High-intensity tone generation by aeroacoustic sources

An experimental investigation has been carried out on the production of high-intensity tones by axisymmetric ring cavities. Maximum sound production occurs during an acoustic resonance at Strouhal numbers, which depend only on the local flow velocity independent of cavity location. Values of sound pressure of about 115 dB at 1-m distance can be generated by axisymmetric ring cavities on projectiles moving at a relatively low flight speed equal to 70 m/s. Frequencies in the audible range up to several kilohertz can be generated aeroacoustically. A simple analytical model has been developed to explain the experimental observations.

Shakkottai, P.↗

Free-Space Quantum Key Distribution with a High Generation Rate Potassium Titanyl Phosphate Waveguide Photon-Pair Source

A high generation rate photon-pair source using a dual element periodically-poled potassium titanyl phosphate (PP KTP) waveguide is described. The fully integrated photon-pair source consists of a 1064-nanometer pump diode laser, fiber-coupled to a dual element waveguide within which a pair of 1064-nanometer photons are up-converted to a single 532-nanometer photon in the first stage. In the second stage, the 532-nanometer photon is down-converted to an entangled photon-pair at 800 nanometer and 1600 nanometer which are fiber-coupled at the waveguide output. The photon-pair source features a high pair generation rate, a compact power-efficient package, and continuous wave (CW) or pulsed operation. This is a significant step towards the long term goal of developing sources for high-rate Quantum Key Distribution (QKD) to enable Earth-space secure communications. Characterization and test results are presented. Details and preliminary results of a laboratory free-space QKD experiment with the B92 protocol are also presented.

photons↗

In-situ synchrotron x-ray characterization of K 2 CsSb photocathode grown by ternary co-evaporation

K2CsSb is a promising photocathode candidate to serve as an electron source in next-generation light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). As the traditional recipe for creation of K2CsSb photocathodes typically results in a rough surface that deteriorates electron beam quality, significant effort has been made to explore novel growth methods for K2CsSb photocathodes. In this paper, a method of ternary co-evaporation of K, Cs, and Sb is described. By using in-situ synchrotron X-ray techniques, the quality of the photocathode is characterized during and after the growth. K2CsSb photocathodes grown by this method on Si (100) and MgO (001) substrates show strong (222) texture, and the two photocathodes exhibit 1.7% and 3.4% quantum efficiencies at a wavelength of 530 nm, with a rms surface roughness of about 2-4 nm. This represents an order of magnitude reduction in roughness compared to typical sequential deposition and should result in a significant improvement in the brightness of the generated electron beam.

Ding, Z.↗

Vacuum space-charge effects in solid-state photoemission

Solid-state photoemission spectroscopy relies to a large part on pulsed photon sources: third-generation synchrotron-radiation sources and ultrafast laser systems in particular. Especially when the photon pulses are intense, Coulombic repulsion between the emitted electrons will be a limiting factor for photoemission experiments aiming at highest energy and angle resolutions. In the present work, the propagation of the photoelectron cloud to the detector is studied with a full N-body numerical simulation. The influence of various parameters, in particular number of electrons per pulse, source size, pulse duration, kinetic-energy and emission-angle distributions as well as presence of mirror charges in the sample, is investigated in detail. Previous experimental results obtained with various picosecond and femtosecond light sources are successfully reproduced and the general resolution limits of solid-state photoemission using pulsed photon sources are explored. The results are potentially important for the design and interpretation of photoemission experiments with next-generation light sources, such as free-electron lasers and high-harmonic generation sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Next Generation H- Ion Sources for the SNS

The U.S. Spallation Neutron Source (SNS) is the leading accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to insure meeting operational requirements as well as providing for future facility beam power upgrades, a multifaceted H{sup -} ion source development program is ongoing. This work discusses several aspects of this program, specifically the design and first beam measurements of an RF-driven, external antenna H{sup -} ion source based on an AlN ceramic plasma chamber, elemental and chromate Cs-systems, and plasma ignition gun. Unanalyzed beam currents of up to {approx}100 mA (60Hz, 1ms) have been observed and sustained currents >60 mA (60Hz, 1ms) have been demonstrated on the test stand. Accelerated beam currents of {approx}40 mA have also been demonstrated into the SNS front end. Data are also presented describing the first H{sup -} beam extraction experiments from a helicon plasma generator based on the Variable Specific Impulse Magnetoplasma Rocket (VASIMR) engine design.

33 ADVANCED PROPULSION SYSTEMS↗

Burnup calculations for KIPT accelerator driven subcritical facility using Monte Carlo computer codes-MCB and MCNPX.

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of an electron accelerator driven subcritical (ADS) facility, using the KIPT electron accelerator. The neutron source of the subcritical assembly is generated from the interaction of 100 KW electron beam with a natural uranium target. The electron beam has a uniform spatial distribution and electron energy in the range of 100 to 200 MeV. The main functions of the subcritical assembly are the production of medical isotopes and the support of the Ukraine nuclear power industry. Neutron physics experiments and material structure analyses are planned using this facility. With the 100 KW electron beam power, the total thermal power of the facility is {approx}375 kW including the fission power of {approx}260 kW. The burnup of the fissile materials and the buildup of fission products reduce continuously the reactivity during the operation, which reduces the neutron flux level and consequently the facility performance. To preserve the neutron flux level during the operation, fuel assemblies should be added after long operating periods to compensate for the lost reactivity. This process requires accurate prediction of the fuel burnup, the decay behavior of the fission produces, and the introduced reactivity from adding fresh fuel assemblies. The recent developments of the Monte Carlo computer codes, the high speed capability of the computer processors, and the parallel computation techniques made it possible to perform three-dimensional detailed burnup simulations. A full detailed three-dimensional geometrical model is used for the burnup simulations with continuous energy nuclear data libraries for the transport calculations and 63-multigroup or one group cross sections libraries for the depletion calculations. Monte Carlo Computer code MCNPX and MCB are utilized for this study. MCNPX transports the electrons and the produced neutrons and photons but the current version of MCNPX doesn't support depletion/burnup calculation of the subcritical system with the generated neutron source from the target. MCB can perform neutron transport and burnup calculation for subcritical system using external neutron source, however it cannot perform electron transport calculations. To solve this problem, a hybrid procedure is developed by coupling these two computer codes. The user tally subroutine of MCNPX is developed and utilized to record the information of the each generated neutron from the photonuclear reactions resulted from the electron beam interactions. MCB reads the recorded information of each generated neutron thorough the user source subroutine. In this way, the neutron source generated by electron reactions could be utilized in MCB calculations, without the need for MCB to transport the electrons. Using the source subroutines, MCB could get the external neutron source, which is prepared by MCNPX, and perform depletion calculation for the driven subcritical facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of extreme ultraviolet and soft x-ray multilayer optics for scientific studies with femtosecond/attosecond sources

The development of multilayer optics for extreme ultraviolet (EUV) radiation has led to advancements in many areas of science and technology, including materials studies, EUV lithography, water window microscopy, plasma imaging, and orbiting solar physics imaging. Recent developments in femtosecond and attosecond EUV pulse generation from sources such as high harmonic generation lasers, combined with the elemental and chemical specificity provided by EUV radiation, are opening new opportunities to study fundamental dynamic processes in materials. Critical to these efforts is the design and fabrication of multilayer optics to transport, focus, shape and image these ultra-fast pulses This thesis describes the design, fabrication, characterization, and application of multilayer optics for EUV femtosecond and attosecond scientific studies. Multilayer mirrors for bandwidth control, pulse shaping and compression, tri-material multilayers, and multilayers for polarization control are described. Characterization of multilayer optics, including measurement of material optical constants, reflectivity of multilayer mirrors, and metrology of reflected phases of the multilayer, which is critical to maintaining pulse size and shape, were performed. Two applications of these multilayer mirrors are detailed in the thesis. In the first application, broad bandwidth multilayers were used to characterize and measure sub-100 attosecond pulses from a high harmonic generation source and was performed in collaboration with the Max-Planck institute for Quantum Optics and Ludwig- Maximilians University in Garching, Germany, with Professors Krausz and Kleineberg. In the second application, multilayer mirrors with polarization control are useful to study femtosecond spin dynamics in an ongoing collaboration with the T-REX group of Professor Parmigiani at Elettra in Trieste, Italy. As new ultrafast x-ray sources become available, for example free electron lasers, the multilayer designs described in this thesis can be extended to higher photon energies, and such designs can be used with those sources to enable new scientific studies, such as molecular bonding, phonon, and spin dynamics.

36 MATERIALS SCIENCE↗

Colliding laser-produced plasmas as targets for laser-generated extreme ultraviolet sources

Colliding plasmas produced by neodymium-doped yttrium aluminium garnet (Nd:YAG) laser illumination of tin wedge targets form stagnation layers, the physical parameters of which can be controlled to optimise coupling with a carbon dioxide (CO{sub 2}) heating laser pulse and subsequent extreme ultraviolet (EUV) production. The conversion efficiency (CE) of total laser energy into EUV emission at 13.5 nm ± 1% was 3.6%. Neglecting both the energy required to form the stagnation layer and the EUV light produced before the CO{sub 2} laser pulse is incident results in a CE of 5.1% of the CO{sub 2} laser energy into EUV light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wavelength scaling and multicolor operation of a plasma-driven attosecond x-ray source via harmonic generation

The generation of high-power coherent soft x-ray pulses of sub-100 as duration and 10 nm wavelength using beams from a GeV energy plasma wakefield accelerator has been recently investigated in Emma []. As a future upgrade to this concept, this contribution investigates scaling to shorter x-ray wavelengths by cascading undulators tuned to higher harmonics of the fundamental. We present two simulation studies for plasma-driven attosecond harmonic generation schemes with final photon wavelengths of 2 and 0.40 nm. We demonstrate in these schemes that using undulators with retuned fundamental frequencies can produce GW-scale pulses of sub-nm radiation with tens of attosecond-scale pulse lengths, an order of magnitude shorter than current state-of-the-art attosecond x-ray free electron lasers (XFELs). This multipulse multicolor operation will be broadly applicable to attosecond pump-probe experiments. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability

Purpose: The purpose of this work was to assess the inherent image quality characteristics of a new multidetector computed tomography system in terms of noise, resolution, and detectability index as a function of image acquisition and reconstruction for a range of clinically relevant settings. Methods: A multisized image quality phantom (37, 30, 23, 18.5, and 12 cm physical diameter) was imaged on a SOMATOM Force scanner (Siemens Medical Solutions) under variable dose, kVp, and tube current modulation settings. Images were reconstructed with filtered back projection (FBP) and with advanced modeled iterative reconstruction (ADMIRE) with iterative strengths of 3, 4, and 5. Image quality was assessed in terms of the noise power spectrum (NPS), task transfer function (TTF), and detectability index for a range of detection tasks (contrasts of approximately 45, 90, 300, −900, and 1000 HU, and 2–20 mm diameter) based on a non-prewhitening matched filter model observer with eye filter. Results: Image noise magnitude decreased with decreasing phantom size, increasing dose, and increasing ADMIRE strength, offering up to 64% noise reduction relative to FBP. Noise texture in terms of the NPS was similar between FBP and ADMIRE (<5% shift in peak frequency). The resolution, based on the TTF, improved with increased ADMIRE strength by an average of 15% in the TTF 50% frequency for ADMIRE-5. The detectability index increased with increasing dose and ADMIRE strength by an average of 55%, 90%, and 163% for ADMIRE 3, 4, and 5, respectively. Assessing the impact of mA modulation for a fixed average dose over the length of the phantom, detectability was up to 49% lower in smaller phantom sections and up to 26% higher in larger phantom sections for the modulated scan compared to a fixed tube current scan. Overall, the detectability exhibited less variability with phantom size for modulated scans compared to fixed tube current scans. Conclusions: Image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose. The use of tube current modulation resulted in more consistent image quality with changing phantom size.

60 APPLIED LIFE SCIENCES↗

Hard X-Ray Photon Correlation Spectroscopy Methods for Materials Studies

Understanding and designing sophisticated new materials require measurements of not only their average structural properties but also their dynamic behavior. X-ray photon correlation spectroscopy (XPCS) provides this information by characterizing fluctuations in condensed matter across a broad range of length scales and timescales. Over the past two decades, XPCS has provided a wide variety of results in the study of materials properties. In this review, we provide an overview of coherence, photon correlation spectroscopy, and the dynamic structure factor as well as information on the mechanics of XPCS experiments. As a result, we highlight the impact that this infrastructure has had on materials research and the bright future that is forthcoming with the anticipated upgrade of many third-generation synchrotron sources to fourth-generation multibend achromat sources.

36 MATERIALS SCIENCE↗