Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contaminated data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Corrective Action Decision Document/Closure Report for Corrective Action Unit 542: Disposal Holes, Nevada Test Site, Nevada, Revision 0, with ROTC 1-2

The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 542 with no further corrective action. To achieve this, corrective action investigation (CAI) activities were performed from July 19 through August 25, 2006, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 542: Disposal Holes. The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: Determine whether contaminants of concern (COCs) are present. If COCs are present, determine the nature and extent. Provide sufficient information and data to complete appropriate corrective actions.

54 ENVIRONMENTAL SCIENCES↗

Combined Contamination and Space Environmental Effects on Solar Cells and Thermal Control Surfaces

For spacecraft in low Earth orbit (LEO), contamination can occur from thruster fuel, sputter contamination products and from products of silicone degradation. This paper describes laboratory testing in which solar cell materials and thermal control surfaces were exposed to simulated spacecraft environmental effects including contamination, atomic oxygen, ultraviolet radiation and thermal cycling. The objective of these experiments was to determine how the interaction of the natural LEO environmental effects with contaminated spacecraft surfaces impacts the performance of these materials. Optical properties of samples were measured and solar cell performance data was obtained. In general, exposure to contamination by thruster fuel resulted in degradation of solar absorptance for fused silica and various thermal control surfaces and degradation of solar cell performance. Fused silica samples which were subsequently exposed to an atomic oxygen/vacuum ultraviolet radiation environment showed reversal of this degradation. These results imply that solar cells and thermal control surfaces which are susceptible to thruster fuel contamination and which also receive atomic oxygen exposure may not undergo significant performance degradation. Materials which were exposed to only vacuum ultraviolet radiation subsequent to contamination showed slight additional degradation in solar absorptance.

Dever, Joyce A.↗

Subspace-based Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing

A subspace-based form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique is based on an eigenvalue decomposition of the background noise cross-spectral matrix. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels, and when background data do not match between measurements. Experimental results show limited success in recovering signal behavior for data in which conventional background subtraction fails. The results also demonstrate the subspace subtraction technique's ability to maintain a physical coherence relationship in the modified cross-spectral matrix. Deconvolution results from microphone phased array data indicate that array integration methods are largely insensitive to subtraction type, and that background subtraction with appropriate background data is an effective alternative to diagonal removal.

deconvolution↗

Clean is not Sterile: A Planetary Science and Planetary Protection Perspective on Cleanroom Microbiology at NASA

The Astromaterials Acquisition and Curation Office at NASA is responsible for the curation of extraterrestrial samples from NASA’s past and future sample return missions. Our office curates samples from the moon, meteorites, comets, asteroids, cosmic dust and solar wind particles. All these samples are kept in cleanrooms to limit particulate and trace metal contamination, but none of these cleanrooms are specifically designed to control microbial contamination. During the early Apollo missions NASA scientists were very concerned with protecting the Earth from potential microbial contamination from the moon and with protecting the lunar samples from terrestrial microbes. NASA developed specialized equipment and clean rooms to keep these collections pristine. However, as we learned more about the lunar environment our concerns about microbial contamination lessened. Today none of the existing collections have microbial contamination requirements because they are not considered susceptible to microbial alteration under curation conditions (e.g. solar wind samples, and lunar samples) or have already been contaminated by terrestrial biology (meteorites collected in Antarctica). However, NASA’s OSIRIS-REx mission will land in 2023 with samples from a carbon rich asteroid that will be susceptible to microbial alteration. The Perseverance rover on Mars will begin to collect and cache samples that will be returned to Earth as soon as 2031. Martian samples may contain signs of extraterrestrial life and will have to be treated like the early Apollo samples. Martian samples will be isolated to protect the Earth, and must also be protected from terrestrial contamination. I will present microbial monitoring data from existing NASA cleanrooms and discuss how NASA is planning to use techniques from the pharmaceutical industry and academia to design new laboratories and equipment that will protect astromaterials and the earth from unwanted microbial contamination. I will also discuss a project to sample the external microbiome of the International Space Station. Results from this research will be used to design facilities for use on Mars that limit the amount of contamination associated with crewed missions.

Aaron B Regberg↗

TIDAL TURBULENCE SPECTRA FROM A COMPLIANT MOORING

A compliant mooring to collect high frequency turbulence data at a tidal energy site is evaluated in a series of short demon- stration deployments. The Tidal Turbulence Mooring (TTM) improves upon recent bottom-mounted approaches by suspend- ing Acoustic Doppler Velocimeters (ADVs) at mid-water depths (which are more relevant to tidal turbines). The ADV turbulence data are superior to Acoustic Doppler Current Profiler (ADCP) data, but are subject to motion contamination when suspended on a mooring in strong currents. In this demonstration, passive stabilization is shown to be sufficient for acquiring bulk statistics of the turbulence, without motion correction. With motion cor- rection (post-processing), data quality is further improved; the relative merits of direct and spectral motion correction are dis- cussed.

ADCP↗

Galaxy Clusters Discovered via the Thermal Sunyaev-Zel’dovich Effect in the 500-square-degree SPTpol Survey

We present a catalog of 689 galaxy cluster candidates detected at significance ξ > 4 via their thermal Sunyaev-Zel’dovich (SZ) effect signature in 95 and 150 GHz data from the 500-square-degree SPTpol survey. We use optical and infrared data from the Dark Energy Camera and the Wide-field Infrared Survey Explorer (WISE) and Spitzer satellites, to confirm 544 of these candidates as clusters with ~ 94% purity. The sample has an approximately redshift-independent mass threshold at redshift z > 0.25. The confirmed sample spans 1.5 × 10 14 < M 500 c < 9 × 10 14 M ⊙ /h 70 and 0.03 < z ≲ 1.6 in mass and redshift, respectively, with a median mass of 2.5×10 14 M ⊙ /h 70 and median redshift z = 0.7; 21% of the confirmed clusters are at z > 1. We use external radio data from the Sydney University Molonglo Sky Survey (SUMSS) to estimate contamination to the SZ signal from synchrotron sources. The contamination reduces the recovered ξ by a median value of 0.032, or ~ 0.8% of the ξ = 4 threshold value, and ~ 7% of candidates have a predicted contamination greater than Δξ = 1. With the exception of a small number of systems (< 1%), an analysis of clusters detected in single-frequency 95 and 150 GHz data shows no significant contamination of the SZ signal by emission from dusty or synchrotron sources. This cluster sample, representing the deepest SZ-selected cluster sample to date, will be a key component in upcoming astrophysical and cosmological analyses of clusters. In addition to the cluster catalog, we also release the millimeter-wave maps and associated data products used to produce this sample. These maps have depths of 5.3 (11.7) µK CMB -arcmin at 150 (95) GHz and an effective angular resolution of 1. '2 (1. '7). The SPTpol products are available at https:// pole.uchicago.edu/public/data/sptpol_500d_clusters/index.html, and the NASA LAMBDA website. An interactive sky server with the SPTpol maps and Dark Energy Survey data release 2 images is also available at NCSA https://skyviewer.ncsa.illinois.edu.

79 ASTRONOMY AND ASTROPHYSICS↗

A Review of the Resuspension of Radioactively Contaminated Particles by Vehicle and Pedestrian Traffic—Current Theory, Practice, Gaps, and Needs

Here, the resuspension of radioactively contaminated particles in a built environment, such as from urban surfaces like foliage, building exteriors, and roadways, is described empirically by current plume and dosimetry models used for hazard assessment and long-term risk purposes. When applying these models to radiological contamination emergencies affecting urban areas, the accuracy of the results for recent contamination deposition is impacted in two main ways. First, the data supporting the underlying resuspension equations was acquired for open, quiescent conditions with no vehicle traffic or human activities, so it is not necessarily representative of the urban environment. Second, mechanical disturbance by winds in urban canyons and during emergency operations caused by vehicle traffic and human activities are not directly considered by the equations. Accordingly, plume and dosimetry models allow the user to input certain compensating values, but the models do not necessarily supply users instructions on what values to use. This manuscript reviews the available literature to comprehensively and consistently pool data for resuspension due to mechanically induced resuspension applicable to urban contamination. Because there are few studies that directly measured radioactive resuspension due to vehicles and pedestrians, this review novelly draws on a range of other studies involving non-radioactive particles, ranging from outdoor air pollution emissions to indoor allergen transport. The results lead to tabulated, recommended values for specific conditions in the emergency phase to help users of plume and dosimetry models maintain the conservativeness needed to properly capture the potential radiation dose posed by mechanically induced resuspension. These values are of benefit to model users until better data are available. The results also suggest the types of data that may result in improved plume and dose modeling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Independent technical review of the building 100 plume, former doe pinellas site (young - rainey star center), largo, florida

Contaminated groundwater associated with Building 100 at the Young-Rainey Science, Technology, and Research Center, formerly the DOE Pinellas plant, is the primary remedial challenge that remains to be addressed at the site. Currently, Building 100 is an active industrial facility that is now owned and operated by the Pinellas county government. Groundwater samples collected from monitoring wells recently installed near the southern boundary of the site suggest that contaminated groundwater has migrated off the plant site. In response to the challenges presented by the Building 100 plume, the Office of Legacy Management (LM) requested assistance from the DOE Office of Groundwater and Soil Remediation (EM-32) to provide a review team to make technical recommendations so that they can efficiently and effectively address characterization and remediation of the plume. The review team was unanimous in the conclusion that a dynamic strategy that combines a phased implementation of direct push samplers, sensors, and tools can be used to better delineate the extent of contamination, control plume migration, and rapidly remediate the contaminated groundwater at the site. The initial efforts of the team focused on reviewing the site history and data, organizing the information into a conceptual model, identifying appropriate technologies, and recommending an integrated strategy. The current groundwater data from the site indicate a two-lobed plume extending to the east and south. To the east vinyl chloride is the primary contaminant of concern, to the south, vinyl chloride and cis1, 2-DCE are the primary contaminants. The limited data that are available suggest that reductive dechlorination of the TCE is already occurring but is not sufficient to prevent offsite migration of low concentrations of TCE daughter products. The team recommends that DOE pursue a strategy that builds on the natural cleansing capacity of the subsurface with reductive methods including biostimulation and/or bioaugmentation to provide a sustainable remediation system within the flow path of the plume. Additional data will be required to implement this approach and will include: (1) Better delineation of the nature and extent of contamination; (2) Demonstration the plume is currently stable or shrinking; and (3) Demonstration the full reductive dechlorination is occurring. The technical team recommends that DOE use a phased approach to identify residual contamination and to provide rapid installation of remedies. Matrices of characterization and remediation sensors, technologies, and tools were developed by the team in order to match the specific conditions and requirements of the site. The team provides a specific example of remedy that includes the incorporation of a dynamic characterization strategy moving from minimally invasive to more aggressive field techniques, the consideration of multiple complementary remediation approaches based on a spatiotemporally phased approach keyed to the different demands of different parts of the plume, and the integration and sequencing of the characterization and remediation activities.

54 ENVIRONMENTAL SCIENCES↗

Analysis Report documenting the Assessment of the Solubility of Lead, EDTA and other Organic Ligands in non-Sulfide systems performed under TP 08-02 and under TP 20-01

The objective of this report is to accept or reject the hypothesis that the experiments conducted under TP 08-02 Revision 0 (Ismail et al., 2008) were affected by CO 2 (g) intrusion and sample contamination. The test of the hypothesis is accomplished by comparing the experimental data collected under the protocols of TP 08-02 Revision O and TP 20-01 Revision O (Kirkes and Zhang, 2020). The protocols of TP 20-01 Revision 0 minimize the possibilities of CO 2 (g) intrusion and sample contamination. The experimental data sets obtained under both TPs will be assessed statistically to see if they are identical or not.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Empirical evidence that mean soil contaminant concentration is not a conservative indicator of external exposure to wildlife

Adequate information on external exposure is often a limiting factor in ecological risk assessments because of a lack of exposure data for free-ranging animals as they interact with a heterogeneous distribution of contaminants. Instead, most wildlife exposure data are estimated from model simulations. However, empirical exposure data are rarely available to verify model results, or to test fundamental assumptions inherent in exposure assessments. We used novel, GPS-coupled radiation dosimeters on reindeer (Rangifer tarandus) to quantify their external exposure for five months in a Chernobyl fallout affected mountainous area of Norway. The exposure data were then used to test a fundamental assumption in screening-level risk assessments: Mean soil contaminant concentrations can be used to conservatively estimate chronic external exposures to representative animals. External exposure and GPS coordinates were obtained hourly and compared to model simulations of exposure based on airborne surveys of 137 Cs soil contamination. Our objectives were to determine 1) if modelled dose estimates based on mean 137 Cs soil concentrations were conservative, and 2) if modelled dose estimates could be improved by adjusting for spatial–temporal heterogeneity of contaminants using 137 Cs concentrations within reindeers’ GPS-defined home ranges and core areas. We found that external exposure modelled from mean soil contaminant concentrations underestimated exposure by 70% compared to empirical measurements from GPS-dosimeter collars worn on individual animals. Using area-weighted mean contaminant levels within the animals’ home range improved the model estimates, but still underestimated the field dosimeter data by 53%. The best estimate of external exposure was obtained when high-use areas within their home range, along with spatial heterogeneity of the contaminant, was accounted for by using area-weighted mean soil contaminant levels within GPS-derived core areas. Accounting for temporal use of core areas within animals’ home range provided a 24% improvement. Here, a comparison of our analyses to similar work performed on Chernobyl wolves found the two studies concur that risk assessors should be cautious in relying on the paradigm of using averaged soil contaminant levels to provide conservative estimates of external exposure to representative individuals. Results of modelled external exposure based on mean soil contaminant concentrations could misguide assessors and cause inappropriate management decisions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Annual report of monitoring at Morrill, Kansas, in 2010.

Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha. The population of Morrill as of the 2000 census was approximately 277. All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991. Starting in 1922, eight different public wells formerly served the Morrill municipal system at some time. Because of poor water quality, including high nitrate levels attributed to numerous animal feeding operations in the vicinity and application of fertilizer on agricultural lands, use of the local groundwater from any public well for municipal supply purposes was terminated in 1991 in favor of obtaining water from the Sabetha municipal water system. Investigations of the carbon tetrachloride and nitrate contamination by the Kansas Department of Health and Environment (KDHE) in 1989, 1994, and 1996 (KDHE 1989; GeoCore 1994a-e, 1996) identified a localized plume of carbon tetrachloride in groundwater extending downgradient from a grain storage facility located in the northwestern section of Morrill. The facility was formerly operated by the Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), from 1950 to 1971. Since termination of the CCC/USDA grain storage operations in 1971, the property and existing grain bins have been used for private grain storage up to the present time. Prior to 1986, commercial grain fumigants were commonly used by the CCC/USDA, as well as private and commercial grain storage operations, to preserve grain. Because the identified carbon tetrachloride contamination could in part be linked to historical use of carbon tetrachloride-based fumigants at its former facility, in 2003 the CCC/USDA assumed responsibility for the site investigation of the carbon tetrachloride contamination. The CCC/USDA involvement began with development and implementation of a work plan for a Phase I expedited site characterization (Argonne 2003). That investigation and subsequent investigations (Argonne 2004, 2005a) were performed by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne continues to provide technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. The initial investigation by the CCC/USDA in 2003 determined that soils at the former facility have not been impacted by grain fumigation activities. Neither carbon tetrachloride nor chloroform was detected in near-surface soils or in subsurface soils collected to bedrock or to a depth of 15 ft below ground level (BGL). Therefore, no identifiable human health risk is associated with either carbon tetrachloride or chloroform in shallow soils, which additionally pose no further threat of contamination to groundwater. High carbon tetrachloride concentrations in groundwater (maximum 390 {micro}g/L in a sample collected from monitoring well MW3S - located on the former CCC/USDA property - in 1995) have declined significantly during long-term monitoring by the KDHE and currently by the CCC/USDA. Maximum levels within the plume of < 50 {micro}g/L at present confirm that no continuing soil source remains at the former CCC/USDA facility. Nevertheless, carbon tetrachloride concentrations exceeding the KDHE Tier 2 risk-based screening level of 5.0 {micro}g/L remain. In September 2005, the CCC/USDA initiated periodic sampling of groundwater at Morrill, in accord with a monitoring program approved by the state (KDHE 2005), to monitor carbon tetrachloride concentrations in the groundwater. Under the KDHE-approved monitoring plan (Argonne 2005b), groundwater was initially sampled twice yearly for a period of two years. The samples were analyzed for VOCs, as well as for selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. The data have been inconclusive overall, possibly because of the relatively low contaminant concentrations in the plume. Nevertheless, consistently low levels of dissolved oxygen (DO) and oxidation-reduction potential (ORP) at monitoring well MW1D (in the deepest portion of the contaminated aquifer) and the presence of chloroform (the primary degradation product of carbon tetrachloride) suggest that some degree of reductive dechlorination is occurring.

54 ENVIRONMENTAL SCIENCES↗

A Multiple Lines of Evidence Approach for Conceptual Site Models in Performance Assessments - 19070

Demonstration of the long-term performance of remediated radioactive waste sites relies on models that evaluate vadose zone and groundwater flow and contaminant transport for thousands of years. Model qualification, verification, and comparisons with data are essential elements to demonstrating the accuracy of long-term performance assessments (PAs). However, comparisons with data are generally limited due to incomplete characterization data and long-time scales. Since PAs support decision making to assure long-term protection of both human health and the environment, a conceptual site model (CSM) is needed to explain the hydrodynamic behavior and account for subsurface heterogeneities in sufficient detail to support confident decisions. In the case of the Waste Management Area (WMA) C PA, where the focus of the effort is on characterizing flow and transport through a thick vadose zone, site-specific data are sparse and larger-scale geologic descriptions are adopted with the risk of losing small scale features that may affect contaminant transport. Features such as horizontal bedding and sloping interfaces between contrasting material types, as well as vertically oriented features such as clastic dikes, may be difficult to delineate from sparse characterization data, but may affect the extent to which contaminants are transported. The PA conducted to identify long-term impacts associated with the closure of the single-shell tank (SST) farm at WMA C adopted an equivalent homogenous medium approach to represent the major stratigraphic units at the site. This approach explicitly represents major stratigraphic units but assigns hydraulic properties that implicitly account for the presence of small-scale heterogeneities and their impact on flow and contaminant transport to the groundwater. The objective of this study is to evaluate the available site-specific and analogue data that can be used to characterize heterogeneity and to assess its impact on fate and transport of contaminants that may lead to different conclusions when compared to the results of the equivalent homogeneous media approach. To this end, a multiple lines of evidence approach was used to construct alternative CSMs based on an evaluation of several types of data. These data include 1) general characteristics and features of the major stratigraphic units from historical descriptions; 2) borehole geologic logs; 3) particle size distribution measurements; 4) moisture content measurements; 5) spectral gamma data; and 6) concentrations of key constituents (i.e., Tc-99) in both the vadose zone and groundwater impacted by past releases. Based on an analysis of the available data, lines of evidence are evaluated for consistency and integrated in a consistent manner into scientifically defensible CSMs. Numerical models are then used to evaluate the impact that the explicit representation of heterogeneities has on contaminant transport. Together, the field data and the numerical modeling results indicate that heterogeneity caused by the small-scale features do not have a significant (i.e. greater than a factor of 2) impact on transport below WMA C relative to peak concentrations and arrival times for potential releases from waste tanks. The results of this study underscore the value of using multiple lines of evidence based on the quantity and quality of available data in developing alternative CSMs and evaluating their relative impact on key transport metrics such as arrival times and peak concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contaminant Release from Residual Waste in Closed Single-Shell Tanks and Other Waste Forms Associated with the Tanks

This chapter describes the release of contaminants from the various waste forms that are anticipated to be associated with closure of the single-shell tanks. These waste forms include residual sludge or saltcake that will remain in the tanks after waste retrieval. Other waste forms include engineered glass and cementitious materials as well as contaminated soil impacted by previous tank leaks. This chapter also describes laboratory testing to quantify contaminant release and how the release data are used in performance/risk assessments for the tank waste management units and the onsite waste disposal facilities. The chapter ends with a discussion of the surprises and lessons learned to date from the testing of waste materials and the development of contaminant release models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of initial-data uncertainty on a shock-accelerated gas cylinder

We quantify initial-data uncertainties on a shock accelerated heavy-gas cylinder by two-dimensional well-resolved direct numerical simulations. A high-resolution compressible multicomponent flow simulation model is coupled with a polynomial chaos expansion to propagate the initial-data uncertainties to the output quantities of interest. The initial flow configuration follows previous experimental and numerical works of the shock accelerated heavy-gas cylinder. We investigate three main initial-data uncertainties, (i) shock Mach number, (ii) contamination of SF{sub 6} with acetone, and (iii) initial deviations of the heavy-gas region from a perfect cylindrical shape. The impact of initial-data uncertainties on the mixing process is examined. The results suggest that the mixing process is highly sensitive to input variations of shock Mach number and acetone contamination. Additionally, our results indicate that the measured shock Mach number in the experiment of Tomkins et al. [“An experimental investigation of mixing mechanisms in shock-accelerated flow,” J. Fluid. Mech. 611, 131 (2008)] and the estimated contamination of the SF{sub 6} region with acetone [S. K. Shankar, S. Kawai, and S. K. Lele, “Two-dimensional viscous flow simulation of a shock accelerated heavy gas cylinder,” Phys. Fluids 23, 024102 (2011)] exhibit deviations from those that lead to best agreement between our simulations and the experiment in terms of overall flow evolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary study of contaminant particulates around Skylab

Techniques originally developed for the Skylab T025 contamination experiment were applied to S052 white-light coronagraph data in a preliminary study to investigate particulates around Skylab. Periods were selected which contained some contamination, even though there were no apparent dumps or vents during these periods. Velocity and size distributions were determined from optical data for particles within 200 meters of the spacecraft. Both photographic (61 particle tracks) and video (34 particles) observations yield an upper limit on particle radius of 100 micrometers. Selected photometric data from the S073 zodiacal light experiment during mission SL-2 were also examined for evidence of contamination.

Schuerman, D. W.↗

Shuttle on-orbit contamination and environmental effects

Ensuring the compatibility of the space shuttle system with payloads and payload measurements is discussed. An extensive set of quantitative requirements and goals was developed and implemented by the space shuttle program management. The performance of the Shuttle system as measured by these requirements and goals was assessed partly through the use of the induced environment contamination monitor on Shuttle flights 2, 3, and 4. Contamination levels are low and generally within the requirements and goals established. Additional data from near-term payloads and already planned contamination measurements will complete the environment definition and allow for the development of contamination avoidance procedures as necessary for any payload.

Leger, L. J.↗

CMB lensing and Ly⁢ α forest cross bispectrum from DESI’s first-year quasar sample

The squeezed cross-bispectrum B κ,Ly α between the gravitational lensing in the cosmic microwave background and the 1D Ly α forest power spectrum can constrain bias parameters and break degeneracies between σ8 and other cosmological parameters. We detect B κ,Ly ⁢α with 4.8⁢σ significance at an effective redshift z eff =2.4 using Planck PR3 lensing map and over 280,000 quasar spectra from the Dark Energy Spectroscopic Instrument’s first-year data. We test our measurement against metal contamination and foregrounds such as Galactic extinction and clusters of galaxies by deprojecting the thermal Sunyaev-Zeldovich effect. Finally, we compare our results to a tree-level perturbation theory calculation and find reasonable agreement between the model and measurement.

79 ASTRONOMY AND ASTROPHYSICS↗