Precursor Analysis Report: Doppelpaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019

The DoppelPaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019 Precursor Analysis Report leverages publicly available information about the PEMEX cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. The 2019 DoppelPaymer ransomware attack on PEMEX, Mexico’s nationalized petroleum corporation, highlights a unique threat that ransomware and cybercriminal extortion poses to Operational Technology (OT) environments in critical infrastructure. The incident began with an employee downloading commodity malware that allowed adversaries to gain initial access to PEMEX’s enterprise environment. After conducting privilege escalation, tool ingress, and data exfiltration, the adversaries deployed DoppelPaymer ransomware throughout the PEMEX enterprise environment, resulting in the company having to take dozens of systems offline for at least several days. Although PEMEX stated that their operations were not affected, the data exfiltrated from PEMEX was made available for download on DoppelPaymer’s leak site, as well as on other illicit criminal forums. This stolen data included not only company information, but also sensitive OT-specific configuration data. This incident showcases how cybercriminal exfiltration and posting of sensitive OT architecture documentation can pose security concerns for the targeted organization for years due to the long lifespan of OT assets and architectures. Researchers and analysts identified 18 unique techniques utilized during the attack with a total of 190 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the DoppelPaymer ransomware attack were precursors to the triggering event. Analysis identified 163 observables associated with these precursor techniques, 34 of which were assessed to have an increased likelihood of being perceived in the 60 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Building Nuclear-Specific Cybersecurity Expertise in Higher Education

The rapid digitalization of nuclear power plants (NPPs) and the deployment of advanced and small modular reactors (A/SMRs) have expanded the cybersecurity attack surface within the nuclear sector. This evolution introduces unique challenges beyond those faced in general information technology (IT), operational technology (OT) and industrial control system (ICS) security, due to nuclear power’s regulatory rigor, safety-critical nature, and operational needs. A pressing workforce gap persists; cybersecurity graduates typically lack nuclear-specific context and retraining them for industry readiness requires 12–18 months, creating a significant burden. This paper addresses this gap by defining the domains of knowledge that nuclear cybersecurity specialists must master, spanning cybersecurity, nuclear engineering, OT/ICS security, and regulatory governance. We propose a curricular framework integrating technical, regulatory, and applied learning components to accelerate workforce readiness. Our approach builds on existing findings that current curricula inadequately integrate nuclear engineering and cybersecurity, shifting the discourse from why specialization is needed to what knowledge must be taught. The recommendations have implications for workforce development and long-term resilience of the nuclear energy sector.

99 - GENERAL AND MISCELLANEOUS↗

Cybersecurity through Real-Time Distributed Control Systems

Critical infrastructure sites and facilities are becoming increasingly dependent on interconnected physical and cyber-based real-time distributed control systems (RTDCSs). A mounting cybersecurity threat results from the nature of these ubiquitous and sometimes unrestrained communications interconnections. Much work is under way in numerous organizations to characterize the cyber threat, determine means to minimize risk, and develop mitigation strategies to address potential consequences. While it seems natural that a simple application of cyber-protection methods derived from corporate business information technology (IT) domain would lead to an acceptable solution, the reality is that the characteristics of RTDCSs make many of those methods inadequate and unsatisfactory or even harmful. A solution lies in developing a defense-in-depth approach that ranges from protection at communications interconnect levels ultimately to the control system s functional characteristics that are designed to maintain control in the face of malicious intrusion. This paper summarizes the nature of RTDCSs from a cybersecurity perspec tive and discusses issues, vulnerabilities, candidate mitigation approaches, and metrics.

97 MATHEMATICS AND COMPUTING↗

Cyber-Physical Security and Resiliency Analysis Testbed for Critical Microgrids with IEEE 2030.5: Preprint

IEEE 2030.5, also known as the Common Smart Inverter Standard (CSIP) is a protocol that specifies the interface between the end user and the smart grid. This standard was proposed recently, and provides many functions which if implemented incorrectly might lead to vulnerabilities. This paper proposes a cyber-physical microgrid testbed using OpenDSS and IEEE 2030.5 that can be used to study the performance of the CSIP protocol various scenarios. For critical microgrid installations, it is essential that the critical loads are served in spite of multiple contingencies. A resiliency analysis is performed for a military microgrid to study its performance and the results are analyzed.

CVSS↗

Managing Cyber Supply Chain Risk for Renewable Energy Technologies

On July 1, 2021, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) hosted a virtual workshop facilitated by the National Renewable Energy Laboratory (NREL). Cybersecurity supply chain experts, researchers, and leaders in government and industry came together to share information on current and future challenges in securing emerging technologies and technical architecture. From a cybersecurity perspective, we need to move from a cybersecurity approach that focuses principally on legacy asset owners to one that incorporates more emphasis on end-point device manufacturers and third-party integrators. Cybersecurity for the global digital supply chain for manufacturers of consumer end-point devices—such as smart solar inverters and smart electric vehicle (EV) chargers—will be critical to the future cyber health of the grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-driven Cyberattack Detection for Photovoltaic (PV) Systems through Analyzing Micro-PMU Data

With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.

14 SOLAR ENERGY↗

Risk Assessment at the Edge: Applying NERC CIP to Aggregated Grid-Edge Resources

Distributed energy resources (DERs) promise to deliver benefits for both utilities and consumers by dynamically interoperating utility systems with customer-owned grid-edge technologies. These small energy-consuming devices are increasingly being aggregated for participation in grid markets, planning and operations. A cyber attack penetrating the control system of aggregated DERs could negatively impact the operation of the grid. In the worst case, the power grid could be severely damaged and physical safety compromised. In this paper we analyze cybersecurity risks associated with the aggregation of DERs and develop an approach to mitigating that risk. The approaches to both cyber risk analysis and mitigation were developed during a recent research project that serves as an example of how the approaches could be applied. However, both the risk analysis and mitigation are applicable to the broader domain of all DERs. An important conclusion is that the successful cyber compromise of aggregated DERs could have a significant impact on the bulk power system. This is the case even if each individual DER falls below the threshold of compliance with bulk-grid cybersecurity standards. For this reason, we specifically investigate how National Electricity Reliability Corporation's Critical Infrastructure Protection requirements could flow down to interactions between DER aggregators and the DERs themselves in order to protect the grid from these bulk-scale cyber attack impacts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Co-Simulation Platform For Characterizing Cyber Attacks in Cyber Physical Systems

Smart grid is a complex cyber physical system containing a numerous and variety of sources, devices, controllers and loads. Communication/Information infrastructure is the backbone of the smart grid system where different grid components are connected with each other through this structure. Therefore, the drawbacks of the information technology related issues are also becoming a part of the smart grid. Further, smart grid is also vulnerable to the grid related disturbances. For such a dynamic system, disturbance and intrusion detection is a paramount issue. This paper presents a Simulink and OPNET based co-simulated test bed to carry out a cyber-intrusion in a cyber-network for modern power systems and smart grid. The effect of the cyber intrusion on the physical power system is also presented. The IEEE 30 bus power system model is used to demonstrate the effectiveness of the simulated testbed. The experiments were performed by disturbing the circuit breakers reclosing time through a cyber-attack in the cyber network. Different disturbance situations in the proposed test system are considered and the results indicate the effectiveness of the proposed co-simulated scheme.

cyber attack characterization↗

Intelligent Buildings of the Future: Cyberaware, Deep Learning Powered, and Human Interacting

This study discuss, intelligent buildings are quickly becoming cohesive and integral entities of cyber-physical ecosystems. Modern buildings adapt to internal and external elements and thrive on ever increasing data sources such as ubiquitous smart devices and sensors while mimicking various approaches previously known in software, hardware, and bio inspired systems. This article provides an overview of intelligent buildings of the future from a range of perspectives. First, a brief overview of prospects of U.S. and world energy consumption, concepts of smart buildings as integral entities of smart grids is presented. This is followed by a discussion of the role of connectivity and interoperability as well as current issues and solutions in the areas of security, resilience, and humans in realm of intelligent buildings. The article dives into detail about the intelligence aspect of intelligent buildings of the future. The learning and predictive Artificial Intelligence (AI) techniques behind many of the concepts of intelligent buildings are reviewed, including the latest techniques such as deep learning. As a concrete application of AI in the realm of intelligent buildings, prediction of energy consumption/load/demand, which is a much researched application of AI in the realm of intelligent buildings, is elaborated. The discussion is focused on most recent advancements of AI based demand prediction and the overview consists of existing research and a case study conducted by the authors for deep learning based demand prediction. Then, the article discusses the role of humans in intelligent buildings. Different types of human-building interactions are identified. Further, the article presents how each type of human-building interaction can benefit the overall control of intelligent buildings. The section is concluded by elaborating a case study conducted by the authors to achieve effective and efficient human-building interaction. The article is concluded with compilation of future insights based on latest technological advancements in U.S. industry and government.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Examination of the role of nuclear deterrence in the 21st century: a systems analysis approach

Until very recently, an evaluation of US policy regarding deterrence and the role of its nuclear weapons arsenal as a deterrent has been largely absent in the public debate. With President's Obama embrace of a goal of a future world without nuclear weapons, issues of nuclear policy and deterrence have just recently risen to the forefront of policy discussions. The traditional role of US nuclear weapons-to deter the use of nuclear weapons by other states-endures, but is no longer unique nor even predominant. In an increasingly multi-polar world, the US now faces growing risks of nuclear weapons proliferation; the spread of weapons of mass destruction generally to non-state, substate and transnational actors; cyber, space, economic, environmental and resource threats along with the application of numerous other forms of 'soft power' in ways that are inimical to national security and to global stability. What concept of deterrence should the US seek to maintain in the 21st Century? That question remains fluid and central to the current debate. Recently there has been a renewed focusing of attention on the role of US nuclear weapons and a national discussion about what the underlying policy should be. In this environment, both the United States and Russia have committed to drastic reductions in their nuclear arsenals, while still maintaining forces sufficient to ensure unacceptable consequence in response to acts of aggression. Further, the declared nuclear powers have maintained that a limited nuclear arsenal continues to provide insurance against uncertain developments in a changing world. In this environment of US and Russian stockpile reductions, all declared nuclear states have reiterated the central role which nuclear weapons continue to provide for their supreme national security interests. Given this new environment and the challenges of the next several decades, how might the United States structure its policy and forces with regard to nuclear weapons? Many competing objectives have been stated across the spectrum of political, social, and military thought. These objectives include goals of ratification of the Comprehensive Test Ban Treaty, recommitment to further downsizing of the nuclear arsenal, embracing a long-term goal of the elimination of nuclear weapons, limitations on both the production complex and upgrades to nuclear weapons and delivery systems, and controls and constraints to limit proliferation of nuclear materials and weapons, particularly to rogue states and terrorist groups.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reactor System Facility Modification to Detect Compromised Human Machine Interfaces

This study focuses on a multi-layered Industrial Control System (ICS)/Operational Technology (OT) security architecture to aid in the discovery and mitigation of compromised Human Machine Interface (HMI)/Instrumentation & Control (I&C) based systems for modifying a prototypical reactor condition test facility called the Flowing Autoclave System (FAS) at Idaho National Laboratory (INL). This is achieved through a three-layered combination of network security solutions, hash-based algorithms, and blockchain technologies. Hash algorithms are mathematical functions used to generate a predetermined set of fixed-length values. They are widely used in computer security to verify the integrity of system information and data, both on a local network and the wider internet. Even small amounts of unauthorized system modification will cause the hash algorithm to output a set of characters that deviate significantly from its original value. Assisting secure hash functions, blockchain technology is a secure and distributed technology used to provide an immutable set of records replicated on all devices within a decentralized network. Blockchain offers a cost-effective solution to detect system compromise by providing a traceable breadcrumb trail of all network activity and data modification happening on a system. If both are used in conjunction with network monitoring tools, the integration of this three-pronged approach can become an asset in detecting suspected system compromises before any real damage can occur.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NASA’s Secured Airspace for Urban Air Mobility (UAM)

The Urban Air Mobility (UAM) architecture is leveraged from the Unmanned Traffic Management (UTM) concept of operations. Within the UAM environment, UAM operators work collaboratively to manage aerial vehicles in the urban environment. Providers of Services for UAM (PSU), UAM operators, and Supplemental Data Service Providers (SDSP) provide services to support flight operations within that environment. As a recognized need, various views of UAM flight information are provided to the public and public safety entities. To accomplish this, among other goals, the Federal Aviation Administration (FAA) can coordinate flight information between the FAA controlled National Airspace System (NAS) and the UAM environments through the FAA-Industry Data Exchange Protocol (FIDXP). This concept of UAM proposes to develop short-range, point-to-point transportation systems in metropolitan areas using vertical take-off and landing (VTOL) or short take-off and landing (STOL) aircraft to overcome increasing surface congestion. To garner the support of UAM and to realize its potential, an assurance of cybersecurity is critical for public acceptance. Understanding the various components communicating with one-another cybersecurity, like in other industries, has come to the forefront highlighting the need to protect these networks and systems from cyberattacks. With the planned growth and reach of UAM systems, it’s clear that the associated data exchange and service interactions will be at risk due to numerous types of cybersecurity attacks. Consequently, as these threats evolve, the UAM cybersecurity capabilities must adapt to these changes as well. While learning is always the goal, the overall intent of this workshop is to make recommendations on the following: (1) how future UAM environments can be protected against cyber-attacks, and (2) what mechanisms should be put in place to detect attacks against UAM environments.

UAM↗

Ten million and one penguins, or, lessons learned from booting millions of virtual machines on HPC systems.

In this paper we describe Megatux, a set of tools we are developing for rapid provisioning of millions of virtual machines and controlling and monitoring them, as well as what we've learned from booting one million Linux virtual machines on the Thunderbird (4660 nodes) and 550,000 Linux virtual machines on the Hyperion (1024 nodes) clusters. As might be expected, our tools use hierarchical structures. In contrast to existing HPC systems, our tools do not require perfect hardware; that all systems be booted at the same time; and static configuration files that define the role of each node. While we believe these tools will be useful for future HPC systems, we are using them today to construct botnets. Botnets have been in the news recently, as discoveries of their scale (millions of infected machines for even a single botnet) and their reach (global) and their impact on organizations (devastating in financial costs and time lost to recovery) have become more apparent. A distinguishing feature of botnets is their emergent behavior: fairly simple operational rule sets can result in behavior that cannot be predicted. In general, there is no reducible understanding of how a large network will behave ahead of 'running it'. 'Running it' means observing the actual network in operation or simulating/emulating it. Unfortunately, this behavior is only seen at scale, i.e. when at minimum 10s of thousands of machines are infected. To add to the problem, botnets typically change at least 11% of the machines they are using in any given week, and this changing population is an integral part of their behavior. The use of virtual machines to assist in the forensics of malware is not new to the cyber security world. Reverse engineering techniques often use virtual machines in combination with code debuggers. Nevertheless, this task largely remains a manual process to get past code obfuscation and is inherently slow. As part of our cyber security work at Sandia National Laboratories, we are striving to understand the global network behavior of botnets. We are planning to take existing botnets, as found in the wild, and run them on HPC systems. We have turned to HPC systems to support the creation and operation of millions of Linux virtual machines as a means of observing the interaction of the botnet and other noninfected hosts. We started out using traditional HPC tools, but these tools are designed for a much smaller scale, typically topping out at one to ten thousand machines. HPC programming libraries and tools also assume complete connectivity between all nodes, with the attendant configuration files and data structures to match; this assumption holds up very poorly on systems with millions of nodes.

99 GENERAL AND MISCELLANEOUS↗

Perturbation-Based Diagnosis of False Data Injection Attack Using Distributed Energy Resources

Modern smart grid relies on various sensor measurements for its operational control. In a successful false data injection attack, the attacker manipulates the measurements from the grid sensors such that undetected errors are introduced into the estimates of the system parameters leading to catastrophic situations. This paper proposes a novel perturbation based false data injection attack detection mechanism that utilizes inverter based distributed energy resources (DERs) to create low magnitude perturbation signal in the distribution system voltage that is inconsequential to the normal grid operation. Two voltage sensitivity analysis based algorithms are designed to identify the optimal set of DERs that can create the voltage perturbation signal of desired magnitude. An analytical method of voltage sensitivity analysis is used to compute the magnitude of voltage perturbation signal at each node in a computationally efficient manner. Then, a detection mechanism is developed that checks for the presence of the perturbation sequence in each sensor measurement. A sensor measurement is deemed authentic if the voltage perturbation signal is present in the data. In case of sensor malfunction or cyber-attack, the perturbation signal will not be present in the measurement data. Performance of the proposed attack detection mechanism is validated via simulation of the IEEE 69 bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling, Simulation and Analysis of Complex Networked Systems: A Program Plan for DOE Office of Advanced Scientific Computing Research

Many complex systems of importance to the U.S. Department of Energy consist of networks of discrete components. Examples are cyber networks, such as the internet and local area networks over which nearly all DOE scientific, technical and administrative data must travel, the electric power grid, social networks whose behavior can drive energy demand, and biological networks such as genetic regulatory networks and metabolic networks. In spite of the importance of these complex networked systems to all aspects of DOE's operations, the scientific basis for understanding these systems lags seriously behind the strong foundations that exist for the 'physically-based' systems usually associated with DOE research programs that focus on such areas as climate modeling, fusion energy, high-energy and nuclear physics, nano-science, combustion, and astrophysics. DOE has a clear opportunity to develop a similarly strong scientific basis for understanding the structure and dynamics of networked systems by supporting a strong basic research program in this area. Such knowledge will provide a broad basis for, e.g., understanding and quantifying the efficacy of new security approaches for computer networks, improving the design of computer or communication networks to be more robust against failures or attacks, detecting potential catastrophic failure on the power grid and preventing or mitigating its effects, understanding how populations will respond to the availability of new energy sources or changes in energy policy, and detecting subtle vulnerabilities in large software systems to intentional attack. This white paper outlines plans for an aggressive new research program designed to accelerate the advancement of the scientific basis for complex networked systems of importance to the DOE. It will focus principally on four research areas: (1) understanding network structure, (2) understanding network dynamics, (3) predictive modeling and simulation for complex networked systems, and (4) design, situational awareness and control of complex networks. The program elements consist of a group of Complex Networked Systems Research Institutes (CNSRI), tightly coupled to an associated individual-investigator-based Complex Networked Systems Basic Research (CNSBR) program. The CNSRI's will be principally located at the DOE National Laboratories and are responsible for identifying research priorities, developing and maintaining a networked systems modeling and simulation software infrastructure, operating summer schools, workshops and conferences and coordinating with the CNSBR individual investigators. The CNSBR individual investigator projects will focus on specific challenges for networked systems. Relevancy of CNSBR research to DOE needs will be assured through the strong coupling provided between the CNSBR grants and the CNSRI's.

97 MATHEMATICS AND COMPUTING↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.