Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAS EXPANSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Integrated Heat Switch/Oxide Sorption Compressor

Thermally-driven, nonmechanical compressor uses container filled with compressed praseodymium cerium oxide powder (PrCeOx) to provide high-pressure flow of oxygen gas for driving closed-cycle Joule-Thomson-expansion refrigeration unit. Integrated heat switch/oxide sorption compressor has no moving parts except check valves, which control flow of oxygen gas between compressor and closed-cycle Joule-Thomson refrigeration system. Oxygen expelled from sorbent at high pressure by evacuating heat-switch gap and turning on heater.

Bard, Steven↗

Airfoil sampling of a pulsed Laval beam with tunable vacuum ultraviolet (VUV) synchrotron ionization quadrupole mass spectrometry: Application to low--temperature kinetics and product detection

A new pulsed Laval nozzle apparatus with vacuum ultraviolet (VUV) synchrotron photoionization quadrupole mass spectrometry is constructed to study low-temperature radicalneutralchemical reactions of importance for modeling the atmosphere of Titan and the outer planets. A design for the sampling geometry of a pulsed Laval nozzle expansion has beendeveloped that operates successfully for the determination of rate coefficients by time-resolved mass spectrometry. The new concept employs airfoil sampling of the collimated expansion withexcellent sampling throughput. Time-resolved profiles of the high Mach number gas flow obtained by photoionization signals show that perturbation of the collimated expansion by theairfoil is negligible. The reaction of C2H with C2H2 is studied at 70 K as a proof-of-principle result for both low-temperature rate coefficient measurements and product identification basedon the photoionization spectrum of the reaction product versus VUV photon energy. This approach can be used to provide new insights into reaction mechanisms occurring at kinetic ratesclose to the collision-determined limit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vulcanian explosive eruptions: A mechanism for localised pyroclast dispersal on Venus

A model of the mechanisms involved in transient (vulcanian-type) explosive eruptions has enabled us to place constraints on the velocities of blocks ejected during such events on Earth as well as on the excess pressure and concentration of gas in the vent prior to the onset of the explosion. This model, suitably modified, can predict the results of similar eruptions occurring under the differing Venusian environmental conditions. It is found that the much higher atmospheric pressure (approximately 100 bars at the mean planetary radius) dominates the form of the resulting deposit in two main ways: (1) by inhibiting the expansion out of the vent of overpressured gas, hence reducing ejecta velocity; and (2) by retarding the flight of ejected blocks via drag effects. Thus, it is expected that such deposits will typically extend to approximately 200 m on Venus as compared to several km for documented terrestrial deposits.

Fagents, S. A.↗

Marcellus assessment shows continued expansion

Increasing uncertainty regarding the remaining volume of recoverable gas in Appalachian shale plays provided the original motivation for this study. Assessments of the Marcellus and Utica shale plays published by the US Geological Survey (USGS) in 2019 established resource volumes dramatically lower than ongoing well performance would indicate. Further, as production in the Marcellus increased and wells matured, operators observed that wells were producing more than the estimated gas-in-place (GIP).

03 NATURAL GAS↗

EFFECT OF HUMIDITY LEVEL ON THE CREEP PROPERTIES OF ALLOY 903 AT 650 C

Alloy 903 (FeNiCo+Nb) is currently used for certain components in industrial gas turbines for low coefficient of thermal expansion applications. A variance in creep behavior for material quality control evaluations suggested a possible effect of moisture level on stress rupture properties. To investigate the role of water vapor on the creep properties of alloy 903, controlled laboratory experiments were conducted at 650 C with 0 to 100% relative humidity. The water content was controlled by flowing dry air through a water bath at a constant temperature. A significant decrease of lifetime was observed in the presence of water vapor, which is likely related to grain boundary embrittlement by the inward diffusion of hydrogen. The increase of the microstructure grain aspect ratio by different forging processes generally improved the rupture lifetime and elongation in air. However, all specimens had reduced lifetime in the presence of water vapor despite the microstructure grain aspect ratios.

08 HYDROGEN↗

A compendium of multi-omic sequence information from the Saanich Inlet water column

Marine oxygen minimum zones (OMZs) are widespread regions of the ocean that are currently expanding due to global warming. While inhospitable to most metazoans, OMZs are hotspots for microbial mediated biogeochemical cycling of carbon, nitrogen and sulphur, contributing disproportionately to marine nitrogen loss and climate active trace gas production. Our current understanding of microbial community responses to OMZ expansion is limited by a lack of time-resolved data sets linking multi-omic sequence information (DNA, RNA, protein) to geochemical parameters and process rates. Here, we present six years of time-resolved multi-omic observations in Saanich Inlet, a seasonally anoxic fjord on the coast of Vancouver Island, British Columbia, Canada that undergoes recurring changes in water column oxygenation status. This compendium provides a unique multi-omic framework for studying microbial community responses to ocean deoxygenation along defined geochemical gradients in OMZ waters.

Hawley, Alyse K. (ORCID:0000000235164043)↗

Supersonic minimum length nozzle design for dense gases

Recently, dense gases have been investigated for many engineering applications such as for turbomachinery and wind tunnels. Supersonic nozzle design for these gases is complicated by their nonclassical behavior in the transonic flow regime. In this paper a method of characteristics (MOC) is developed for two-dimensional (planar) and, primarily, axisymmetric flow of a van der Waals gas. Using a straight aortic line assumption, a centered expansion is used to generate an inviscid wall contour of minimum length. The van der Waals results are compared to previous perfect gas results to show the real gas effects on the flow properties and inviscid wall contours.

Aldo, Andrew C.↗

A multi-scale study of the adsorption of lanthanum on the (110) surface of tungsten

In this study, we utilize a multi-scale approach to studying lanthanum adsorption on the (110) plane of tungsten. The energy of the system is described from density functional theory calculations within the framework of the cluster expansion method. It is found that including two-body figures up to the sixth nearest neighbor yielded a reasonable agreement with density functional theory calculations as evidenced by the reported cross validation score. The results indicate that the interaction between the adsorbate atoms in the adlayer is important and cannot be ignored. The parameterized cluster expansion expression is used in a lattice gas Monte Carlo simulation in the grand canonical ensemble at 773 K and the adsorption isotherm is recorded. Implications of the obtained results for the pyroprocessing application are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relaxation of an unsteady turbulent boundary layer on a flat plate in an expansion tube

An analysis is presented for the relaxation of a turbulent boundary layer on a semi-infinite flat plate after passage of a shock wave and a trailing driver gas-driven gas interface. The problem has special application to expansion-tube flows. The flow-governing equations have been transformed into the Crocco variables, and a time-similar solution is presented in terms of the dimensionless distance-time variable alpha and the dimensionless velocity variable beta. An eddy-viscosity model, similar to that of time-steady boundary layers, is applied to the inner and outer regions of the boundary layer. A turbulent Prandtl number equal to the molecular Prandtl number is used to relate the turbulent heat flux to the eddy viscosity. The numerical results, obtained by using the Gauss-Seidel line-relaxation method, indicate that a fully turbulent boundary layer relaxes faster to the final steady-state values of heat transfer and skin friction than a laminar boundary layer. The results also give a fairly good estimate of the local skin friction and heat transfer for near steady-flow conditions.

Gurta, R. N.↗

Observation of breakdown wave mechanism in avalanche ionization produced atmospheric plasma generated by a picosecond CO 2 laser

Understanding the formation and long-timescale evolution of atmospheric plasmas produced by ultrashort, long-wavelength infrared (LWIR) pulses is an important but partially understood problem. Of particular interest are plasmas produced in air with a peak laser intensity ~10 12 W/cm 2 , the so-called clamping intensity observed in LWIR atmospheric guiding experiments where tunneling and multi-photon ionization operative at near-IR or shorter wavelengths are inoperative. We find that avalanche breakdown on the surface of aerosol (dust) particles can act to seed the breakdown of air observed above the 200 GW/cm 2 threshold when a train of 3 ps 10.6 μm laser pulses separated by 18 ps is used. The breakdown first appears at the best focus but propagates backward toward the focusing optic as the plasma density approaches critical density and makes forward propagation impossible. The velocity of the backward propagating breakdown can be as high as 10 9 cm/s, an order of magnitude greater than measured with ns pulse-produced breakdown, and can be explained rather well by the so-called breakdown wave mechanism. Transverse plasma expansion with a similar velocity is assisted by UV photoionization and is observed as a secondary longitudinal breakdown mechanism in roughly 10% of the shots. When a cm-size, TW power beam is propagated, interception of aerosol particles is guaranteed and several (40 cm -3 ) breakdown sites appear, each initially producing a near-critical density plasma. On a 10 ns–1 μs timescale, shockwaves from each site expand radially and coalesce to produce a large hot gas channel. The radial velocity of the expansion agrees well with the prediction of the blast wave theory developed for ultrafast atmospheric detonations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Ultra-high temperature stability Joule-Thomson cooler with capability to accomodate pressure variations

A Joule-Thomson cryogenic refrigeration system capable of achieving high temperature stabilities in the presence of varying temperature, atmospheric pressure, and heat load is provided. The Joule-Thomson cryogenic refrigeration system includes a demand flow Joule-Thomson expansion valve disposed in a cryostat of the refrigeration system. The expansion valve has an adjustable orifice that controls the flow of compressed gas therethrough and induces cooling and partial liquefaction of the gas. A recuperative heat exchanger is disposed in the cryostat and coupled to the expansion valve. A thermostatically self-regulating mechanism is disposed in the cryostat and coupled to the J-T expansion valve. The thermostatically self-regulating mechanism automatically adjusts the cross sectional area of the adjustable valve orifice in response to environmental temperature changes and changes in power dissipated at a cold head. A temperature sensing and adjusting mechanism is coupled to a cold head for adjusting the temperature of the cold head in response to the change in heat flow in the cold head. The temperature sensing and adjusting mechanism comprises a temperature sensitive diode, a wound wire heater, and an electrical feedback control circuit coupling the diode to the heater. An absolute pressure relief valve is interposed between the output of the cryostat and an exhaust port for maintaining a constant exhaust temperature in the refrigerating system, independent of the changes in atmospheric pressure.

Bard, Steven↗

Nonadiabatic Energy Fluctuations of Scale-Invariant Quantum Systems in a Time-Dependent Trap

We consider the nonadiabatic energy fluctuations of a many-body system in a time-dependent harmonic trap. In the presence of scale-invariance, the dynamics becomes self-similar and the nondiabatic energy fluctuations can be found in terms of the initial expectation values of the second moments of the Hamiltonian, square position, and squeezing operators. Nonadiabatic features are expressed in terms of the scaling factor governing the size of the atomic cloud, which can be extracted from time-of-flight images. We apply this exact relation to a number of examples: the single-particle harmonic oscillator, the one-dimensional Calogero-Sutherland model, describing bosons with inverse-square interactions that includes the non-interacting Bose gas and the Tonks-Girdardeau gas as limiting cases, and the unitary Fermi gas. We illustrate these results for various expansion protocols involving sudden quenches of the trap frequency, linear ramps and shortcuts to adiabaticity. Our results pave the way to the experimental study of nonadiabatic energy fluctuations in driven quantum fluids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-temperature thermodynamics of strongly interacting s-wave and p-wave Fermi gases in a harmonic trap

We theoretically investigate the high-temperature thermodynamics of a strongly interacting trapped Fermi gas near either s-wave or p-wave Feshbach resonances, using a second-order quantum virial expansion. The second virial coefficient is calculated based on the energy spectrum of two interacting fermions in a harmonic trap. We consider both isotropic and anisotropic harmonic potentials. For the two-fermion interaction, either s-wave or p-wave, we use a pseudopotential parametrized by a scattering length and an effective range. This turns out to be the simplest way of encoding the energy dependence of the low-energy scattering amplitude or phase shift. This treatment of the pseudopotential can be easily generalized to higher partial-wave interactions. We discuss how the second virial coefficient and thermodynamics are affected by the existence of these finite-range interaction effects. The virial expansion result for a strongly interacting s-wave Fermi gas has already been proved very useful. In the case of p-wave interactions, our results for the high-temperature equation of state are applicable to future high-precision thermodynamic measurements for a spin-polarized Fermi gas near a p-wave Feshbach resonance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and testing of a passive, feedback-controlled, variable conductance heat pipe

A passive feedback system, which stabilizes the heat source temperature (T sub s) of a gas loaded heat pipe, was designed and tested. The control of T sub s is accomplished by an auxiliary liquid that senses the heat source and actuates a metal bellows system due to the liquid's thermal expansion. The movement of the bellows varies the gas reservoir volume and leads to a corresponding change of the condensation area of the heat pipe. With methanol as the heat pipe working fluid and perfluoro-n-pentane as the auxiliary liquid, the control capability was found to be T sub s = 31.5 + or - 1.5 C in a power range from 3 to 30 W, compared to T sub s = 33 + or - 3 C with methanol as auxiliary liquid. The change in T sub s was 35 + or - 5.5 C with the bellows held in the closed position.

Schlitt, K. R.↗

Partially ionized gas flow and heat transfer in the separation, reattachment, and redevelopment regions downstream of an abrupt circular channel expansion.

Heat transfer and pressure measurements obtained in the separation, reattachment, and redevelopment regions along a tube and nozzle located downstream of an abrupt channel expansion are presented for a very high enthalpy flow of argon. The ionization energy fraction extended up to 0.6 at the tube inlet just downstream of the arc heater. Reattachment resulted from the growth of an instability in the vortex sheet-like shear layer between the central jet that discharged into the tube and the reverse flow along the wall at the lower Reynolds numbers, as indicated by water flow visualization studies which were found to dynamically model the high-temperature gas flow. A reasonably good prediction of the heat transfer in the reattachment region where the highest heat transfer occurred and in the redevelopment region downstream can be made by using existing laminar boundary layer theory for a partially ionized gas. In the experiments as much as 90 per cent of the inlet energy was lost by heat transfer to the tube and the nozzle wall.

Back, L. H.↗

Interaction of the solar wind with the neutral component of the interstellar gas.

A model is constructed to represent the interaction between the solar wind and the neutral component of the interstellar gas. It is found that the neutral gas has several important effects on the solar-wind expansion beyond the orbit of the earth and that it should be possible to infer the presence of the neutral gas from observations of the solar wind made by a space probe traveling into the outer solar system. The effects include a deceleration and heating of the supersonic solar wind, a cooling of and pressure reduction in the subsonic solar wind, and a tightening of the spiral magnetic field in the supersonic solar wind.

Holzer, T. E.↗