Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 Degree-Sign of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D printer generated thorax phantom with mobile tumor for radiation dosimetry

This article describes the design, construction, and properties of an anthropomorphic thorax phantom with a moving surrogate tumor. This novel phantom permits detection of dose both inside and outside a moving tumor and within the substitute lung tissue material. A 3D printer generated the thorax shell composed of a chest wall, spinal column, and posterior regions of the phantom. Images of a computed tomography scan of the thorax from a patient with lung cancer provided the template for the 3D printing. The plastic phantom is segmented into two materials representing the muscle and bones, and its geometry closely matches a patient. A surrogate spherical plastic tumor controlled by a 3D linear stage simulates a lung tumor’s trajectory during normal breathing. Sawdust emulates the lung tissue in terms of average and distribution in Hounsfield numbers. The sawdust also provides a forgiving medium that permits tumor motion and sandwiching of radiochromic film inside the mobile surrogate plastic tumor for dosimetry. A custom cork casing shields the film and tumor and eliminates film bending during extended scans. The phantom, lung tissue surrogate, and radiochromic film are exposed to a seven field plan based on an ECLIPSE plan for 6 MV photons from a Trilogy machine delivering 230 cGy to the isocenter. The dose collected in a sagittal plane is compared to the calculated plan. Gamma analysis finds 8.8% and 5.5% gamma failure rates for measurements of large amplitude trajectory and static measurements relative to the large amplitude plan, respectively. These particular gamma analysis results were achieved using parameters of 3% dose and 3 mm, for regions receiving doses >150 cGy. The plan assumes a stationary detection grid unlike the moving radiochromic film and tissues. This difference was experimentally observed and motivated calculated dose distributions that incorporated the phase of the tumor periodic motion. These calculations modestly improve agreement between the measured and intended doses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution Gamma Spectroscopy Measurements of Pressurized Water Reactor Spent Nuclear Fuel Rods

International nuclear safeguards use nondestructive assay techniques to verify declared characteristics of spent nuclear fuel (SNF) assemblies. The declared characteristics usually include the initial enrichment, assembly average burnup, and irradiation history. The primary nondestructive assay tool used by the International Atomic Energy Agency has been the fork detector irradiated fuel measurement system, which uses gross gamma and neutron correlations; however, there have been several research publications within the last decade on the use of high-resolution gamma spectroscopy for the determination of SNF characteristics. References [1]–[6] are published journal articles on this subject from 2006–2016. This report describes measurements of 25 individual SNF rods using high-resolution gamma spectroscopy. Details of the measurement geometry, measurement settings, and rod characteristics are documented. These spectra are intended for the validation of simulation codes that calculate SNF inventory and source term characteristics. The spectrum archive is available to evaluate future spectrum analysis methods. The archive contains full axial scan spectra of each SNF rod. This allows more detailed comparison between simulation and nondestructive analysis than is possible on assemblies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar gamma ray monitor for OSO-H (0.3-10 MeV)

A gamma ray experiment to be flown aboard the OSO-7 spacecraft is described along with a history of the development of the experiment, a description of the gamma ray detector and its operation, and a short preliminary review of the scientific information obtained during the instruments' lifetime. The gamma ray detector operated an average of 18 hours a day for approximately 15 months. The majority of the data was collected in the solar and antisolar direction, but data at right angles to the spacecraft-sun line was also accumulated. In all, at least two full scans of the celestial sphere were completed.

Chupp, E. L.↗

Prototype Radiation Detector Positioning System For The Automated Nondestructive Assay Of Uf6 Cylinders

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility’s entire cylinder inventory. These measurements are time-consuming, expensive, and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of efficiency and assay accuracy. This paper describes an approach denoted the Integrated Cylinder Verification Station (ICVS) that supports 100% cylinder verification, provides volume-averaged cylinder enrichment assay, and reduces inspector manpower needs. To allow field measurements to be collected to validate data collection algorithms, a prototype radiation detector positioning system was constructed. The system was designed to accurately position an array of radiation detectors along the length of a cylinder to measure UF6 enrichment. A number of alternative radiation shields for the detectors were included with the system. A collimated gamma-ray spectrometer module that allows translation of the detectors in the surrounding shielding to adjust the field of view, and a collimating plug in the end to further reduce the low-energy field of view, were also developed. Proof-of-principle measurements of neutron and high-energy gamma-ray signatures, using moderated neutron detectors and large-volume spectrometers in a fixed-geometry, portal-like configuration, supported an early assessment of the viability of the concept. The system has been used successfully on two testing campaigns at an AREVA fuel fabrication plant to scan over 30 product cylinders. This paper will describe the overall design of the detector positioning system and provide an overview of the Integrated Cylinder Verification Station (ICVS) approach.

assay↗

TH-CD-202-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Evaluation of the Use of Direct Electron Density CT Images in Radiation Therapy

Purpose: The current standard for calculation of photon and electron dose requires conversion of Hounsfield Units (HU) to Electron Density (ED) by applying a calibration curve specifically constructed for the corresponding CT tube voltage. This practice limits the use of the CT scanner to a single tube voltage and hinders the freedom in the selection of optimal tube voltage for better image quality. The objective of this study is to report a prototype CT reconstruction algorithm that provides direct ED images from the raw CT data independently of tube voltages used during acquisition. Methods: A tissue substitute phantom was scanned for Stoichiometric CT calibrations at tube voltages of 70kV, 80kV, 100kV, 120kV and 140kV respectively. HU images and direct ED images were acquired sequentially on a thoracic anthropomorphic phantom at the same tube voltages. Electron densities converted from the HU images were compared to ED obtained from the direct ED images. A 7-field treatment plan was made on all HU and ED images. Gamma analysis was performed to demonstrate quantitatively dosimetric change from the two schemes in acquiring ED. Results: The average deviation of EDs obtained from the direct ED images was −1.5%±2.1% from the EDs from HU images with the corresponding CT calibration curves applied. Gamma analysis on dose calculated on the direct ED images and the HU images acquired at the same tube voltage indicated negligible difference with lowest passing rate at 99.9%. Conclusion: Direct ED images require no CT calibration while demonstrate equivalent dosimetry compared to that obtained from standard HU images. The ability of acquiring direct ED images simplifies the current practice at a safer level by eliminating CT calibration and HU conversion from commissioning and treatment planning respectively. Furthermore, it unlocks a wider range of tube voltages in CT scanner for better imaging quality while maintaining similar dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Microstructure of selective laser melted CM247LC nickel-based superalloy and its evolution through heat treatment

The selective laser melting of high temperature alloys is of great interest to the aerospace industry as it offers the prospect of producing more complex geometries than can be achieved with other manufacturing methods. In this study, the microstructure of the nickel-based superalloy, CM247LC, has been characterised following selective laser melting and after a post deposition heat treatment below the γ′ solvus temperature. In the as-deposited state, scanning electron microscopy with electron backscatter diffraction revealed a fine, cellular microstructure with preferential alignment of 〈001〉 along the build direction. A high dislocation density was seen at the periphery of the cells, indicating substantial localised deformation of the material. Fine primary MC carbides were also observed in the inter-cellular regions. High-resolution transmission electron microscopy identified the occurrence of very fine γ′ precipitates, approximately 5 nm in diameter, dispersed within the gamma phase. After heat treatment, the elongated cell colonies were observed to partially coalesce, accompanied by a decrease in dislocation density, producing columnar grains along the build direction. Cuboidal γ′ precipitates approximately 500 nm in diameter were observed to form in the recrystallised grains, accompanied by larger γ′ precipitates on the grain boundaries.

36 MATERIALS SCIENCE↗

Development of Monitoring & Verification Technology (MVT) for Carbon Sequestration in Terrestrial Ecosystems: Instrumentation and Protocols

The objective of this CRADA is to further develop the Multiple Elemental Soil Analysis (MESA) system, based on inelastic neutron scattering technology that was originally developed by Dr. Lucian Wielopolski at BNL. The scope of this CRADA will center on the quantification and monitoring of non-destructive in situ carbon loading in soils to evaluate land application emission reduction activities. To accomplish this objective, the CRADA will center on three main joint activities as described below: A. To further develop and characterize a prototype, field deployable MESA system for static and scanning purposes. B. To develop applicable protocols for agricultural land applications; system validation and field sampling schemes. C. To implement field experiments for independent systems validation, verification, and acceptance by third parties for use in the market segment and commercialization. The technical approach involves a system for monitoring characteristic gamma rays emitted from carbon nuclei stimulated by inelastic neutron scattering from a carbon nucleus. The system consists of a neutron generator emitting fast, 14 MeV, neutrons, shielding materials, and a detection system with nuclear electronics for data acquisition. Following standard system calibration, the results are produced immediately at the end of the counting period.

54 ENVIRONMENTAL SCIENCES↗

The relative line strength and intensity of the N II 2143 doublet

The doublet emission from N II at 2139.7 A and 2143.6 A was observed by a 1.4-m scanning spectrometer with 3.1 A resolution in the daytime, high-altitude thermosphere during moderate levels of solar activity. The spectrometer viewed the earth's limb 5 deg below the local horizontal to give a nominal tangent height of 152 km. Both sub band heads of the nitric oxide gamma band system were resolved in the data at the resolution used. The emission features from N II are clearly evident on the short wavelength shoulder of the (1, 0) band. Synthetic profiles of the (1, 0) gamma band and the (0, 3) delta band of nitric oxide were fitted to the data using a chi-square analysis. These contributions were removed from the data leaving a residual emission, considered to be the N II doublet. A chi-square minimization of the data relative to a synthetic intensity profile was done. The minimum was for a line strength ratio between the 2139 A and 2143 A lines of 0.58 + or - 0.08. The mean solar EUV flux deduced from the intensity of the N II emission in this experiment is lower than other reported observations, consistent with a lower solar activity level.

Bucsela, Eric J.↗

Effects of a Tantalum Addition on the Morphological and Compositional Evolutions of a Model Ni-AL-Cr Superalloy

The effects of a 2.0 at.% addition of Ta to a model Ni-Al-Cr superalloy aged at 1073 K are assessed using scanning electron microscopy and atom-probe tomography. The addition of Ta results in appreciable strengthening, and the morphology is found to evolve from a bimodal distribution of spheroidal precipitates, to cuboidal precipitates aligned along the elastically soft <001>-type directions. Tantalum is observed to partition preferentially to the gamma -precipitate phase and decreases the mobility of Ni in the gamma- matrix sufficiently to cause an accumulation of Ni on the gamma-matrix side of the gamma -precipitate/gamma-matrix heterophase interface.

Booth-Morrison, Christopher↗

Nanoparticles assembly of boehmite nanofibers without a surfactant

Self-assembly of aluminum hydrate particles into larger boehmite ({gamma}-AlOOH) nanofibers was illustrated by a facile hydrothermal method without using any surfactants. The size and morphology of boehmite nanofibers could be controlled by adjusting the pH value of the reaction mixture. The resulting products were characterized by XRD (X-ray diffraction), FTIR (Fourier transform infrared spectra), SEM (scanning electron microscopy), and TEM (transmission electron microscopy). The specific surface area and pore-size distribution of the obtained product as determined by gas-sorption measurements show that the boehmite nanofibers possess high-surface area and porosity properties. A possible formation mechanism of nanofibers via a nanoparticle assembly procedure is proposed based on the experiments under the different conditions.

36 MATERIALS SCIENCE↗

{gamma}-MnS nano and micro architectures: Synthesis, characterization and optical properties

Highlights: {yields} In this article we have reported the formation of {gamma}-MnS nano/microcrystalline material by a novel proposed route. Na{sub 2}[Mn(HL){sub 2}(H{sub 2}O){sub 2}]; 1:2 (M:L) chelate complex was synthesized in the first step by our previously reported method. The chelate complex precursor was subsequently decomposed by alkaline solution of thiocarbamide, resulting formation of {gamma}-MnS crystals in situ. {yields} The effect of reaction time and surfactant have been observed and discussed. The materials were characterized for crystallanity and morphology by SEM, TEM, XRD, UV-Vis, PL spectra and the results are thoroughly discussed. {yields} {gamma}-MnS crystals were formed when metal complex was used as metal source whereas Mn{sub 3}O{sub 4} was the dominant product when MnSO{sub 4}.H{sub 2}O was used as metal source. {yields} We have also proposed a plausible formation mechanism based on experimental evidence, analyses and previous reports. {yields} Optical property of the material has also been discussed in the present article. -- Abstract: {gamma}-MnS nanocrystalline materials have been prepared by reaction of Na{sub 2}[Mn(HL){sub 2}(H{sub 2}O){sub 2}]; 1:2 (M:L) chelate complex with alkaline solution of thiocarbamide in aqueous solution phase. Effect of metal chelate complex, reaction time and surfactant sodium dodecyl sulfate; SDS on phase, morphology and size of the products have been investigated. The metal chelate complex was synthesized by reacting Mn(II) ions with eriochrome black T (NaH{sub 2}L) in alkaline medium. {gamma}-MnS crystals were formed when metal complex was used as metal source whereas Mn{sub 3}O{sub 4} was the dominant product when MnSO{sub 4}.H{sub 2}O was used as metal source. Materials thus formed having various morphologies were characterized by X-ray diffraction, scanning electron microscopy (SEM), transmission electron microscopy (TEM) to determine the crystallinity, phase, structure and morphology. The optical properties of the thus prepared samples were determined by UV-vis absorption spectra and photoluminescence spectra. A possible formation mechanism of crystals has been discussed in this article.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-BRD-08: End-To-End Targeting Accuracy of the Gamma Knife for Trigeminal Neuralgia

Purpose: Current QA procedures verify accuracy of individual equipment parameters, but may not include CT and MRI localizers. This study uses an end-to-end approach to measure the overall targeting errors in individual patients previously treated for trigeminal neuralgia. Methods: The trigeminal nerve is simulated by a 3 mm long, 3.175 mm (1/8 inch) diameter MRI contrast-filled cavity embedded within a PMMA plastic capsule. The capsule is positioned within the head frame such that the cavity position matches the Gamma Knife coordinates of 10 previously treated patients. Gafchromic EBT2 film is placed at the center of the cavity in coronal and sagittal orientations. The films are marked with a pin prick to identify the cavity center. Treatments are planned for delivery with 4 mm collimators using MRI and CT scans acquired with the clinical localizer boxes and acquisition protocols. Coordinates of shots are chosen so that the cavity is centered within the 50% isodose volume. Following irradiation, the films are scanned and analyzed. Targeting errors are defined as the distance between the pin prick and the centroid of the 50% isodose line. Results: Averaged over 10 patient simulations, targeting errors along the x, y and z coordinates (patient left-to-right, posterior-anterior, head-to-foot) were, respectively, −0.060 +/− 0.363, −0.350 +/− 0.253, and 0.364 +/− 0.191 mm when MRI was used for treatment planning. Planning according to CT exhibited generally smaller errors, namely 0.109 +/− 0.167, −0.191 +/− 0.144, and 0.211 +/− 0.94 mm. The largest errors in MRI and CT planned treatments were, respectively, y = −0.761 and x = 0.428 mm. Conclusion: Unless patient motion or stronger MRI image distortion in actual treatments caused additional errors, all patients received the prescribed dose, i.e., the targeted section of the trig±eminal nerve was contained within the 50% isodose surface in all cases.

60 APPLIED LIFE SCIENCES↗

SU-E-T-815: In Vivo Dosimetry and Daily Arc Junction Verification Using EBT3 Gafchromic Film for Pediatric Cranio-Spinal Irradiation

Purpose: Perform dosimetric comparison between planned and delivered dose in the junction area, measure daily dose variation in the arc junction area for pediatric patients treated for medulloblastoma using Craniospinal axis irradiation(CSI) Material and methods Dose comparison in the junction area, daily dose variation in the arc junction area for a Rando Phantom and 5 pediatric patients treated using CSI technique were analyzed. Plans were created using the Eclipse treatment planning system. Two arcs for cranium and 1 arc for spine region were used. Planar dose matrix was created by projecting phantom and patient plan into the ArcCheck phantom. EBT3 film was placed in the middle of ArcCheck plug to measure dose distribution in the junction areaDuring patient treatment, strip of EBT3 film was placed daily at each junction area for verification. EBT3 films were scanned using a flatbed scanner, Epson Expression 10000 XL. Film QA pro software was used to analyze film. Scanning and analysis was performed according to vendor recommendations and AAPM TG-55 report. Films were scanned and analyzed daily after each treatment and at the end of treatment course. Planar dose distributions from films were compared with planar dose distribution from treatment planning system. Results: Comparison of planned vs. measured dose distributions for patients have passing rates of 90%–100% with 3% and 3 mm gamma analysis. In some of the treatment fractions, daily setup film showed variation in dose distribution in the junction area. Conclusion: It is critical to measure dose distribution in the arc junction area and use additional quality assurance measures to verify daily setup for CSI patient where one or more junctions are present. EBT3 film prove to be a good tool to achieve this task considering flexibility associated with the film such as symmetry, self-developing and ease of use.

60 APPLIED LIFE SCIENCES↗

SU-F-T-410: Investigation of Treatment Planning Accuracy with the Presence of Magnetic Injection Port (breast Tissue Expander)

Purpose: Mastectomy patients with breast reconstruction usually have a magnetic injection port inside the breast during radiation treatments. The magnet has a very high CT number and produces severe streaking artifact across the entire breast in CT images. Our routine strategy is to replace the artifact volumes with uniform water, and it is necessary to validate that the planned dose, with such an artifact correction, is sufficiently accurate. Methods: A phantom was made with a gelatine-filled container sitting on a Matrixx detector, and the magnetic port was inserted into gelatine with specific depths and orientations. The phantom was scanned on a CT simulator and imported into Eclipse for treatment planning. The dose distribution at the Matrixx detector plane was calculated for raw CT images and artifact-corrected images. The treatment beams were then delivered to the phantom and the dose distributions were acquired by the Matrixx detector. Gamma index was calculated to compare the planned dose and the measurement. Results: Three field sizes (10×10, 15×15 and 20×20) and two depths (50mm and 20mm) were investigated. With the 2%/2mm or 3%/3mm criteria, several points (6–10) failed in the plan for raw CT images, and the number of failure was reduced close to zero for the corrected CT images. An assignment of 10,000 HU to the magnet further reduced the dose error directly under the magnet. Conclusion: It is validated that our routine strategy of artifact correction can effectively reduce the number of failures in the detector plane. It is also recommended to set the magnet with a CT number of 10,000HU, which could potentially improve the dose calculation at the points right behind the magnet.

60 APPLIED LIFE SCIENCES↗

Quantitative Laser-Saturated Fluorescence Measurements of Nitric Oxide in a Heptane Spray Flame

We report spatially resolved laser-saturated fluorescence measurements of NO concentration in a pre-heated, lean-direct injection (LDI) spray flame at atmospheric pressure. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q2(26.5) transition of the gamma(0,0) band. Detection is performed in a 2-nm region centered on the gamma(0,1) band. Because of the relatively close spectral spacing between the excitation (226 nm) and detection wavelengths (236 nm), the gamma(0,1) band of NO cannot be isolated from the spectral wings of the Mie scattering signal produced by the spray. To account for the resulting superposition of the fluorescence and scattering signals, a background subtraction method has been developed that utilizes a nearby non-resonant wavelength. Excitation scans have been performed to locate the optimum off-line wavelength. Detection scans have been performed at problematic locations in the flame to determine possible fluorescence interferences from UHCs and PAHs at both the on-line and off-line excitation wavelengths. Quantitative radial NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors.

Cooper, Clayton S.↗

Exchange Coupling Nanophase Fe-Pd Ferromagnets Through Solid State Transformation

This study continues previous work on off stoichiometric Fe-Pd alloys using a combined reaction strategy during thermomechanical processing [1,2]. Severe plastic deformation of the initial disordered fcc gamma phase ( ), followed by heat treatment in the two phase field produces a nano-composite ferromagnet comprised of soft alpha-Fe/ferrite in a high-anisotropy L10 FePd matrix. The length scale and morphology of the transformation products have been characterized using x-ray diffraction, and scanning and transmission electron microscopy. The transformed microstructures exhibit strong texture retention similar to the stoichiometric alloy suggesting a massive ordering mode. The alloy has shown a proclivity to exchange couple at a length scale not in agreement with proposed theories of exchange coupling [3,4]. The magnetic properties were measured using standard vibrating sample magnetometry (VSM). This research has been supported by the National Science Foundation (NSF-DMR).

36 MATERIALS SCIENCE↗

Microstructure and Mechanical of U-6Nb and U-8Nb in Gamma Quenched and Long-Term Aged Conditions

This report documents the mechanical response and associated microstructure in a number of recent Los Alamos studies of U-6Nb and U-8Nb alloys in the as-quenched and artificially aged conditions, to serve as a primary data reference. Quasi-static tensile and hardness data (in the form of averages) are reported along with microstructures revealed by light optical and scanning electron microscopy. Total elongation data were converted to a common standard for ease of comparison of data from different tensile specimen geometries. A variety of alternate measures of total tensile elongation confirmed the trends one would find from considering only extensometer data. The various U-Nb material pedigrees and experimental conditions are as follows. Y-12-produced U-6Nb as quenched – effect of machining damage as quenched – effect of extensometer length 200oC ages for up to 22 days Rocky Flats-produced U-6Nb 40, 65, and 90oC ages for up to 10 years 300, 350, and 400°C ages for up to 1.2 years Los Alamos-produced nonbanded U-5.6Nb and U-7.7Nb variety of ages over 100-600°C for up to 5 years We characterized the chemical banding by microprobe and Knoop microhardness surveyed over long regions in a dozen Y-12 U-6Nb specimens. As expected, the light-vs.-dark imaging response (both by light optical and scanning electron microscopy) correlated well with the local wt.% Nb. However, the hardness did not correlate well with either imaging or microprobe, and hence cannot be used to predict the local wt.% Nb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗