Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the settings of the electronic system, such as the high voltage and the discrimination level in order to obtain all the characteristic curves of the detectors. These curves are used to define the right setting of the electronic system and to discuss the expected degradation of the detector signal resulting from the detector damage under the integrated neutron and gamma fluxes. Moreover, in addition to the study of the neutron detection systems itself, the integration of the measurements made by these detection systems in the logic of the safety system of the nuclear reactor is also addressed. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. In addition to on-reactor training, Internet Reactor Laboratory capability has been implemented on the ISIS reactor in 2014. For the Internet Reactor Laboratory an extensive video conference system has been implemented on ISIS reactor. The system includes 4 cameras and the transmission of the video signal given by the supervision system of the reactor which records and processes the data of the reactor. According to the pedagogic needs during the training courses, the lecturer on the ISIS reactor chooses to broadcast the relevant information at each stage of the course. For example, graph showing the histogram of the counting and current as a function of the time, or the electrical signal observed on the oscilloscope, can be broadcasted trough internet. By interacting through the video conference, the remote classroom is able to ask for changes in the reactor power or settings of the detection systems. They can also ask for the broadcast of some particular information. At the guest institution, the information is displayed in two parts or screens, as shown in the Figure 3. Concerning the interaction with - and the feedback from - the remote classroom, the camera of the video system in the remote classroom is used to ensure the contact between the trainees and the lecturer and reactor operators. Thus, the Internet Reactor Laboratory is complementary to the on reactor training courses. It allows distant learning, reducing the overall cost of the course when this is necessary. It can efficiently be used for the development of the human resources needed by the nuclear industry and the nuclear programs in countries without research reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Quantitative multiplex detection of biomarkers on a waveguide-based biosensor using quantum dots

The quantitative, simultaneous detection of multiple biomarkers with high sensitivity and specificity is critical for biomedical diagnostics, drug discovery and biomarker characterization [Wilson 2006, Tok 2006, Straub 2005, Joos 2002, Jani 2000]. Detection systems relying on optical signal transduction are, in general, advantageous because they are fast, portable, inexpensive, sensitive, and have the potential for multiplex detection of analytes of interest. However, conventional immunoassays for the detection of biomarkers, such as the Enzyme Linked Immunosorbant Assays (ELISAs) are semi-quantitative, time consuming and insensitive. ELISA assays are also limited by high non-specific binding, especially when used with complex biological samples such as serum and urine (REF). Organic fluorophores that are commonly used in such applications lack photostability and possess a narrow Stoke's shift that makes simultaneous detection of multiple fluorophores with a single excitation source difficult, thereby restricting their use in multiplex assays. The above limitations with traditional assay platforms have resulted in the increased use of nanotechnology-based tools and techniques in the fields of medical imaging [ref], targeted drug delivery [Caruthers 2007, Liu 2007], and sensing [ref]. One such area of increasing interest is the use of semiconductor quantum dots (QDs) for biomedical research and diagnostics [Gao and Cui 2004, Voura 2004, Michalet 2005, Chan 2002, Jaiswal 2004, Gao 2005, Medintz 2005, So 2006 2006, Wu 2003]. Compared to organic dyes, QDs provide several advantages for use in immunoassay platforms, including broad absorption bands with high extinction coefficients, narrow and symmetric emission bands with high quantum yields, high photostablility, and a large Stokes shift [Michalet 2005, Gu 2002]. These features prompted the use of QDs as probes in biodetection [Michalet 2005, Medintz 2005]. For example, Jaiswal et al. reported long term multiple color imaging of live cells using QD-bioconjugates [Jaiswal 2003]. Gao [Gao 2004] and So [So 2006] have used QDs as probes for in-vivo cancer targeting and imaging. Medintz et al. reported self-assembled QD-based biosensors for detection of analytes based on energy transfer [Medintz 2003]. Others have developed an approach for multiplex optical encoding of biomolecules using QDs [Han 2001]. Immunoassays have also benefited from the advantages of QDs. Recently, dihydrolipoic acid (DHLA) capped-QDs have been attached to antibodies and used as fluorescence reporters in plate-based multiplex immunoassays [Goodman 2004]. However, DHLA-QDs are associated with low quantum efficiency and are unstable at neutral pH. These problems limit the application of this technology to the sensitive detection of biomolecules, especially in complex biological samples. Thus, the development of a rapid, sensitive, quantitative, and specific multiplex platform for the detection of biomarkers in difficult samples remains an elusive target. The goal stated above has applications in many fields including medical diagnostics, biological research, and threat reduction. The current decade alone has seen the development of a need to rapidly and accurately detect potential biological warfare agents. For example, current methods for the detection of anthrax are grossly inadequate for a variety of reasons including long incubation time (5 days from time of exposure to onset of symptoms) and non-specific ('flu-like') symptoms. When five employees of the United State Senate were exposed to B. anthracis in the mail (2001), only one patient had a confirmed diagnosis before death. Since then, sandwich immunoassays using both colorimetric and fluorescence detectors have been developed for key components of the anthrax lethal toxin, namely protective antigen (PA), lethal factor (LF), and the edema factor [Mourez 2001]. While these platforms were successful in assays against anthrax toxins, the sensitivity was poor. Furthermore, no single platform exists for the simultaneous and quantitative detection of multiple components of the B. anthracis toxin. Addressing multiple biomarkers at the same time will increase confidence in a positive result, and may lead to application in the simultaneous detection of anthrax and other biowarfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral anomaly methods for aerial detection using KUT nuisance rejection

Aerial detection combines all the challenges of standoff detection with all the difficulties of mobile survey, including large and varying standoff distances and abrupt and significant changes in background. Critical issues for aerial detection include land-water interfaces, rapidly changing KUT backgrounds, and varying down scatter with altitude changes. To address these issues a spectral anomaly method has been adapted to aerial detection. The NSCRAD (Nuisance-Rejection Spectral Comparison Ratio) algorithm was initially developed at PNNL for medium resolution detectors. The algorithm has been used for a range of ground-based detection applications, including ground-based detection, portal monitoring, and OSI applications. The method used in NSCRAD includes both optimized energy windows for detection of threat sources and a nuisance rejection capability. Additionally, the spectral anomaly method was optimized in this work for aerial detection systems to increase the probability of detection of threat sources in aerial search while using the nuisance rejection capability to minimize false alarms from rapidly changing aerial background. The adaptation of NSCRAD for aerial detection includes re-optimization of energy windows, adapting KUT nuisance rejection for aerial backgrounds, development of new methods for background tracking and adjustment of tracking and detection thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

Automatic Detection and Classification of Radio Galaxy Images by Deep Learning

Abstract Surveys conducted by radio astronomy observatories, such as SKA, MeerKAT, Very Large Array, and ASKAP, have generated massive astronomical images containing radio galaxies (RGs). This generation of massive RG images has imposed strict requirements on the detection and classification of RGs and makes manual classification and detection increasingly difficult, even impossible. Rapid classification and detection of images of different types of RGs help astronomers make full use of the observed astronomical image data for further processing and analysis. The classification of FRI and FRII is relatively easy, and there are more studies and literature on them at present, but FR0 and FRI are similar, so it is difficult to distinguish them. It poses a greater challenge to image processing. At present, deep learning has made breakthrough progress in the field of image analysis and processing and has preliminary applications in astronomical data processing. Compared with classification algorithms that can only classify galaxies, object detection algorithms that can locate and classify RGs simultaneously are preferred. In target detection algorithms, YOLOv5 has outstanding advantages in the classification and positioning of small targets. Therefore, we propose a deep-learning method based on an improved YOLOv5 object detection model that makes full use of multisource data, combining FIRST radio with SDSS optical image data, and realizes the automatic detection of FR0, FRI, and FRII RGs. The innovation of our work is that on the basis of the original YOLOv5 object detection model, we introduce the SE Net attention mechanism, increase the number of preset anchors, adjust the network structure of the feature pyramid, and modify the network structure, thereby allowing our model to demonstrate galaxy classification and position detection effects. Our improved model produces satisfactory results, as evidenced by experiments. Overall, the mean average precision (mAP@0.5) of our improved model on the test set reaches 89.4%, which can determine the position (R.A. and decl.) and automatically detect and classify FR0s, FRIs, and FRIIs. Our work contributes to astronomy because it allows astronomers to locate FR0, FRI, and FRII galaxies in a relatively short time and can be further combined with other astronomically generated data to study the properties of these galaxies. The target detection model can also help astronomers find FR0s, FRIs, and FRIIs in future surveys and build a large-scale star RG catalog. Moreover, our work is also useful for the detection of other types of galaxies.

Astronomy & Astrophysics↗

SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photons per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201-14-1002) supervised by the NIPA (National IT Industry Promotion Agency). Authors declares that s/he has no conflict of Interest in relation to the work in this abstract.

60 APPLIED LIFE SCIENCES↗

TU-G-BRD-01: Quantifying the Effectiveness of the Physics Pre-Treatment Plan Review for Detecting Errors in Radiation Therapy

Purpose: Physics pre-treatment plan review is crucial to safe radiation oncology treatments. Studies show that most errors originate in treatment planning, which underscores the importance of physics plan review. As a QA measure the physics review is of fundamental importance and is central to the profession of medical physics. However, little is known about its effectiveness. More hard data are needed. The purpose of this study was to quantify the effectiveness of physics review with the goal of improving it. Methods: This study analyzed 315 “potentially serious” near-miss incidents within an institutional incident learning system collected over a two-year period. 139 of these originated prior to physics review and were found at the review or after. Incidents were classified as events that: 1)were detected by physics review, 2)could have been detected (but were not), and 3)could not have been detected. Category 1 and 2 events were classified by which specific check (within physics review) detected or could have detected the event. Results: Of the 139 analyzed events, 73/139 (53%) were detected or could have been detected by the physics review; although, 42/73 (58%) were not actually detected. 45/73 (62%) errors originated in treatment planning, making physics review the first step in the workflow that could detect the error. Two specific physics checks were particularly effective (combined effectiveness of >20%): verifying DRRs (8/73) and verifying isocenter (7/73). Software-based plan checking systems were evaluated and found to have potential effectiveness of 40%. Given current data structures, software implementations of some tests such as isocenter verification check would be challenging. Conclusion: Physics plan review is a key safety measure and can detect majority of reported events. However, a majority of events that potentially could have been detected were NOT detected in this study, indicating the need to improve the performance of physics review.

60 APPLIED LIFE SCIENCES↗

Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules using PET/CT images.

60 APPLIED LIFE SCIENCES↗

GEDet: Detecting Erroneous Nodes with A Few Examples

Detecting nodes with erroneous values in real-world graphs re- mains challenging due to the lack of examples and various error scenarios. We demonstrate GEDet, an error detection engine that can detect erroneous nodes in graphs with a few examples. The GEDet framework tackles error detection as a few-shot node classification problem. We invite the attendees to experience the following unique features. (1) Few-shot detection. Users only need to provide a few examples of erroneous nodes to perform error detection with GEDet. GEDet achieves desirable accuracy with (a) a graph augmentation module, which automatically generates synthetic examples to learn the classifier, and (b) an adversarial detection module, which improves classifiers to better distinguish erroneous nodes from both cleaned nodes and synthetic examples. We show that GEDet significantly improves the state-of-the-art error detection methods. (2) Diverse error scenarios. GEDet profiles data errors with a built-in library of transformation functions from correct values to errors. Users can also easily “plug in” new error types or examples. (3) User-centric detection. GEDet supports (a) an active learning mode to engage users to verify detected results, and adapts the error detection process accordingly; and (b) visual interfaces to interpret and track detected errors.

Guan, Sheng↗

SISGR: Room Temperature Single-Molecule Detection and Imaging by Stimulated Emission Microscopy

Single-molecule spectroscopy has made considerable impact on many disciplines including chemistry, physics, and biology. To date, most single-molecule spectroscopy work is accomplished by detecting fluorescence. On the other hand, many naturally occurring chromophores, such as retinal, hemoglobin and cytochromes, do not have detectable fluorescence. There is an emerging need for single-molecule spectroscopy techniques that do not require fluorescence. In the last proposal period, we have successfully demonstrated stimulated emission microscopy, single molecule absorption, and stimulated Raman microscopy based on a high-frequency modulation transfer technique. These first-of-a- kind new spectroscopy/microscopy methods tremendously improved our ability to observe molecules that fluorescence weakly, even to the limit of single molecule detection for absorption measurement. All of these methods employ two laser beams: one (pump beam) excites a single molecule to a real or virtual excited state, and the other (probe beam) monitors the absorption/emission property of the single. We extract the intensity change of the probe beam with high sensitivity by implementing a high-frequency phase-sensitive detection scheme, which offers orders of magnitude improvement in detection sensitivity over direct absorption/emission measurement. However, single molecule detection based on fluorescence or absorption is fundamentally limited due to their broad spectral response. It is important to explore other avenues in single molecule detection and imaging which provides higher molecular specificity for studying a wide variety of heterogeneous chemical and biological systems. This proposal aimed to achieve single-molecule detection sensitivity with near resonance stimulated Raman scattering (SRS) microscopy. SRS microscopy was developed in our lab as a powerful technique for imaging heterogeneous samples based on their intrinsic vibrational contrasts, which provides much higher molecular specificity than absorption and fluorescence. Current sensitivity limit of SRS microscopy has not yet reached single molecule detection. We proposed to capitalize on our state-of-the-art SRS microscopy and develop near-resonance enhanced SRS for single molecule detection of carotenoids and heme proteins. The specific aims we pursued are: (1) building the next SRS generation microscope that utilizes near resonance enhancement to allow detection and imaging of single molecules with undetectable fluorescence, such as -carotene. (2) using near-resonance SRS as a contrast mechanism to study dye-sensitize semiconductor interface, elucidating the heterogeneous electron ejection kinetics with high spatial and temporal resolution. (3) studying the binding and unbinding of oxygen in single hemoglobin molecules in order to gain molecular level understanding of the long-standing issue of cooperativity. The new methods developed in the fund period of this grant have advanced the detection sensitivity in many aspects. Near-resonance SRS improved the signal by using shorter wavelengths for SRS microscopy. Frequency modulation and multi-color SRS target the reduction of background to improve the chemical specificity of SRS while maintaining the high imaging speed. Time-domain coherent Raman scattering microscopy targets to reduce the noise floor of coherent Raman microscopy. These methods have already demonstrated first-of-a-kind new applications in biology and medical research. However, we are still one order of magnitude away from single molecule limit. It is important to continue to improve the laser specification and develop new imaging methods to finally achieve label-free single molecule microscopy.

47 OTHER INSTRUMENTATION↗

Coherent Detection of High-Rate Optical PPM Signals

A method of coherent detection of high-rate pulse-position modulation (PPM) on a received laser beam has been conceived as a means of reducing the deleterious effects of noise and atmospheric turbulence in free-space optical communication using focal-plane detector array technologies. In comparison with a receiver based on direct detection of the intensity modulation of a PPM signal, a receiver based on the present method of coherent detection performs well at much higher background levels. In principle, the coherent-detection receiver can exhibit quantum-limited performance despite atmospheric turbulence. The key components of such a receiver include standard receiver optics, a laser that serves as a local oscillator, a focal-plane array of photodetectors, and a signal-processing and data-acquisition assembly needed to sample the focal-plane fields and reconstruct the pulsed signal prior to detection. The received PPM-modulated laser beam and the local-oscillator beam are focused onto the photodetector array, where they are mixed in the detection process. The two lasers are of the same or nearly the same frequency. If the two lasers are of different frequencies, then the coherent detection process is characterized as heterodyne and, using traditional heterodyne-detection terminology, the difference between the two laser frequencies is denoted the intermediate frequency (IF). If the two laser beams are of the same frequency and remain aligned in phase, then the coherent detection process is characterized as homodyne (essentially, heterodyne detection at zero IF). As a result of the inherent squaring operation of each photodetector, the output current includes an IF component that contains the signal modulation. The amplitude of the IF component is proportional to the product of the local-oscillator signal amplitude and the PPM signal amplitude. Hence, by using a sufficiently strong local-oscillator signal, one can make the PPM-modulated IF signal strong enough to overcome thermal noise in the receiver circuits: this is what makes it possible to achieve near-quantum-limited detection in the presence of strong background. Following quantum-limited coherent detection, the outputs of the individual photodetectors are automatically aligned in phase by use of one or more adaptive array compensation algorithms [e.g., the least-mean-square (LMS) algorithm]. Then the outputs are combined and the resulting signal is processed to extract the high-rate information, as though the PPM signal were received by a single photodetector. In a continuing series of experiments to test this method (see Fig. 1), the local oscillator has a wavelength of 1,064 nm, and another laser is used as a signal transmitter at a slightly different wavelength to establish an IF of about 6 MHz. There are 16 photodetectors in a 4 4 focal-plane array; the detector outputs are digitized at a sampling rate of 25 MHz, and the signals in digital form are combined by use of the LMS algorithm. Convergence of the adaptive combining algorithm in the presence of simulated atmospheric turbulence for optical PPM signals has already been demonstrated in the laboratory; the combined output is shown in Fig. 2(a), and Fig. 2(b) shows the behavior of the phase of the combining weights as a function of time (or samples). We observe that the phase of the weights has a sawtooth shape due to the continuously changing phase in the down-converted output, which is not exactly at zero frequency. Detailed performance analysis of this coherent free-space optical communication system in the presence of simulated atmospheric turbulence is currently under way.

Vilnrotter, Victor↗

Securing Special Nuclear Material: Recent Advances in Neutron Detection and Their Role in Nonproliferation

Neutron detection is an integral part of the global effort to prevent the proliferation of special nuclear material (SNM). Applications relying on neutron-detection technology range from traditional nuclear non-proliferation objectives, such as safeguarding nuclear material and verifying stockpile reductions, to the interdiction of SNM—a goal that has recently risen in priority to a level on par with traditional applications. Large multi-national programs targeting detection and safeguards have deployed radiation-detection assets across the globe. Alongside these deployments of commercially available technology, significant research and development efforts have been directed towards the creation of next-generation assets. While much of this development has focused on gamma-ray spectrometers, neutron-detection technology remains an important component of the global strategy because of the capability of neutrons to penetrate materials that readily absorb gamma rays and the unique multiplicity signatures offered by neutrons. One particularly acute technology-development challenge results from dwindling supplies of 3He, partially triggered by widespread deployment of high-efficiency systems for portal monitoring. Other emerging missions, such as the desire to detect SNM at greater standoff distances, have also stimulated neutron-detection technology development. In light of these needs for novel neutron-detection technologies, this manuscript reviews the signatures of neutrons emitted by SNM, the principles of neutron detection, and various strategies under investigation for detection in the context of nonproliferation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DETECTION OF POTENTIAL TRANSIT SIGNALS IN THE FIRST THREE QUARTERS OF Kepler MISSION DATA

We present the results of a search for potential transit signals in the first three quarters of photometry data acquired by the Kepler mission. The targets of the search include 151,722 stars which were observed over the full interval and an additional 19,132 stars which were observed for only one or two quarters. From this set of targets we find a total of 5392 detections which meet the Kepler detection criteria: those criteria are periodicity of signal, an acceptable signal-to-noise ratio, and a composition test which rejects spurious detections which contain non-physical combinations of events. The detected signals are dominated by events with relatively low signal-to-noise ratio and by events with relatively short periods. The distribution of estimated transit depths appears to peak in the range between 40 and 100 parts per million, with a few detections down to fewer than 10 parts per million. The detections exhibit signal-to-noise ratios from 7.1{sigma}, which is the lower cutoff for detections, to over 10,000{sigma}, and periods ranging from 0.5 days, which is the lower cutoff used in the procedure, to 109 days, which is the upper limit of achievable periods given the length of the data set and the criteria used for detections. The detected signals are compared to a set of known transit events in the Kepler field of view which were derived by a different method using a longer data interval; the comparison shows that the current search correctly identified 88.1% of the known events. A tabulation of the detected transit signals, examples which illustrate the analysis and detection process, a discussion of future plans and open, potentially fruitful, areas of further research are included.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Periodic Forced Oscillations in Power Systems

An algorithm for the detection and frequency estimation of forced oscillations in power systems is proposed. The method operates by comparing the periodogram of synchrophasor measurements to a detection threshold. This threshold is established by deriving a general expression for the distribution of the periodogram and is related to the algorithm's probabilities of false alarm and detection. Unlike classic detection algorithms designed for use with white Gaussian noise, the proposed algorithm uses a detection threshold that varies with frequency to account for the colored nature of synchrophasor measurements. Further, a detection scheme based on multiple segments of data is proposed to improve the algorithm's performance as a monitoring tool in the online environment. A design approach that helps to ensure that the best-available probability of detection from any one detection segment is constantly increasing with the duration of the forced oscillation is also developed. Results from application of the detection algorithm to simulated and measured power system data suggest that the algorithm provides the expected detection performance and can be used to detect forced oscillations in practical monitoring of power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the Effectiveness of Generalized Likelihood Ratio Test Detector Schemes in Seismic Event Detection and the Avoidance of Nontarget Signals

Cross-correlation techniques have played a long-standing and pivotal role in seismic event monitoring. However, the performance of correlation-based detectors is challenged by nuisance seismicity, or nontarget signals. Such detections are a problem when the mission is to automatically map events to the correct source region. Using aftershocks of the 2014 $M_w$ 6.0 South Napa, California, earthquake, we demonstrate the effectiveness of utilizing a dynamic correlation processor framework in a generalized likelihood ratio test (GLRT) detector configuration to minimize nontarget detections. A GLRT maximizes a detection statistic with respect to one or more unknown parameters. In this case, the detection statistic is a template signal match against the waveform in a window sliding over a data stream, and the unknown parameter is an index variable indicating group membership of the template event or events. Detected events are assigned to the event group that yields the largest detection statistic. In this work, our results show that a GLRT detector will outperform a suite of independently operating correlation and subspace detectors in terms of having a lower nontarget detection rate at a given missed detection rate. We also show that a GLRT detector composed of a few high-rank subspace detectors has a slightly higher nontarget detection rate, but a significantly lower missed detection rate, than a GLRT detector composed of many low-rank subspace detectors. The high-rank GLRT configuration produced impressive results even with marginal data (single channel, single station, and very low time bandwidth product), which bodes well for the utility of building efficient aftershock classification systems and global monitoring systems at larger scales. However, future work is required to assess performance at the regional scale and to assess the performance of the system at detecting target events not used in the detector template creation.

58 GEOSCIENCES↗

Improving radiograph analysis throughput through transfer learning and object detection

SIGN Fracture Care International partners with surgeons in low-resource hospitals worldwide to provide access to effective orthopedic care by donating educational materials and innovatively designed surgical implants. Over two decades, SIGN’s Online Surgical Database (SOSD) has grown to contain over 500,000 medical images, with radiographs holding the majority share. One challenge in working with hospitals worldwide is that both the radiographs uploaded to the SOSD and the data entry accompanying the uploads vary in quality. To improve the accuracy of data in the SOSD, we trained a model to detect surgical implants in radiographs. We first developed a tool to automatically detect radiographs, then trained an object detection model to determine the number and placement of surgical implants visible in the radiograph. Active learning was used to generate a training set containing 2,510 radiographs with screws, nails, and plates labeled by bounding boxes. Training a model to simultaneously recognize all three classes of implants gave a low average precision (AP) for the plate class, likely due to the low number of plate instances in our training set and the large variety of surgical plates used by SIGN-partnered surgeons. Applying standard image augmentation techniques to increase the plate count in our training set did not appreciably increase the AP of plate detection. To improve plate detection, we redrew the bounding boxes to account for correlations between the screw and plate classes. Training one model to detect nails and screws and a separate model to detect plates increased the AP of plate detection by 78.8 percentage points. The AP of each class was 80.7% for screws, 93.6% for nails, and 92.6% for plates; meanwhile, the sensitivity was 92% for screws, 86% for nails, and 81% for plates. We show that object detection methods can be used to detect surgical implants in radiographs of varying quality; however, the detection ability is dependent on the type of implant, and some implants, in our case plates, must be treated differently than others. Such tools can improve the throughput of radiograph analysis, assisting physicians and surgeons with the treatment of bone fractures.

60 APPLIED LIFE SCIENCES↗

Aerial Neutron Detection: Neutron Signatures for Nonproliferation and Emergency Response Applications

From 2007 to the present, the Remote Sensing Laboratory has been conducting a series of studies designed to expand our fundamental understanding of aerial neutron detection with the goal of designing an enhanced sensitivity detection system for long range neutron detection. Over 35 hours of aerial measurements in a helicopter were conducted for a variety of neutron emitters such as neutron point sources, a commercial nuclear power reactor, nuclear reactor spent fuel in dry cask storage, depleted uranium hexafluoride and depleted uranium metal. The goals of the project were to increase the detection sensitivity of our instruments such that a 5.4 × 104 neutron/second source could be detected at 100 feet above ground level at a speed of 70 knots and to enhance the long-range detection sensitivity for larger neutron sources, i.e., detection ranges above 1000 feet. In order to increase the sensitivity of aerial neutron detection instruments, it is important to understand the dynamics of the neutron background as a function of altitude. For aerial neutron detection, studies have shown that the neutron background primarily originates from above the aircraft, being produced in the upper atmosphere by galactic cosmic-ray interactions with air molecules. These interactions produce energetic neutrons and charged particles that cascade to the earth’s surface, producing additional neutrons in secondary collisions. Hence, the neutron background increases as a function of altitude which is an impediment to long-range neutron detection. In order to increase the sensitivity for long range detection, it is necessary to maintain a low neutron background as a function of altitude. Initial investigations show the variation in the neutron background can be decreased with the application of a cosmic-ray shield. The results of the studies along with a representative data set are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗