Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Carbon Capture Plant Front-End Engineering Design Study for Cement Manufacturing

The objective of this project was to conduct a Front-End Engineering Design (FEED) study for capturing carbon dioxide (CO₂) from cement plant flue gas using non-aqueous solvents (NAS) with a 95% capture efficiency. The study aimed to develop AACE (Association for the Advancement of Cost Engineering) Class 3 cost estimates for a commercial-scale CO₂ capture system with a capacity of 2.4 million tonnes of CO₂ per year (t-CO₂/yr). The results will provide Cemex and the U.S. Department of Energy with reliable data to support investment decisions, evaluate economic feasibility, and guide future project development and implementation.

20 FOSSIL-FUELED POWER PLANTS↗

Resource Adequacy and Capital Cost Considerations Pertaining to Large Electric Grids Powered by Wind, Solar, Storage, Gas, and Nuclear

The capacity and generation of wind, solar, storage, nuclear, and gas are estimated for large, idealized copper-plate electric grids. Wind and solar penetrations of 30% to 80% are considered together with different storage systems such as vanadium and lithium-ion batteries, pumped hydroelectric, compressed air, and hydrogen. In addition to a baseline dispatchable fleet without wind/solar, two bounding cases with wind/solar are analyzed: one without storage and one where the whole wind/solar fleet is connected to the storage system, hence providing a buffer between the wind/solar fleet and the grid. The reality will likely be somewhere between these bounding cases. The viability of a power grid with a large wind/solar penetration and no storage is not guaranteed but was nonetheless considered to provide a lower-bound capital cost estimate. Overall, the options that rely strongly on wind, solar, and storage could be significantly more capital-intensive than those that rely strongly on nuclear, depending on the amount of storage necessary to ensure grid stability. This is especially true in the long run because wind, solar, and storage assets have shorter lifetimes than nuclear plants and, consequently, need to be replaced more frequently. More analyses (e.g., grid stability and public acceptance) are necessary to determine which option is most likely to provide the path of least resistance to powering a clean, affordable, and reliable grid in a timely manner. Depending on the priorities, the path of least resistance may not necessarily be the one that is less capital intensive.

adequacy↗

Soil physical and thermal properties from soil samples at multiple locations at Teller Road Site, Seward Peninsula, Alaska, 2019

This dataset contains results of the laboratory analysis of soil samples collected across the watershed located at miles #27 along the Teller road, near Nome, AK. The dataset includes 124 soil samples retrieved from 52 locations during the first week of August 2019. The soil samples were collected in the top 1.2 m of soil with volume known samples, analyzed with a thermal analyser to infer thermal parameters (thermal conductivity, volumetric heat capacity and thermal diffusivity), and then processed in a lab for estimation of their bulk density, water content, carbon and nitrogen content, soil texture, and elemental fractions. This dataset has one csv file and one pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Surface drilling technologies for Mars

We propose rock drilling and coring conceptual designs for the surface activities associated with a manned Mars mission. Straightforward extensions of equipment and procedures used on Earth are envisioned for the sample coring and shallow high explosive shot holes needed for tunneling and seismic surveying. A novel rocket exhaust jet piercing method is proposed for very rapid drilling of shot holes required for explosive excavation of emergency radiation shelters. Summaries of estimated equipment masses and power requirements are provided, and the indicated rotary coring rigs are scaled from terrestrial equipment and use compressed C02 from the Martian atmosphere for core bit cooling and cuttings removal. A mass of 120 kg and power of 3 kW(e) are estimated for a 10 m depth capability. A 100 m depth capacity core rig requires about 1150 kg and 32 kw(e). The rocket exhaust Jet equipment devised for shallow (3m) explosive emplacement shot holes requires no surface power beyond an electrical ignition system, and might have a 15 kg mass.

J D Blacic↗

A satellite system for land-mobile communications in Europe

There exists a great unsatisified demand for land mobile communications in Europe, particularly in sectors of business activity such as the road transport industry. This demand could best be satisfied by means of satellite-based private networks providing voice and data communications in a hub configuration. The potential market is estimated to encompass several hundred thousand road vehicles and the transmission capacity required would be several thousand channels. ESA is currently demonstrating the potential of satellite communications for this type of application, using a system called PRODAT. System studies are being performed with the aim of defining the architecture of a regional satellite system for Europe.

Bartholome, P.↗

Cavity-Dumped Communication Laser Design

Cavity-dumped lasers have significant advantages over more conventional Q-switched lasers for high-rate operation with pulse position modulation communications, including the ability to emit laser pulses at 1- to 10-megahertz rates, with pulse widths of 0.5 to 5 nanoseconds. A major advantage of cavity dumping is the potential to vary the cavity output percentage from pulse to pulse, maintaining the remainder of the energy in reserve for the next pulse. This article presents the results of a simplified cavity-dumped laser model, establishing the requirements for cavity efficiency and projecting the ultimate laser efficiency attainable in normal operation. In addition, a method of reducing or eliminating laser dead time is suggested that could significantly enhance communication capacity. The design of a laboratory demonstration laser is presented with estimates of required cavity efficiency and demonstration potential.

Roberts, W. T.↗

Valuing EV Managed Charging for Bulk Power Systems

When and where electric vehicle (EV) charging occurs has significant implications for power systems supporting widespread EV adoption, especially with high shares of wind and solar generation. This study extends previous works by leveraging detailed simulation models for EV adoption, EV use, EV charging, and bulk power system operations, and by linking them with methods for describing charging flexibility at both the individual vehicle and aggregate levels. This technical potential study focuses on how the value of EV managed charging (EVMC) changes depending on charging flexibility type (within-charging session or within-week scheduling), dispatch mechanism (direct load control or one of several price-based mechanisms), and managed charging participation rate. We show that naively aggregating EV charging flexibility from individual vehicles into megawatt-scale resources grossly overestimates the flexibility of the fleet, because such aggregate models can unrealistically pair, e.g., one already-fully-charged vehicle's ability to increase load with another already-charging vehicle's ability to accept more charge, effectively requesting a charging rate that is infeasible for the latter vehicle. We find per-vehicle bulk system value is highest at low participation rates for all dispatch mechanisms. Factoring in production cost savings, avoided firm capacity savings, and combustion-related power sector emissions savings, we estimate the value of EVMC at low participation rates (5%) to be $33/vehicle-year to $69/vehicle-yr for within-session charging flexibility and $40/vehicle-yr to $120/vehicle-yr for within-week charging flexibility in an envisioned 2038 New England power system and monetary value reported in 2016 U.S. dollars. At 100% participation, per-vehicle value declines to $25/vehicle-yr to $31/vehicle-yr for within-session charging flexibility and to $29/vehicle-yr to $36/vehicle-yr for within-week charging flexibility; however, 100% participation yields the highest total system savings.

ADVANCED PROPULSION SYSTEMS↗

Rooftop Solar Photovoltaic Technical Potential in the United States. A Detailed Assessment

How much energy could be generated if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models--one for small buildings and one for medium and large buildings--and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Rooftop Solar Photovoltaic Technical Potential in the United States

How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Optimal control of systems with capacity: Related noises

In the ordinary theory of optimal control (LQR and Kalman filter), the variances of the actuators and the sensors are assumed to be known (not related to the capacities of the devices). This assumption is not true in practice. Generally, a device with greater capacity to exert actuating forces and a sensor capable of sensing greater sensing range will generate noise of greater power spectral density. When the ordinary theory of optimal control is used to estimate the errors of the outputs in such cases it will lead to faulty results, because the capacities of such devices are unknown before the system is designed. The performance of the system designed by the ordinary theory will not be optimal as the variances of the sensors and the actuators are neither known nor constant. The interaction between the control system and structure could be serious because the ordinary method will lead to greater feedback (Kalman gain) matrices. Methods which can optimize the performance of systems when noises of the actuators and the sensors are related to their capacities are developed. These methods will result in smaller feedback (Kalman gain) matrix.

Ruan, Milfang↗

Thermal properties of simulated Hanford waste glasses

Abstract The Hanford Tank Waste Treatment and Immobilization Plant will vitrify the mixed hazardous wastes generated from 45 years of plutonium production at the Hanford Site in Washington State. The molten glasses will be poured into stainless steel containers or canisters and subsequently cooled for storage and disposal. For appropriate facility design and operations to handle such highly energy‐consuming processes, knowledge of the material properties is required. The thermal properties (heat capacity, thermal diffusivity, and thermal conductivity) of representative high‐level and low‐activity waste glasses were studied as functions of temperature in the range of 200°C‐800°C (relevant to the cooling process). Simultaneous differential scanning calorimetry‐thermal gravimetry (DSC‐TGA), Xe‐flash diffusivity, pycnometry, and dilatometry were implemented. The study showed that simultaneous DSC‐TGA would be a reliable method for obtaining the heat capacity of various glasses in the temperature range of interest. Accurate thermal properties from this study were shown to provide a more realistic guideline for capacity and time constraints of the heat removal process when compared to the original conservative design‐basis engineering estimates. The estimates, though useful for design in the absence of measured physical properties, can now be supplanted and the measured thermal properties can be used in design verification activities.

Rodriguez, Carmen P.↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗

The Behavior of IAPWS-95 from 250 to 300 K and Pressures up to 400 MPa: Evaluation Based on Recently Derived Property Data

Over the past several years, considerable scientific and technical interest has been focused on accurate thermodynamic properties of fluid water covering part of the subcooled (metastable) region and the stable liquid from the melting line up to about 300 K and pressures up to several hundred MPa. Between 2000 and 2010, experimental density data were published whose accuracy was not completely clear. The scientific standard equation of state for fluid water, the IAPWS-95 formulation, was developed on the basis of experimental data for thermodynamic properties that were available by 1995. In this work, it is examined how IAPWS-95 behaves with respect to the experimental data published after 1995. This investigation is carried out for temperatures from 250 to 300 K and pressures up to 400 MPa. The starting point is the assessment of the current data situation. This was mainly performed on the basis of data for the density, expansivity, compressibility, and isobaric heat capacity, which were derived in 2015 from very accurate speed-of-sound data. Apart from experimental data and these derived data, property values calculated from the recently published equation of state for this region of Holten et al. (2014) were also used. As a result, the unclear data situation could be clarified, and uncertainty values could be estimated for the investigated properties. In the region described above, detailed comparisons show that IAPWS-95 is able to represent the latest experimental data for the density, expansivity, compressibility, speed of sound, and isobaric heat capacity to within the uncertainties given in the release on IAPWS-95. Since the release does not contain uncertainty estimates for expansivities and compressibilities, the statement relates to the error propagation of the given uncertainty in density. Due to the lack of experimental data for the isobaric heat capacity for pressures above 100 MPa, no uncertainty estimates are given in the release for this pressure range. Results of the investigation of IAPWS-95 concerning its behavior with regard to the isobaric heat capacity in the high-pressure low-temperature region are also presented. Comparisons with very accurate speed-of-sound data published in 2012 showed that the uncertainty estimates of IAPWS-95 in speed of sound could be decreased for temperatures from 283 to 473 K and pressures up to 400 MPa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Engineering support for magnetohydrodynamic power plant analysis and design studies

The major factors which influence the economic engineering selection of stack inlet temperatures in combined cycle MHD powerplants are identified and the range of suitable stack inlet temperatures under typical operating conditions is indicated. Engineering data and cost estimates are provided for four separately fired high temperature air heater (HTAH) system designs for HTAH system thermal capacity levels of 100, 250, 500 and 1000 MWt. An engineering survey of coal drying and pulverizing equipment for MHD powerplant application is presented as well as capital and operating cost estimates for varying degrees of coal pulverization.

Carlson, A. W.↗

WaterTAP Technical Brief: Ion Exchange Model Demonstration and Optimization

Ion exchange is an important water treatment process for removal of targeted contaminants, including those associated with hardness. In this report, we introduce the ion exchange model developed for WaterTAP and present some example analysis of Ca 2+ removal for 0.1 MGD and 10 MGD systems. The model is a single-component, steady-state implementation that enables process optimization based on the influent ion concentration, resin capacity, and resin selectivity. Based on a survey of costing references for ion exchange, the WaterTAP ion exchange model returns reasonable estimates for the levelized cost of water (LCOW) of an ion exchange process, and performs as expected when critical design parameters, such as the resin capacity and selectivity, are varied.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Potential Pennycress Availability and Suitable Sites for Sustainable Aviation Fuel Refineries in Ohio

Pennycress grain has a relatively high oil content (25–36%) and it is considered a desirable feedstock to produce sustainable aviation fuel (SAF). Pennycress crop can be integrated into the corn–soybean rotation as a winter cover crop in the midwestern U.S. to provide both ecosystem services and economic benefits for the farmers, while serving as a promising feedstock for SAF production. For pennycress-based SAF biorefineries to be established at the commercial scale, a sustainable design of the supply system is required to provide reliable information on feedstock availability and optimal facility locations. The objectives of this research were to assess the pennycress production potential in Ohio, and to identify the best locations to establish the SAF biorefineries. To estimate the pennycress production potential in Ohio, a geographic information system (GIS)-based model was developed using the spatially explicit six-year historical data on areas that were planted in the corn–soybean rotation for the period of 2013 through 2018, pennycress yield estimates from field-based experiments reported in the literature, and the soil productivity index for the region of study. Optimal SAF biorefinery locations were identified using a GIS-based location-allocation model. Annual land potentially available for pennycress production in Ohio was estimated to be ~0.6 million ha, which could produce ~1.1 million metric tons of pennycress grain as feedstock to produce ~210 million liters of SAF, depending on the pennycress yield level, oil content, and conversion efficiencies. In addition, the optimum locations for 12 biorefineries, each at an annual capacity of 18.9 million liters of SAF, were identified, and the average transportation distance was estimated to be 35 and 58 km for maximizing attendance and coverage conditions, respectively. The outcomes of this research would help minimize the risks associated with feedstock supply and cost variabilities for pennycress-based SAF production in the region.

Mousavi-Avval, Seyed Hashem↗

Global crop forecasting

The needs for and remote sensing means of global crop forecasting are discussed, and key results of the Large Area Crop Inventory Experiment (LACIE) are presented. Current crop production estimates provided by foreign countries are shown often to be inadequate, and the basic elements of crop production forecasts are reviewed. The LACIE project is introduced as a proof-of-concept experiment designed to assimilate remote sensing technology, monitor global wheat production, evaluate key technical problems, modify the technique accordingly and demonstrate the feasibility of a global agricultural monitoring system. The global meteorological data, sampling and aggregation techniques, Landsat data analysis procedures and yield forecast procedures used in the experiment are outlined. Accuracy assessment procedures employed to evaluate LACIE technology performance are presented, and improvements in system efficiency and capacity during the three years of operation are pointed out. Results of LACIE estimates of Soviet, U.S. and Canadian wheat production are presented which demonstrate the feasibility and accuracy of the remote-sensing approach for global food and fiber monitoring.

Macdonald, R. B.↗

The Impacts of Demand Response Participation in Capacity Markets

Demand Response is capable of reducing the total amount of generation capacity investment required to ensure electricity system security. We utilise this fact to devise a novel methodology to estimate the contribution of a load-shifting demand response resource to system adequacy. We then simulate an electricity market using mixed complementarity models to determine how the participation of demand response in capacity markets impacts on market outcomes. Demand response primarily affects the equilibrium outcome through the energy market, however demand response also reduces both equilibrium prices and consumer costs through its capacity market contribution. The effect is particularly pronounced when there is a high level of variable renewable generation and initial undercapacity. In the absence of demand response, increased wind generation leads to higher capacity prices as generators seek to offset depressed energy prices. However, we find that demand response's participation in the capacity market can combat these increased capacity prices. These results suggest that demand response participation in capacity markets can mitigate some of the market challenges of renewable integration, particularly that of the 'missing money' problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗