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

C1Po2D-04: Cryogenic Testing of the First HL-LHC Q1/Q3 Cryo-Assembly at

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 Cryo-Assembly for the high-luminosity LHC upgrade (HL-LHC). The Cryo-Assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench.

Rabehl, R.↗

Magnetic Avalanche Detector using Single-Molecule Magnets

Here we discuss the results of the 9 month add-on project: “Magnetic Avalanche Detector using Single-Molecule Magnets”. The key point of the projects was to design a cryogenic system that is capable of applying magnetic fields high enough to magnetize the Single-Molecule Magnets (SMMs), maintain temperatures below 1K, and be able to detect magnetic avalanches of the SMM domains. We were able to achieve these goals. Our system was able to magnetize and sense the magnetization of SMM crystals. Moreover, we were able to detect avalanche demagnetization events caused by an alpha particle interacting with a magnetized SMM.

47 OTHER INSTRUMENTATION↗