Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Aeroacoustic Assessment of Wind Plant Controls

The Aeroacoustic Assessment project aims to quantify changes in aeroacoustic noise generation by a utility scale wind turbine operating under imposed yaw offsets common for wake steering and wind plant control strategies. Active plant control utilizing wake deflection control strategies have been shown experimentally and computationally to reliably produce 1-2% of additional annual energy production (AEP) without significant changes in turbine structural loads, the potential impact on aeroacoustic emissions has yet to be quantified or completely understood. Yawed operation of a wind turbine changes the three-dimensional aerodynamic interaction between the rotor blades and the incoming atmospheric flow, leading to changes in noise generation. This work quantifies the extent to which active control induces additional aeroacoustic emissions from additional separation and other flow interaction dynamic effects. Given public concerns about wind turbine noise and the need for observational data required for regulators to establish noise restrictions, we must understand potential acoustic emissions resulting from active control prior to commercial deployment and the development of practical noise reduction methods and technologies. The work outlined in this report details the new aeroacoustic measurement capability developed at NREL and its application to making full-field observations of noise from a utility-scale wind turbine. Preliminary noise modeling with the aeroacoustics module in OpenFAST helped to establish the design of the experiment, specifically targeting the noise observed at observers distributed around the DOE-owned GE 1.5 MW wind turbine. Low-frequency and infrasound measurement capability implemented in this project establish an operational baseline for the wind turbine, setting the stage for future control, rotor blade, and turbine design research.

17 WIND ENERGY↗

Application of an Informatics-Based Decision-Making Framework and Process to the Assessment of Radiation Safety in Nanotechnology

The National Council on Radiation Protection and Measurements (NCRP) has established NCRP Scientific Committee 2-6 to develop a report on the current state of knowledge and guidance for radiation safety programs involved with nanotechnology. Nanotechnology is the understanding and control of matter at the nanoscale, at dimensions between approximately 1 and 100 nanometers, where unique phenomena enable novel applications. While the full report is in preparation, this article presents and applies an informatics-based decision-making framework and process through which the radiation protection community can anticipate that nano-enabled applications, processes, nanomaterials, and nanoparticles are likely to become present or are already present in radiation-related activities; recognize specific situations where environmental and worker safety, health, well-being, and productivity may be affected by nano-related activities; evaluate how radiation protection practices may need to be altered to improve protection; control information, interpretations, assumptions, and conclusions to implement scientifically sound decisions and actions; and confirm that desired protection outcomes have been achieved. This generally applicable framework and supporting process can be continuously applied to achieve health and safety at the convergence of nanotechnology and radiation-related activities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Help for the Developers of Control System Cyber Security Standards

A Catalog of Control Systems Security: Recommendations for Standards Developers (Catalog), aimed at assisting organizations to facilitate the development and implementation of control system cyber security standards, has been developed. This catalog contains requirements that can help protect control systems from cyber attacks and can be applied to the Critical Infrastructures and Key Resources of the United States and other nations. The requirements contained in the catalog are a compilation of practices or various industry bodies used to increase the security of control systems from both physical and cyber attacks. They should be viewed as a collection of recommendations to be considered and judiciously employed, as appropriate, when reviewing and developing cyber security standards for control systems. The recommendations in the Catalog are intended to be broad enough to provide any industry using control systems the flexibility needed to develop sound cyber security standards specific to their individual security requirements.

99 GENERAL AND MISCELLANEOUS↗

Active Aerodynamic Load Control for Wind Turbines

The goal of this project was to develop and demonstrate an advanced dielectric barrier discharge (DBD) plasma actuator technology. We set out to demonstrate the efficacy and impact of the new actuator technology as a key component of an active load control system for wind turbines. A DBD plasma actuator consists of a thin layer of dielectric material separating a pair of offset electrodes. One of those electrodes is embedded between the dielectric layer and a non-conductive substrate, while the other is exposed to air. When driven by an appropriate high voltage waveform, the device ionizes the air near the surface of the dielectric and adjacent to the exposed electrode. Collisions between the ions in the plasma and neutral air molecules result in a wall-jet – a region of induced air velocity that can be used to modify the flow around a lifting body. Use of the device near the trailing edge of a wind turbine blade, designed in such a way as to amplify the effects of the flow-modifying device, can result in large changes to the global forces experienced by the blade. Because of the fast response time of the device, it can allow the turbine to react in real time to changes in the wind associated with turbulence, wind shear, gusts, and the like, when paired with appropriate sensors and control algorithms. The goal of this project was to increase the capacity of the device to induce velocity on its surface at the levels required by large, utility-scale wind turbines. The first technical goal was to increase the induced velocity from the current industry-best of about 4 m/s to 10 m/s by modifying the electrical waveform used to drive the device and by introducing a semi-conductive surface coating to control electrostatic charge build-up on the surface. The second goal was to use the device to modify the lift on a representative airfoil in a wind tunnel, demonstrating a reduction in lift coefficient of 0.2 or better. The third goal was to produce an actuator-induced velocity of 20 m/s. Alongside our partners at the University of Texas at Dallas, we also applied modern, advanced design methods to optimize the impact of the technology on the design of wind turbines. We also had planned to install a segmented, active load control system on a test turbine to demonstrate the ability to reduce unsteady aerodynamic forces on the turbine associated with changes in the wind. The highest induced velocity achieved during this research was 11 m/s. However, practical design constraints limited the change in lift coefficient to about 0.12 for a representative airfoil in the wind tunnel at a Reynolds number of 400,000. The primary conclusion is that the plasma actuator control authority remains insufficient for practical purposes when extrapolated to Reynolds numbers over 1 million. The potential impact of the active lift control concept was evaluated through detailed simulations for three wind turbine sizes: a 3.4MW onshore turbine, a 10MW offshore turbine, and a 15MW offshore turbine. A feedback control system was designed for each turbine within two scenarios: one where the active lift control is used as a retrofit capability on the baseline design, and the other where the designers were permitted to “upscale” the turbines in order increase annual energy production. The levelized cost of energy was then evaluated for the range of turbine sizes and design configuration. It was found that the LCOE reduction associated with active lift control fell in the range of 0.7% to 7.2%, with the highest reduction associated with upscaling the 3.4MW turbine.

17 WIND ENERGY↗

Cyber–physical vulnerability and resiliency analysis for DER integration: A review, challenges and research needs

High penetration of renewable and sustainable Distributed Energy Resources (DER) into the traditional distribution system requires a well-coordinated control strategy for the improvement of system-wide reliability and resiliency. Implementation of such a holistic control architecture requires a flexible, near real-time, and bi-directional communication framework for facilitating the participation of various agents in a multi-vendor heterogeneous smart grid. While the sustainability of energy generation is ensured, this exposes the smart grid to extrinsic cyber threats, and appropriate defense mechanism(s) must be deployed to guarantee continued reliability and resiliency of the power grid. Further, the comprehensive literature review presented in this paper discusses the latest trends in the DER control schemes with fast communication requirements and their accompanying cyber–physical vulnerabilities. These control schemes are compared and contrasted for various traits. A three-level DER system architecture has been depicted, facilitating the deployment of these control schemes. The current developments of standard communication protocols, key security mechanisms, and best practices along major standards and guidelines are explored. The impacts of different attack types with miscellaneous DER functions based on various control schemes and associated mitigation solutions are also provided. Finally, challenges and future research directions for limiting cyber-power susceptibility to enhance resiliency are summarized. The work presented here will help us enabling a cyber-resilient and sustainable smart electric grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tool Support for Software Lookup Table Optimization

A number of scientific applications are performance-limited by expressions that repeatedly call costly elementary functions. Lookup table (LUT) optimization accelerates the evaluation of such functions by reusing previously computed results. LUT methods can speed up applications that tolerate an approximation of function results, thereby achieving a high level of fuzzy reuse. One problem with LUT optimization is the difficulty of controlling the tradeoff between performance and accuracy. The current practice of manual LUT optimization adds programming effort by requiring extensive experimentation to make this tradeoff, and such hand tuning can obfuscate algorithms. In this paper we describe a methodology and tool implementation to improve the application of software LUT optimization. Our Mesa tool implements source-to-source transformations for C or C++ code to automate the tedious and error-prone aspects of LUT generation such as domain profiling, error analysis, and code generation. We evaluate Mesa with five scientific applications. Our results show a performance improvement of 3.0× and 6.9× for two molecular biology algorithms, 1.4× for a molecular dynamics program, 2.1× to 2.8× for a neural network application, and 4.6× for a hydrology calculation. We find that Mesa enables LUT optimization with more control over accuracy and less effort than manual approaches.

Wilcox, Chris↗

A Decade of NSTX Operations Using Collaborative Software

Since the beginning of the National Spherical Torus Experiment's (NSTX) research activities in 1999, open-source and collaborative software have been used extensively for experimental operations. The software included Experimental Physics and Industrial Control System (EPICS) and the Model Data System plus (MDSplus). This paper will begin with a retrospective of ten years of integrated computing, control, and data analysis on NSTX. A variety of practical issues will be reviewed such as: system reliability, availability, and maintainability; using open source software with commercialoff- the-shelf (COTS) hardware; obsolescence and remaining current. Recent improvements, current status, and emerging issues will be presented. Numerous proposals for NSTX upgrades have been made that will extend the performance and operating lifetime of NSTX. In light of this, a collective strategy for improving NSTX's collaborative software model for a new decade of operations will be examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and control of plasma rotation for NSTX using neoclassical toroidal viscosity and neutral beam injection

A model-based feedback system is presented to control plasma rotation in a magnetically confined toroidal fusion device, to maintain plasma stability for long-pulse operation. This research uses experimental measurements from the National Spherical Torus Experiment (NSTX) and is aimed at controlling plasma rotation using two different types of actuation: momentum from injected neutral beams and neoclassical toroidal viscosity generated by three-dimensional applied magnetic fields. Based on the data-driven model obtained, a feedback controller is designed, and predictive simulations using the TRANSP plasma transport code show that the controller is able to attain desired plasma rotation profiles given practical constraints on the actuators and the available measurements of rotation.

feedback control↗

Human Performance Measures for the Evaluation of Nuclear Power Plant Control Room Interfaces: A Systematic Review - 265

The purpose of this study was to review the literature related to measuring human performance in the design and evaluation of the human-system interface (HSI) of nuclear power plant (NPP) control rooms and synthesize lessons learned and future directions for research and practice in this field. The design and evaluation of digital or hybrid HSI requires comprehensive measurement of human performance to ensure quality and safety of the nuclear power process control. Human factors evaluation frameworks have been proposed to guide the measurement of human performance constructs. However, there are few guides for selecting appropriate measures for those constructs. A systematic review of empirical research literature was conducted. Studies were identified through academic publication databases and grey literature searches. Eligible studies were coded and information regarding human performance measures was extracted and analyzed. A total of 80 studies met the criteria. Human performance measures extracted from the reviewed studies included measures of: behavioral performance; workload; situation awareness; human-human or human-machine cooperation; other cognitive performance indicators; and system performance. Behavioral performance (speed and accuracy), workload, and situation awareness were the most frequently measured constructs with validated and domain-specific instruments. The results of the literature review provided an overview of the human performance constructs and their corresponding measures for NPP control room HSI evaluation. These results can be used as an initial guide to establish appropriate and comprehensive measurements of human performance for such evaluations. Future directions in measure development are also discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluating the limitations of Bayesian metabolic control analysis

AbstractBayesian Metabolic Control Analysis (BMCA) has emerged as a promising framework for inferring metabolic control coefficients in data-limited scenarios by integrating Bayesian inference with linlog rate laws. However, its predictive accuracy and limitations remain underexplored. This study systematically evaluates BMCA’s ability to infer elasticity values, flux control coefficients (FCCs), and concentration control coefficients (CCCs) under varying data availability conditions using three synthetic metabolic network models. Our findings highlight the strengths and weaknesses of BMCA, guiding its application in metabolic engineering and emphasizing the need for methodological refinements.Author summaryUnderstanding how enzymes control metabolic pathways is crucial for optimizing biomanufacturing and synthetic biology applications. Bayesian Metabolic Control Analysis (BMCA) is a promising computational method that integrates Bayesian inference with metabolic control analysis to estimate key control parameters, even in cases with limited experimental data. However, the accuracy and limitations of BMCA remain unclear. In this study, we systematically evaluate BMCA using three synthetic metabolic networks to determine how different types of physiological data impact its predictive performance. We find that BMCA requires flux and enzyme concentration data for accurate predictions, while external metabolite concentrations contribute little. Additionally, BMCA fails to predict elasticity values beyond a magnitude of 1.5 and reliably infer allosteric regulation, even when strong regulatory interactions exist. In addition, BMCA does not accurately rank metabolic control points, which may limit its utility in identifying key enzymes in engineered pathways. Our work provides practical insights into when and how BMCA can be applied, guiding future research in metabolic modeling and control analysis.

Shin, Janis (ORCID:0000000216572455)↗

From Molecular to Macroscopic via the Rational Design of a Self-Assembled 3D DNA Crystal

We live in a macroscopic three-dimensional (3D) world, but our best description of the structure of matter is at the atomic and molecular scale. Understanding the relationship between the two scales requires a bridge from the molecular world to the macroscopic world. Connecting these two domains with atomic precision is a central goal of the natural sciences, but it requires high spatial control of the 3D structure of matter1. The simplest practical route to producing precisely designed 3D macroscopic objects is to form a crystalline arrangement by self-assembly, because such a periodic array has only conceptually simple requirements: a motif that has a robust 3D structure, dominant affinity interactions between parts of the motif when it self-associates, and predictable structures for these affinity interactions. Fulfilling these three criteria to produce a 3D periodic system is not easy, but should readily be achieved with well-structured branched DNA motifs tailed by sticky ends2. Complementary sticky ends associate with each other preferentially and assume the well-known B-DNA structure when they do so3; the helically repeating nature of DNA facilitates the construction of a periodic array. It is essential that the directions of propagation associated with the sticky ends do not share the same plane, but extend to form a 3D arrangement of matter. Here we report the crystal structure at 4?Angstroms resolution of a designed, self-assembled, 3D crystal based on the DNA tensegrity triangle4. The data demonstrate clearly that it is possible to design and self-assemble a well-ordered macromolecular 3D crystalline lattice with precise control.

36 MATERIALS SCIENCE↗

Practical Challenges in Real-Time Demand Response

We report on a real-time demand response experiment with 100 controllable devices. The experiment reveals several key challenges in the deployment of a real-time demand response program, including time delays, uncertainties, characterization errors, multiple timescales, and nonlinearity, which have been largely ignored in previous studies. To resolve these practical issues, we develop and implement a two-level multi-loop control structure integrating feed-forward proportional-integral controllers and optimization solvers in closed loops, which eliminates steady-state errors and improves the dynamical performance of the overall building response. Furthermore, the proposed methods are validated by Hardware-in-the-Loop (HiL) tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optical properties of differing nanolayered structures of divalent europium doped barium fluoride thin films synthesized by pulsed laser deposition

Optically-active thin films are employed in a variety of applications, such as LEDs and photovoltaics, due to their ability to act as up- or down-photon energy converters. Their performance depends critically on their composition and structure; thus, the use of novel synthesis techniques that allow for their control at the nanoscale level can result in improved efficiency and practicality. Here, layered thin films consisting of Eu 2+ - doped BaF 2 nanocrystalline layers separated by amorphous Al 2 O 3 were synthesized via sequential pulsed laser deposition using three separate targets for the different components; this synthesis technique provides precise control of layer thickness at the nanoscale along with dopant distribution within the film. Cross-sectional transmission electron microscopy analysis verified the desired nano-layering. Post-deposition heat treatments in a nitrogen atmosphere resulted in samples exhibiting steady emission with a broad peak ranging from 400 to 600 nm and a shoulder at 410 nm. The CIE 1931 chromaticity coordinates are x = 0.26-0.29 and y = 0.32-0.35 and vary as a function of the sample configuration. Because the chromaticity coordinates are close to those of a pure white light (x = 0.33, y = 0.33), these films demonstrate advantageous properties for applications with UV-pumped white light LEDs.

36 MATERIALS SCIENCE↗

Is Corn Stover Harvest Predictable Using Farm Operation, Technology, and Management Variables?

Core Ideas Corn stover removal was not common in 2010. Crop sequences were similar for stover and non‐stover harvest farms. State‐level variation occurred in the relative size of farms removing corn stover. Soil erosion control measures were not frequently adopted by either farm group. Crop residue management, provision of animal feed or bedding, and increased income are potential reasons for harvesting corn ( Zea mays L.) stover. Reasons for not doing so include the need for crop residue to restore or increase soil organic matter, protect against wind and water erosion, and cycle plant nutrients. Bioenergy market development may increase the number of producers harvesting corn stover. Can farming practice data predict the likelihood for harvesting corn stover at a national scale? Farm operation, technology, and management variables from the 2010 Agricultural Resource Management Survey (ARMS) of U.S. corn growers were compared between operations that removed corn stover and those that did not. Nationwide, stover was removed from approximately 6.3% of all corn operations, indicating stover harvest was not a common practice in 2010. Factors increasing the likelihood for stover harvest included producing feed corn, managing crop residues for pest control, and farmland ownership. Technology and conservation practice adoption rates were similar in both groups. Excessive stover removal can increase soil degradation. Both groups had erosion control adoption rates of ≤10%, which may provide an additional disincentive to harvest stover. Overall, the evaluated variables were similar between producers that did and did not harvest stover. This assessment provides a 2010 national baseline that can be used for future evaluations as bioenergy and bioproduct markets develop.

54 ENVIRONMENTAL SCIENCES↗

SLUDGE BATCH 7B GLASS VARIABILITY STUDY

The Defense Waste Processing Facility (DWPF) is preparing to initiate processing Sludge Batch 7b (SB7b). In support of the upcoming processing, the Savannah River National Laboratory (SRNL) provided a recommendation to utilize Frits 418 with a 6% Na{sub 2}O addition (26 wt% Na{sub 2}O in sludge) and 702 with a 4% Na{sub 2}O addition (24 wt% Na{sub 2}O in sludge) to process SB7b. This recommendation was based on assessments of the compositional projections for SB7b available at the time from the Savannah River Remediation (SRR). To support qualification of SB7b, SRNL executed a variability study to assess the applicability of the current durability models for SB7b. The durability models were assessed over the expected composition range of SB7b, including potential caustic additions, combined with Frits 702 and 418 over a 32-40% waste loading (WL) range. Thirty four glasses were selected based on Frits 418 and 702 coupled with the sludge projections with an additional 4-6% Na{sub 2}O to reflect the potential caustic addition. Six of these glasses, based on average nominal sludge compositions including the appropriate caustic addition, were developed for both Frit 418 and Frit 702 at 32, 36 and 40% WL to provide coverage in the center of the anticipated SB7b glass region. All glasses were fabricated and characterized using chemical composition analysis, X-ray diffraction (XRD) and the Product Consistency Test (PCT). To comply with the DWPF Glass Product Control Program, a total of thirty four glasses were fabricated to assess the applicability of the current DWPF PCCS durability models. Based on the measured PCT response, all of the glasses were acceptable with respect to the Environmental Assessment (EA) benchmark glass regardless of thermal history. The NL[B] values of the SB7b variability study glasses were less than 1.99 g/L as compared to 16.695 g/L for EA. A small number of the D-optimally selected 'outer layer' extreme vertices (EV) glasses were not predictable using the current Product Composition Control System (PCCS) models for durability, but were acceptable compared to the EA glass when tested. These glasses fell outside of the lower 95% confidence band, which demonstrates conservatism in the model. A few of the glasses fell outside of the upper 95% confidence band; however, these particular glasses have normalized release values that were much lower than the values of EA and should be of no practical concern. Per the requirements of the DWPF Glass Product Control Program, the PCCS durability models have been shown to be applicable to the SB7b sludge system with a range of Na{sub 2}O concentrations blended with Frits 418 or 702. PCT results from the glasses fabricated as part of the variability study were shown to be predictable by the current DWPF PCCS models and/or acceptable with respect to the EA benchmark glass regardless of thermal history or compositional view.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Decomposition Approach for Solving Seasonal Transmission Switching

Economic transmission switching has been proposed as a new control paradigm to improve the economics of electric power systems. In practice, the transmission switching operation itself is a disruptive action to the system. Frequently switching lines into or out of service can create undesirable effects on the security and reliability of power systems and may require new investments in the automation and control systems. In this paper, we formulate an economic seasonal transmission switching model where transmission switching occurs once at the beginning of a time period (season) and then the transmission topology remains unchanged during that period. The proposed seasonal transmission switching model is a large-scale mixed integer programming problem. The objective of the optimization model is to minimize the total energy generation cost over the season subject to loads and N-1 reliability requirements. We develop a novel decomposition method that decomposes the seasonal problem into one-hour problems which are then solved efficiently. We demonstrate our model and the decomposition approach on the 14-bus, 39-bus, and 118-bus power systems and show potential cost savings in each case.

Decomposition↗

Expert Elicitation on Wind Farm Control

Wind farm control is an active and growing field of research in which the control actions of individual turbines in a farm are coordinated, accounting for inter-turbine aerodynamic interaction, to improve the overall performance of the wind farm and to reduce costs. The primary objectives of wind farm control include increasing power production, reducing turbine loads, and providing electricity grid support services. Additional objectives include improving reliability or reducing external impacts to the environment and communities. In 2019, a European research project (FarmConners) was started with the main goal of providing an overview of the state-of-the-art in wind farm control, identifying consensus of research findings, data sets, and best practices, providing a summary of the main research challenges, and establishing a roadmap on how to address these challenges. Complementary to the FarmConners project, an IEA Wind Topical Expert Meeting (TEM) and two rounds of surveys among experts were performed. From these events we can clearly identify an interest in more public validation campaigns. Additionally, a deeper understanding of the mechanical loads and the uncertainties concerning the effectiveness of wind farm control are considered two major research gaps.

17 WIND ENERGY↗