Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Fabrication and Testing of a Stainless Steel Quartz Coaxial Cable Structure for High Temperature Measurement

This paper presents a stainless-steel quartz coaxial cable structure for distributed sensing of high temperatures. The coaxial cable sensor uses stainless steel as the inner and outer conductors and quartz as the insulator in order to achieve mechanical strength and temperature resilience. Girdle-shaped reflectors are fabricated on the quartz tubing by CNC grinding and CO 2 laser resurfacing. The sensor operates by measuring the temperature dependent change in the effective electromagnetic length between the two adjacent reflectors on the quartz tubing. A retaining collar is fabricated at the tip of the quartz tubing by 3D printing and laser resurfacing to secure the connection between the sensor and the signal cable. The prototype sensor was tested for high temperature measurements up to 600°C, and the performance characteristics of the sensor such as sensitivity, resolution uncertainty, repeatability, and stability were estimated based on the test results.

Jiao, Xinyu↗

Estimation of High-Altitude Electromagnetic Pulse Signal Leakage into Power Generation Facilities: Simulations and Measurements

The coupling of early-time high-altitude electromagnetic pulse signals into a power generation facility was investigated. This study encompasses both electromagnetic simulation and on-site experimental efforts that are relevant to shielding effectiveness estimation with a passive technique. As an initial step in understanding the attenuation models involved, simulations were carried out as a function of frequency, building properties, and signal incidence angle. Testing was then performed at the US Department of Energy’s Oak Ridge National Laboratory campus to identify the equipment needed for signal collection and to fine-tune the experimental procedure. Finally, as an application of the models and methods presented, measurements were conducted at a power generation plant to derive the field transfer functions and coupled high-altitude electromagnetic pulse waveforms for various locations within the facility.

42 ENGINEERING↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Test of local position invariance using a double-cavity laser system

The results of testing local position invariance, which is a constituent of the Einstein equivalence principle, in a 'null' gravitational redshift experiment are reported. The processing of the experimental data collected during the five-month operation of a double-c avity laser system, where one cavity operates in the free generation mode and the frequency of the second cavity is stabilized with the nonlinear ultranarrow absorption resonance of the methane molecule, has confirmed the universality of the gravitational redshift law at a level of 0.9%. This result almost doubly improves the best existing accuracy (1.7%) of testing local position invariance for clocks of different physical natures.

74 ATOMIC AND MOLECULAR PHYSICS↗

On-site Real-Time Inspection System for Pump-impeller using X-band Linac X-ray Source

The methods of nondestructive testing (NDT) are generally ultrasonic, neutron, eddy-current and X-rays, NDT by using X-rays, in particular, is the most useful inspection technique having high resolution. We can especially evaluate corroded pipes of petrochemical complex, nuclear and thermal-power plants by the high energy X-ray NDT system. We develop a portable X-ray NDT system with X-band linac and magnetron. This system can generate a 950 keV electron beam. We are able to get X-ray images of samples with 1 mm spatial resolution. This system has application to real time impeller inspection because linac based X-ray sources are able to generate pulsed X-rays. So, we can inspect the rotating impeller if the X-ray pulse rate is synchronized with the impeller rotation rate. This system has application in condition based maintenance (CBM) of nuclear plants, for example. However, 950 keV X-ray source can only be used for thin tubes with 20 mm thickness. We have started design of a 3.95 MeV X-band linac for broader X-ray NDT application. We think that this X-ray NDT system will be useful for corrosion wastage and cracking in thicker tubes at nuclear plants and impeller of larger pumps. This system consists of X-band linac, thermionic cathode electron gun, magnetron and waveguide components. For achieving higher electric fields the 3.95 MeV X-band linac structure has the side-coupled acceleration structure. This structure has more efficient acceleration than the 950 keV linac with alternating periodic structure (APS). We adopt a 1.3 MW magnetron for the RF source. This accelerator system is about 30 cm long. The beam current is about 150 mA, and X-ray dose rate is 10 Gy at 1 m/500 pps. In this paper, the detail of the whole system concept and the electromagnetic field of designed linac structure will be reported.

43 PARTICLE ACCELERATORS↗

TESTING OF NB{sub 3}SN QUADRUPOLE COILS USING MAGNETIC MIRROR STRUCTURE

This paper describes the design and parameters of a quadrupole mirror structure for testing the mechanical, thermal and quench performance of single shell-type superconducting quadrupole coils at field, current and force levels similar to that of real magnet. The concept was experimentally verified by testing two quadrupole coils, previously used in quadrupole models, in the developed mirror structure in the temperature range from 4.5 to 1.9 K. The coils were instrumented with voltage taps, heaters, and strain gauges to monitor their mechanical and thermal properties and quench performance. A new quadrupole coil made of improved Nb{sub 3}Sn RRP-108/127 strand and cable insulation based on E-glass tape was also tested using this structure. The fabrication and test results of the quadrupole mirror models are reported and discussed.

36 MATERIALS SCIENCE↗

Proposal for testing the electric Aharonov-Bohm effect with superconductors

The phase of the wave function of charged matter is sensitive to the value of the electric potential, even when the matter never enters any region with nonvanishing electromagnetic fields. Despite its fundamental character, this archetypal electric Aharonov-Bohm effect has evidently never been observed. Here, we propose an experiment to detect the electric potential through its coupling to the superconducting order parameter. A potential difference between two superconductors will induce a relative phase shift that is observable via the DC Josephson effect even when no electromagnetic fields ever act on the superconductors, and even if the potential difference is later reduced to zero. This is a type of electromagnetic memory effect, and would directly demonstrate the physical significance of the electric potential.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Planck 2013 results. IX. HFI spectral response

The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (includingthe level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10 8 . The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. Furthermore, these coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting front within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positive-Sequence Modeling of Droop-Controlled Grid-Forming Inverters for Transient Stability Simulation of Transmission Systems

Here, this paper describes a positive-sequence model to represent two widely reported droop-controlled grid-forming inverters for bulk power systems simulation study. Methods of how to develop the equivalent voltage source behind impedance to represent inverters with and without inner control loops, modeling of P-f and Q-V droop controls, active and reactive power limiting modeling, and modeling of fault current limiting controls are described in detail. The model is implemented in commercially available positive-sequence simulation tools and compared with detailed electromagnetic transient models in both a single-grid-forming-inverter infinite-bus system and a modified IEEE 39-bus system. Finally, the model is tested on the full US Western Electricity Coordinating Council (WECC) system. Study results show that the model has a good level of accuracy compared to the detailed EMT models, and at the same time also achieves a high computational efficiency, which is suitable for the bulk power system simulation study.

42 ENGINEERING↗

WISE-CASING: Frequency Domain EM Data from Cymric Oil Field, CA

Cymric oil field frequency domain electromagnetic (FEM) data with two parts of data labeled Part 1 and Part 2. Part 1 utilizes an electrical source line parallel to the receiver line, while Part 2 utilizes an electrical source line at a 75 deg angle to the receiver line. Data are plotted and compared to numerically modeled data to observe electric field response to well structure. In two configuration files are diagrams of the experiment layout.

15 GEOTHERMAL ENERGY↗

QCD and Standard Model Studies

Our group has focused on using jets in STAR to investigate the longitudinal and transverse spin structure of the proton. We performed measurements of the longitudinal double-spin asymmetry for inclusive jet production that provide the strongest evidence to date that the gluons in the proton with x>0.05 are polarized. We also made the first observation of the Collins effect in pp collisions, thereby providing an important test of the universality of the Collins fragmentation function and opening a new tool to probe quark transversity in the proton. Our studies of forward rapidity electromagnetic jet-like events raise serious question whether the large transverse spin asymmetries that have been seen for forward inclusive hadron production arise from conventional 2 → 2 parton scattering. This is the final technical report for DOE Grant DE-FG02-93ER40765. It covers activities during the period January 1, 2015 through November 30, 2016.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Common Information Model for Electromagnetic Transients (CIM for EMT): CRADA 533 [Abstract only}

The control and protection functions of inverter-based resources (IBR) have raised concerns with bulk system reliability. Most of the current interest lies with solar photovoltaic generation but increasing amounts of storage would pose the same risks. Newer North American Electric Reliability Corporation (NERC) guidelines call for electromagnetic transient (EMT) studies of IBR and recommend that transmission operators collect distributed energy resource (DER) data to support such modeling. IEEE Standard P2800.1 is defining tests for model parameterization, so good model data should become available from inverter vendors. (EMT studies also apply to large power transformer reliability, and transformer vendors can provide EMT models.) Utilities don’t currently have the rest of the bulk system represented for EMT studies at large scale. An International Electrotechnical Commission (IEC) standard Common Information Model (CIM) provides a way of supporting these detailed models from physical asset data, e.g., conductors, towers, transformer data sheets, control block diagrams, while avoiding software vendor lock-in. CIM-for-EMT, with proposed schema extensions and open-source converters, provides a way to exchange EMT data between organizations and tools. This project leverages Office of Electricity (OE) funding of CIM-for-EMT code base through the GridAPPS-DTM project, and of GridPACKTM (parallelized transmission solver), for interoperability testing in CIM-for-EMT. The project also leverages partner PGSTech investments in EMTP® interoperability with CIM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Superconducting Multi-Spoke Cavities for High-Velocity Applications

Superconducting spoke cavities have been designed and tested for particle velocities up to {beta}{sub 0} ~ 0.6 and are currently being designed for velocities up to {beta}{sub 0} = 1. We present the electromagnetic designs for two-spoke cavities operating at 325 MHz for {beta}{sub 0} = 0.82 and {beta}{sub 0} = 1.

43 PARTICLE ACCELERATORS↗

Whitepaper submitted to Snowmass21: Advanced accelerator linear collider demonstration facility at intermediate energy

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1--100~GV/m, leading to compact acceleration structures. Over the last 10-15 years significant progress has been achieved in accelerating electron beams by ANAs. For example, the demonstration of several-GeV electron beams from laser-powered capillary discharge waveguides, as well as the proof-of-principle coupling of two accelerating structures powered by different laser pulses, has increased interest in ANAs as a viable technology to be considered for a compact, TeV-class, lepton linear collider. However, intermediate facilities are required to test the technology and demonstrate key subsystems. A 20-100 GeV center-of-mass energy ANA-based lepton collider can be a possible candidate for an intermediate facility. Apart from being a test beam facility for accelerator and detector studies, this collider will provide opportunities to study muon and proton beam acceleration, investigate charged particle interactions with extreme electromagnetic fields (relevant for beam delivery system designs and to study the physics at the interaction point), as well as precision Quantum Chromodynamics and Beyond the Standard Model physics measurements. Possible applications of this collider include the studies of $\gamma\gamma$ and $e$-ion collider designs.

43 PARTICLE ACCELERATORS↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗

Resonance region structure functions and parity-violating deep inelastic scattering

The primary motive of parity-violating deep inelastic scattering experiments has been to test the standard model, particularly the axial couplings to the quarks, in the scaling region. The measurements can also test for the validity of models for the off-diagonal structure functions ${F}_{1,2,3}^{γZ}$($x,Q^2$) in the resonance region. The off-diagonal structure functions are important for the accurate calculation of the $γZ$-box correction to the weak charge of the proton. Currently, with no data to determine ${F}_{1,2,3}^{γZ}$($x,Q^2$) directly, models are constructed by modifying existing fits to electromagnetic data. Here, we present the asymmetry value for deuteron and proton targets predicted by several different ${F}_{1,2,3}^{γZ}$($x,Q^2$) models and demonstrate that there are notable disagreements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

RF Choke for Standing Wave Structures and Flanges

SLAC participates in the U.S. High Gradient collaboration whose charter includes basic studies of rf breakdown properties in accelerating structures. These studies include experiments with different materials and construction methods for single cell standing wave accelerating structures. The most commonly used method of joining cells of such structures is the high temperature bonding and/or brazing in hydrogen and/or vacuum. These high temperature processes may not be suitable for some of the new materials that are under consideration. We propose to build structures from cells with an rf choke, taking the cell-to-cell junction out of the electromagnetic field region. These cells may be clamped together in a vacuum enclosure, the choke joint ensuring continuity of rf currents. Next, we propose a structure with a choke joint in a high gradient cell and a view port which may allow us microscopic, in-situ observation of the metal surface during high power tests. And third, we describe the design of a TM01 choke flange for these structures.

08 HYDROGEN↗