Search NASA⌕ Search

SEARCH · Search NASA

Results for “FRAGMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Fission fragment mass and energy distributions as a function of incident neutron energy measured in a lead slowing-down spectrometer

A new method of measuring fission fragment mass and energy distributions as a function of incident neutron energy in the range from below 0.1 eV to 1 keV has been developed. The method involves placing a double-sided Frisch-gridded fission chamber in Rensselaer Polytechnic Institute's lead slowing-down spectrometer (LSDS). The high neutron flux of the LSDS allows for the measurement of the energy-dependent, neutron-induced fission cross sections simultaneously with the mass and kinetic energy of the fission fragments of various small samples. The samples may be isotopes that are not available in large quantities (submicrograms) or with small fission cross sections (microbarns). The fission chamber consists of two anodes shielded by Frisch grids on either side of a single cathode. The sample is located in the center of the cathode and is made by depositing small amounts of actinides on very thin films. The chamber was successfully tested and calibrated using 0.41+-0.04 ng of {sup 252}Cf and the resulting mass distributions were compared to those of previous work. As a proof of concept, the chamber was placed in the LSDS to measure the neutron-induced fission cross section and fragment mass and energy distributions of 25.3+-0.5 mug of {sup 235}U. Changes in the mass distributions as a function of incident neutron energy are evident and are examined using the multimodal fission mode model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission fragment angular distributions in the {sup 9}Be + {sup 232}Th reaction

Fission fragment angular distributions have been measured for a {sup 9}Be + {sup 232}Th system at four different beam energies around the Coulomb barrier. The experimental results on fission fragment anisotropies have been compared with predictions of the standard statistical saddle-point model (SSPM) and the preequilibrium fission (PEQ) model including projectile ground-state spin. It is observed that both SSPM and the PEQ model fail to reproduce the experimental results, indicating that projectile breakup may affect the fission fragment anisotropies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Comparison of Four- Versus Three-Pass Transjugular Biopsy Using a 19-G Tru-Cut Needle and a Randomized Study Using a Cassette to Prevent Biopsy Fragmentation

Recently, it has been shown that transjugular liver biopsy (TJLB) with three passes gives comparable specimens to percutaneous liver biopsy (PLB). The aim of this study was to evaluate the adequacy of TJLB using four passes in a consecutive series of patients, and whether using a supportive cassette can prevent fragmentation. One hundred consecutive TJLBs in 92 patients (48 transplanted), always using four passes (19-G Tru-Cut), were compared to three-pass TJLBs. The four-pass TJLB specimens were randomized at a 1:1 ratio of liver cores placed in a cassette versus not. The four-pass TJLBs, compared to three-pass TJLBs, resulted in better specimens for length ({>=}25 mm: 50% vs. 35%; p = 0.026) and number of complete portal tracts (CPTs) ({>=}11: 40% vs. 26%; p = 0.027), without a higher complication rate. The four-pass TJLB with {>=}11 CPTs had a median length of 27 mm, and 57% of them longer than 28 mm contained {>=}11 CPTs. Putting the liver biopsy cores into a cassette did not improve the fragmentation rate or adequacy of the specimen (length and number of CPTs) of TJLB. We conclude that at least four passes with TJLB should be performed when liver specimens are needed for grading and staging. Using a supportive cassette did not reduce fragmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Set up of an experimental apparatus for the study of fragmentation of solid fuels upon severe heating

An experimental apparatus has been developed in order to perform tests of primary fragmentation of solid fuels under severe heating conditions. The device is a modified heated strip reactor, capable to reach 2000 C in less than 0.2 s. Particles are laid on the strip and pyrolysed under inert or moderately oxidizing conditions. The char particles and their fragments, generated upon pyrolysis, can be recovered and analysed to assess the fragmentation propensity of the fuel. Some preliminary experiments have been carried out on two biomass samples in order to assess the time-temperature history of particles in the experimental apparatus. In particular biomass particles of approximately 2-3 mm have been used. The temperature of the heated strip reactor in such preliminary tests was varied between 1000 and 1600 C, while the strip nominal heating rate was kept at 10{sup 4} C/s and the holding time was set at the value of 10 s. A near infrared fast camera (38,000 frames/s) has been used to measure the temperature of the heated strip and of the particles during the tests. A heat up model was developed and validated against experimental results. The model was then used to estimate the temperature gradients across particles of biomass and of coal as well. Results show that the strip of the reactor reaches the set temperature in less than 0.2 s. When particles are laid on the strip, their bottom surface, which is in physical contact with the strip, immediately reaches the set temperature value. For 1 mm coal particles the upper surface can be considered at the same temperature as well. Under the most severe conditions tested (strip temperature of 1600 C, biomass particles of 2 mm thickness) the temperature difference between the bottom and the upper face is 200 C after 3 s and drops to 100 C after 10 s. On the whole the experimental apparatus simulates uniform heating of the particles with reasonable approximation. In the next future the apparatus will be further upgraded to operate at pressures up to 20 bars. (author)

01 COAL, LIGNITE, AND PEAT↗

Energetics and Dynamics of Dissociation of Deprotonated Peptides: Fragmentation of Angiotensin Analogs

We present a first study of the energetics and dynamics of dissociation of deprotonated peptides using time- and collision-energy resolved surface-induced dissociation (SID) experiments. SID of four model peptides: RVYIHPF, HVYIHPF, DRVYIHPF, and DHVYIHPF was studied using a specially designed Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) configured for studying ion-surface collisions. Energy and entropy effects for the overall decomposition of the precursor ion were deduced by modeling the time- and collision energy-resolved survival curves using an RRKM based approach developed in our laboratory. The results were compared to the energetics and dynamics of dissociation of the corresponding protonated species. We demonstrate that acidic peptides are less stable in the negative mode because of the low threshold associated with the kinetically hindered loss of H2O from [M-H]- ions. Comparison between the two basic peptides indicates that the lower stability of the [M-H]- ion of RVYIHPF as compared to HVYIHPF towards fragmentation is attributed to the differences in fragmentation mechanisms. Specifically, threshold energy associated with losses of NH3 and NHCNH from RVYIHPF is lower than the barrier for backbone fragmentation that dominates gas-phase decomposition of HVYIHPF. The results provide a first quantitative comparison between the energetics and dynamics of dissociation of [M+H]+ and [M-H]- ions of acidic and basic peptides.

59 BASIC BIOLOGICAL SCIENCES↗

Extension of moment projection method to the fragmentation process

The method of moments is a simple but efficient method of solving the population balance equation which describes particle dynamics. Recently, the moment projection method (MPM) was proposed and validated for particle inception, coagulation, growth and, more importantly, shrinkage; here the method is extended to include the fragmentation process. The performance of MPM is tested for 13 different test cases for different fragmentation kernels, fragment distribution functions and initial conditions. Comparisons are made with the quadrature method of moments (QMOM), hybrid method of moments (HMOM) and a high-precision stochastic solution calculated using the established direct simulation algorithm (DSA) and advantages of MPM are drawn.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integral LOCA fragmentation test on high-burnup fuel

Increasing the fuel burnup limit in light water reactors is sought to enhance fuel cycle economics and requires establishing a technical basis. Experimental observations of severe fuel fragmentation under loss-of-coolant-accident conditions at Halden and Studsvik had raised the need for additional considerations during the development of this technical basis. These test data suggested that the burnup threshold for high burnup fuel fragmentation may be influenced by pre-transient power. Additional loss-of-coolant-accident test data is therefore valuable to complement these tests and enhance the current state of understating. Oak Ridge National Lab has developed the Severe Accident Test Station capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident and beyond design basis accident scenarios. Severe Accident Test Station provides various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident testing, defueled oxidation quench testing, and high-temperature beyond design basis accident testing. Severe Accident Test Station has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory at Oak Ridge National Lab. Furthermore, descriptions of the in-cell re-fabrication capabilities and assembly of the loss-of-coolant-accident test train are provided. Installation of the Severe Accident Test Station system and in-cell re-fabrication restores United States capability to examine postulated and extended loss-of-coolant-accident conditions on spent fuel and cladding and provides a platform for evaluating advanced fuel and accident-tolerant fuel cladding concepts. Lastly, three in-cell integral loss-of-coolant-accident test were performed in the Severe Accident Test Station and compared to the Nuclear Regulatory Commission sponsored loss-of-coolant-accident test as well as the original loss-of-coolant-accident test performed at Argonne National Lab. Finally, the results of these tests as well as all publicly available integral loss-of-coolant-accident test were used to validate a threshold for high burnup fuel fragmentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The impact of partial manganese superoxide dismutase (SOD2)-deficiency on mitochondrial oxidant stress, DNA fragmentation and liver injury during acetaminophen hepatotoxicity

Acetaminophen (APAP) hepatotoxicity is the most frequent cause of acute liver failure in many countries. The mechanism of cell death is initiated by formation of a reactive metabolite that binds to mitochondrial proteins and promotes mitochondrial dysfunction and oxidant stress. Manganese superoxide dismutase (SOD2) is a critical defense enzyme located in the mitochondrial matrix. The objective of this investigation was to evaluate the functional consequences of partial SOD2-deficiency (SOD2+/-) on intracellular signaling mechanisms of necrotic cell death after APAP overdose. Treatment of C57Bl/6J wild type animals with 200 mg/kg APAP resulted in liver injury as indicated by elevated plasma alanine aminotransferase activities (2870 {+-} 180 U/L) and centrilobular necrosis at 6 h. In addition, increased tissue glutathione disulfide (GSSG) levels and GSSG-to-GSH ratios, delayed mitochondrial GSH recovery, and increased mitochondrial protein carbonyls and nitrotyrosine protein adducts indicated mitochondrial oxidant stress. In addition, nuclear DNA fragmentation (TUNEL assay) correlated with translocation of Bax to the mitochondria and release of apoptosis-inducing factor (AIF). Furthermore, activation of c-jun-N-terminal kinase (JNK) was documented by the mitochondrial translocation of phospho-JNK. SOD2+/- mice showed 4-fold higher ALT activities and necrosis, an enhancement of all parameters of the mitochondrial oxidant stress, more AIF release and more extensive DNA fragmentation and more prolonged JNK activation. Conclusions: the impaired defense against mitochondrial superoxide formation in SOD2+/- mice prolongs JNK activation after APAP overdose and consequently further enhances the mitochondrial oxidant stress leading to exaggerated mitochondrial dysfunction, release of intermembrane proteins with nuclear DNA fragmentation and more necrosis.

60 APPLIED LIFE SCIENCES↗

Theoretical Insights on the Fragmentation of Cellulosic Oligomers to Form Hydroxyacetone and Hydroxyacetaldehyde

The presence of heavy unknown oligomeric sugar products in bio-oil is evidenced in experimental results reported in the literature. In this paper, we study the fragmentation reactions yielding acetol and glycolaldehyde from oligomeric sugars following previous work on dehydration reactions to propose structures of these oligomers. Acetol and glycolaldehyde are primary products of cellulose fast pyrolysis but the fragmentation reaction mechanism of these compounds from oligomers merits further study. The density functional theory (DFT) approach was employed to study this reaction. Results revealed that acetol and glycolaldehyde fragments are favorably removed from the non-reducing end based on their thermodynamic stabilities. Theoretical FTIR and NMR spectra were calculated to aid in understanding the structures of the oligomeric sugars. Also, the thermodynamics and physical properties of these compounds were estimated using the Group Contribution Method (GCM). In conclusion, these properties are essential in the design of processing technologies and the upgrading of products.

10 SYNTHETIC FUELS↗

The Effect of the Secondary Structure on Dissociation of Peptide Radical Cations: Fragmentation of Angiotensin III and Its Analogues

Fragmentation of protonated RVYIHPF and RVYIHPF-OMe and the corresponding radical cations was studied using time- and collision energy-resolved surface-induced dissociation (SID) in a Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially equipped to perform SID experiments. Peptide radical cations were produced by gas-phase fragmentation of CoIII(salen)-peptide complexes. Both the energetics and mechanisms of dissociation of even-electron and odd-electron angiotensin III ions are quite different. Protonated molecules are much more stable towards fragmentation than the corresponding radical cations. RRKM modeling of the experimental data suggests that this stability is largely attributed to differences in threshold energies for dissociation while activation entropies are very similar. Detailed analysis of the experimental data obtained for radical cations demonstrated the presence of two distinct structures separated by a high free-energy barrier. The two families of structures were ascribed to the canonical and zwitterionic forms of the radical cations produced in our experiments.

59 BASIC BIOLOGICAL SCIENCES↗

A bent electrostatic ion beam trap for simultaneous measurements of fragmentation and ionization of cluster ions

We describe a bent electrostatic ion beam trap in which cluster ions of several keV kinetic energy can be stored on a V-shaped trajectory by means of an electrostatic deflector placed between two electrostatic mirrors. While maintaining all the advantages of its linear counterpart [Zajfman et al., Phys. Rev. A 55, R1577 (1997); Dahan et al., Rev. Sci. Instrum. 69, 76 (1998)], such as long storage times, straight segments, and a field-free region for merged or crossed beam experiments, the bent trap allows for simultaneous measurement of charged and neutral fragments and determination of the average kinetic energy released in the fragmentation. These unique properties of the bent trap are illustrated by first results concerning the competition between delayed fragmentation and ionization of Al{sub n}{sup -} clusters after irradiation by a short laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Isomers in Fission Fragments

The structure of neutron-rich nuclei produced as secondary fission fragments was investigated using the EUROGAM and GAMMASPHERE ACS arrays, the LOHENGRIN fission-fragment mass separator and the FIFI fission-fragment identifier. Fission products were populated in spontaneous fission of {sup 248}Cm and {sup 252}Cf and in thermal neutron-induced fission of {sup 233}U, {sup 235}U and {sup 241}Pu at ILL Grenoble. Particularly useful in such studies are isomeric states, well populated in fission due to their yrast character, easy to detect due to their long half lives and easy to interpret because of their relatively simple composition. We discuss their role in studies of neutron-rich nuclei, giving examples of isomers found in our recent experiments. A special type of K-isomers, resulting from 'crossing' of extruder and intruder orbitals plays a role in the mechanism of a sudden onset of deformation in the A = 100 and A = 150 regions. We present evidence for these isomers in both regions. Possible further studies in this field are proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft recovery technique to investigate dynamic fragmentation of laser shock-loaded metals

With the development of high energy laser facilities dedicated to inertial confinement fusion, the question of debris ejection from metallic shells subjected to intense laser irradiation has become a key issue. We have used two diagnostics to investigate fragmentation processes. Recovery of ejected fragments has been performed in a highly transparent gel of density 0.9 g/cm{sup 3}. Fragments sizes, shapes, and penetration depths, can be easily observed with a spatial resolution of micrometer-order. Complementary data are provided by transverse shadowgraphy which allows to obtain quasi-instantaneous, successive pictures of the debris clouds and mean ejection velocities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quark fragmentation to pions and kaons in the NJL-jet model

We describe the quark fragmentation functions to pions and kaons in the NJL-jet model and compare the results with empirical parametrizations. By including cascade-like fragmentation processes, the momentum and isospin sum rules can be satisfied naturally without introducing new parameters into the theory. We associate a low energy scale with the NJL model, and perform the Q{sup 2} evolution in leading order. The results are in reasonable agreement with the empirical fragmentation functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Momentum imaging spectrometer for molecular fragmentation dynamics induced by pulsed electron beam

A momentum imaging spectrometer has been built for studying the electron impact molecular fragmentation dynamics. The setup consists of a pulsed electron gun and a time of flight system as well as a two-dimensional time and position sensitive multi-hit detector. The charged fragments with kinetic energy up to 10 eV can be detected in 4π solid angles and their three-dimensional momentum vectors can be reconstructed. The apparatus is tested by electron impact ionization of Ar and dissociative ionization of CO{sub 2}. By analyzing the ion-ion coincidence spectra, the complete and incomplete Coulomb fragmentation channels for CO{sub 2}{sup 2+} and CO{sub 2}{sup 3+} are identified. The kinetic energy release (KER) and angular correlation for the two-body breakup channel CO{sub 2}{sup 2+*}→ O{sup +}+ CO{sup +} are reported. The peak value of total KER is found to be 6.8 eV which is consistent with the previous photoion-photoion coincidence studies, and the correlation angle of O{sup +} and CO{sup +} is also explicitly determined to be 172.5°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel “correlated ion and neutral time of flight” method: Event-by-event detection of neutral and charged fragments in collision induced dissociation of mass selected ions

A new tandem mass spectrometry (MS/MS) method based on time of flight measurements performed on an event-by-event detection technique is presented. This “correlated ion and neutral time of flight” method allows to explore Collision Induced Dissociation (CID) fragmentation processes by directly identifying not only all ions and neutral fragments produced but also their arrival time correlations within each single fragmentation event from a dissociating molecular ion. This constitutes a new step in the characterization of molecular ions. The method will be illustrated here for a prototypical case involving CID of protonated water clusters H{sup +}(H{sub 2}O){sub n=1–5} upon collisions with argon atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collision dynamics of proton with formaldehyde: Fragmentation and ionization

Using time-dependent density functional theory, applied to the valence electrons and coupled non-adiabatically to molecular dynamics of the ions, we study the ionization and fragmentation of formaldehyde in collision with a proton. Four different impact energies: 35 eV, 85 eV, 135 eV, and 300 eV are chosen in order to study the energy effect in the low energy region, and ten different incident orientations at 85 eV are considered for investigating the steric effect. Fragmentation ratios, single, double, and total electron ionization cross sections are calculated. For large impact parameters, these results are close to zero irrespective of the incident orientations due to a weak projectile-target interaction. For small impact parameters, the results strongly depend on the collision energy and orientation. We also give the kinetic energy releases and scattering angles of protons, as well as the cross section of different ion fragments and the corresponding reaction channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A recoil ion momentum spectrometer for molecular and atomic fragmentation studies

We report the development and performance studies of a newly built recoil ion momentum spectrometer for the study of atomic and molecular fragmentation dynamics in gas phase upon the impact of charged particles and photons. The present design is a two-stage Wiley-McLaren type spectrometer which satisfies both time and velocity focusing conditions and is capable of measuring singly charged ionic fragments up-to 13 eV in all directions. An electrostatic lens has been introduced in order to achieve velocity imaging. Effects of the lens on time-of-flight as well as on the position have been investigated in detail, both, by simulation and in experiment. We have used 120 keV proton beam on molecular nitrogen gas target. Complete momentum distributions and kinetic energy release distributions have been derived from the measured position and time-of-flight spectra. Along with this, the kinetic energy release spectra of fragmentation of doubly ionized nitrogen molecule upon various projectile impacts are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗