Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Five-degrees-of-freedom diffractive laser encoder

Linear laser encoders have been widely used for precision positioning control of a linear stage. We develop a five-degrees-of-freedom (5-DOF) laser linear encoder to simultaneously measure the position, straightness, pitch, roll, and yaw errors along one moving axis. This study integrates the circular polarized interferometric technique with the three-dimensional diffracted ray-tracing method to develop a novel laser encoder with 5-DOF. The phases encoded within the +1 and -1 order diffraction lights reflected from the diffraction grating are decoded by the circular polarized interferometric technique to measure the linear displacement when the diffraction grating moves. The three-dimensional diffracted ray tracing of the +1- and -1-order diffraction lights induced by the motion errors of the moved grating were analyzed to calculate the other motion errors based on the detection of light spots on two quadrant photodiode detectors. The period of the grating is 0.83 {mu}m and the experimental results show that the measurement accuracy was better than {+-}0.3 {mu}m/{+-}41 {mu}m for straightness, {+-}1 arc sec.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emerging Beam Resonances in Atom Diffraction from a Reflection Grating

We report on the observation of emerging beam resonances, well known as Rayleigh-Wood anomalies and threshold resonances in photon and electron diffraction, respectively, in an atom-optical diffraction experiment. Diffraction of He atom beams reflected from a blazed ruled grating at grazing incidence has been investigated. The total reflectivity of the grating as well as the intensities of the diffracted beams reveal anomalies at the Rayleigh angles of incidence, i.e., when another diffracted beam emerges parallel to the grating surface. The observed anomalies are discussed in terms of the classical wave-optical model of Rayleigh and Fano.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of Yttrium Oxide Nanoparticles on the Diffraction Efficiency of Holographic Polymer-liquid Crystal Gratings

Electro-optical properties of the holographic and polarization holographic diffraction gratings formed in polymer-liquid crystal composites doped with Y{sub 2}O{sub 3} nanoparticles are considered. The effect of impurities on the diffraction efficiency and operated electric field is shown. The diffraction efficiency of doped holographic diffraction gratings decreases, whereas the diffraction efficiency of polarization diffraction gratings increases. Doping with nanoparticles leads to a decrease in the operated electric field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transmission Kikuchi diffraction and transmission electron forescatter imaging of electropolished and FIB manufactured TEM specimens

We present a study of the efficiency of the utility of scanning electron microscope (SEM)-based transmission methods for characterizing grain structure in thinned bulk metals. Foils of type 316 stainless steel were prepared by two methods commonly used for transmission electron microscopy — double-jet electropolishing and focused ion beam milling. A customized holder allowed positioning of the foils in a configuration appropriate for both transmission electron forward scatter diffraction, and for transmission imaging by the use of a forescatter detector with two diodes. We found that both crystallographic orientation maps and dark-field transmitted images could be obtained for specimens prepared by either method. However, for both methods, preparation-induced artifacts may affect the quality or accuracy of transmission SEM data, especially those acquired by the use of transmission Kikuchi diffraction. Generally, the quality of orientation data was better for specimens prepared by electropolishing, due to the absence of ion-induced damage. - Highlights: • The transmission imaging and diffraction techniques are emerging in scanning electron microscopy (SEM) as promising new field of materials characterization. • The manuscript titled: “Transmission Kikuchi Diffraction and Transmission Electron Forescatter Imaging of Electropolished and FIB Manufactured TEM Specimens” documents how different specimen thinning procedures can effect efficiency of transmission Kikuchi diffraction and transmission electron forescatter imaging. • The abilities to make precision crystallographic orientation maps and dark-field images in transmission was studied on electropolished versus focus ion beam manufactured TEM specimens. • Depending on the need, electropolished and focused ion beam technique may produce suitable specimens for transmission imaging and diffraction in SEM.

36 MATERIALS SCIENCE↗

Synchrotron X-ray diffraction analysis of constituent phases in transition joint between nickel alloy 738LC and a MnFeCoNiCu alloy

Synchrotron x-ray diffraction (XRD) analysis was performed on transition joints between a single-phase MnFeCoNiCu alloy and Ni-base Alloy 738LC to efficiently identify the constituent phases across the interface, with different levels of material intermixing generated by laser-welding with variable power. Here, the intermixing extent was quantified by postmortem energy dispersive x-ray spectroscopy mapping. Diffraction-based analyses on complex composition spaces with limited prior data present significant challenges because elemental substitution in both disordered and ordered phases is more extensive than in conventional alloy spaces, which may effectuate relatively large shifts in the observed lattice parameters that convolute the analysis. Therefore, thermodynamic simulations and crystallographic literature data were employed to construct a system-specific diffraction library of twelve prospective phases for the composition space investigated. Subsequently, for predicted disordered cubic phases, statistical hard-sphere models were established to estimate the lattice parameters and predict diffraction peak positions for inclusion in the library. The library was then employed to analyze diffraction profiles measured from the variably intermixed transition joints, with focus on accounting for both high and low-intensity peaks. 99.0 % of diffraction peaks with relative intensity greater than 0.001 were assigned to phases from the system-specific library, exemplifying rigorous peak accounting and indicating that no unexpected phases were present. Up to six of the twelve library phases were experimentally found in the transition joints. The lattice parameters predicted by the statistical hard-sphere model based upon thermodynamic simulations agree reasonably well with the measured values for the disordered FCC matrix phase.

36 MATERIALS SCIENCE↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-driven analysis of neutron diffraction line profiles: application to plastically deformed Ta

Abstract Non-destructive evaluation of plastically deformed metals, particularly diffraction line profile analysis (DLPA), is valuable both to estimate dislocation densities and arrangements and to validate microstructure-aware constitutive models. To date, the interpretation of whole line diffraction profiles relies on the use of semi-analytical models such as the extended convolutional multiple whole profile (eCMWP) method. This study introduces and validates two data-driven DLPA models to extract dislocation densities from experimentally gathered whole line diffraction profiles. Using two distinct virtual diffraction models accounting for both strain and instrument induced broadening, a database of virtual diffraction whole line profiles of Ta single crystals is generated using discrete dislocation dynamics. The databases are mined to create Gaussian process regression-based surrogate models, allowing dislocation densities to be extracted from experimental profiles. The method is validated against 11 experimentally gathered whole line diffraction profiles from plastically deformed Ta polycrystals. The newly proposed model predicts dislocation densities consistent with estimates from eCMWP. Advantageously, this data driven LPA model can distinguish broadening originating from the instrument and from the dislocation content even at low dislocation densities. Finally, the data-driven model is used to explore the effect of heterogeneous dislocation densities in microstructures containing grains, which may lead to more accurate data-driven predictions of dislocation density in plastically deformed polycrystals.

36 MATERIALS SCIENCE↗

Optical devices combining an organic semiconductor crystal with a two-dimensional inorganic diffraction grating

We have fabricated optical devices using an organic semiconductor crystal as an emission layer in combination with a two-dimensional (2D) inorganic diffraction grating used as an optical cavity. We formed the inorganic diffraction grating by wet etching of aluminum-doped zinc oxide (AZO) under a 2D cyclic olefin copolymer (COC) diffraction grating used as a mask. The COC diffraction grating was fabricated by nanoimprint lithography. The AZO diffraction grating was composed of convex prominences arranged in a triangular lattice. The organic crystal placed on the AZO diffraction grating indicated narrowed peaks in its emission spectrum under ultraviolet light excitation. These are detected parallel to the crystal plane. The peaks were shifted by rotating the optical devices around the normal to the crystal plane, which reflected the rotational symmetries of the triangular lattice through 60°.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of a particular class of integrals in the theory of diffraction

A particular class of integrals appearing in the problems of diffraction is treated in this paper. For the analysis of the classical sources or lasers, Kirchhoff’s integral can be used only for apertures of a determined shape. So far, the problems are solved and analyzed completely, whenever the geomtry of apertures creates the possibility of using Kirchhoff’s integral, namely for the so-called geometry of rectangular apertures. Other apertures exist for which Kirchhoff’s integral cannot be applied, because of difficulties of mathematical character. In this group of apertures belong all the apertures which are bounded with an inclined line, such as those with triangular form. In this paper, the application of a particular class of integrals is shown to give satisfying results in two problems of diffraction theory: double-diffraction phenomena consisting on separating the interferential-diffractional field from the diffractional field, and the case of near-zone of diffraction in the triangular aperture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TAKASAGO-6 apparatus for cryogenic coherent X-ray diffraction imaging of biological non-crystalline particles using X-ray free electron laser at SACLA

Coherent X-ray diffraction imaging (CXDI) is a technique for structure analyses of non-crystalline particles with dimensions ranging from micrometer to sub-micrometer. We have developed a diffraction apparatus named TAKASAGO-6 for use in single-shot CXDI experiments of frozen-hydrated non-crystalline biological particles at cryogenic temperature with X-ray free electron laser pulses provided at a repetition rate of 30 Hz from the SPring-8 Angstrom Compact free-electron LAser. Specimen particles are flash-cooled after being dispersed on thin membranes supported by specially designed disks. The apparatus is equipped with a high-speed translation stage with a cryogenic pot for raster-scanning of the disks at a speed higher than 25 μm/33 ms. In addition, we use devices assisting the easy transfer of cooled specimens from liquid-nitrogen storages to the cryogenic pot. In the current experimental procedure, more than 20 000 diffraction patterns can be collected within 1 h. Here we report the key components and performance of the diffraction apparatus. Based on the efficiency of the diffraction data collection and the structure analyses of metal particles, biological cells, and cellular organelles, we discuss the future application of this diffraction apparatus for structure analyses of biological specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray diffraction strains in laser-ablated aluminum, nickel, sodium, and invar: Pressures to 475 GPa

Dynamically compressed materials in longitudinal waves are described by two physical models: hydrostatic pressure, with equal, normal, principal stresses or material uniaxially strained in the wave propagation direction. These models are disparate, so experimental comparisons and evaluations are important. Polycrystalline material in a state of hydrostatic pressure will have no eccentricity of x-ray-diffracted Debye–Scherrer rings. A general three-dimensional solution of Bragg diffracted x rays based on principal crystallographic strains in the compression wave was found. The distortion of x-ray diffraction beams has been used for strain measurements; the analysis developed incorporates a strained reciprocal lattice and the incident x-ray beam. Strain-distorted Polanyi surfaces form an annulus of compression with an ellipsoid of revolution in reciprocal space, which is intersected by Ewald's sphere for Bragg diffraction. The in situ measurements for strain describe nanosecond diffraction evaluated using two planes, (hkl) and (h′k′l′), both in the same crystallographic phase. Diffraction from Al, Ni, Na, and Invar quantifies the compression axial strains in these materials: The compression axial ratios are 0.65, 1.05, 0.88, and 1.58 at pressures of 291, 402, 409, and 367 GPa for the respective materials. Crystal structure transformations with homogeneous pressurized stresses, mandating equal normal strains, should not be anticipated to agree with heterogeneous, uniaxially strained, and sheared crystalline phases. Measurements support in-plane strains increasing with pressure, p , in fcc and hcp aluminum as ε 22 = −0.21 p /TPa.

Alloys↗

Combined computed tomography and position-resolved X-ray diffraction of an intact Roman-era Egyptian portrait mummy

Hawara Portrait Mummy 4, a Roman-era Egyptian portrait mummy, was studied with computed tomography (CT) and with CT-guided synchrotron X-ray diffraction mapping. These are the first X-ray diffraction results obtained non-invasively from objects within a mummy. The CT data showed human remains of a 5-year-old child, consistent with the female (but not the age) depicted on the portrait. Physical trauma was not evident in the skeleton. Diffraction at two different mummy-to-detector separations allowed volumetric mapping of features including wires and inclusions within the wrappings and the skull and femora. Additionally, the largest uncertainty in origin determination was approximately 1.5 mm along the X-ray beam direction, and diffraction- and CT-determined positions matched. Diffraction showed that the wires were a modern dual-phase steel and showed that the 7 × 5 × 3 mm inclusion ventral of the abdomen was calcite. Tracing the 00.2 and 00.4 carbonated apatite (bone's crystalline phase) reflections back to their origins produced cross-sectional maps of the skull and of femora; these maps agreed with transverse CT slices within approximately 1 mm. Coupling CT and position-resolved X-ray diffraction, therefore, offers considerable promise for non-invasive studies of mummies.

60 APPLIED LIFE SCIENCES↗

One-dimensional neutron diffraction from layered graphite: Reciprocal space structure and grating behavior

In this work we report observations of one-dimensional neutron diffraction from highly oriented pyrolytic graphite (HOPG), where the scattering angle varies continuously with incident angle following classical grating-like behavior. The 2D polycrystalline structure of HOPG—with highly aligned layers along the 𝑐 axis but random in-plane rotations—creates planes of scattering intensity in reciprocal space at 𝑄 𝑐 =𝑛⁢(2⁢𝜋/𝑑) where 𝑑=3.35Å is the interlayer spacing. As the Ewald sphere sweeps through reciprocal space during sample rotation, it continuously intersects these planes, producing the observed angular dispersion. We observe both first-order (𝑛=1) and second-order (𝑛=2) diffraction at conventional scattering angles (25°–70°), with peak positions that remain temperature-independent between 10 K and 294 K and follow quantitative agreement with momentum conservation 𝑄 𝑐 =𝑘⁢[sin⁡𝜓−sin⁡𝜓 𝑓 ]=𝑛⁢(2⁢𝜋/𝑑). X-ray diffraction under similar conditions shows no comparable behavior, confirming that sharp nuclear-vacuum contrast is essential. While diffraction intensities are weak (∼10 −6 of Bragg peaks), the observations demonstrate how the interplay of atomic-scale periodicity, nuclear contrast, and structural disorder enables observation of continuous diffraction curves at thermal neutron wavelengths, illustrating how HOPG's unique microstructure determines its scattering properties beyond conventional Bragg diffraction.

2-dimensional systems↗

A Rietveld refinement method for angular- and wavelength-dispersive neutron time-of-flight powder diffraction data

This paper introduces a two-dimensional extension of the well established Rietveld refinement method for modeling neutron time-of-flight powder diffraction data. The novel approach takes into account the variation of two parameters, diffraction angle 2θ and wavelength λ, to optimally adapt to the varying resolution function in diffraction experiments. By doing so, the refinement against angular- and wavelength-dispersive data gets rid of common data-reduction steps and also avoids the loss of high-resolution information typically introduced by integration. In a case study using a numerically simulated diffraction pattern of Rh 0.81 Fe 3.19 N taking into account the layout of the future POWTEX instrument, the profile function as parameterized in 2θ and λ is extracted. As a proof-of-concept, the resulting instrument parameterization is then utilized to perform a typical refinement of the angular- and wavelength-dispersive diffraction pattern of CuNCN, yielding excellent residuals within feasible computational efforts. Another proof-of-concept is carried out by applying the same approach to a real neutron diffraction data set of CuNCN obtained from the POWGEN instrument at the Spallation Neutron Source in Oak Ridge. The paper highlights the general importance of the novel approach for data analysis at neutron time-of-flight diffractometers and its possible inclusion within existing Rietveld software packages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precision lattice parameter determination from transmission diffraction of thick specimens with irregular cross sections

Accurate determination of lattice parameters from X-ray diffraction requires that the diffraction angles be measured very precisely, and significant errors result if the sample–detector separation differs from that assumed. Transmission diffraction from bones, which have a complex cross section and must be left intact, is a situation where this separation is difficult to measure and it may differ from position to position across the specimen. Here, this article describes a method for eliminating the effect of variable sample cross section. Diffraction patterns for each position on the specimen are collected before and after 180° rotation about an axis normal to the cross section of interest. This places the centroid of the diffracting mass at the center of rotation and provides the absolute lattice parameters from the average apparent lattice parameters at the two rotation angles. Diffraction patterns were collected across the cross section of three specimens: a 3D-printed elliptical cylinder of Hyperelastic Bone (HB), which is composed primarily of synthetic hydroxyapatite (hAp), a 3D-printed HB model of the second metacarpal bone (Mc2), and a modern human Mc2 containing nanocrystalline carbonated apatite (cAp). Rietveld refinement was used to determine precise unit-cell parameters a apparent and c apparent for each pattern of each scan, and these values determined the actual average < a > and < c > for each sample. In conclusion, the results indicate that the 0°/180° rotation method works well enough to uncover variations approaching 1 × 10 -3 Å in cAp unit-cell parameters in intact bones with irregular cross sections.

36 MATERIALS SCIENCE↗

HiSPoD : a program for high-speed polychromatic X-ray diffraction experiments and data analysis on polycrystalline samples

Here, a high-speed X-ray diffraction technique was recently developed at the 32-ID-B beamline of the Advanced Photon Source for studying highly dynamic, yet non-repeatable and irreversible, materials processes. In experiments, the microstructure evolution in a single material event is probed by recording a series of diffraction patterns with extremely short exposure time and high frame rate. Owing to the limited flux in a short pulse and the polychromatic nature of the incident X-rays, analysis of the diffraction data is challenging. Here, HiSPoD , a stand-alone Matlab-based software for analyzing the polychromatic X-ray diffraction data from polycrystalline samples, is described. With HiSPoD , researchers are able to perform diffraction peak indexing, extraction of one-dimensional intensity profiles by integrating a two-dimensional diffraction pattern, and, more importantly, quantitative numerical simulations to obtain precise sample structure information.

36 MATERIALS SCIENCE↗

A new theory for X-ray diffraction

By considering the scattering distributed throughout space, there is an intensity enhancement at the Bragg angle even when the Bragg condition is not satisfied. This leads to an alternative explanation for the diffraction from powders and small crystals. This article proposes a new theory of X-ray scattering that has particular relevance to powder diffraction. The underlying concept of this theory is that the scattering from a crystal or crystallite is distributed throughout space: this leads to the effect that enhanced scatter can be observed at the ‘Bragg position’ even if the ‘Bragg condition’ is not satisfied. The scatter from a single crystal or crystallite, in any fixed orientation, has the fascinating property of contributing simultaneously to many ‘Bragg positions’. It also explains why diffraction peaks are obtained from samples with very few crystallites, which cannot be explained with the conventional theory. The intensity ratios for an Si powder sample are predicted with greater accuracy and the temperature factors are more realistic. Another consequence is that this new theory predicts a reliability in the intensity measurements which agrees much more closely with experimental observations compared to conventional theory that is based on ‘Bragg-type’ scatter. The role of dynamical effects (extinction etc.) is discussed and how they are suppressed with diffuse scattering. An alternative explanation for the Lorentz factor is presented that is more general and based on the capture volume in diffraction space. This theory, when applied to the scattering from powders, will evaluate the full scattering profile, including peak widths and the ‘background’. The theory should provide an increased understanding of the reliability of powder diffraction measurements, and may also have wider implications for the analysis of powder diffraction data, by increasing the accuracy of intensities predicted from structural models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detector Tilt Considerations in Bragg Coherent Diffraction Imaging: A Simulation Study

This paper addresses the three-dimensional signal distortion and image reconstruction issues in X-ray Bragg coherent diffraction imaging (BCDI) in the event of a general non-orthogonal orientation of the area detector with respect to the diffracted beam. Growing interest in novel BCDI adaptations at fourth-generation synchrotron light sources has necessitated improvisations in the experimental configuration and the subsequent data analysis. One such possibly unavoidable improvisation that is envisioned in this paper is a photon-counting area detector whose face is tilted away from the perpendicular to the Bragg-diffracted beam during the acquisition of the coherent diffraction signal. We describe a likely circumstance in which one would require such a detector configuration, along with the experimental precedent at third-generation synchrotrons. Using physically accurate diffraction simulations from synthetic scatterers in the presence of such tilted detectors, we analyze the general nature of the observed signal distortion qualitatively and quantitatively and provide a prescription to correct for it during image reconstruction. Our simulations and reconstructions are based on an adaptation of the known theory of BCDI sampling geometry, as well as the recently developed projection-based methods of wavefield propagation. Such configurational modifications and their numerical remedies are potentially valuable in realizing unconventional coherent diffraction measurement geometries, eventually paving the way for the integration of BCDI into new material characterization experiments at next-generation light sources.

36 MATERIALS SCIENCE↗