Concept-Development of a Structure Supported Membrane for Deployable Space Applications - From Nature to Manufacture and Testing

Current space applications of membrane structures include large area solar power arrays, solar sails, antennas, and numerous other large aperture devices like the solar shades of the new James Webb Space Telescope. These expandable structural systems, deployed in-orbit to achieve the desired geometry, are used to collect, reflect and/or transmit electromagnetic radiation. This work, a feasibility study supporting a diploma thesis, describes the systematic process for developing a biologically inspired concept for a structure supported (integrated) membrane, that features a rip stop principle, makes self-deployment possible and is part of an ultra-light weight space application. Novel manufacturing of membrane prototypes and test results are presented for the rip-stop concepts. Test data showed that the new membrane concept has a higher tear resistance than neat film of equivalent mass.

Zander, Martin↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Stochastic Charging Station Deployment Model for Electrified Taxi Fleets in Coupled Urban Transportation and Power Distribution Networks

Metropolitansworldwide are increasingly adopting electric taxis (ET) to address concerns about transportation-related emissions. However, the widespread deployment of electric taxis presents challenges in terms of increased electricity demand and changing demand profiles. This transition impacts both the urban transportation network (TN) and the electricity power distribution network (PDN), highlighting the interdependence between these two systems. Here, in this paper, we propose a two-stage stochastic programming planning model that aims to optimize both the TN and PDN, enabling efficient deployment of charging stations and grid upgrades. Our model seeks to strike a balance between meeting ET drivers' charging preferences, minimizing the costs associated with infrastructure deployment and grid expansion, and harmonizing the coordination between the TN and PDN. Additionally, we explore the potential benefits of utilizing an autonomous ET fleet to enhance overall system performance.

33 ADVANCED PROPULSION SYSTEMS↗

MiniCarb: a passive, occultation-viewing, 6U CubeSat for observations of CO 2 , CH 4 , and H 2 O

In this report we present the final design, environmental testing, and launch history of MiniCarb, a 6U CubeSat developed through a partnership between NASA Goddard Space Flight Center and Lawrence Livermore National Laboratory. MiniCarb’s science payload, developed at Goddard, was an occultation-viewing, passive laser heterodyne radiometer for observing methane, carbon dioxide, and water vapor in Earth’s atmosphere at ~1.6 µm s -1 . MiniCarb’s satellite, developed at Livermore, implemented their CubeSat Next Generation Bus plug-and-play architecture to produce a modular platform that could be tailored to a range of science payloads. Following the launch on 5 December 2019, MiniCarb traveled to the International Space Station and was set into orbit on 1 February 2020 via Northrop Grumman’s Cygnus capsule which deployed MiniCarb with tipoff rotation of about 20° s (significantly higher than the typical rate of 3° s -1 from prior CubeSats), from which the attitude control system was unable to recover resulting in a loss of power. In spite of this early failure, MiniCarb had many successes including rigorous environmental testing, successful deployment of its solar panels, and a successful test of the radio and communication through the Iridium network. This prior work and enticing cost (approximately $\$2$ M for the satellite and $\$$250 K for the payload) makes MiniCarb an ideal candidate for a low-cost and rapid rebuild as a single orbiter or constellation to globally observe key greenhouse gases.

47 OTHER INSTRUMENTATION↗

Design of an unmanned Martian polar exploration system

The design of an unmanned Martian polar exploration system is presented. The system elements include subsystems for transportation of material from earth to Mars, study of the Martian north pole, power generation, and communications. Early next century, three Atlas 2AS launch vehicles will be used to insert three Earth-Mars transfer vehicles, or buses, into a low-energy transfer orbit. Capture at Mars will be accomplished by aerobraking into a circular orbit. Each bus contains four landers and a communications satellite. Six of the twelve total landers will be deployed at 60 deg intervals along 80 deg N, and the remaining six landers at 5 deg intervals along 30 deg E from 65 deg N to 90 deg N by a combination of retrorockets and parachutes. The three communications satellites will be deployed at altitudes of 500 km in circular polar orbits that are 120 deg out of phase. These placements maximize the polar coverage of the science and communications subsystems. Each lander contains scientific equipment, two microrovers, power supplies, communications equipment, and a science computer. The lander scientific equipment includes a microweather station, seismometer, thermal probe, x-ray spectrometer, camera, and sounding rockets. One rover, designed for short-range (less than 2 km) excursions from the lander, includes a mass spectrometer for mineral analysis, an auger/borescope system for depth profiling, a deployable thermal probe, and charge coupled device cameras for terrain visualization/navigation. The second rover, designed for longer-range (2-5 km) excursions from the lander, includes radar sounding/mapping equipment, a seismometer, and laser ranging devices. Power for all subsystems is supplied by a combination of solar cells, Ni-H batteries, and radioisotope thermoelectric generators. Communications are sequenced from rovers, sounding rockets, and remote sensors to the lander, then to the satellites, through the Deep Space Network to and from earth.

Baldwin, Curt↗

A Blockchain Based Co-Simulation Framework for Integrating DERs into Wholesale Electricity Markets

As the number of distributed energy resources (DERs) continue to increase across energy-delivery systems, there remains a need for integrating their capabilities into traditional grid operations. In this paper, a blockchain-based solution is proposed to facilitate FERC's Order No. 2222 implementations. The presented use-case enables small-scale DERs to participate in wholesale market operations through DER aggregators, while also enabling local distribution system operators to enforce distribution system constraints in a secure and traceable manner. The presented use case is built around the Unified Testing Platform (UTP) being developed as a part of the Blockchain for Optimized Security and Energy Management (BLOSEM) project. This is a multi-lab effort intended to simplify the deployment of blockchain-powered grid solutions by enabling the integration of simulation tools, and blockchain technologies through the use of system-agnostic interfaces that provide a modular, interoperable, and reusable connectivity layer.

blockchain testing↗

A Blockchain Based Co-Simulation Framework for Integrating DERs to Wholesale Electricity Markets: Preprint

As the number of distributed energy resources (DERs) continue to increase across energy-delivery systems, there remains a need for integrating their capabilities into traditional grid operations. In this paper, a blockchain-based solution is proposed to facilitate FERC's Order No. 2222 implementations. The presented use-case enables small-scale DERs to participate in wholesale market operations through DER aggregators, while also enabling local distribution system operators to enforce distribution system constraints in a secure and traceable manner. The presented use case is built around the Unified Testing Platform (UTP) being developed as a part of the Blockchain for Optimized Security and Energy Management (BLOSEM) project. This is a multi-lab effort intended to simplify the deployment of blockchain-powered grid solutions by enabling the integration of simulation tools, and blockchain technologies through the use of system-agnostic interfaces that provide a modular, interoperable, and reusable connectivity layer.

blockchain testing↗

Design and Prototyping of Advanced Control Systems for Advanced Reactors Operating in the Future Electric Grid (Final Report)

Despite its significant advantages as a baseload, low-carbon energy source, the U.S. nuclear power industry has faced increasing difficulties in maintaining economic competitiveness in a rapidly evolving energy market. The economic conditions faced by the current fleet of nuclear power plants (NPPs) in the U.S. deregulated electricity market require a concerted effort to mitigate specific cost factors. Many units are struggling to stay competitive, and some premature shutdowns have occurred. Besides, in response to the large penetration of renewable energy sources, the role of nuclear power plants as pure baseload units needs to be reconsidered. Based on these experiences, operational flexibility is considered a fundamental requirement for the next generation of nuclear reactors to be competitive in the future energy market. The deployment of advanced reactors capable of operating within a new power grid paradigm, known as the Integrated Energy System (IES) was investigated. This approach combines new reactor designs with Thermal Energy Storage (TES) technologies, allowing the nuclear reactor to maintain a steady power output without the need for constant adjustments in response to load demand fluctuations. With this configuration, the reactor operates as a baseload unit, experiencing only very gradual power transients, while the energy storage facility within the power conversion cycle acts as a peaking unit.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New Report Highlights LAMP's Role as a Robust and Reliable System for Wave Energy Converter Testing

Harnessing the power of waves requires more than just putting devices in the ocean - it takes tools that can refine and accelerate innovation before the first deployment. That's where NLR's largeamplitude motion platform, or LAMP, comes in. LAMP is a six-degree-of-freedom motion system designed to replicate the response of a wave energy converter (WEC) device in realistic ocean conditions. By letting researchers evaluate WEC performance in a safe, controlled lab environment before moving offshore, LAMP helps accelerate innovation while reducing risk. An NLR report, titled Initial Characterization of the NLR LargeAmplitude Motion Platform (https://www.nrel.gov/docs/fy26osti/93733.pdf), provides a deeper understanding of LAMP's capabilities and also lays the groundwork for future advancements in WEC testing methodologies. Researchers studied LAMP's amplitude and frequency limits across different payloads and collected data from 16 test profiles. Testing demonstrated that platform accuracy remained consistent across all payloads evaluated; researchers expect similar accuracy up to LAMP's 10,000-kilogram capacity limit. The measured position limits for single degrees of freedom experienced by WECs, including surge, sway, heave, roll, pitch, and yaw, also exceeded the original manufacturer specifications, providing new insight into the true boundaries of the system.

16 TIDAL AND WAVE POWER↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

Impacts of Spatial Resolution in a High-Fidelity Capacity Expansion Model: An ERCOT Case Study

Capacity expansion models are important tools in examining the evolution of the electric power sector. Embedded in these tools are many modeling choices with consequential impacts on computational burden and associated analysis. In this study, we adjust the spatial resolution of the Regional Energy Deployment System (ReEDS) to understand the implications of higher-fidelity modeling on energy system projections and model solve times. The native ReEDS regions capture the contiguous United States in 134 balancing areas whereas the regions in the higher-resolution version are defined by over 3,000 U.S. counties. Using both resolutions, we conduct a case study of the Texas Interconnection (The Electric Reliability Council of Texas [ERCOT]) to explore differences in model projections and to inform appropriate applications of high spatial resolution in a large-scale, applied capacity expansion model.

county↗

Preliminary Design of a Solar Photovoltaic Array for Net-Zero Energy Buildings at NASA Langley

An investigation was conducted to evaluate photovoltaic (solar electric systems) systems for a single building at NASA Langley as a representative case for alternative sustainable power generation. Building 1250 in the Science Directorate is comprised of office and laboratory space, and currently uses approximately 250,000 kW/month of electrical power with a projected use of 200,000 kW/month with additional conservation measures. The installation would be applied towards a goal for having Building 1250 classified as a net-zero energy building as it would produce as much energy as it uses over the course of a year. Based on the facility s electrical demand, a photovoltaic system and associated hardware were characterized to determine the optimal system, and understand the possible impacts from its deployment. The findings of this investigation reveal that the 1.9 MW photovoltaic electrical system provides favorable and robust results. The solar electric system should supply the needed sustainable power solution especially if operation and maintenance of the system will be considered a significant component of the system deployment.

Cole, Stuart K.↗

Methods identifying cost reduction potential for water electrolysis systems

The electrochemical reduction of water to form hydrogen is an emerging alternative for energy storage, where hydrogen can be used as a transportation fuel, combusted to generate electricity, utilized in a fuel cell, or used as a feedstock for chemical synthesis. Techno-economic analysis (TEA) is a valuable tool for understanding how to inform research directions that could make hydrogen from electrolysis cost competitive with that produced by conventional means like steam methane reforming. The current state of knowledge on TEA of electrolysis systems suggests cost reductions are likely to result from advances in system design and materials, scale-up of manufacturing processes, and learning by doing effects as electrolysis deployment increases. Future directions and opportunities for TEA of electrolysis systems include dispatchable operation in wholesale power markets, optimization of capital cost and system durability, and analysis of pathways for hydrogen to support economy-wide decarbonization.

08 HYDROGEN↗

Validation of Phasor-Domain Transmission and Distribution Co-simulation Against Electromagnetic Transient Simulation

The rapid deployment of renewable energy resources has led to the widespread use of power electronics in modern power systems. As these systems transition from being dominated by large synchronous machines to increasingly incorporating inverter-based resources (IBRs), traditional methods are becoming inadequate. Addressing this challenge, this paper introduces a scalable phasor-domain T\&D co-simulation framework based on open-source software. It focuses on the framework's validation against the PSCAD Electromagnetic Transient (EMT) analysis tool. The validation results demonstrate the framework's high-fidelity and a computational time speed-up of 60 to 100 times, marking a pioneering validation effort in T\&D co-simulation research.

Inverter-based resources, co-simulation, Electroma↗

Reimagining pH Measurement: Utilizing Raman Spectroscopy for Enhanced Accuracy in Phosphoric Acid Systems

Measurement of pH is an integral component of chemical studies and process control; however traditional pH probes are difficult to utilize in harsh or complex chemical systems. Optical spectroscopy-based on-line monitoring offers a powerful and novel route for characterizing system parameters, such as pH, and is well adapted to deployment in harsh environments or chemically complex systems. Specifically, Raman spectroscopy combined with chemometric analysis can provide an improved method of on-line pH measurement. Therefore, multivariate curve resolution analysis of Raman spectra can be utilized to determine speciation as a function of pH and subsequent chemometric modeling can be used to correlate spectral response to pH. This was demonstrated with phosphoric acid, a chemical system known to challenge traditional pH probes. Raman spectra exhibit clear changes with pH due to changing speciation, and chemometric modeling can be successfully utilized to correlate those fingerprints to pH. Using this approach, true pH of the phosphoric acid system can be measured with greater accuracy than with traditional pH probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potential for large-scale deployment of offshore wind-to-hydrogen systems in the United States

This study explores the role of producing low-carbon hydrogen using water electrolysis powered by offshore wind in facilitating the United States’ transition to a net-zero emissions economy by 2050. This research introduces an open-source scenario analysis tool for offshore wind-to-hydrogen systems, aiming to assess the impact of technology, regional considerations, and policy incentives on the cost of producing low-carbon hydrogen through offshore wind. Conducting a regional techno-economic analysis at four U.S. coastal sites, the study evaluates two energy transmission configurations and examines associated costs for the years 2025, 2030, and 2035. The results highlight that locations using fixed-bottom technology may achieve cost-competitive water electrolysis hydrogen production by 2030 through leveraging geologic hydrogen storage and federal policy incentives. Furthermore, floating technology locations are expected to see an average 38% reduction in the levelized cost of hydrogen from 2025 to 2035.

17 WIND ENERGY↗

Historical Comparison of Capacity Build Decisions from the Regional Energy Deployment System (ReEDS) Model

The Regional Energy Deploy System (ReEDS) capacity expansion model is frequently used to project the evolution of the U.S. power sector under a wide range of conditions. However, the model's capacity expansion decisions have never been evaluated against historical capacity expansion decisions. In this work, we perform a model validation exercise, comparing capacity expansion decision from ReEDS for 2010-2016 against the actual buildout of the electricity sector. We find that with three key adjustments ReEDS is able to reproduce national level results with reasonably high accuracy. Those three adjustments are to use historical average planning reserve margins instead of the NERC-recommended reserve margin levels, using actual financing costs rather than long-term average financing costs, and disallowing the lowest-cost hydropower upgrades, geothermal sites, and compress-air energy storage sites. We also compare the ReEDS results at a state-level and find that state-level results can be better represented by including a penalty for transferring power between regions. The improved results with that penalty indicate that the ReEDS transmission representation is likely not sufficiently stringent, and should be improved. Overall these results show that with the improvements described above, ReEDS can effectively reproduce historical capacity additions, which increases our confidence in using the model in making forward-looking projections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regional Energy Deployment System (ReEDS) Model Documentation: Version 2018

The Regional Energy Deployment System (ReEDS) model is a capacity expansion and dispatch model for the contiguous U.S. electric power sector that relies on system-wide least cost optimization to estimate the type and location of future generation and transmission capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗