Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Fluid Inclusions in Extraterrestrial Samples: Failures, Successes, Possibilities, and A Note of Caution

Over the past half century the search for life in the solar system and beyond has become a major research focus, with much effort devoted to finding evidence for liquid H2O and reduced carbon-bearing (organic) species in extraterrestrial samples. The most direct and convincing evidence for the presence of water and organic molecules is provided by fluid inclusions (FI)trapped in minerals that formed on the parent bodies. Beginning in the 1970s, reports of FI in extraterrestrial samples generated much enthusiasm within the planetary sciences community. However, many of the reported FI were determined to be artifacts of sample preparation, or incomplete characterization of features that appear to be FI, or were inconsistent with the inferred PT history of the meteorite sample. An early report of aqueous (and hydrocarbon-bearing) FI in stony meteorites and the subsequent follow-up study that showed that most or all of the “FI” contained water used during cutting and polishing of the samples led to a general unwillingness to believe later reports of FI in meteorites. One of the first confirmed occurrences of extraterrestrial aqueous (liquid) fluid inclusions in a meteorite was reported by Zolensky et al. (1999; Science), who described aqueous inclusions in halite in the Monahans and later the Zag meteorites. These meteorite falls were collected shortly after landing on earth and were prepared without using water or other fluids that could introduce artifacts. The oxygen and hydrogen isotopic composition of water in FI in these same samples was later measured, showing that the fluids represent various degrees of water-rock interaction on the parent body .In more recent years, careful studies of FI trapped in extraterrestrial samples combining synchrotron X-ray computed tomography to locate FI in samples followed by cryo-TOF-SIMS analysis of the FI have identified the presence of molecular fragments suggesting the presence of H2O and various organic molecules in the fluids. Challenges associated with studying FI in extraterrestrial samples include the limited abundance of potential host phases for FI, such as carbonates and phosphates, the often poor optical quality of the host phases, and the small size of the FI, with few as large as 5 microns and most less than 1-2 microns in maximum dimension

Robert Bodnar↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil↗

Methods, systems, and devices to optimize a fluid harvester

An apparatus for energy extraction from fluid flow including an assembly including a plenum. The assembly further includes an aperture extending from an exterior surface to the plenum to allow flow therethrough. The apparatus further includes a channel including an inlet and an outlet in fluid communication with the plenum. The apparatus yet further includes an energy extraction device. The assembly is configured to create a pressure differential between the plenum and the inlet of the channel. The pressure differential causes fluid flow from the inlet of the channel to the plenum. The energy extraction device is configured to extract energy from the fluid flow. The apparatus additionally includes a control system configured to modify the pressure differential to control the fluid flow between the inlet of the channel and the plenum based on a characteristic of an exterior environment.

Houchens, Brent Charles↗

Molten fluid apparatus with solid non-brittle electrolyte

A battery includes a fluid negative electrode and a fluid positive electrode separated by a solid electrolyte at least when the electrodes and electrolyte are at an operating temperature. The solid electrolyte includes ions of the negative electrode material forming the fluid negative electrode and has a softness less than beta-alumina solid electrolyte (BASE) ceramics. In one example, the fluid negative electrode comprises lithium (Li), the fluid positive electrode comprises sulfur (S) and the solid electrolyte comprises lithium iodide (LiI).

Vissers, Daniel R.↗

Molten fluid apparatus with solid non-brittle electrolyte

A battery includes a fluid negative electrode and a fluid positive electrode separated by a solid electrolyte at least when the electrodes and electrolyte are at an operating temperature. The solid electrolyte comprises a salt formed by ions of the negative electrode material forming the fluid negative electrode. In one example, the fluid negative electrode comprises lithium (Li), the fluid positive electrode comprises sulfur (S) and the solid electrolyte comprises lithium iodide (LiI).

Vissers, Daniel R.↗

INVESTIGATION OF ROCK-FLUID INTERACTIONS USING GEOMATERIAL MICROFLUIDICS

Illite and Illite-Smectite clays are reportedly the Caney Shale's most prevalent clay minerals. The swelling and fines migration of clays may occur when water-based fluids contact the clay minerals. This may result in the reduction of pore space and permeability, and wettability alteration. Therefore, we quantified the swelling potentials, fines migration and wettability alteration of Illite and Illite-Smectite clays upon exposure to model brines and a produced water, and a model oil and a crude oil. We measured density, viscosity, pH, TDS, and interfacial tension as they are important in multiphase flow and displacement characteristics. Geomaterial microfluidics is recently being used to study physicochemical interactions of solid-fluid systems. It facilitates visualizing the surface behavior upon exposure to various fluids. This study includes preparation and characterization of Illite-Smectite clay-coated glass capillary tubes. Illite and Illite-Smectite clay-coated geomaterial microfluidic surfaces were prepared to investigate the effects of first contact fluid, brine salinity, and aging on wettability. In this work, advancing and receding contact angles of model brine-air, model oil-air, produced water-air, crude oil-air, model brine-model oil systems, and produced water-crude oil systems have been measured in the untreated, and clay-coated microfluidic channels of 1000 µm width and 50 µm depth. The aging effect was studied by retaining the non-aqueous and aqueous solutions in the corresponding microfluidic channels for approximately 24 h in the case of channels first contacted by aqueous and non-aqueous solutions, respectively. The advancing and receding contact angles of Caney shale-crude oil-produced water systems were also measured. The experimental findings indicate the swelling potential, fines migration, and wettability alteration of Illite and Illite-Smectite clays. The results signify the influence of first contact fluid, brine salinity, and aging on wettability of the untreated and clay-coated microfluidic surfaces. The experiments also demonstrate the wetting nature of the Caney shale samples from reservoir and non-reservoir zones.

02 PETROLEUM↗

Filament extension atomizers: A study of integration potential into spray dryers for high-viscosity and non-Newtonian fluids

Filament extension atomizers (FEAs) are an emerging class of spray nozzles designed to atomize high-viscosity and non-Newtonian fluids that are challenging for conventional pressure or two-fluid nozzles. In this study, we investigate the influence of roller geometry, surface velocity, roller material, and fluid rheology on the atomization performance of FEA systems using concentrated whey protein suspensions (50–70 wt. %). Extensional and shear rheology experiments, along with high-speed imaging and particle image velocimetry, reveal that filament breakup dynamics are governed by competition between inertial, capillary, and viscoelastic stresses. High roller rotational velocity leads to narrower spray cones, contradicting rheology experiments and suggests a significant inertial contribution to filament breakup. Smaller rollers operating at the same rotational velocity led to broader spray cones consistent with expectations. An FEA nozzle was integrated into a conventional dryer producing particles in the 100 μm range. Results suggest that FEA technology enables atomization of highly viscous fluids at industrially relevant spray cone angles similar to those generated by pressure nozzles, offering a pathway to improve energy efficiency in spray drying by enabling higher solids loading feedstocks. Furthermore, these insights provide critical guidance for optimizing FEA nozzle designs and process parameters across a range of applications.

Energy efficiency↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local well-posedness and singularity formation in non-Newtonian compressible fluids

We investigate the initial value problem of a very general class of 3 + 1 non-Newtonian compressible fluids in which the viscous stress tensor with shear and bulk viscosity relaxes to its Navier–Stokes values. These fluids correspond to the non-relativistic limit of well-known Israel–Stewart-like theories used in the relativistic fluid dynamic simulations of high-energy nuclear and astrophysical systems. After establishing the local well-posedness of the Cauchy problem, we show for the first time in the literature that there exists a large class of initial data for which the corresponding evolution breaks down in finite time due to the formation of singularities. This implies that a large class of non-Newtonian fluids do not have finite solutions defined at all times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and numerical studies of seismic fluid-structure interaction in a base-supported cylindrical vessel

Seismic design and qualification of advanced reactors will rely heavily on the use of verified and validated numerical models capable of capturing the interaction of the vessel, its contained fluid, and the internal equipment: fluid-structure interaction (FSI) analysis. Analytical solutions can be used for preliminary sizing and design of such vessels but their application is limited to simple geometries and boundary conditions, and small amplitude, translational (and rotational) inputs. To validate numerical models for seismic FSI analysis in finite element codes, a comprehensive set of experiments was performed on a liquid-filled cylindrical vessel, using a 6 degree-of-freedom earthquake simulator. Results in terms of sloshing frequency, damping ratio in sloshing modes, and hydrodynamic responses (wave height, hydrodynamic pressure, base shear, and base moment) for multi-directional earthquake simulator inputs are reported and compared with analytical solutions for liquid-filled vessels. The impact of seismic (base) isolation on hydrodynamic responses was studied using earthquake simulator inputs generated using a virtual isolation system. Data from the experiments are used to validate a numerical model of the fluid-filled vessel using the Arbitrary Lagrangian Eulerian (ALE) solver in the commercial finite element program LS-DYNA. Validation studies are presented for multi-directional seismic inputs, including rocking motions. Lagrangian modeling approaches using an elastic material formulation for the fluid are also investigated and their limitations and possible applications are identified. Here, the results are broadly applicable to the seismic response of base supported, liquid-filled vessels.

58 GEOSCIENCES↗

Development, verification, and validation of comprehensive acoustic fluid-structure interaction capabilities in an open-source computational platform

The acoustic fluid-structure interaction (FSI) formulation is a practical numerical approach for the seismic analysis of fluid-filled tanks. However, there are no verification and validation studies reported in the literature that demonstrate the ability of an acoustic FSI numerical model to predict responses important to structural and mechanical design for intense translational and rotational earthquake inputs. Herein, an acoustic FSI formulation is implemented in the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE), and is formally verified and validated using analytical solutions and code-to-code verification, and experimental data, respectively. The analytical solutions are for small amplitude, unidirectional seismic inputs. The code-to-code verification utilizes a previously verified and validated Arbitrary Lagrangian-Eulerian (ALE) numerical model in the commercial finite element code LS-DYNA. The validation studies utilize a comprehensive data set assembled from results of 3D earthquake-simulator tests of a fluid-filled vessel. The acoustic numerical model in MOOSE is verified and validated for hydrodynamic pressures and support reactions except for cases that involve significant convective response. For small amplitude inputs, numerically predicted wave heights match those of the analytical solutions. The numerical model is not verified and validated for wave height calculations under intense 3D seismic inputs. The run times for the acoustic FSI simulations in MOOSE are an order of magnitude, or more, shorter than for the corresponding ALE simulations in LS-DYNA. The utility of the MOOSE acoustic FSI implementation is demonstrated by seismic analysis of a building equipped with a fluid-filled, advanced nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characteristics of Fluid‐Solid Interaction Constitutive Models Within Poroelastodynamics at Higher Strain‐Rates and Large Deformations Implemented in 1D

The large deformation, mixed formulation, finite element (FE) modeling approach presented in Irwin et al. 2024 is extended herein to include improved constitutive models for representing dynamic solid-fluid interactions at higher strain rates (𝒪⁢(1⁢0 2 −1⁢0 3 )⁢s −1 ) and larger overpressure magnitudes (𝒪⁡(1⁢0 2 )⁢kPa) within a biphasic soft porous material using Theory of Porous Media (TPM) at finite strain. Specifically, these constitutive modeling improvements are the following: (i) a more physically robust constitutive model for pore fluid seepage velocity via inclusion of pore fluid viscous stress, and (ii) a modified deformation-dependent-permeability model and updated hyperelastic constitutive model better suited for handling larger volumetric compressions and extensions. The novelty of the present work is mainly the contribution (i): inclusion of pore fluid viscous stress at higher strain-rate and large deformations, which requires 𝐶 1 continuity in the weak formulation, accomplished by employing Hermite cubic interpolation functions within a mixed nonlinear poromechanical finite element formulation. In (ii), the model is updated to weakly enforce solid phase incompressibility, such that this assumption is not violated numerically, which provides improved numerical stability for achieving larger overpressure magnitudes on 𝒪⁡(1⁢0 2 ) kPa, which were not achievable with the previous Kozeny–Carman model in Irwin et al. 2024. Also in (ii), the volumetric part of the solid skeleton free energy function is modified to ensure proper bounds on the solid skeleton Jacobian of deformation 𝐽 s related to incompressibility of the solid phase. Uniaxial strain, unidirectional flow examples at higher strain rates (𝒪⁢(1⁢0 2 −1⁢0 3 )⁢s −1 ) and larger deformations (up to 0.2 (or 20%) nominal axial strain) demonstrate the improved physical representation—and numerical stability—of these constitutive model improvements.

42 ENGINEERING↗

A two-fluid single-column model of turbulent shallow convection. Part II: Single-column model formulation and numerics

The two-fluid single-column model of Thuburn et al. (Quart. J. R. Meteorol. Soc., 2019, 145, 1535–1550) is extended to include moisture and horizontal wind shear. Turbulent kinetic energy is introduced as a prognostic variable, dependence on a diagnosed boundary-layer height is removed, and subfilter fluxes are approximated using a two-fluid version of a Mellor–Yamada scheme. Three mechanisms for entrainment and detrainment processes are introduced, which represent entrainment of unstable air at the surface, forced detrainment of air at the top of the boundary/cloud layers, and turbulent mixing that relaxes the convective fluid to a reference profile. A semi-implicit Eulerian discretization replaces the semi-implicit semi-Lagrangian implementation of Thuburn et al. (Quart. J. R. Meteorol. Soc., 2019, 145, 1535–1550) to improve numerical stability and conservation. The equations for the implicit time step are solved using a quasi-Newton method, which is shown to perform well in numerical tests for conservation and convergence. The two-fluid single-column model presented in this article will be applied to simulations of shallow cumulus convection in Part III.

54 ENVIRONMENTAL SCIENCES↗

Ensemble Kalman filter for data assimilation coupled with low-resolution computations techniques applied in fluid dynamics

This paper presents an innovative Reduced-order model (ROM) for merging experimental and simulation data using data assimilation (DA) to estimate the "True" state of a fluid dynamics system, leading to more accurate predictions. Our methodology introduces a novel approach by implementing the ensemble Kalman filter (EnKF) within a reduced-dimensional framework, grounded in a robust theoretical foundation and applied to fluid dynamics. To address the substantial computational demands of DA, the proposed ROM employs low-resolution (LR) techniques to drastically reduce computational costs. This innovative approach involves downsampling datasets for DA computations, followed by an advanced reconstruction technique based on low-cost singular value decomposition (lcSVD). The lcSVD method, a key innovation in this paper, has never been applied to DA before and offers a highly efficient way to enhance resolution with minimal computational resources. Our results demonstrate significant reductions in both computation time and RAM usage through these LR techniques without compromising the accuracy of the estimations. For instance, in a turbulent test case, for a data compression rate of 15.9, the LR approach can achieve a speed-up of 13.7 and a RAM compression of 90.9% while maintaining a low relative root mean square error (RRMSE) of 2.6%, compared to 0.8% in the high-resolution (HR) reference. Furthermore, we highlight the effectiveness of the EnKF in estimating and predicting the state of fluid flow systems based on limited observations and given low-fidelity numerical data. This paper highlights the potential of the proposed DA method in fluid dynamics applications, particularly for improving computational efficiency in CFD and related fields. Its ability to balance accuracy with low computational and memory costs makes it especially suitable for large-scale and real-time applications, such as environmental monitoring or engineering design. This method will be incorporated into ModelFLOWs-app.

Data Assimilation↗

Estimation of the Thermal-Fluids and Thermal-Structural Performance of Helium-Cooled Modular Finger-Type Divertors

Over the past decade, our group has investigated the thermal-fluid performance of the helium-cooled modular divertor with multiple jets (HEMJ) and a simplified “flat” design of the HEMJ for long-pulse magnetic fusion energy (MFE) reactors. Experimental studies were performed in a helium (He) loop at the prototypical pressure of 10 MPa, nearly prototypical He temperatures and incident heat fluxes using test sections made from stainless steel and tungsten alloys. Correlations for average Nusselt numbers and pressure loss coefficients were developed from the data and are used to validate computational fluid dynamics (CFD) models. Here, this work presents updated thermal-fluids performance curves based on these correlations that estimate the maximum heat flux that can be accommodated by the plasma-facing surface and coolant pumping power requirements at prototypical operating conditions. Thermal-structural performance curves developed from ITER structural design criteria are introduced, which include protection against ductile and non-ductile failure, ratcheting fatigue, and creep fatigue. The performance design curves for these finger-type divertors demonstrate that the “flat” design, with a significantly less complicated geometry than the HEMJ, has thermal-fluid and thermal-structural performance comparable to the original HEMJ concept, and may be superior in terms of non-ductile failure criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pool boiling heat transfer evaluation of next-generation dielectric fluid: Opteon™ 2P50

The growing use of artificial intelligence has led to heavy thermal loads and high heat dissipation rates in data centers. Conventional air-cooled technologies are not able to fulfill these requirements. To overcome these challenges, two-phase immersion cooling (2PIC) has emerged as one of the leading technologies for high power-density chips. 2PIC increases the heat dissipation rate and efficiency of the system while reducing the footprint of the cooling equipment. A fluid with adequate dielectric properties, a suitable normal boiling temperature to maintain chip temperatures, and good material compatibility, is desired for 2PIC system. In this study, the pool boiling heat transfer of a new developmental dielectric fluid, Opteon™ 2P50, was experimentally investigated. The heat transfer coefficients at various heat fluxes (20–150 kW/m 2 ) and the critical heat flux were measured using a smooth aluminum surface. Compared with HFE-7100, Opteon™ 2P50 shows higher heat transfer coefficient (up to 59% higher) and a slightly lower value of critical heat flux (around 5.9% lower). The modified Cooper correlation with the optimized leading constant resulted in reliable prediction accuracy with a 5.3% mean absolute error percentage. Overall, these results indicate that the new dielectric fluid provides similar thermal performance to some legacy fluids.

2P50↗