Effect of Various Blade Modifications on Performance of A16-Stage Axial-Flow Compressor. V - Effect on Over-All Performance Characteristics of a 20-Percent Reduction in Solidity of the Fourteenth Through Sixteenth Stage Rotors

The performance of a 16-stage axial-flow compressor, in which the mean-radius solidity was reduced from 1.28 to 1.02 in the fourteenth through sixteenth stage rotors was determined. The performance of this modification was compared with that of the compressor with original rotors. The reduced solidity resulted in slightly improved performance.

Medeiros, Arthur A.↗

Reverse-Tangent Injection in a Centrifugal Compressor

Injection of working fluid into a centrifugal compressor in the reverse tangent direction has been invented as a way of preventing flow instabilities (stall and surge) or restoring stability when stall or surge has already commenced. The invention applies, in particular, to a centrifugal compressor, the diffuser of which contains vanes that divide the flow into channels oriented partly radially and partly tangentially. In reverse-tangent injection, a stream or jet of the working fluid (the fluid that is compressed) is injected into the vaneless annular region between the blades of the impeller and the vanes of the diffuser. As used here, "reverse" signifies that the injected flow opposes (and thereby reduces) the tangential component of the velocity of the impeller discharge. At the same time, the injected jet acts to increase the radial component of the velocity of the impeller discharge.

Skoch, Gary J.↗

Aeroelastic Computations of a Compressor Stage Using the Harmonic Balance Method

The aeroelastic characteristics of a compressor stage were analyzed using a computational fluid dynamic (CFD) solver that uses the harmonic balance method to solve the governing equations. The three dimensional solver models the unsteady flow field due to blade vibration using the Reynolds-Averaged Navier-Stokes equations. The formulation enables the study of the effect of blade row interaction through the inclusion of coupling modes between blade rows. It also enables the study of nonlinear effects of high amplitude blade vibration by the inclusion of higher harmonics of the fundamental blade vibration frequency. In the present work, the solver is applied to study in detail the aeroelastic characteristics of a transonic compressor stage. Various parameters were included in the study: number of coupling modes, blade row axial spacing, and operating speeds. Only the first vibration mode is considered with amplitude of oscillation in the linear range. Both aeroelastic stability (flutter) of rotor blade and unsteady loading on the stator are calculated. The study showed that for the stage considered, the rotor aerodynamic damping is not influenced by the presence of the stator even when the axial spacing is reduced by nearly 25 percent. However, the study showed that blade row interaction effects become important for the unsteady loading on the stator when the axial spacing is reduced by the same amount.

Reddy, T. S. R.↗

Thermal Modeling of a Novel Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC)

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Close-Loop Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising because they are a simple alternative to more mechanically-complex compressors currently used on the ISS. The current investigation addresses the thermal modeling of potential AC-TSAC designs. Design trades include bed geometry (rectangular vs. cylindrical), bed structural material, and configuration of heat pipes within the bed. Also investigated is AC-TSAC performance sensitivity to the thermal conductivity of the adsorbent material and the heat pipes, the input power for heating, and various heat loss mechanisms. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be validated through testing.

Hannah Alpert↗

Thermal Modeling of a Novel Air-Cooled Temperature Swing Adsorption Compressor (AC-TSAC)

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO 2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO 2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. The current investigation addresses the thermal modeling of potential AC-TSAC designs. An initial thermal model was created and validated by comparing the model outputs to experimental data for the heating phase. Several design trades were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), and configuration of heat spreading elements within the bed. Also investigated is AC-TSAC performance sensitivity to the thermal conductivity of the adsorbent material and the heat pipes as well as the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah S. Alpert↗

Thermal Modeling of a Compressor for CO2 Removal in the International Space Station

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah Alpert↗

Thermal Modeling of a Compressor for CO2 Removal in the International Space Station

Contaminant removal technology, such as the Carbon Dioxide Removal Assembly (CDRA) on the International Space Station (ISS), is critical to Environmental Control and Life Support Systems (ECLSS), which enable humans to live and work in outer space. The CDRA includes an adsorbent bed, which absorbs CO2 from the cabin air and releases it to a Sabatier reactor for water production when thermally cycled. An effective system would heat and cool the adsorbent quickly and uniformly to maximize the amount of CO2 removed from the cabin and delivered to the Sabatier reactor. Air-Cooled Temperature Swing Adsorption Compressors (AC-TSAC) are promising for use downstream of the CDRA because they are a simple alternative to more mechanically-complex compressors, which are currently in use on the ISS. A thermal model of the AC-TSAC was created in COMSOL and validated by comparing the model outputs to experimental data for the heating phase of the cycle. Subsequently, several design trades and performance sensitivities were conducted, including bed geometry (rectangular vs. cylindrical), bed structural material (i.e., the material that makes up the walls and shelves), thermal conductivity of the adsorbent material and bed structural materials, and the input power for heating. The results from these studies will inform the design of the next generation of the AC-TSAC, and the thermal modeling results will be further validated through testing.

Hannah Alpert↗

Characterization of the Upgraded NASA GRC Single Stage Axial Compressor and Fan Facility

In order to meet the emissions and efficiency goals established by the aviation community, next generation aircraft engines will require low pressure ratio, distortion tolerant fans. Maturation of the necessary technologies will require facilities which are capable of accurately testing the fan performance. To achieve this, the Single Stage Axial Compressor and Fan facility at NASA Glenn Research Center was upgraded. Details of the goals and upgrades undertaken were documented in the 2022 Turbo Expo paper, “Upgrades to the Single Stage Axial Compressor and Fan Facility for Low Pressure Ratio Boundary Layer Ingesting Fan Research.” The performance of the upgraded facility will be documented in this paper. This paper will review the challenges associated with testing low pressure ratio and distortion tolerant fans and briefly review the upgrades undertaken and their goals. Then the performance of the facility upgrades and the extent to which they were able to achieve the stated goals will be discussed. This includes mass flow measurements, test section temperature, pressure, flow angle at two axial locations, and turbulence levels at the inlet and test section. The paper also documents the performance of distortion generating swirl vanes and total pressure screens to achieve desired distorted conditions at the Aerodynamic Interface Plane.

BLI↗

Characterization of the Upgraded NASA GRC Single Stage Axial Compressor and Fan Facility

In order to meet the emissions and efficiency goals established by the aviation community, next generation aircraft engines will require low pressure ratio, distortion tolerant fans. Maturation of the necessary technologies will require facilities capable of accurately testing the fan performance are needed. To achieve this, the Single Stage Axial Compressor and Fan facility at NASA Glenn Research Center was upgraded. Details of the goals and upgrades undertaken were documented in the 2022 Turbo Expo paper, “Upgrades to the Single Stage Axial Compressor and Fan Facility for Low Pressure Ratio Boundary Layer Ingesting Fan Research.” The performance of the upgraded facility will be documented in this paper. This paper will review the challenges associated with testing low pressure ratio and distortion tolerant fans and briefly review the upgrades undertaken and their goals. Then the performance of the facility upgrades and the extent to which they were able to achieve the stated goals. This includes mass flow measurements, test section temperature, pressure, flow angle at two axial locations, and turbulence levels at the inlet and test section. The paper also documents the performance of distortion generating swirl vanes and total pressure screens to achieve desired distorted conditions at the Aerodynamic Interface Plane.

BLI↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Experimental Investigation of a 16-inch Impulse-type Supersonic-compressor Rotor

Performance data and characteristics of a 16-inch impulse-type supersonic-compressor rotor are presented. The experimental portion of this investigation was conducted in Freon-12. A peak pressure ratio of 3.6 was obtained with an adiabatic efficiency of 0.80 at design conditions. Performance was continuous from impulse operation, at open throttle, to shock-in-rotor operation at the stall condition.

COMPRESSOR FLOW THEORY AND EXPERIMENT↗

Foil Bearing Supported Compressor-Expander

R&D Dynamics Corporation (RDD) is developing a fuel cell system compressor-expander designed for heavy-duty vehicle applications. The system emphasizes high reliability, versatility, long service life, and cost-effective mass production. Its design integrates a high-speed centrifugal compressor/expander, oil-free foil air/gas bearings, a direct current permanent magnet (DCPM) motor, and an inverter utilizing silicon carbide (SiC) switches. Key advantages include high efficiency, compact size and reduced weight, enhanced reliability, and elimination of oil contamination risks. The technology targets multiple sectors such as long-haul semi-trucks, mining and construction equipment, power generation, data centers, marine systems, and other heavy machinery. Evaluation units are ready for shipment, and manufacturing capabilities are currently being developed. Contract Number: DE-EE0009617 (2021).

30 DIRECT ENERGY CONVERSION↗

Methane Mitigation Using Linear Motor Leak Recovery Compressor

GTI Energy (GTI), in collaboration with The University of Texas at Austin - Center for Electromechanics (UT‑CEM), designed, fabricated, and tested a linear motor–driven compressor intended to mitigate methane emissions at natural gas facilities across transmission, storage, gathering, and processing sectors of the gas value chain.

02 PETROLEUM↗