Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contingency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis

Here, this study performs a techno-economic analysis of hydrogen underground storage systems for grid electricity storage, evaluating their economic viability at the plant scale using dynamic optimization. It explores the feasibility of various system configurations and revenue models in the context of volatile electricity prices and the necessity for multiple revenue streams. The hypothesis tested is that large-scale hydrogen storage, despite its low round-trip efficiency, can be economically viable with the right mix of revenue streams. This study uses scenario-based analysis to assess the impacts of different system configurations, including engaging in time-shifting arbitrage, ancillary service markets and blending hydrogen with natural gas. Results indicate potential annual net cash flows of up to $\$$1.5 million from ancillary services integration and $\$$5.2 million from natural gas blending, contingent on specific system sizes. The study concludes that hydrogen underground storage for grid electricity storage can be profitable, and emphasizes that proper system design and precise electricity price forecasting are crucial for optimizing system performance and economic returns. This research sets the stage for further investigations into the scalability of hydrogen storage systems and their broader implications for grid electricity storage and energy market dynamics.

25 ENERGY STORAGE↗

U.S. domestic cats as sentinels for perfluoroalkyl substances: Possible linkages with housing, obesity, and disease

Perfluoroalkyl substances (PFAS), such as perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA), are persistent, globally distributed, anthropogenic compounds. The primary source(s) for human exposure are not well understood although within home exposure is likely important since many consumer products have been treated with different PFAS, and people spend much of their lives indoors. Herein, domestic cats were used as sentinels to investigate potential exposure and health linkages. PFAS in serum samples of 72 pet and feral cats, including 11 healthy and 61 with one or more primary disease diagnoses, were quantitated using high-resolution time-of-flight mass spectroscopy. All but one sample had detectable PFAS, with PFOS and perfluorohexane sulfonate (PFHxS) ranging from <LOQ to 121 and <LOQ to 235 ng/mL, respectively. PFAS prevalence and geometric means in cats were very similar to contemporary NHANES reports of human sera in the U. S. population. The highest PFAS serum concentrations detected were in indoor cats due to disproportionately elevated PFHxS levels. Ranked by quartile, contingency testing indicated that total PFAS levels were positively associated with living indoors and with higher body weight and body condition scores. Individual PFAS quartile rankings suggested positive associations with respiratory effusion, thyroid, liver, and possibly chronic kidney disease. Domestic cats appear to be useful sentinels for assessing primary PFAS exposure routes, especially indoor sources of relevance to children. Additional case-control studies in pet cats are warranted to better define the potential health associations observed herein. A “One Health” approach assessing humans, pets, and their common environment may improve our understanding of chronic low-level, largely indoor, PFAS exposure and effects in humans and animals alike. - Highlights: • PFAS serum concentrations were measured in healthy and diseased U. S. domestic cats. • Most abundant were PFOS (range < LOQ to 121) and PFHxS (< LOQ to 235 ng/mL). • PFAS geometric means were very similar to that reported in U.S. human sera by NHANES. • Higher ΣPFAS levels were positively associated with living indoors and with obesity. • Associations with lung, liver, thyroid, or kidney disease may guide future studies.

54 ENVIRONMENTAL SCIENCES↗

Using landscape typologies to model socioecological systems: Application to agriculture of the United States Gulf Coast

Agricultural enterprises are vulnerable to the effects of climate variability and change. Improved understanding of the determinants of vulnerability and adaptive capacity in agricultural systems is important for projecting and managing future climate risk. At present, three analytical tools dominate methodological approaches to understanding agroecological vulnerability to climate: process-based crop models, empirical crop models, and integrated assessment models. A common weakness of these approaches is their limited treatment of socio-economic conditions and human agency in modeling agroecological processes and outcomes. This study proposes a framework that uses spatial cluster analysis to generate regional socioecological typologies that capture geographic variance in regional agricultural production and enable attribution of that variance to climatic, topographic, edaphic, and socioeconomic components. This framework was applied to historical corn production (1986-2010) in the U.S. Gulf of Mexico region as a testbed. The results demonstrate that regional socioeconomic heterogeneity is an important driving force in human dominated ecosystems, which we hypothesize, is a function of the link between socioeconomic conditions and the adaptive capacity of agricultural systems. Meaningful representation of future agricultural responses to climate variability and change is contingent upon understanding interactions among biophysical conditions, socioeconomic conditions, and human agency their incorporation in predictive models.

58 GEOSCIENCES↗

A two-phase investment model for optimal allocation of phasor measurement units considering transmission switching

Ensuring the reliability of an electrical power system requires a wide-area monitoring and full observability of the state variables. Phasor measurement units (PMUs) collect in real time synchronized phasors of voltages and currents which are used for the observability of the power grid. Due to the considerable cost of installing PMUs, it is not possible to equip all buses with PMUs. In this paper, we propose an integer linear programming model to determine the optimal PMU placement plan in two investment phases. In the first phase, PMUs are installed to achieve full observability of the power grid whereas additional PMUs are installed in the second phase to guarantee the N - 1 observability of the power grid. The proposed model also accounts for transmission switching and single contingencies such as failure of a PMU or a transmission line. Results are provided on several IEEE test systems which show that our proposed approach is a promising enhancement to the methods available for the optimal placement of PMUs.

Phasor measurement unit↗

Toward a scalable robust security-constrained optimal power flow using a proximal projection bundle method

Robust security-constrained optimal power flow (rSCOPF) aims to find the worst-case contingencies of alternating current optimal power flow (ACOPF) in power systems. With the rise of GPU architectures on the upcoming supercomputer architectures, optimization algorithms that rely on sparse linear algebra and indefinite linear systems are becoming increasingly hard to solve efficiently (e.g. interior-point method). To address this we revisit a maximin optimization formulation of the rSCOPF and the single-level mixed-integer semidefinite programming (MISDP) reformulation, which is obtained by taking the Lagrangian relaxation of the inner minimization ACOPF problem. In this paper, we focus on the development of a proximal projection bundle method (PPBM) for solving continuous relaxation node subproblems of the MISDP problem, based primarily on the well-known alternating direction method of multipliers. Cutting planes reminiscent of bundle method ideas are also applied in coordination with updates of the proximal parameter. The cutting-plane method can generate a large number of linear inequalities, leading to a large scale but decomposable quadratic programming (QP) subproblem that is amenable to GPUs. We present the numerical results on the IEEE 30, 57, 118, and 300-bus systems by using our PBMM method. We discuss the main computational bottleneck of our method, which is the time taken to solve each iteration of a QP subproblem instance of the PPBM, and how GPU architectures can accelerate this solution process.

bundle method↗

DINGO: Digital assistant to grid operators for resilience management of power distribution system

With increasing adverse weather events and disasters, enabling resiliency of the power distribution system (PDS) is becoming increasingly important. Here in this work, resiliency is defined as the systems ability to keep supplying critical loads even with multiple contingencies. Resiliency may depend on: (a) advanced tools to assist operators in situational awareness and decision making with the increasing volume of data generated by the PDS, (b) visualization and ease of interaction with system resources and information, especially during extreme events and resulting human operator stress, and (c) flexible resources and autonomous control. Operators and support engineers need to interact with the system for key information and take action under stress, given the requirement for decisions in a short time. Integrated technological solutions are prevailing steps to support the most appropriate decision during critical times to serve essential loads. In order to meet the required goals, a Real-time Resiliency Monitoring and Operational Decision Support (RT-RMOD) tool have been developed. It supports various functionalities, including real-time monitoring, resilience assessment, and proactive decision support. However, this work makes advanced feature additions to the tool by developing data-enabled resilience management algorithms for (i) outage detection and localization, (ii) Resiliency-metric driven restoration and reconfiguration, and (iii) NLP based digital assistant for operators called DINGO (DIgital assistaNt to Grid Operators) to interact with Advanced Distribution Management System (ADMS) and RT-RMOD. The developed algorithm was validated for multiple cases of weather events using a real-world, off-grid microgrid system modeled in a real-time simulator, sensor data, and software tools.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Off-policy deep reinforcement learning with automatic entropy adjustment for adaptive online grid emergency control

Electric overloading conditions and contingencies put modern power systems at risk of voltage collapse and blackouts. Load shedding is crucial to maintain voltage stability for grid emergency control. However, the rule- or model-based schemes rely on accurate dynamic system models and face considerable challenges in adapting to various operating conditions and uncertain event occurrences. Here, to address these issues, this paper proposes a novel deep reinforcement learning (DRL)-based voltage stability control algorithm with automatic entropy adjustment (AEA) for grid emergency control. Various dynamic network components for complex system operations are modeled to construct the DRL environment. An off-policy soft actor-critic architecture is developed to maximize the expected reward and policy entropy simultaneously. The AEA mechanism is proposed to facilitate the policy maximum entropy procedure, and the proposed method can automatically provide effective discrete and continuous actions against various fault scenarios. Our approach accomplishes high sampling efficiency, scalability, and auto-adaptivity of the control policies under high uncertainties. Comparative studies with the existing DRL-based control methods in IEEE benchmarks indicate salient performance improvement of the proposed method for dynamic system emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning model combining convolutional deep neural network with a self-attention mechanism for AC optimal power flow

Alternating current optimal power flow (OPF) analysis is critical for efficient and reliable operation of power systems. For large systems or repetitive computations, the traditional methods such as the direct and gradient methods, or non-traditional methods, such as the genetic algorithm and simulating annealing, are time-consuming and unsuitable for real-time computing. The work in this paper proposes a novel framework to obtain the optimal solution of power flow in real-time using a combination of convolutional neural networks and a self-attention mechanism. All parameters of the power networks are rearranged in an image-like shape of a multi-channel image where each channel is a two-dimensional matrix. The proposed approach is adaptive with every input size of power systems as well as frequent variations of network topologies without intervention to the framework core. The encompassment of all power system contexts in which all parameters of internal elements, generation costs, and topology information are included, contributes to the higher accuracy of inference compared to other current machine-learning-based OPF-solving methods. Besides, the proposed framework established on ubiquitous platforms is effortlessly integrated into current infrastructures of power systems, and the great efficiency along with the computation speed may serve as a critical point for practical implications, such as enabling faster decision-making during real-time operations, predicting system contingencies, and remedial actions based on an offline pre-trained model. Furthermore, this supervised learning process is applied to the dataset of four case studies of meshed power systems: the IEEE 5-bus system (IEEE-5), the IEEE 30-bus system (IEEE-30), the IEEE 39-bus system (IEEE-39), and the IEEE 57-bus system (IEEE-57) to prove the efficacy of the proposed method.

42 ENGINEERING↗

Integrating solar energy with agriculture: Industry perspectives on the market, community, and socio-political dimensions of agrivoltaics

Large-scale development of solar-generated electricity is hindered in some regions of the U.S. by land use competition and localized social resistance. One approach to alleviate these coupled challenges is agrivoltaics: the strategic co-location of solar photovoltaics and agriculture. To explore the opportunities and barriers for agrivoltaics, in-depth interviews with solar industry professionals were conducted and findings suggest that the potential for an agrivoltaic project to retain agricultural interests and consequently increase local support for development is the most significant opportunity of dual use solar. Capable of increasing community acceptance, participants expect agrivoltaics to play an important role in future solar endeavors, especially in places where development may be perceived as a threat to agricultural interests. The results further reveal the interconnections among the various dimensions of social acceptance and suggest that the growth of agrivoltaics is contingent on market adoption of the technology through community acceptance and supportive local regulatory environments. As solar photovoltaic systems transcend niche applications to become larger and more prevalent, the dimensions of social acceptance, including the opportunities and barriers associated with each dimension, can help inform decision making to enhance the growth of agrivoltaics and thus photovoltaic development. Here, the findings can help land use planners, solar developers, and municipal governments make informed decisions that strategically and meaningfully integrate agriculture and solar, and in turn provide multiple benefits including the retention of agricultural land, local economic development, and broad adoption of solar energy technologies.

14 SOLAR ENERGY↗

Assessing the levelized cost of energy in South Korea

This study evaluates the levelized cost of energy (LCOE) for various energy technologies in the Republic of Korea (Korea) from 2023 to 2050, highlighting cost trajectories and potential crossovers among competing technologies. The analysis projects that, based on our set of assumptions, utility-scale photovoltaic systems achieve lower LCOEs than nuclear by 2030, while fixed offshore wind is expected to become cost-competitive with coal-fired generation around the same time. Floating offshore wind is projected to reach cost parity with coal in the late 2030s. Co-firing with natural gas and green hydrogen is identified as the highest-cost generation option due to high natural gas and green fuel costs and declining capacity utilization. This study further examines the potential for hybrid systems that integrate renewable energy with energy storage to serve as flexible, cost-effective, zero-emission alternatives to green hydrogen-based generation. Spatial LCOE assessments indicate that near-shore offshore wind sites may achieve lower costs despite modest capacity factors, contingent on site-specific factors such as grid integration and social acceptance. The findings indicate that renewable energy technologies are expected to experience continued cost declines, with solar photovoltaic becoming the most competitive energy source in Korea by 2030–2035. Incorporating social costs accelerates this shift from conventional alternatives.

Green hydrogen↗

Influence of microstructure on replacement and porosity generation during experimental dolomitization of limestones

Replacement reactions commonly alter the multiscale pore structures of rocks during fluid-rock interactions. Analysis of these processes in various model fluid-rock systems during controlled laboratory experiments provides insights into the origins of microstructures found in natural materials. This study focused on understanding the effects of initial starting material permeability and resultant differences in transport pathways on porosity and mineralogical changes during limestone dolomitization.A series of replacement experiments (32–317 days in duration) have been conducted in which 1.59 cm (5/8 in.) diameter cores of two different limestones were reacted with saturated MgCl2 solutions at 200 °C. The Texas Cream (Austin Chalk) is a high-porosity, high-permeability limestone, whereas both the porosity and permeability of the Carthage Marble (Burlington Limestone) are relatively low. Altered limestones were imaged using scanning electron microscopy with energy-dispersive X-ray spectroscopy (SEM-EDX), Time-of-Flight Secondary Ion Mass Spectrometry (ToF–SIMS) and electron microprobe analysis (EMPA). A representative grain boundary of the low-porosity limestone was targeted for a focused ion beam (FIB) lift-out and characterized using transmission electron microscopy (TEM). These results were coupled with analyses of radial changes in the porosity distribution of the core derived from X-ray and neutron small- and ultra-small angle scattering ((U)SANS/(U)SAXS).The high-porosity/permeability limestone showed a four times faster bulk replacement rate than the lower-porosity/permeability material, and a different mechanism of porosity development. For the low-porosity limestone, a two-stage replacement occurred, with the reacted region of the core consisting of an inner rim in which the limestone was replaced by two calcite-dolomite solid solutions, and an outer rim in which the dolomite was replaced by magnesite. Elongated pores formed along grain boundaries at the initial limestone/dolomite reaction interface, and additional nanometer-scale porosity was formed at the secondary magnesite replacement rim. Grain boundaries were identified as preferential pathways for transport leading to dolomitization and a grain boundary diffusion rate was calculated based on microstructural characterization. In contrast, replacement in the high-porosity limestone was accompanied by porosity generation through replacement of individual grains by dolomite throughout the sample and, in longer runs, magnesite in outer parts of the core. These observations emphasize that both the mechanisms of the replacement reaction and the microstructure and chemistry of the replaced product are contingent on the initial structure of the starting material.

36 MATERIALS SCIENCE↗

Post-extreme-event restoration using linear topological constraints and DER scheduling to enhance distribution system resilience

In this paper, a post-extreme-event restoration (PEER) algorithm is proposed to improve distribution system resilience. Linear topological constraints are proposed to ensure radial topology after N-k contingencies, possibly in multiple islands. The approach is made comprehensive by considering dispatchable distributed energy resources (DERs), non-dispatchable DERs, and demand responses, as well as on-load tap changers (OLTCs) and shunt capacitors. The goal is to minimize the accumulative expense caused by load reduction payment or penalty, as well as DER operation cost. As a result, the overall system will survive longer with higher resilience during an extreme event. To verify the effectiveness of the PEER algorithm, we proposed a resilience evaluation algorithm using Monte Carlo simulation (MCS) with reduced scenarios. This is based on a probabilistic model for generating random scenarios which consider the uncertainty of line faults and solar irradiance. Combined with the proposed PEER algorithm, this reduced-scenario MCS can evaluate the expected energy not served (EENS) which is an essential index for distribution system resilience. Case studies of the IEEE 33-bus and 123-bus test systems validate the proposed algorithm in reducing EENS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost details from front-end engineering design of piperazine with the advanced stripper

This Front-End Engineering Design (FEED) was funded by the U.S. Department of Energy (DOE) to estimate the cost to capture and compress 90% of the CO 2 from an existing natural gas combined cycle (NGCC) in Denver City, Texas, USA. The FEED used the PZAS (Piperazine with the Advanced Stripper) 2G amine scrubbing technology developed and modeled by The University of Texas at Austin. This FEED is unique in providing more public cost details than other FEEDs funded by DOE. The primary objective of the FEED was to provide a comprehensive estimate for the total installed cost of the capture plant. The estimated capital cost of NGCC at the Mustang Station is $\$727$ million for a capacity of 460 MW and 1.6 million tonnes CO 2 /yr. This includes a contingency of $\$104.6$ million and a contractor’s profit of $\$60.1$ million. The total direct field cost is $\$384.1$ million. With an optimistic fuel value of $\$3$/MMBtu, the estimated cost of capture varies from $\$85$/t at 4% IRR/85% load to $\$170$/t at 10% IRR/52% load. Air cooling is technically feasible but expensive. The air cooling systems for the water wash and pump-around intercooling account for 23.4% of the direct cost. The gas-fired boilers represent only 4% of the direct costs, but steam extraction would reduce energy cost, free up cooling water, and reduce the direct costs of processing additional flue gas and CO 2 from the boilers. The absorbers represent 9.6% of the direct cost in this FEED with no direct contact cooler and only 7.6 m of packing. Furthermore, the solvent cross exchangers are less expensive than expected (2.5% of direct costs). Doubling the number of these exchangers could reduce the heat duty from 3.0 to 2.5 GJ/t CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The role of annealing and grain boundary controls on the mechanical properties of limestones and marbles

Chemical and mechanical processes are coupled in many geological and geochemical environments. Reactive processes anneal defects and restructure grain boundaries, modifying their elastic properties, levels of internal friction, wave propagation rates and fracture behaviors. The nature of these changes is, however, contingent on the initial state of the rock. Here, in this study, impulse excitation was used to measure changes in mechanical properties as a function of dry and steam heating time at 300 °C for three carbonate rocks: Carrara marble, Carthage marble (Burlington Limestone), and Texas Cream limestone (Edwards limestone), with initial porosities of about 1 %, 3 %, and 27 %, respectively. Frequency-dependent phenomena along with mineral recrystallization were observed. This was coupled with small-angle X-ray and neutron scattering analysis to determine the relationship between changes in bulk mechanical and microstructural properties. An observed decrease in both the Young's and shear moduli in the experimental limestones as a function of heating time reflects and quantifies a reduction in the stiffness of the rock due to annealing. The internal friction of the samples first increases then decreases with reaction time, reflecting defect annealing, but this was balanced against grain boundary dissolution apparently driven by condensation of steam in the confined grain-boundary environment. This suggests an increase in the boiling point under confinement leading to dissolution, increased porosity and widening of the grain boundaries. In addition, comparison of small-angle X-ray and neutron scattering results suggests that it is inappropriate to assume that pores are empty for quantitative analysis of typical small-angle scattering samples.

58 GEOSCIENCES↗

Synthesis and optimized formulation for high-capacity manganese fluoride (MnF 2 ) electrodes for lithium-ion batteries

Electrochemical activity of poorly conductive metal fluorides in Li-ion batteries is contingent on their nanostructuration to reduce diffusion lengths and increase reaction kinetics. In that regard, we optimize the synthesis and electrode formulation of MnF 2 to enable sufficient electrochemical activity required to study its electrochemical conversion reaction mechanism. Solvothermal synthesis in a water–ethanol mixture (1:1 Vol.), using Mn acetate and a slight excess of hydrofluoric acid (HF), results in pure phase, nanosized (˜30 nm diameter) rutile-type MnF 2 ( P 4 2 /mnm). High energy ball-milling of MnF2–carbon mixtures leads to an amorphization of MnF 2 and its partial phase transformation to the α-PbO 2 -type structure, without significant improvement of the electrochemical performance. Changing the electrode binder, however, from typical polyvinylidene fluoride (PVDF) to water-soluble Na-alginate, leads to a significant improvement of the reversibility of the electrochemical reaction. Here, we attribute this drastic improvement to the improved adherence and homogeneity of the electrode film prepared with Na-alginate.

25 ENERGY STORAGE↗

Dynamic modeling studies of basin-scale pressure interference and CO 2 plume evolution in multi-well geologic CO 2 storage

This research employs numerical modeling to analyze how CO 2 plumes and pressure fronts evolve when CO 2 is injected into a single storage formation from multiple projects located in proximity. Here, this analysis also evaluates the extent to which injection well spacing alleviates pressure buildup in the absence of active pressure management tactics. The simulation approach was based on a single, homogenous saline aquifer in which CO 2 injection occurs under a one-injector baseline case and several multi-well cases where well spacing varies. Analysis results show that the extent of pressure buildup is in the range of tens or a few hundreds of kilometers and contingent upon the defining pressure buildup demarcating the front edge. For the geological setting evaluated in this paper, our analysis suggests that without active basin pressure management strategies, commercial-scale projects would likely need to be sited far apart to avoid pressure interference from one another. Analysis results show the radius of CO 2 plume varies approximately from 2 to 3 km from injection wells (each injecting 1 Mt/year for 30 years) depending on cases and modeling parameters assumed. Given the pressure interference, this paper thus draws attention to the importance of greater coordination among storage operators and regulatory stakeholders. Because this analysis assumes a very specific geologic setting, this exploratory analysis bears further investigations across other geologic scenarios.

42 ENGINEERING↗